Corrosion Control and Monitoring.ppt_第1页
Corrosion Control and Monitoring.ppt_第2页
Corrosion Control and Monitoring.ppt_第3页
Corrosion Control and Monitoring.ppt_第4页
Corrosion Control and Monitoring.ppt_第5页
免费预览已结束,剩余26页可下载查看

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

CorrosionControlandMonitoring ABCCompanyABCChemicalComplexEngineeringSpecification CorrosionControl Monitoring SCOPEThisEngineeringSpecificationincludesexternalandinternalcorrosioncontrolandmonitoringforDOTregulatedpipelines Design construction constructioninspection constructionacceptance operation andmaintenanceofDOTregulatedpipelinesarecoveredbythisEngineeringSpecification CorrosionControl Monitoring GENERALAllDOTregulatedABCpipelinesrequireprotectionfromtheenvironment Corrosiveelementsinthepipelinestreammustbeneutralizedorthepipematerialmustberesistanttothestream CorrosionControl Monitoring Minimumrequirementsforcorrosioncontrol ExternalCorrosionControlBuriedDOTregulatedpipelineswillbecoatedandcathodicallyprotectedInternalCorrosionControlKnowncorrosionratebasedonhistoricaldataCorrosionratefromanationalstandarddatabaseDatacollectedfromlaboratoryprototypetesting CorrosionControl Monitoring Minimumrequirementsforcorrosioncontrol Continued AboveGroundExternalCorrosionControlCoatwithanapprovedsystemwithresistancetothesoilandinternalfluidtemperature CorrosionControl Monitoring REFERENCESNACERP0169 92SurfacePreparation NACENo 1 SSPC SP5 WhiteMetalBlastCleaningNACENo 2 SSPC SP10 NearWhiteMetalBlastNACENo 3 SSPC SP6 CommercialBlastNACENo 4 SSPC SP7 Brush OffBlast CorrosionControl Monitoring PERSONNELREQUIREMENTSEngineeringdesignwillbeperformedbyaCorrosionEngineerwithtrainingandexperienceintheproposedcorrosioncontrolsystem Coating lining andpaintinginspectionwillbeperformedbyaninspectorwithappropriatetrainingandexperience CorrosionControl Monitoring PERSONNELREQUIREMENTS Cont Cathodicprotectioninstallationswillbeinspectedbyaninspectorwithtrainingandexperienceincathodicprotectioninspection Internalcorrosionmonitoringinstallationswillbeinspectedbyaninspectorwithtrainingandexperienceininternalcorrosionmonitoringinspection CorrosionControl Monitoring DESIGNREQUIREMENTS EXTERNALCathodicProtectionCriteriaBuriedOnshorePipelines Pipe to soilpotentialequaltoormorenegativethan 0 85voltsreferencedtocopper coppersulfateelectrodeandrecordedimmediatelyaftercurrentinterruption Instant offpotential OffshorePipelines Pipe to waterpotentialequaltoormorenegativethan 0 80voltsreferencedtoasilver silverchlorideelectrodewith instantoff potentialreading CorrosionControl Monitoring TankBottoms Steel to soilpotentialequaltoormorenegativethan 0 85voltswithacopper coppersulfatehalfcelland instantoff potential Maximumpipelinepotential Equaltoorlessthan 1 5voltstoastandardcopper coppersulfatehalfcellwiththecurrenttemporarilyinterrupted CorrosionControl Monitoring CoatingRequirementsNewburiedpipesectionsshallbecoatedwithoneofthefollowingtypes FusionbondedepoxyCoaltarepoxyPolyolefintapePrefabricatedfilmsOthercoatingsystemsapprovedbyCentralEngineeringSurfacepreparationshallbeinaccordancewithmanufacturer srecommendationandAppendixB CorrosionControl Monitoring MethodsUsedforCathodicProtectionGalvanicAnodeSystemsProvideprotectiontothestructurebythepotentialdifferencegeneratedbytheelectrochemicalreactionbetweenthestructureandtheanodethroughasoilorwaterelectrolyte Typicallyusedinsoilorwaterwithresistivitylessthan5000ohm cm CorrosionControl Monitoring MethodsUsedForCathodicProtection Cont ImpressedCurrentSystemsUsesexternalsourceofDCpower usuallyanACtrans formerwithanACtoDCrectifier toprovidethedrivingvoltagetothestructuretobeprotected Potentialdifferencebetweentheanodeandthestructurecreatescurrentflowfromtheanodeintothesoilandontothepipeline Usedwhenthesoilresistivityexceeds5000ohm cmand ormorethan5amperesofimpressedcurrentarerequired CorrosionControl Monitoring EquipmentGalvanicAnodeSystemsAnode Magnesiumonshore GalvalumIIIoffshore Junctionboxtoconnectleadsfromstructureandanode ImpressedCurrentSystemsDCtransformer rectifier suppliedasaunit Anode s withinertorlowreactivitycharacteristics Terminalboxwithresistorstoadjustcurrentflowtoeachanodeoranodestring CorrosionControl Monitoring MiscellaneousInstalllightningarrestors Provideelectricalisolation Insulatingflangesorspools Minimizeinterferencewithbondingstations Installteststationstomeasurepotentials Completethefollowingdocumentation Bondingand oranodebeddatasheet Bondingstationdatasheet Teststationdatasheet CorrosionControl Monitoring ImpactonOperatingEquipmentApplyNEMAelectrical classsafetyrequirementstoallequipmentassociatedwithimpressedcurrentinstallations InstallCPequipmentinareasnotrequiringintrinsicallysafedesign Locateanodebedstominimizeeffectonotherstructuresandtominimizemechanicaldamagefromforeignconstruction CorrosionControl Monitoring PerforminterferencetestingonallequipmentthatmaybedamagedbythenewCPinstallation Testingshallinclude butisnotlimitedto thefollowingsituations Pipelinescrossingwithin5feet MetalStructureswithin5feetofthepipeline MetalStructureswithin200feetoftheanodebed CorrosionControl Monitoring ImpactonOperatingEquipmentDesignCPsystemswithcapacityforcurrentlossthroughinterferencebondsandfuturecurrentlossduetocoatingdeterioration Minimizecasinginstallationsforprotectionofthecarrierpipe PerforminterferencetestingasshowninCompanyCorrosionControl MonitoringSpecificationAppendixE Providebondingstationsforeachcasinginstallation CorrosionControl Monitoring DESIGNREQUIREMENTS INTERNALCorrosivechemicalsinthepipelinestreamMayreducestream liquidorgas qualityorCausegeneralthinningorpittingattackShallbehandledbyoneofthefollowingmethods Neutralizationorremovalofthecorrosivechemicals Selectapipematerialwhichisresistant Coattheinternalsurfacesofthepipe CorrosionControl Monitoring Designpackagewillcontain Provisionsforupset emergencyconditions Recommendedcorrosionmonitoringprogram Recommendedcorrosionmonitoringequipment Installationofpersonnelsafetydevicesandplatformsrequiredforsafeperformanceofduties Piggingprocedurewhenpiggingfacilitiesareincludedinthedesignpackage Compliancewithregulationsoflocal state andfederaljurisdictionforpiggingprocedures CorrosionControl Monitoring DocumentationRequirementsDeterminethicknessmeasurementlocations TML s basedonthemostprobablelocationsforcorrosionorerosion corrosiondamage SelectTML swiththeassistanceoftheCorrosionEngineer Collectbaselinethicknessreadingsonallnewinstallations Installcorrosionmonitoringequipmentwherethe worstcase corrosionattackisexpected Providecorrosionmonitoringdatasheets CorrosionControl Monitoring DESIGNREQUIREMENTS ABOVEGROUNDEXTERNALCoatwithacoatingsystemthatisrecom mendedfortheenvironment Preparesurfaceinaccordancewithexternal coating systemmanufacturer srecommendations SeeCompanyCorrosionControl MonitoringSpecificationAppendixB CorrosionControl Monitoring INSTALLATIONQualityControl ExternalSystemsCoatingsQualifiedInspectorpresence 100 Fieldappliedcoatingsystems 100 inspection Shopappliedcoatingsystems 100 inspection Coatingrepairs 100 inspection Protectallstoredcoatingmaterialsattheconstructionsitefromweather particularlydirectlysunlightandheat CorrosionControl Monitoring PadinthepipetrenchInspectjustpriortolayingthepipeinthetrench Removealltrashandconstructiondebris CablesInspectuponreceiptatjobsitetodetectnicksanddamage 100 inspectionatthemillwithpropermillcert Avoiddamagingcableinsulationduringinstallation Splicecablesabovegroundinterminalboxes Usenon conductiveconduitsforcableinstallation Makecathodecableconnectionsaboveground ifpossible Repairburiedconnectioninaccordancewiththeoriginalcoatingmanufacturer srecommendations CorrosionControl Monitoring Transformer RectifierSystemsInstallbyaqualifiedelectrician TestrectifieratmaximumdesignloadtoassuretheDCoutputmeetsthemanufacturer sspecificationsincludingthemaximumACripple Calculaterectifierefficiencyandrecordontherectifierdatasheet Verifythepositivecableisattachedtotheanodebedandthenegativecableisattachedtotheprotectedstructureorpipe CorrosionControl Monitoring MiscellaneousConsiderationsInspectcablesinterminalboxestoassurecorrectlabels Verifyteststations bondingstations andassociatedhardwareforcathodicprotectionservice Contactowners operatorsofforeignpipelinestoenabletestingbeforeandafternewcathodicprotectionprojectcommissioning Recordbasereadingsonthenewpipelineorstructurepriortocathodicprotectionsystemenergizing Recordpotentialsatallinterferencebondsandteststations Energizesysteminsmallcurrentincrementsandrecordpotentialswitheachincreaseuntilprotectionisachieved Checkbondingstationsforinterferenceproblems Fileallcommissioningdataintheoriginalequipmentfile CorrosionControl Monitoring QualityControlRequirements InternalSurfaceInspectcorrosionmonitoringinstallationswiththeservicesofaqualifiedCorrosionTechnician Takebaselinedatapriortopipelinecommissioning Installlinedpipelinesperdesign Repairliningoffieldjointsasrecommended Installcorrosionmonitoringdevicesperdesign Completeelectricalinstallationswithqualifiedelectricians Documentcommissioninginformationasapartoftheoriginalequipmentfile CorrosionControl Monitoring

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论