




已阅读5页,还剩29页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
美术馆中央空调系统设计摘要本设计为美术馆中央空调系统,拟为之设计合理的中央空调系统,为室内工作人员提供舒适的工作环境。设计内容包括:空调冷负荷的计算;空调系统的划分与系统方案的确定;冷源的选择;空调末端处理设备的选型;水系统的设计、布置与水力计算等内容。本设计依据有关规范考虑节能和舒适性要求,设计的空调系统采用风机盘管系统。关键词美术馆;中央空调;风机盘管系统;性能比较Abstract:The graduation project designs a central air conditioning system for Jingshang official building in Qingdao City, so as to create a comfortable work environment for the stuff. It contains: cooling load calculation; the estimation of system zoning; the selection of refrigeration units; the selection of air conditioning equipments; the design of calculation; the selection of relevant equipments; the design of water system and its resistance analysis; the insulation of chilled water pipes; noise and vibration control; etc. According to some correlation standard, allow for energy safe and indoor comfort, the air condition system of the design is Fan coil units (FCUs) system.Keywords: official building; Central air conditioning; Fan coil units (FCUs) system; The function compare目 录1.工程概况11.1设计任务书11.2设计规范及标准11.3基本气象参数11.4 建筑物相关资料12.设计方案的论证32.1美术馆(写字楼)空调特点32.1.1建筑特点32.1.2 使用特点32.2 方案比较32.3 方案的确定63.负荷计算73.1 通过外窗从室外传进室内的热量形成的冷负荷:73.2 通过外墙从室外传进室内的热量:73.3 通过屋顶从室外传进室内的热量:73.4 内墙、内门、地面楼板传热形成得冷负荷:73.5 过玻璃窗的日射得热引起的冷负荷73.6 人员散热引起的冷负荷83.7 照明散热引起的冷负荷83.8 设备散热冷负荷83.9新风冷负荷83.9负荷计算举例84.风机盘管选型125.水系统设计145.1水系统方案的确定145.2管路的布置和管径的确定145.3 凝结水管设计145.4 冷冻水管设计155.5 管段阻力计算175.6 热泵机组的选型215.7 水泵的选型215.8 膨胀水箱的选择216.电子除垢仪选型22结论23致谢24附录26III毕业论文1.工程概况本建筑是一幢四层高的美术馆,地处某市。美术馆地处我国胶东半岛地区,属北温带季风气候区,四季分明,夏热冬冷,春秋短暂,雨量较少,历年平均气温16,主导风向夏季为西南风,冬季为东北风。 美术馆主要用于展览、办公、业务办理以及休息,一共4层,屋顶布置机房,每层高3.6m,总建筑面积2580 m2,空调设计面积为1882 m2。美术馆空调负荷310092W,冷负荷指标164.7W/ m2。详细负荷组成见说明书。1.1设计任务书本设计拟为美术馆精上机械制造有限公司新建厂区美术馆提供舒适、合理的中央空调系统,使各领导以及其他办公人员能处于舒适的工作环境中。办公区设计目标:夏季温度27,冬季温度18,走廊与个房间温差为3,不计湿负荷,考虑到造价以及地理等因数,故不设新风系统。1.2设计规范及标准 1.采暖通风与空气调节设计规范(GBJ50019-2003)2.房屋建筑制图统一标准(GB/T500012001)3.采暖通风与空气调节制图标准(GBJ114-88)1.3基本气象参数表2.1 室外气象参数表地理位置(美术馆)海拔(m)大气压力(Kpa)室外平均风速m/s北纬东经8.9冬季夏季冬季夏季36.06120.331016.9997.26.54.9表2.2 室外计算(干球温度)表冬季夏季夏季空调室外计算湿球温度空气调节通风空气调节空调日平均通风-623527.23226表2.3 室内计算参数表名称房间用途温度()湿度(%)室内风速m/s夏季办公室2760v0.25冬季办公室2760v0.151.4 建筑物相关资料屋面:保温材料为沥青膨胀珍珠岩,厚度为70mm。外墙:外墙为厚度为240mm的红砖墙,墙外表面为水泥砂浆抹灰加浅色喷浆,墙为厚为70mm的加气混凝土保温层,内粉刷加油漆。外窗:双层钢窗,玻璃为5mm厚的吸热玻璃,无内遮阳措施。人数:人员数的确定是根据各房间的使用功能及使用单位提出的要求确定的,本美术馆人员密度按每人2.5平方米估算。照明、设备:由建筑电气专业提供,照明设备为暗装荧光灯,镇流器设置在顶棚内,荧光灯罩无通风孔,功率为18w/m。设备负荷为11w/m。空调使用时间:美术馆空调每天使用10小时,即8:0018:00。动力与能源资料:a. 动力:工业动力电 380V50Hz;b. 冷源:采用模块式风冷热泵机组。其他:新风量取30 m/h.p;2.设计方案的论证2.1美术馆空调特点2.1.1建筑特点美术馆的外围护结构多为钢筋混凝土的框架结构,采用自重的轻型墙体材料作为外围护结构。大量采用玻璃幕墙,采用大面积单层玻璃幕墙加铝合金饰板作为高层写字楼外围护结构的主流,其玻璃幕墙主要为6mm或8mm厚度的热反射镀膜玻璃。美术馆由吊顶或架空地板形成办公自动化机器和通讯设备的线性空间,美术馆的净高为2.6m左右。2.1.2 使用特点美术馆的使用性质与时间全楼大体一致,所以整幢楼可选择用同样的空调系统和设备,管理比较方便。美术馆一般采用集中或半集中空调系统。3)美术馆空调系统注意事项a.分区问题:按建筑物分为内区和外区,也可以按朝向分或根据房间用途、标准高低、负荷变化以及使用时间等特点划分系统。b.过度季节问题:过度季节外区可不用冷热源,但内区仍需要降温,这时应用室外空气直接进入内区降温,即节能又简单;或考虑采用一台小容量的制冷机。c.加班问题:个别美术馆或某层需要节假日加班,为此最好不要设太大的集中空调系统。d.特殊房间的个别控制问题:用风机盘管系统以便控制。2.2 方案比较表2.1 全空气系统与全水系统方案比较表比较项目全空气系统全水系统设备布置与机房1 空调与制冷设备可以集中布置在机房2 机房面积较大层高较高3 有时可以布置在屋顶或安设在车间柱间平台上1 机房面积小2 风机盘管可以设在空调机房内3 分散布置、敷设各种管线较麻烦风管系统1 空调送回风管系统复杂、布置困难2 支风管和风口较多时不易均衡调节风量1 放室内不接送、回风管使用寿命使用寿命长使用寿命较长温湿度控制可以严格地控制室内温度和室内相对湿度对室内温度要求严格时难于满足安装设备与风管的安装工作量大周期长安装投产较快,介于集中式空调系统与单元式空调器之间续表2.1 全空气系统与全水系统方案比较表比较项目全空气系统全水系统节能与经济性1 可以根据室外气象参数的变化和室内负荷变化实现全年多工况节能运行调节,充分利用室外新风减少与避免冷热抵消,减少冷冻机运行时间2 对热湿负荷变化不一致或室内参数不同的多房间不经济3 部分房间停止工作不需空调时整个空调系统仍需运行不经济1 灵活性大、节能效果好,可根据各室负荷情况自我调节2 盘管冬夏兼用,内避容易结垢,降低传热效率3 无法实现全年多工况节能运行维护运行空调与制冷设备集中安设在机房便于管理和维护布置分散维护管理不方便,水系统布置复杂、易漏水空气过滤与净化可以采用初效、中效和高效过滤器,满足室内空气清洁度的不同要求,采用喷水室时水与空气直接接触易受污染,须常换水过滤性能差,室内清洁度要求较高时难于满足消声与隔振可以有效地采取消防和隔振措施需尽量选择小型盘管以减小噪音,从而造价有所提升。风管互相串通空调房间之间有风管连通,使各房间互相污染,当发生火灾时会通过风管迅速蔓延各空调房间之间不会互相污染表2.2 风机盘管系统的特点表优点1)布置灵活,各风机盘管单独使用2)各空调房间互不干扰,可以独立地调节室温,并可随时根据需要开停机组,节省运行费用,灵活性大,节能效果好3)与集中式空调相比不需回、送风管道,节约建筑空间4)机组部件多为装配式、定型化、规格化程度高,便于用户选择和安装5)机房占地面积小6)使用季节长7)各房间之间不会互相污染缺点1)对机组制作要求高,则维修工作量很大2)机组剩余压头小室内气流分布受限制3)分散布置敷设各中管线较麻烦,维修管理不方便4)无法实现全年多工况节能运行调节5)水系统复杂,易漏水6)过滤性能差适用性适用于旅馆、公寓、医院、美术馆等高层多层的建筑物中,需要增设空调的小面积多房间建筑室温需要进行个别调节的场合表2.3 风机盘管的新风供给方式表供给方式特点适用范围房间缝隙自然渗入1)无规律渗透风,室温不均匀2)简单、方便3)卫生条件差4)初投资与运用费用低5)机组承担新风负荷,长时间在湿工况下工作1)人少,无正压要求,清洁度要求不高的空调房间2)要求节省投资与运行费用的房间3)新风系统布置有困难或旧有建筑改造机组背面墙洞引入新风1)新风口可调节,冬、夏季最小新风量;过渡季大新风量2)随新风负荷变化,室内直接受影响3)初投资与运行费节省4)须作好防尘、防噪声、防雨、防冻措施5)机组长时间在湿工况下工作同上房高为6m以下的建筑物单设新风系统,独立供给室内1)单设新风机组,可随室外气象变化进行调节,保证室内湿度与新风量要求 2)投资大3)占有空间多4)新风口尽量紧靠风机盘管,为佳要求卫生条件严格和舒适的房间,目前最常采用此方式单设新风系统供给风机盘管1)单设新风机组,可随室外气象变化进行调节,保证室内湿度与新风量要求2)投资大3)新风按至风机盘管,与回风混合后进入室内,加大了风机风量,增加噪声要求卫生条件严格的房间,目前较少采用此种方式本设计为美术馆的空调系统设计,系统的选定应注意档次和安全的要求,按负担室内空调负荷所用的介质来分类可选择四种系统全空气系统、空气水系统、全水系统、冷剂系统。全空气系统分一次回风式系统和二次回风式系统,该系统是全部由处理过的空气负担室内空调冷负荷和湿负荷;空气水系统分为再热系统和诱导器系统并用、全新风系统和风机盘管机组系统并用;全水系统即为风机盘管机组系统,全部由水负担室内空调负荷;冷剂系统分单元式空调器系统、窗式空调器系统、分体式空调器系统,它是由制冷系统蒸发器直接放于室内消除室内的余热和余湿。对于较大型公共建筑,建筑内部的空气品质级别要求较高,全水系统和冷剂系统只能消除室内的余热和余湿,不能起到改善室内空气品质的作用,但根据本设计中的办公场所地理位置,以及造价等多方面考虑,本建筑采用全水系统既经济,又不会使室内空气被过渡污染。终上所述,拟采用风机盘管系统,风机盘管的新风供给方式靠房间缝隙自然渗入。2.3 方案的确定本美术馆采用风机盘管系统。因为办公室是间歇性使用,白天使用,晚上关闭,人员分布较平均,同时各房间冷热负荷并不相同需要进行个别的调节,导致热湿比不同,所以全空气系统并不适合。 风机盘管空调方式,这种方式风管小,可以降低房间层高,但维修工作量大,如果水管漏水或冷水管保温不好而产生凝结水,对线槽内的电线或其它接近楼地面的电器设备是一个威胁,因此要求确保管道安装质量。风机盘管系统占空间少,使用也较灵活,但空调设备产生的振动和噪音问题需要采取切实措施予以解决。风机盘管机组的结构和工作原理,风机盘管机组是空调机组的末端机组之一,就是将通风机、换热器及过滤器等组成一体的空气调节设备。机组一般分为立式和卧式两种,可以按室内安装位置选定,同时根据室内装修要求可做成明装或暗装。风机盘管通常与冷水机组(夏)或热水机组(冬)组成一个供冷或供热系统。风机盘管是分散安装在每一个需要空调的房间内(如宾馆的客房、医院的病房、写字楼的各写字间等)。风机盘管机组中风机不断循环所在房间内的空气和新风,使空气通过供冷水或供热水的换热器被冷却或加热,以保持房间内温度。在风机吸风口外设有空气过滤器,用以过滤被吸入空气中的尘埃,一方面改善房间的卫生条件,另一方面也保护了换热器不被尘埃所堵塞。换热器在夏季可以除去房间的湿气,维持房间的一定相对湿度。换热器表面的凝结水滴入接水盘内,然后不断地被排入下水道中。3.负荷计算3.1 通过外窗从室外传进室内的热量形成的冷负荷:Q=KF(Tw. -tn) (1)式中:Q通过外窗的得热量所形成的冷负荷,WK外窗的传热系数,W/(m2oC)F外窗的面积,m2Tw外窗冷负荷逐时计算温度,oCtn室内设计温度,oCTw. =Tw.max-TwTw.max空调工程设计附录1查取从空调工程设计表2-8查取Tw从空调工程设计表2-7查取3.2 通过外墙从室外传进室内的热量:Q=KF(Tlf+Td)-Tn (2)式中:Q通过外墙的得热量所形成的冷负荷,WF外墙的面积,m2K外墙传热系数,本建筑取1.97W/(m2oC)Tlf冷负荷计算温度,从空调工程设计表2-11查取Td冷负荷计算温度修正值,从空调工程设计表2-13查取Tn室内温度,本设计去27 oC3.3 通过屋顶从室外传进室内的热量:Q=KF(Tlf+Td)-Tn (3)式中:Q通过屋顶的得热量所形成的冷负荷,WF屋顶的面积,m2K屋顶传热系数,本建筑取1.97W/(m2oC)Tlf冷负荷计算温度,从空调工程设计表2-11查取Td冷负荷计算温度修正值,从空调工程设计表2-13查取Tn室内温度,本设计去27 oC3.4 内墙、内门、地面楼板传热形成得冷负荷:Q=KFt1s (4)式中:K内结构传热系数,W/(m2oC)F内结构面积,m2 t1s计算温差,由新规范,对于走道,取3oC3.5 过玻璃窗的日射得热引起的冷负荷Q=KFCsCn (5)式中:Q通过玻璃窗进入室内的太阳辐射热WF窗户面积,m2K夏季通过单层3mm厚普通玻璃进入室内的太阳辐射热,从空调工程设计附录2查取W/(m2oC)Cs窗玻璃类型修正系数从空调工程设计表2-9查取 Cn窗内遮阳设施的遮阳系数,无遮阳措施取1,中间色百叶帘取0.6。3.6 人员散热引起的冷负荷Q=(Qx+Qq)n (6)式中:Qx单位人体显热散热引起的冷负荷,WQq单位人体潜热散热引起的冷负荷,Wn室内全部人 Q室内人员引起的冷负荷W 3.7 照明散热引起的冷负荷Q=F (7)式中:Q照明散热形成的冷负荷,W单位面积上产生的照明热W/m2F房间面积m23.8 设备散热冷负荷Q=F (8)式中:Q设备散热形成的冷负荷,W单位面积上设备产生的负荷W/m2F房间面积m23.9新风冷负荷 新风量的确定: Gw=(30n1.2)/3600Kg/s (9) 式中:Gw室内所需新风量Kg/s 30人均所需新风量30m3/h n室内人数,按人员密度计算 1.2设计常温下空气的密度=1.2Kg/m3 36001h=3600s 新风冷负荷: Qw=Gw(hw-hn) (10) 式中:Qw新风冷负荷W Gw新风量Kg/s hw室外空气焓值KJ/Kg hn室内空气焓值KJ/Kg 3.9负荷计算举例以房间101为例,各墙、各窗等外围护结构冷负荷详细计算如下表(其余各房间冷负荷汇总表见附录1。表3.1 101房间详细负荷计算表计算部位时刻89101112131415161718北内门K3.3463.3463.3463.3463.3463.3463.3463.3463.3463.3463.346F2.522.522.522.522.522.522.522.522.522.522.52T33333333333Q25.2925.2925.2925.2925.2925.2925.2925.2925.2925.2925.29北内墙K1.761.761.761.761.761.761.761.761.761.761.76F23.423.423.423.423.423.423.423.423.423.423.4T33333333333Q123.55123.55123.55123.55123.55123.55123.55123.55123.55123.55123.55南门太阳辐射热K73118185239258239185118734921F8.78.78.78.78.78.78.78.78.78.78.7Cs0.780.780.780.780.780.780.780.780.780.780.78Cn11111111111Q495.38800.751255.411621.851750.781621.851255.41800.75495.38332.51142.51北窗太阳辐射热K739210711511711510792737791F2.252.252.252.252.252.252.252.252.252.252.25Cs0.780.780.780.780.780.780.780.780.780.780.78Cn11111111111Q128.12161.46187.79201.83205.34201.83187.79161.46128.12135.14159.71西窗太阳辐射热K7392107115117226407536578523362F7.27.27.27.27.27.27.27.27.27.27.2Cs0.780.780.780.780.780.780.780.780.780.780.78Cn11111111111Q409.97516.67600.91645.84657.071269.212285.713010.173246.042937.162032.99东窗太阳辐射热K57853640722611711510792734921F3.63.63.63.63.63.63.63.63.63.63.6Cs0.780.780.780.780.780.780.780.780.780.780.78Cn11111111111Q1623.021505.011142.85634.61328.54322.92300.46258.34204.98137.5958.97北窗K2.92.92.92.92.92.92.92.92.92.92.9F2.252.252.252.252.252.252.252.252.252.252.25Tw32.3532.9133.4733.92534.3134.55534.7334.834.69534.4534.1Tn2727272727272727272727Q34.9138.5642.2245.1947.7049.3050.4450.9050.2148.6146.33续表3.1 101房间详细负荷计算表计算部位时刻89101112131415161718北墙K1.971.971.971.971.971.971.971.971.971.971.97F10.711110.7110.7110.7110.7110.7110.7110.7110.7110.7110.71Tlf32.132.432.632.933.133.233.233.233.13332.8Td2.32.32.32.32.32.32.32.32.32.32.3Tn2727272727272727272727Q156.13162.46162.46166.68173.01177.23179.34179.34179.34177.23175.12西墙K1.971.971.971.971.971.971.971.971.971.971.97F38.1638.1638.1638.1638.1638.1638.1638.1638.1638.1638.16Tlf35.836.537.33838.538.939.139.239.138.938.6Td2.22.22.22.22.22.22.22.22.22.22.2Tn2727272727272727272727Q2829.652882.282942.422995.043032.633062.703077.733085.253077.733062.703040.14南墙K1.971.971.971.971.971.971.971.971.971.971.97F17.2217.2217.2217.2217.2217.2217.2217.2217.2217.2217.22Tlf34.935.335.73636.136.236.236.135.935.635.3Td1.61.61.61.61.61.61.61.61.61.61.6Tn2727272727272727272727Q322.27335.84349.41359.59362.98366.37366.37362.98356.20346.02335.84东墙K1.971.971.971.971.971.971.971.971.971.971.97F21.1621.1621.1621.1621.1621.1621.1621.1621.1621.1621.16Tlf38.238.438.538.638.538.438.23837.637.336.9Td2.22.22.22.22.22.22.22.22.22.22.2Tn2727272727272727272727Q558.58566.92571.09575.26571.09566.92558.58550.24533.57521.07504.39西窗K2.92.92.92.92.92.92.92.92.92.92.9F7.27.27.27.27.27.27.27.27.27.27.2Tw32.3532.9133.4733.92534.3134.55534.7334.834.69534.4534.1Tn2727272727272727272727Q111.71123.40135.09144.59152.63157.75161.40162.86160.67155.56148.25续表3.1 101房间详细负荷计算表计算部位时刻89101112131415161718东窗K2.92.92.92.92.92.92.92.92.92.92.9F3.63.63.63.63.63.63.63.63.63.63.6Tw32.3532.9133.4733.92534.3134.55534.7334.834.69534.4534.1Tn2727272727272727272727Q55.8561.7067.5572.3076.3278.8780.7081.4380.3477.7874.12南门K2.5022.5022.5022.5022.5022.5022.5022.5022.5022.5022.502F8.78.78.78.78.78.78.78.78.78.78.7Tw32.3532.9133.4733.92534.3134.55534.7334.834.69534.4534.1Tn2727272727272727272727Q116.46128.65140.84150.74159.12164.45168.26169.79167.50162.17154.55屋顶K1.2721.2721.2721.2721.2721.2721.2721.2721.2721.2721.272F92.8892.8892.8892.8892.8892.8892.8892.8892.8892.8892.88Tlf46.747.547.847.747.246.445.444.343.141.840.6Td2.22.22.22.22.22.22.22.22.22.22.2Tn2727272727272727272727Q2587.342681.852717.292705.482646.412551.892433.752303.792162.022008.431866.66人单位负荷125125125125125125125125125125125人数2020202020202020202020Q25002500250025002500250025002500250025002500照明单位负荷1111111111111111111111面积136.08136.08136.08136.08136.08136.08136.08136.08136.08136.08136.08Q1496.881496.881496.881496.881496.881496.881496.881496.881496.881496.881496.88设备单位负荷55555555555面积136.08136.08136.08136.08136.08136.08136.08136.08136.08136.08136.08Q680.4680.4680.4680.4680.4680.4680.4680.4680.4680.4680.4新风冷负荷人数2020202020202020202020hw8383838383838383838383hn6161616161616161616161空气密度1.21.21.21.21.21.21.21.21.21.21.2Q44004400440044004400440044004400440044004400负荷小结Q总18659.119195.419544.419547.619391.319818.520332.520402.720066.619325.817919.3湿负荷W572572572572572572572572572572572最大负荷出现在15点,为20.403KW4.风机盘管选型根据各房间冷负荷以及王牌冷气产品手册,选择风机盘管,并汇总如下:表4.1 风机盘管选型汇总表房间负荷湿负荷热湿比温差hnho送风量全冷量盘管型号单位Wg/sKg/hKJ/KgKJ/KgKg/sKWKCR-1012040572.02.05990886050.82.21720.403400C 4台1027252171.60.621173986051.30.8327.252800C 1台103307128.60.102982786052.90.4333.071400C 1台104160810086053.62.51316.081400C 4台1054191114.40.411017686050.90.4614.191400C 1台1067455171.60.621206886051.40.8677.455800C 1台1074456286.01.03432886042.00.2484.456500C 1台108363257.20.211763886052.20.4663.632400C 1台10913176286.01.031279786051.51.55013.176800C 2台1104915171.60.62795686049.70.4774.915500C 1台1114462171.60.62722386049.20.4134.462500C 1台1124462171.60.62722386049.20.4134.462500C 1台1134348171.60.62703886049.00.3954.348500C 1台114228885.80.31740786049.30.2142.288300C 1台115311628.60.103026486052.90.4393.116400C 1台116357628.60.103473286053.00.5113.576400C 1台201965557.20.214688786053.21.4209.655500C 2台202795057.20.213860786053.01.1367.95400C 2台203362157.20.211758486052.20.4643.621400C 1台204336557.20.211634186052.10.4263.365400C 1台20512099286.01.031175186051.41.40712.099800C 2台2069966114.40.412419986052.71.3659.966500C 2台207287557.20.211396286051.80.3512.875300C 1台2084462171.60.62722386049.20.4134.462500C 1台2094348171.60.62703886049.00.3954.348500C 1台210228885.80.31740786049.30.2142.288300C 1台301939184290.015.44608186047.77.63693.9181000C 10台3029092114.40.412207786052.61.2299.0921000C 1台30310115171.60.621637486052.11.28010.115600C 2台30414772286.01.031434786051.91.82614.772800C 2台续表4.1 风机盘管选型汇总表房间负荷湿负荷热湿比温差hnho送风量全冷量盘管型号单位Wg/sKg/hKJ/KgKJ/KgKg/sKWKCR-30511628114.40.412823486052.81.61511.628600C 2台306305457.20.211483186051.90.3773.054400C 1台5.水系统设计5.1水系统方案的确定水管布置采用垂直异程,水平异程(三楼会议室采用同程),水系统选择闭式等温变流量的形式。利用:进出冷水机组的主管道之间的压差旁通阀通过调节水量来适应负荷变化。末端风机盘管或新风机组回水管上采用电动二通阀调节水量来调节风机盘的冷量。5.2管路的布置和管径的确定风机盘管的供、回、凝水管路(见图纸)。冷冻水供回水管150.3651.50200.65801.60250.801001.80321.001252.00401.151502.003.00501.355.3 凝结水管设计风机盘管机组、整体式空调器、组合式空调机组等运行过程中产生的冷凝水,必须及时予以排走。排放冷凝水管道的设计,应注意以下事项:(1)沿水流方向,水平管道应保持不小于0.001的坡度,且不允许有积水部位。(2)冷凝水管道宜采用聚乙烯塑料管和镀锌钢管,不宜采用焊接钢管。(3)为了防止冷凝水管道表面产生结露,必须进行防结露验算。聚乙烯塑料管时,一般可以不必进行防结露的保温和隔汽处理;采用镀锌钢管时,一般应进行防结露验算,通常应设置保温层。(4)冷凝水立管的顶部,应设计通向大气的透
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
评论
0/150
提交评论