暖通主要设备材料表新风机组序号设备型式冷量(kw)热量(kw)送/排风量(m3/h)机外静余压(Pa)电机容量(kw)电压(V)盘管空气进口温度()冷水进/出水温()热水进/出水温()噪声dB(A)重量(kg)数量(台)加湿量(kg/h)供冷工况供热工况干球湿球PAU-1B-01叉流板式热回收新风机组91838000/65004704/2.23802925.9-116/1155/45678201PAU-1B-02叉流板式热回收新风机组31283600/36005301.5/1.53802926.9-116/1155/45645601PAU-1B-03新风机组(变频风机)202256160004722.2238033.426.9-116/1155/456713801PAU-1B-04新风机组(双风机分控)1011288000(16000)4702.2238033.426.9-116/1155/456713801PAU-1B-05新风机组(双风机分控)76966000(12000)4501.5238033.426.9-116/1155/456710001PAU-1B-06新风机组(双风机分控)63805000(10000)3201.1238033.426.9-116/1155/45629001PAU-1F-01风冷型双温新风机组5454.43400/30004307.138033.426.9-116/1155/4563560120AHU-1F-02干式空调机组7.61.230002651.138026201815/2055/45634804PAU-1F-03风冷型双温新风机组36322000/20003204.938033.426.9-116/1155/4556.5440112PAU-1F-04风冷型双温新风机组1441498000/720052017.538033.426.9-116/1155/4567820148AHU-1F-05空调机组887422000558423802618.7186/1155/457118401AHU-1F-06风冷型双温空调机组664810000/300044621.638026.520.413.66/1155/4563900112PAU-1F-07风冷型双温新风机组36322000/20002094.938033.426.9-116/1155/4555440112PAU-1F-08风冷型双温新风机组54483000/30003807.138033.426.9-116/1155/4563480118AHU-1F-09风冷型双温空调机组53456800/270045517.538028.422.313.66/1155/4564800116PAU-1F-10风冷型双温新风机组90805000/500043011.238033.426.9-116/1155/4565580130AHU-1F-11空调机组652816000472323802618.7186/1155/457313801PAU-1F-12风冷型双温新风机850053021.638033.426.9-116/1155/4568900160PAU-1F-13风冷型双温新风机组54563500/33004508.638033.426.9-116/1155/4564560121PAU-1F-14风冷型双温新风机组951127000/700052017.538033.426.9-116/1155/4567800148AHU-1F-15风冷型双温空调机组24.6163200/9003207.138027.320.7186/1155/455856015.4PAU-1F-16风冷型双温新风机组72644000/34005208.638033.426.9-116/1155/4564560124PAU-2F-01风冷型双温新风机组72644000/44005308.638033.426.9-116/1155/4564560124PAU-2F-02风冷型双温新风机组50452800/28005007.138033.426.9-116/1155/4563440117PAU-2F-03风冷型双温新风机组54483000/30005007.138033.426.9-116/1155/4563440118PAU-2F-04风冷型双温新风机组36322000/20005004.938033.426.9-116/1155/4556.5400112PAU-2F-05风冷型双温新风机组21619212000/1200055027.838033.426.9-116/1155/4569860172PAU-2F-06可变风量新风机组7910062005002.238033.426.9-116/1155/45675801PAU-2F-07风冷型双温新风机组43392400/24005007.138033.426.9-116/1155/4563440114AHU-2F-08干式空调机组7.61.230005001.138026201815/2055/45634401PAU-2F-09风冷型双温新风机组1401207500/870067517.538033.426.9-116/1155/4572.5740145PAU-2F-10风冷型双温新风机组83744600/460050011.238033.426.9-116/1155/4565520227AHU-2F-11空调机组652816000635323802618.7186/1155/457312801PAU-2F-12风冷型双温新风机组1501358400/840054521.638033.426.9-116/1155/4568.5780148PAU-2F-13风冷型双温新风机组1501359000/900054521.638033.426.9-116/1155/4568.5780148PAU-3F-01风冷型双温新风机组54402500/25005007.138033.426.9-116/1155/4563480115PAU-3F-02风冷型双温新风机组72644000/40005308.638033.426.9-116/1155/4564560124PAU-3F-03风冷型双温新风机组108966000/600050013.538033.426.9-116/1155/4567700136PAU-3F-04风冷型双温新风机组1621449000/900054521.638033.426.9-116/1155/4568.5860154PAU-3F-05风冷型双温新风机1000050021.638033.426.9-116/1155/4568900160PAU-3F-06风冷型双温新风机组90805000/500043011.238033.426.9-116/1155/4565580130PAU-4F-01风冷型双温新风机组49.7644000/30005308.638033.426.9-116/1155/4564560124PAU-4F-02风冷型双温新风机组24.9322000/16005004.938033.426.9-116/1155/4556.5440112AHU-4F-02叉流板式热回收新风机120005004/2.238033.426.9-116/1155/45691360190AHU-4F-03叉流板式热回收新风机组113.41449000/72005451.5/1.538033.426.9-116/1155/4568.5860154AHU-4F-01风冷型双温新风机组31540025000/2000055020.038033.426.9-116/1155/457517001150PAU-4F-04风冷型双温新风机组63805000/400050011.238033.426.9-116/1155/4565520130PAU-4F-05风冷型双温新风机组75.6966000/480050013.538033.426.9-116/1155/4567580136PAU-4F-06风冷型双温新风机组37.8483000/24005007.138033.426.9-116/1155/4563440118PAU-4F-07风冷型双温新风机组25.2322000/16005004.938033.426.9-116/1155/4556.5400112AHU-5F-01风冷型双温可变风量空调机组(变频)70577000/30006758.138027.822.110.26/1155/4572.5800112AHU-14F-01风冷型双温空调机组38386000/20005008.138027.822.110.26/1155/4567700112PAU-XF-01新风机组(立式)62938033.426.9-116/1155/45654401234.8PAU-XF-02新风机组(立式)49.764400053013.538033.426.9-116/1155/45643501227.8PAU-XF-03新风机组(吊顶式)37.34830005007.138033.426.9-116/1155/45632002420.9暖通主要设备材料表风机盘管设备型式设备型式(m3/h)电机容量(W)制冷量噪声dB(A)中速冷量(W)冷水进/出水温()空气进口温度()水流量(L/S)水流阻力(kpa)出口静压(pa)热量(W)热水进/出水温()进口干球温度()干球湿球卧式暗装20028011(15)76915/202618.70.040112(30)135055/452036卧式暗装30041517(20)119015/202618.70.060212(30)203055/452038.5卧式暗装40056023(26)160315/202618.70.080312(30)271055/452040卧式暗装50067529(35)204515/202618.70.100512(30)225355/452043卧式暗装60076539(44)245415/202618.70.120712(30)405555/452045卧式暗装800109052(62)345615/202618.70.2001012(30)543055/452046卧式暗装1000135557(69)430015/202618.70.240612(30)676055/452048卧式暗装1200165086(90)506615/202618.70.3001012(30)811055/452049注:()内为高静压风机盘管。根据设计要求,施工图中的接风道的风机盘管为高静压风机盘管。设备型式风道尺寸HD(mmmm)送风口尺寸HD(mmmm)门铰式回风口尺寸HD(mmmm)回风口安装光触媒空气净化器数量(台)侧送风口散流器送风口尺寸(mmmmmm)电量(W)电压(V)风阻(pa)不含新风含新风一个散流器两个散流器卧式暗装200500150 (500150)500150 (500150)800150 (800150)200200 (200200)150150 (150150)800300 (800300)800300100 (800300100)8(8)220(220)6(6)36(169)卧式暗装300600150 (600150)600150 (600150)900150 (900150)250250 (250250)200200 (200200)900300 (900300)900300100 (900300100)8(8)220(220)6(6)86(157)卧式暗装400700150 (700150)700150 (700150)1000150 (1000150)300300 (300300)200200 (200200)1000300 (1000300)1000300100 (1000300100)8(8)220(220)6(6)55(47)卧式暗装500800150 (800150)800150 (800150)1100150 (1100150)300300 (300300)200200 (200200)1100300 (1100300)1100300100 (1100300100)8(8)220(220)6(6)116(15)卧式暗装600900150 (900150)900150 (900150)1200150 (1200150)350350 (350350)250250 (250250)1200300 (1200300)1200300100 (1200300100)8(8)220(220)6(6)136(76)卧式暗装8001200150 (1200150)1200150 (1200150)1500150 (1500150)400400 (400400)300300 (300300)1500300 (1500300)1500300100 (1500300100)8(8)220(220)6(6)354(149)卧式暗装10001500150 (1500150)1500150 (1500150)1800150 (1800150)450450 (450450)300300 (300300)1800300 (1800300)1800300100 (1800300100)8(8)220(220)6(6)65(74)卧式暗装12001700150(1700150)1700150 (1700150)2000150(2000150)500500(500500)350350(350350)2000300(2000300)2000300100(2000300100)8(8)220(220)6(6)6(20)总体要求:1,空调机组、新风机组、风机盘管选用低噪声设备。2,采用热回收型新风机组或空调机组,其额定热回收效率60% 。3,所有空调系统均可实现可调新风比及过渡季全新风运行。4,空调冷水系统设计工况ER=0.01970.0241 (降低36%)。5,风冷型双温新风机组自带控制箱。要求具备DDC楼控接口,具备机组设备的短路、过载、断相等保护功能。6,控制箱至设备管线由设备供应商自理。7,无热回收装置的新风机组,新风进口设电动阀,其余新风机组、组合式空调机组所需电动阀,均机组自带。8,新风机组、组合式空调机组所需强、弱电控制柜均机组自带。9,吊顶内风机盘管电源均预留在吊顶内,其至空调调速开关的管线均由设备供应商自理,预埋JDG25/KG25(由总包完成预埋),调速开关底边距地1.3M暗装。10,另可参见暖通设计设计说明及施工说明。空调处理机组:1,现场DDC控制,DDC控制器的通信协议应符合楼宇控制系统要求。2,根据回风温度,实现空调送风机与排风机的变频调速运行。设回风机时,根据机组新、回风混合点静压实现空调回风机的变频调速运行。3,盘管回水管设具备冷、热模式转换的动态平衡电动调节阀。根据回风温度,调节冷、热水流量。4,以上控制风机优先,即:动态平衡电动调节阀处于常开状态,仅当风机转速达到下限值时,进行调节。5,根据回风相对湿度,控制加湿器的工作状态。6,根据回风与新风焓值比较,控制热回收装置的工作状态。7,根据室内设计状态焓值与新风焓值的比较,确定是否全新风运行,即:夏季,新风焓值低于室内设计状态焓值时,全新风运行。新风焓值室内设计状态焓值时,最小新风量运行。冬季,新风焓值高于室内设计状态焓值时,全新风运行。新风焓值室内设计状态焓值时,最小新风量运行。8,所有空气过滤器及风机设压差报警。9,新风进风阀与送风机连锁。新风处理机组:1, 盘管回水管设具备冷、热模式转换的动态平衡电动调节阀。根据送风温度,调节冷、热水流量。2, 根据送风相对湿度,控制加湿器的工作状态。3, 根据排风与新风的焓值比较,控制热回收装置的工作状态。4, 表冷器设防冻开关,实现盘管的防冻控制,即:达到防冻控制温度时,使动态平衡电动调节阀全开同时关闭风机与新风进风阀。5, 所有空气过滤器及风机设压差报警。6, 新风进风阀与风机连锁。热回收交换器:1, 夏季热回收交换器的新风及排风入口分别设置焓值传感器,比较新风及排风焓值,新风焓值高于排风焓值时工作。否则,打开旁通。2, 冬季利用新风入口设置的焓值传感器输出的温度信号,比较新风温度及冬季室内设计温度,前者低于后者时工作,否则,打开旁通。风机盘管:1, 风机盘管配有独立温控器,温控器应具有冷、热模式转换功能。2, 风机盘管回水管设具有断电复位功能的动态平衡电动两通阀,风量由手动三速开关控制。冷却塔(一)总体要求1、满足循环冷却水的最大散热要求,热力性能要求达到100%以上。并有权威的检验证书。2、飘水损失:不大于总循环水量的0.001,并有权威机构检验证书;要求制造商具有ISO9000系列认证。3、风载荷:1.2KN,能承受十二级风时的载荷4、地震载荷:地震烈度按度设计构造。4、可接受的产品为进口或国内合资品牌产品,但技术标准必须满足本技术规范的要求。5、设备选型应满足现场实际安装条件。(二)产品制造需符合以下标准和规范:冷却水塔及其相辅助设备之材料、制造、组焊、检验、测试与涂装必须遵守下列有关法规或标准之最新版次的规定:GBJ102-87工业循环冷却设计规范GB7190-87玻璃纤维增强塑料冷却塔GB1033-86塑料比重试验方法GB2046-80塑料燃烧性能试验方法GB/T1040-92塑料拉伸性能试验方法NDGJ88-89冷却塔淋水填料技术规定NDGJ89-89工业冷却塔测试技术规定如有国外规范和法规与中国国标有抵触,应遵循国家标准(三)产品要求1、塔体塔体结构支架:要求采用金属框架结构,强度、刚性好,能平稳承受冷却塔运行时的各种荷载。所有金属构件必须经过去除氧化层及油脂,并磷化防腐处理,外层再经过热浸锌处理。塔身外壳处理:塔身外壳为Z600以上镀锌钢或玻璃钢材质,(金属材料应考虑防雷措施)表面商标字迹清晰端正,有产品铭牌。塔芯填料:要求耐70高温、-50低温,不变形,抗紫外线、耐酸蚀,耐卤蚀,阻燃性好,氧指数要求不小于33,达到国家B1级标准,寿命不小于15年。填料整体板型结构合理,风阻系数小,气流水流分布均匀,水损失低。重量轻,亲水性能好。填料不应采用再生材料制作。且该填料要求必须采用先进的安装方式以便于日后的清洗维护。集水槽:要求采用深水型集水槽,避免冷却水泵开启时,产生汽蚀。并有自动、手动补水装置,以及溢水口和排污口。集水槽上部要求采用防飞溅措施,且附带隔声设施。冷却塔为自带集水盘型。冷却塔出水口:要求采用出水滤网,出水滤网材质要求采用304不锈钢。每一冷却塔应由供货商提供完整的产品,包括塔体结构、底盘、集水缸、框架、围护、电动机、传动装置及风机、风扇网、配水系统、填料、安装维修扶梯、塔体维修通道、检修门等,应能满足机组常年使用的要求。2、电机:概述:要求采用冷却塔专用电机厂生产的全封闭式电机,具有防水性能;采用皮带传动,皮带选用进口防水三角带。电动机额定负荷应合适于相应设备起动及满负荷的需要,电动机在已知工况环境及现场条件下能连续额定运行,使用寿命15年以上。基本结构:塔内全封闭三相异步电动机。防护等级IP55。绝缘耐温等级F级品牌选用ABB或GE,SIEMENS。技术要求:电动机应能满足风机需要电动机输出的转速、转矩、及其他机械要求。当电源的电压与额定值的偏差不超过+10-10%以及电源的频率与额定值的偏差不超过2HZ时,输出功率仍能维持额定值。在出线端标志字母顺序与三相电源的电压相序方向相同时,从轴伸出端视之,电动机应为顺时针方向旋转。电动机应具有可靠的接地装置,并应有指示接地的明显标志。皮带减速器采用皮带减速器,减速器内应配置进口轴承,轴承使用寿命至少10万小时。减速机、传动轴及马达支撑架必须以型钢为主体的一体钢构,传动轴及连轴器应设防护盖装置。优质皮带采用进口名牌产品。风机风机应采用高强度铝合金机翼型叶片风机,风机翼尖与塔体内壁之间的间隙均匀,保证叶片与风筒不相碰。风机应为超低噪声型冷却塔专用风机,风机须经动平衡和静平衡测试。风扇叶下加装消声导风罩,防止空气逆流。风机及电机及传动机构被风胴整个包裹,任何部分不能暴露在风胴之外。支撑及连接部件结构支架要求采用金属框架结构,所有金属结构件厚度必需经过除氧化层及油脂,并磷化防腐处理,外层再经过热浸镀锌处理。连接部件必须为优质不锈钢连接部件。底盆及集水缸:底盆及集水缸如为玻璃钢,必须为达到国家B1难燃级标准材质,提供检测报告。集水量必须保证系统正常运行。补水、溢水、排污装置:冷却塔应设自动和手动补水装置,并带有溢流及排污口;自动补水器采用不腐蚀浮球的遥控浮球阀,动作应严密灵活。配水系统:采用先进、合理的布水方式,要求布水均匀、抗堵塞、清理维修方便。该设备能够及时提供所需的备品备件、易损件。冷却塔应由供货商提供可靠、方便的塔内贯通式维修通道,以便进行塔体内部的维修、清理及填料更换,如塔顶无可靠的上人检修平台,应在塔顶部加设钢制检修平台,以便于电机、风机、轴承等的维护及检修工作。序号设备名称型号及规格单位数量1冷却塔(方形横流,低噪音型冷却塔)1、冷却水水量为420m3/h2、室外湿球温度:26.93、进水温度:374、出水温度:325、电机功率:5.5KWX3台4冷却塔设备技术参数表注:1、单台冷机运行流量为357m3/h,冷却塔设计水量已放大。2、冷却塔基础土建专业只在屋顶预留反梁,冷却塔需自配型钢基础。暖通主要设备材料表制冷站设备表设备名称规格与性能数量单位承压备注离心式冷水机组Q=1758kw(6/11)额定工况COP5.0,N321kw2台1.
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 公司每年每月团建活动方案
- 公司直播运营策划方案
- 公司节电活动方案
- 2025年药学专业技术资格考试题及答案
- 2025年医学专业考生必做试题及答案
- 2025年文化产业管理专业考试试卷及答案
- 2025年文化遗产保护技师职业资格考试试题及答案
- 2025年数字营销与品牌策略课程考试试卷及答案
- 2025年思想政治教育专业考试试题及答案
- 2025年生态文明建设与管理考试卷及答案
- 炊事员培训试题及答案
- 模板包清工合同协议
- 2025年安全月主题宣贯课件
- 数字经济与低空产业发展:赋能机制与治理策略
- DB11 T 640-2009 旅游咨询服务中心设置与服务规范
- 浙江省宁波市慈溪市部分校2025届数学五年级第二学期期末考试模拟试题含答案
- 命案防控讲座课件
- 《测绘基础知识》考试复习题库(含答案)
- 水厂反恐应急培训课件
- 2025年行政处罚法知识考试题库及答案(共90题)
- 石油天然气工业 完井用地层隔离阀及其相关工具 征求意见稿
评论
0/150
提交评论