有机复合外套金属氧化物避雷器及主要技术参数有机复合外套金属氧化物避雷器是将金属氧化物避雷器和有机复合绝缘材料的优异特性集于一体,可以延缓冲击力,具有良好的防爆性能。用于保护6kV、10kV、110kV电力系统电站及配电设备免受过电压危害的一种保护设备。其主要技术参数列表如下:表一 配电型HY5WS系列产 品型 号避雷器额定电压系统额定电压持续运行电压直流参考电压U1mA不小于8/20us标称电流下残压方波通流容量2ms 18次4/10us冲击电流容量2次0.75U1mA下泄漏电 流不大于爬电比距高度HkV(有效值)kVkV(峰值)AkAuAmm/kVmmHY5WS-7.6/307.6641530100405026192HY5WS-10/3010681530100405026192HY5WS-12.7/5012.7106.62550100405027257HY5WS-16.7/5016.71013.62550100405027257HY5WS-17/50171013.62550100405027257HY5WS-17/50171013.62550100405031272HY5WS-17/50Q171013.62550100405027303表二 电站型HY5WZ系列产 品型 号避雷器额定电压系统额定电压持续运行电压直流参考电压U1mA不小于8/20us标称电流下残压方波通流容量2ms 18次4/10us冲击电流容量2次0.75U1mA下泄漏电 流不大于爬电比距高度HkV(有效值)kVkV(峰值)AkAuAmm/kVmmHY5WZ-7.6/277.66414.527200405027192HY5WZ-10/27106814.527200405027192HY5WZ-12.7/4512.7106.62445200405027257HY5WZ-13.5/3113.51010.518.731200405027257HY5WZ-17/45171013.62445200405027257HY5WZ2-17/45W171013.62445400405027257HY5WZ-17/45Q171013.62445200405027303HY5WZ-34/85342027.24885150405027404HY5WZ-42/134423523.473134200,400655025520530570580HY5WZ-51/134513540.873134200,400655025HY5WZ-54/134543540.873134200,400655025HY5WZ-52.7/13452.73540.873134200,400655025HY10W-100/26010011078145260600,80010050241280HY10W-102/26610211079.6148266600,80010050251280HY10W-108/28110811084157281600,80010050241280表三 线路用HY5W、HY5WX系列产 品型 号避雷器额定电压系统额定电压持续运行电压直流参考电压U1mA不小于8/20us标称电流下残压方波通流容量2ms 18次4/10us冲击电流容量2次0.75U1mA下泄漏电 流不大于爬电比距高度HkV(有效值)kVkV(峰值)AkAuAmm/kVmmHY5WX-51/134513540.873134400655025520530570600HY5WX-54/142543543.277142400655025HY5WX-54/150543543.280150400655025HY5CX-42/12042356570120400655025HY10WX-100/26010011078145260600,80010050241280HY10WX-102/26610211079.6148266600,80010050251280HY10WX-108/28110811084157281600,80010050241297表四 电容器型HY5WR系列技术参数产 品型 号避雷器额定电压系统额定电压持续运行电压直流参考电压U1mA不小于8/20us标称电流下残压方波通流容量2ms 18次4/10us冲击电流容量2次0.75U1mA下泄漏电 流不大于爬电比距高度HkV(有效值)kVkV(峰值)AkAuAmm/kVmmHY5WR-5/13.553.347.213.5400655027192HY5WR-7.6/277.66414.427400655027192HY5WR-10/27106814.427400655027192HY5WR-12.7/4512.7106.62445400655027257HY5WR-17/45171013.62445400655027257HY5WR-34/12034351951120400655025520530570580HY5WR-42/134423523.473134400655025HY5WR-51/134513540.873134400655025HY5WR-54/134543540.873134400655025HY5WR-52.7/13452.73540.873134400655025HY5WR-84/221846667.2121221400,6006550251078HY5WR-90/236906672.5130236400,6006550251078表五 旋转电机型HY5W 、HY2.5W 、HY1.5W系列技术参数类别产 品型 号避雷器额定电压电机额定电压持续运行电压直流参考电压U1mA不小于8/20us标称电流下残压方波通流容量2ms 18次4/10us冲击电流容量2次0.75U1mA下泄漏电 流不大于爬电比距高度HkV(有效值)kVkV(峰值)AkAuAmm/kVmm发电机HY5W-4/9.543.153.25.79.5400405030184HY5W-8/18.786.36.311.218.7400405027184HY5W-13.5/3113.510.510.518.631400405027184HY5W-16.7/3816.713.813.824.438400405027257HY5W-17.5/4017.513.813.824.440400405027257HY5W-20/422015.7515.028.042400405027257HY5W-23/512318.018.031.951400405027257HY5W-25/56.22520.020.035.456.2400405027257电动机HY2.5W-4/9.543.23.25.79.5200405030184HY2.5W-8/18.786.36.311.218.7200405030184HY2.5W-13.5/3113.510.510.518.631200405030184电机中性点HY1.5W-2.4/62.43.21.93.46200405032184HY1.5W-4.8/124.86.33.86.812200405028184HY1.5W-8/19810.56.411.419200405027184HY1.5W-10.5/2310.513.88.414.923200405027184HY1.5W-12/261215.759.617.026200405027184HY1.5W-13.7/29.213.718.011.019.529.2200405027257HY1.5W-15.2/31.715.220.012.221.631.7200405027257表六 变压器中性点型HY1.5W系列产 品型 号避雷器额定电压系统额定电压持续运行电压直流参考电压U1mA不小于8/20us标称电流下残压方波通流容量2ms 18次4/10us冲击电流容量2次0.75U1mA下泄漏电 流不大于爬电比距高度HkV(有效值)kVkV(峰值)AkAuAmm/kVmmHY1.5W-60/144631104885144400655025830HY1.5W-72/1867211058103186400655025830HY1.5W-144/320144220116205320400,6006550251620瓷外套金属氧化物避雷器及主要技术参数瓷外套式金属氧化物避雷器可用于限制变压器、电容器、真空开关、变压器中性点等的过电压。该产品内部采用了优质半导体材料,高强度棒以及金属压板把电阻片固定在同心圆内,使避雷器整体结构更加牢固,保证了在安装和运输过程中产品内部原件仍然保持良好的接触,减少局部放电量,并且半导体材料形成的保护层使得电阻片避免吸潮,延长了其侧面的有效爬距,从而提高了产品的可靠性,延长了使用寿命。避雷器主要技术参数列表如下: 表一 配电型Y5W 、 Y5WS系列产 品型 号避雷器额定电压系统额定电压持续运行电压直流参考电压U1mA不小于8/20us标称电流下残压方波通流容量2ms 18次4/10us冲击电流容量2次0.75U1mA下泄漏电 流不大于爬电比距高度HkV(有效值)kVkV(峰值)AkAuAmm/kVmmY5WS-7.6/307.6641530100405034250Y5WS-10/3010681530100405034250Y5WS-12.7/5012.7106.62550100405027290Y5W-12.7/5012.7106.62550100405027290Y5WS-16.5/5016.51013.62550100405027290Y5WS-17/50171013.62550100405027290Y5W-17/50171013.62550100405027290表二 电站型Y5WZ 、Y10W系列产 品型 号避雷器额定电压系统额定电压持续运行电压直流参考电压U1mA不小于8/20us标称电流下残压方波通流容量2ms 18次4/10us冲击电流容量2次0.75U1mA下泄漏电 流不大于爬电比距高度HkV(有效值)kVkV(峰值)AkAuAmm/kVmmY5WZ-7.6/277.66414.527200405034250Y5WZ-10/27106814.527200405034250Y5WZ-12.7/4512.7106.62445200405028290Y5WZ-16.5/4516.51013.62445200405028290Y5WZ-17/45171013.62445200405028290Y5WZ-42/134423523.473134200,4006550259701080Y5WZ-51/134513540.873134200,400655025Y5WZ-52.7/13452.73540.873134200,400655025Y10WZ-100/26010011078145260600,80010050251375Y10WZ-102/26610211079.6148266600,80010050251375Y10WZ-108/28110811084157281600,80010050251375表三 电容器型Y5WR系列产 品型 号避雷器额定电压系统额定电压持续运行电压直流参考电压U1mA不小于8/20us标称电流下残压方波通流容量2ms 18次4/10us冲击电流容量2次0.75U1mA下泄漏电 流不大于爬电比距高度HkV(有效值)kVkV(峰值)AkAuAmm/kVmmY5WR-7.6/277.66413.827400655034250Y5WR-12.7/4512.7106.62345400655028290Y5WR-17/45171013.62445400655028290Y5WR-42/134423523.4701344006550259701080Y5WR-51/134513540.873134400655025Y5WR-52.7/13452.73540.873134400655025Y5WR-84/221846667.2121221400,6006550251200Y5WR-90/236906672.5130236400,6006550251200表四 电机型Y5W 、Y2.5W 、Y1.5W系列类别产 品型 号避雷器额定电压电机额定电压持续运行电压直流参考电压U1mA不小于8/20us标称电流下残压方波通流容量2ms 18次4/10us冲击电流容量2次0.75U1mA下泄漏电 流不大于爬电比距高度HkV(有效值)kVkV(峰值)AkAuAmm/kVmm发电机Y5W-4/9.543.153.25.79.5400405028270Y5W-8/1986.36.311.219400405028270Y5W-13.5/3113.510.510.518.731400405028315Y5W-17.5/4017.513.813.824.440400405028315Y5W-20/402015.7515.028.040400405028315Y5W-23/512318.018.031.951400405028315Y5W-25/56.22520.020.035.456.2400405028315电动机Y2.5W-4/9.543.153.25.69.5200405037270Y2.5W-8/1986.36.311.319200405034270Y2.5W-13.5/3113.510.510.518.931200405028315电机中性点Y1.5W-2.4/62.43.151.93.46200405040270Y1.5W-4.8/124.86.33.86.912200405037270Y1.5W-8/19810.56.411.319200405034270Y1.5W-10.5/2310.513.88.414.923200405028270Y1.5W-12/261215.759.617.026200405028315Y1.5W-13.7/29.213.718.011.019.529.2200405028315Y1.5W-15.2/31.715.220.012.221.631.7200405028315表五 变压器中性点型Y1.5W系列产 品型 号避雷器额定电压系统额定电压持续运行电压直流参考电压U1mA不小于8/20us标称电流下残压方波通流容量2ms 18次4/10us冲击电流容量2次0.75U1mA下泄漏电 流不大于爬电比距高度HkV(有效值)kVkV(峰值)AkAuAmm/kVmmY1.5W-60/1446011048851444006550258851200Y1.5W-72/1867211058103186400655025Y1.5W-96/26096220771372604006550251200Y1.5W-144/320144220116205320400,6006550251810Y1.5W-207/440207330166292440400,6006550252770327.5KV带间隙金属氧化物避雷器及主要技术参数表一 带串联间隙Y5C系列产 品型 号避雷器额定电压系统额定电压持续运行电压工频放电电压不小于8/20us 5kA冲击残压方波通流容量2ms 18次高 度HkV(有效值)AmmY5C-3.8/13.53.832913.575 , 150250Y5C-7.6/277.664162775 , 150250Y5C-12.7/4512.7106.6264575 , 150290Y5C-22/582218124258400290表二 带并联间隙Y0.5B系列产 品型 号避雷器额定电压系统额定电压持续运行电压直流参考电压U1mA不小于8/20us 冲击残压1.2/50 us冲击放电电压不大于方波通流容量2ms 18次高 度HkV(有效值)kVkVkVAmmY0.5B-7.6/157.66411.51515200 , 400250Y0.5B-12.7/2812.7106.7212828200 , 400315,290Y0.5B-42/794227.531.5607979200 , 400315,290静止补偿装置用成套金属氧化物避雷器及主要技术参数产 品型 号避雷器额定电压系统额定电压持续运行电压直流参考电压U1mA不小于工频参考电压U1mA不小于标称放电电流下残压不大于方波通流容量2ms 18次高 度HkV(有效值)kVkVkVAmmY0.5 W-45/106453541.2676.4451066001200Y0.5WR-45/110453538.876.34511012001200Y0.5WR-42/98.7423534.869.64298.76001080Y0.5WR-42/924235236042926001080Y0.5WR-36/81.6363528.3656.643681.66001080Y0.5 W-24/56.2243537.82456.26001080315kV系统用磁吹阀式避雷器及主要技术参数型 号FCD3 - 3FCD3 - 4FCD3 - 6FCD3 - 10FCD3 - 13FCD3 - 15电机标称电压kV(有效值)3.1546.310.513.815.75避雷器额定电压kV(有效值)3.84.67.612.716.719工频放电电压kV(有效值)7.5 9.59 11.415 1825 3033 3937 441.2/50 us冲击放电电压不大于kV(峰值)9.51219314045残压(8/20us)不大于kV(峰值)3kA9.512193140455kA1012.820334349电 导电 流直流试验电压kV3461013.215电流不大于uA101010101010重 量 ( kg ) 3.94.04.16.510.512.0伞 数112345高 度 (mm)250250320420640670安装铁夹高度(mm)206060110160160组合式金属氧化物避雷器(过电压保护器)及主要技术参数表一 复合外套无间隙金属氧化物避雷器产 品型 号避雷器额定电压系统额定电压持续运行电压接线方式直流参考电压U1mA不小于工频参考电压U1mA不小于标称放电电流下残压不大于方波通流容量2ms 18次备注kV(有效值)kVkVkVAHY5WS1-10/3021068相-相相-地16.015.010.610.03030100100配电型HY5WS1-17/502171013.6相-相相-地26.025.017.616.55050100100HY5WZ1-10/2721068相-相相-地15.014.410.09.52727150150电站型HY5WZ-17/452171013.6相-相相-地25.024.016.516.04545150150HY5WZ-51/16051/134513540.8相-相相-地84.073.059.049.0160134150150HY5WR1-10/2721068相-相相-地15.014.410.69.32727400400并联补偿电容器HY5WR1-17/452171013.6相-相相-地25.024.017.015.44545400400HY5WR1-51/15051/134513540.8相-相相-地84.073.059.047.0150134400400HY2.5WD1-8/23.38/18.7866.9相-相相-地14.011.27.07.623.318.7400400保护旋转电动机HY2.5WD1-13.5/38.713.5/3113.51011.5相-相相-地23.218.616.512.738.731.0200200表二 复合外套有串联间隙金属氧化物避雷器产 品型 号避雷器额定电压系统额定电压持续运行电压工频放电电压不小于1.2/50 us冲击放电电压100 A操作冲击电流残压500 A操作冲击电流残压标称放电电流下残压备注kV(有效值)峰值 kVHY5 CS1-10/27210681527202227配电型HY5 CS1-17/452171013.62550333645HY5 CZ1-10/242106815241819.524电站型HY5 CZ1-17/412171013.6254130.23341HY5 CZ1-51/1242513540.8851249198.6124HY2.5 CD1-8/18.72866.31518.713.714.818.7保护旋转电动机HY2.5 CD1-13.5/31213.51010.525312324.831HY2.5 CD1-7.6/1727.66.36.31517131417HY2.5 CD1-12.7/27212.710.510.5252720.52227表三 电机中性点过电压保护器 型 号保护器持续运行电压kV (有效值)电机额定电压kV (有效值)雷电冲击电流残压kV不大于直流1mA参考电压kV不小于图号TBPO2.13F2.133.1563.42TBPO4.6F4.66.3126.92TBPO7.6F7.610.51911.32 表四 TBP系列过电压保护器型 号保护 对象保护器持续运行电压(kV) r.m.s保护对象额定电压(kV) r.m.s工频放电电压 (不小于)(kV) r.m.s操作冲击电流残压(不大于) crest1.2/50冲击放电电压及残压 (不大于) (kV)crest 雷电冲击 电流残压 (不大于) (kV) crest 2ms方波冲击电流(A)相间距离产品高度(H)图号标准允许范围100A500A500A5kAmmTBP-A-3.8F/85电 动 机3.83.155.24.6813.2477.57.5400851823TBP-A-7.6F/857.66.310.49.3619141515TBP-A-7.6F/150150TBP-A-12.7F/8512.710.517.215.4827.6423.124.824.885197TBP-A-12.7F/150150TBP-A-12.7F/1351352074TBP-B-3.8F/85发 电 机 、 变 压 器 、 开 关 、 母 线 、 线 路3.8376.315.410.210.212400851823TBP-B-7.6F/857.661412.62120.420.424197TBP-B-7.6F/150150TBP-B-7.6F/76W1150762555TBP-B-7.6F/300W24003004367TBP-B-12.7F/8512.71023.220.8834.8433.833.840400852203TBP-B-12.7F/150150TBP-B-12.7F/1351352074TBP-B-12.7F/76W1150763256TBP-B-12.7F/300W24003004367TBP-B-42F/20042357264.893.41051051194002004756TBP-B-42F/3103105604TBP-B-42F/400W140011008TBP-B-42F/630W2-J63011509TBP-C-3.8F/85电 容 器3.837.46.6615.8810.411.7400851823TBP-C-7.6F/857.6614.613.141820.423.4197TBP-C-7.6F/150150TBP-C-7.
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年平面设计师技能认证考试模拟题集
- 2026届福建省建瓯市芝华中学化学高一上期中监测试题含解析
- 2025年保险公司招聘笔试备考资料及模拟题集答案
- 2025年高级工程师英语应用能力测试题库及答案解析
- 2025年物流工程师中级考试模拟题及备考建议
- 2025年财务经理面试必-备知识与预测题详解
- 2025年编程算法竞赛实战指南与模拟题解答
- 2025年监理《建设工程监理案例分析(交通)》考后答案
- 2025年财务会计主管招聘笔试指南及模拟题解析
- 2025年产品运营经理面试题及解析
- 设备材料进场报验单
- 班组长计划管理能力考试题库-上(选择题)
- 2024年景区托管运营合作协议
- 保定市城市建设投资集团有限公司招聘笔试真题2023
- (完整版)《机械制造工艺基础》教案
- 小学四年级数学口算题(每页60道直接打印).文档
- 材料设备进场验收单、样板确认、整改单
- 品牌服装设计课件
- 诱思探究理论
- 浅析中国保险业发展现状
- 铣床日常点检保养记录表
评论
0/150
提交评论