文档简介
摘 要空调设计主要是对室内热环境、空气品质进行设计,但这必须在充分了解建筑对暖通空调的要求和暖通空调系统及设备对建筑及其它设施的影响的基础上进行设计。本设计是xx设计,针对该宾馆的功能和特点,以及该地气象条件和空调要求,参考有关文献资料确定了设计方案。本建筑没有地下室,没有合适的地方放置较大的机组,所以不能用全空气系统;设计采用风机盘管加新风系统,每层设有新风机组,可以由同层的新风机组送入室内,风机盘管承担室内的冷热负荷。水系统采用水平同程式,竖直异程式,这种水系统具有结构简单初投资少,管路不容易产生污垢和腐蚀。关键字: 空调系统,冷热负荷,水系统,风机盘管加新风系统AbstractAir conditioning design is mainly for indoor thermal environment, air quality, the requirements for hvac and hvac systems and equipment for building and other facilities influence is conducted on the basis of design.This design is, according to the characteristics and functions of the hotel. As well as the meteorological conditions and air conditioning requirements refer to the related literature determines the design scheme. This building without the basement, no suitable place to place larger units,so you cant use the air system, design adopt fan-coil unit plus fresh air system. Each layer has air units, by the same air units into the interior, fan coil undertake indoor heating load. Water system using level with the program, the vertical different programs, the water system has simple structure, initial investment, piping not easily produce dirt and corrosion.Keywords: Air conditioning system, Heat load,Water system, Fan coil systems.目 录前 言第一章 气象资料1.1 工程名称及概况:31.2 气象资料:31.3 动力资料:31.4 土建资料:3第二章 负荷计算2.2 冬季空调热负荷计算:62.3 夏季空调湿负荷计算12第三章 确定送风状态及送风量3.1 风机盘管机组新风供给方式的确定143.2 新风处理状态的确定,总风量及风机盘管风量的确定143.3 夏季室内新风量的确定:153.4 冬季送风状态及送风量173.5夏季空气处理方案:173.6 冬季空气处理方案:183.7 以一层贵宾接待室为例计算送风量、新风量,确定送风状态点193.8 确定餐厅和卫生间的排风量20第四章 空气处理方案的确定 第五章 空气处理设备选择 5.1 风机盘管的选择225.2 新风处理机组的选择:每层一台新风处理机组24第六章 气流组织确定 第七章 送回风道的布置及水力计算 7.1 水力计算的目的277.2 风管水力计算的特点287.3 风管水力计算方法29第九章 空调系统的消声 9.1 空调系统的噪声源439.3 消声措施449.4 空调系统中消声器消声量的确定4510.1 概述4610.2 减振器使用应注意的问题4610.3 各种减振措施的使用要求4711.1 防火、防烟分区的划分4811.2 防火阀的设置4811.3 自然排烟系统设计4911.4 机械排烟系统设计50第十二章 空调系统的管材及附件12.1 空调系统的管材5212.2 空调系统的附件52第十三章 空调系统的保温与防腐13.1 空调系统的保温5313.2. 空调系统的防腐54结 论 错误!未定义书签。参考文献 55谢 辞 错误!未定义书签。附录附录一 国内部分民用建筑空调冷负荷概算值 附录二 部分民用建筑空调冷负荷的概算指标 附录三 民用建筑空调系统风速的选用 附录四 不同噪声要求下风管推荐风速 前 言本设计的课题是:XXX空调设计。 设计的主要目的是通过实际的工程设计更加深刻理解学过的基础理论和专业知识,是一个理论联系实际的过程,以便在以后的实际工作中解决实际出现的各种问题。通过这一环节来增强自己的理论知识,加强我们对暖通空调设计现状和未来发展趋势的了解,方便我们以后的学习和工作。随着国民经济的发展和人民物质文化水平的不断提高,空调的应用以不再限于必要的工艺过程所需的环境控制和居住建筑室内创造舒适的环境,而是越来越普及寻常百姓家,成为提高他们生活质量的一部分。空气调节(Air Conditioning)的意义在于“使空气达到所要求的状态”或“使空气处于于正常状态”。据此,一个内部受控的空气环境,一般是指在某一特定空间内,对空气温度、湿度、空气流动及清洁度进行人工调节,以满足人体舒适和工艺生产过程的要求。现代技术发展手段有时还要求对空气的压力、成分、气味及噪声等进行调节与控制。由此可见,采用技术手段创造并保持满足一定要求的空气环境,乃是空气调节的任务。本宾馆通过设计采用风机盘管加新风系统形式,给各个房间提供适宜的温度,湿度等,满足人们舒适性要求,并且可以充分利用建筑物的余热,在节能方面更为优越。在选择设备时,在满足各个指标的情况下,应选择功率相对较小的设备,以使电能消耗降低到相对较低状态。并且节能建筑是以后建筑的大趋势,而暖通设备在建筑的节能方面又占有相当大的比重,随着能源的日趋紧张,在满足建筑物用途的基础上,应尽量作到节约能源。空调负荷在建筑物的整体能耗中占有相当大的比例,约为5070%,降低空调的能耗对建筑物的节能很重要的作用。由于建筑本身功能性房间较多,本设计除一楼大厅外的所有屋均采用风机盘管加新风机组系统。选用风机盘管系统具有以下优点:(1)布置灵活性大,节能效果好,各房间能根据室内负荷情况单独调节温湿度,房间不使用时可以关掉机组,不影响其他房间的使用;(2)各空调房间互不相通,不会相互污染;(3)节省运行费用,运行费用与单风道系统相比约低20%30%,比诱导器低10%20%,而综合投资费用大体相同,甚至略低;(4)可以承担80%的室内负荷,与全空气系统相比可节省空间;(5)只需要新风机房,机房面积小,风机盘管可以安装在空调房间内;(6)机组定型化、规格化、易于选择安装,安装投产较快;(7)使用寿命长。一楼大堂是贯穿一二层的,高十米、面积292,使用侧送和下送都不能达到工作区,即使在一层单设全空气系统,下送也不能达到舒适性空调的要求并且费用很高。最终选择在大堂四面安放柜式空调,这种既美观也能达到要求。每层均设一台新风机组,房间噪声太大,舒适性就会下降,为了降低噪声,新风机组后设置消声器,水系统采用同程式系统。为了降低能源损耗,冷却水和冷冻水管道均做保温。在设计过程中,曾广泛咨询过各位专业老师,给本设计提供了宝贵意见,也得到很多同学的帮助与支持,在此一并致谢。限于实践经验的不足,本设计存在一定的缺点和错误,望各位老师指正。第一章 原始资料1.1 工程名称及概况:本设计为XXX空调设计。建筑物共八层,建筑面积6885.2。1.2 气象资料:1. 冬季室外参数:室外计算干球温度=-26, 室外计算相对湿度=74%2. 夏季室外参数:室外计算干球温度=30.5,室外计算相对湿度=66%3. 冬季室内参数值:=20(客房及其他功能性房间),=50%,v0.2m/s 4. 夏季室内参数值:=26(客房及其他功能性房间),=55%,v0.3m/s5. 冬季室内参数值:=18(大厅、自助餐厅、卫生间、楼梯间),=50%,v0.2m/s 6. 夏季室内参数值:=25(大厅、自助餐厅、卫生间、楼梯间),=55%,v0.3m/s1.3 动力资料:1. 冷源:冷水机组进水温度7,回水温度12,温差=52. 热源:0.8Mpa饱和蒸汽,(由锅炉房供给)3. 水源: 城市自来水。4. 电源:220/380v交流电1.4 土建资料:1. 外墙体: 根据建筑条件图,按空调负荷专计算表7号I型墙计算2. 内墙体: =200mm红砖抹灰3. 屋面: 根据建筑条件图,(见空调冷负荷计算表6号型结构)4. 门窗: 窗玻璃采用双层3mm厚普通玻璃,客房内遮阳类型为白布帘,双层钢窗有效面积系数0.755. 层高: 一二楼层高5.0 m,三七楼层高3.5m,八楼层高4.8m第二章 负荷计算2.1 夏季空调冷负荷逐时计算:与计算热负荷同,同样每层以不同功能的典型房间为例,其他房间以次面积冷指标计算。以下叙述各项冷负荷的计算方法,然后列表计算。1. 外墙冷负荷本设计墙体属空调负荷计算表中的7号I型墙,外墙传热系数为K=0.99W/.由表3-3(外墙冷负荷计算温度t1表)查的不同朝向的t1值,并由表3-4(地点修正值)查得长春的地点修正值,得到修正后的温度t1。按各朝向外墙面积计算出外墙逐时冷负荷见表2-1。计算式为 (1-2)式中: 外墙瞬变传热引起的冷负荷,W。 外墙的面积,。 外墙的传热系数W/. oC。 室内设计空调温度,oC。外墙的冷负荷计算温度的逐时值,oC。地点修正值,oC。 本设计在计算外墙冷负荷时同样以上述房间为例计算不同朝向的外墙冷负荷。其它房间外墙冷负荷则用平均面积冷指标计算。 2. 屋面冷负荷本设计中屋面类型属空调冷负荷计算表6号III型结构,传热系数K=1.15 W/.由表(屋面冷负荷计算温度tl)查得III型的逐时值,再由表3-5查得长春的地点修正值,两者相加即为屋面冷负荷计算温度。公式同(1-2)。3. 玻璃窗瞬变传热引起的冷负荷该宾馆建筑物的所有外窗均系双层钢窗,查空调负荷计算表该种窗的传热系数K=3.12 W/m2oC. 由空调负荷计算表表3-10中查得玻璃窗传热系数的修正值为1.2。由表3-11(玻璃窗冷负荷计算温度表)可查得窗玻璃的逐时计算温度值tl,再由表3-12查得长春玻璃窗的地点修正值td=-4,则两者相加即为玻璃窗的逐时计算温度。计算式为 (1-3)式中: 玻璃窗瞬变传热引起的冷负荷,W。 F外窗的面积,。 外墙的传热系数W/. 室内设计空调温度,oC。外墙的冷负荷计算温度的逐时值,oC。地点修正值,oC。4. 透过玻璃进入的日射得热引起的冷负荷 玻璃窗为3mm普通玻璃,由空调负荷计算表表2-4中查得窗户的有效面积系数为0.75,由表2-2查得Cs=1.00,又由于有白色内遮阳窗帘,cn=0.50。因而cz=0.501.00=0.50,因长春的地理纬度为北区,由表2-1查得Dj max:南向为345,东向为598,北向110,西向598各朝向无内遮阳的CCL值由表2-5查得。计算式为 式中: 玻璃窗日射得热引起的逐时冷负荷,W 窗玻璃的净面积, 冷负荷系数,窗玻璃的综合遮挡系数 日射得热因数的最大值,W/5. 人员引起的冷负荷按宾馆的性质可知人员应该属于极轻运动,查空调负荷计算表表4-3当室内温度为26 oC时每人散发的显热和潜热分别为61W和73W,全热为134W,由于室内的人员包括男子和女子,由空调负荷专刊表4-4取群居系数为0.96。 6. 照明引起的负荷由空调负荷计算表公式4-1 = 式中: 照明冷负荷镇流器耗功率系数灯罩隔离系数 照明灯具所需的功率,KW 照明负荷指数2.2 冬季空调热负荷计算:1. 墙体、地面、天棚、门窗形成的负荷可按供热要求计算。= (11)式中:围护结构的基本耗热量,W;围护结构的面积,m2围护结构的传热系数W/空调室外计算温度,见空调负荷计算表;空调房间冬季设计温度,客房取20、其余取18; 计算温度修正系数,取1.00(1) 本设计在计算热负荷时,以不同功能房间为例,其余房间的热负荷以整个建筑物平均面积热指标计算。(2) 暖通规范规定宜按下列规定的数值选用不同朝向的修正系数,北0,西、东-5,南-20%(3) 本设计建筑物为市区内宾馆,故风向修正为0。(4) 高度修正:当房间高度大于4m时,高出1m应附加2%,但总的附加率应不大于15%。房间高度小于4m不加修正。(5) 由于室内有正压控制,可不算门窗冷风侵入和渗入。但朝向修正照常。(6) 人员散热及灯光、设备散热应予以考虑。(7) 在空调设计中地带划分为两个地带。(8) 现以一层西南角贵宾接待室为例,其余功能性房间计算结果见下表西南角贵宾接待室热负荷计算:西外墙面积10.15-(2.222)=41.7,传热系数K=0.99W/(见空调负荷计算表)。室外计算温度tw=-26oC,室内计算温度tn=20oC,室内外计算温差为44oC,温差修正系数a=1.0,朝向修正-5,则耗热量Q1=1899W.西外窗面积8.8,传热系数3.744W/,室外计算温度tw= -26oC,室内计算温度tn=20oC,室内外计算温差为44oC,温差修正系数a=1.0,朝向修正-5%,耗热量Q1=1515.6W。其他外墙与外窗热负荷计算方法与此相同。该房间总耗热量Q=7262W。(8) 屋面热负荷的计算传热系数取1.15W/m2 oC(见空调负荷计算表第47页)空调热负荷计算表(一层)房间名称及方向围护结构面积传热系数室内计算温度供暖室外计算温度室内外计算温度差温差修正系数基本耗热量修正后耗热量高度修正围护结构耗热量朝向风向修正后耗热量ktntwtQXchXf1+Xch+XFQXhQ1m2w/m2. WWW一楼大厅(292.19m2)东外墙110.10.9918-264414794-0.100.954554.090.125100.6南外墙2280.999933-0.20.87946.047946西外墙110.10.994794-0.10.954554.094554.1东外窗13.23.7442175-0.10.952065.792313.7西外窗13.23.7442175-0.10.952065.792313.7南外窗17.63.7442899-0.20.82319.482597.8南外门11.256.43168-0.20.82534.42838.5地面96.50.471996011995.621995.6地面195.70.231980011980.381980.4小计面积指标:108.29 31640贵宾接待室(115.48m2)西外墙41.70.9920-264611899-0.100.951804.070.021840.1南外墙32.80.991494-0.20.81194.971218.9西外窗8.83.7441516-0.10.951439.791468.6南外窗7.23.7441240-0.20.8992.011011.9地面42.30.4791501914.526932.82地面73.180.2377401774.244789.73小计62.89 7262会议室(115.48m2)东外墙41.70.9918-264411899-0.100.951804.070.021840.1南外墙32.80.991429-0.20.81143.011165.9东外窗8.83.7441450-0.10.951377.191404.7南外窗7.23.7441240-0.20.8992.011011.9地面42.30.4791501914.526932.82地面73.180.2377401774.244789.73小计61.87 7145卫生间(48.8m2)东外墙30.50.9918-264411389-0.100.951319.520.021345.9北外墙340.991548011548.361579.3北外窗63.7441033011033.341054地面28.20.4761001609.684621.88地面20.60.2321801217.948222.31小计98.84 4823杂物间(21.35m2)北外墙17.50.9918-26441762001762.30.02777.55北外窗4.83.74479101790.733790.73地面80.4716501165.44165.44地面13.350.2313501135.102135.1小计面积指标:87.53 1869机房(67.14m2)北外墙57.50.9918-2644125050012504.70.022554.8北外窗123.7441977011976.831976.8地面230.4747601475.64475.64地面44.140.2344701446.697446.7小计面积指标:81.23 5454电梯前室(22.88m2)北外墙15.150.9918-26441660001659.9340.02673.13北外门3.66.41014011013.761013.8地面7.50.4715501155.1155.1地面15.380.2315601155.646155.65小计面积指标:87.31 1998厨房(53.69m2)北外墙44.50.9918-2644119380011938.420.021977.2北外窗83.7441318011317.891317.9地面17.80.4736801368.104368.1地面35.890.2336301363.207363.21小计面积指标:74.99 4026其余房(302.8m2)东外墙50.9918-26441218-0.100.95206.910.02211.05西外墙30.50.991329-0.10.951262.151262.2北外窗4.83.74479101790.733790.73东外门36.4845-0.10.95802.56818.61北外墙180.9978401784.08799.76地面102.60.472122012121.772121.8地面200.20.232026012026.022026小计面积指标:26.52 8030三层客房(32.4m2)西外墙28.350.9920-264611291-0.100.951226.5101251南外墙100.99455-0.20.8364.32371.61南外窗43.744689-0.20.8551.117562.14小计67.43 2185客房(31.2m2)东外墙27.30.9920-264611243-0.100.951181.0801204.7南外墙100.99455-0.20.8364.32371.61南外窗43.744689-0.20.8551.117562.14小计68.54 2138客房(32.4m2)东外墙28.350.9920-264611291-0.100.951226.5101251北外墙100.9945501455.4464.51北外窗43.74468901688.896702.67小计74.64 2418客房(32.4m2)北外墙100.9920-26461436001435.60435.6北外窗43.74465901658.944658.94小计面积指标:33.78 1095客房(32.4m2)南外墙100.9920-26461455-0.100.95432.630441.28南外窗43.744689-0.20.8551.117562.14小计30.97 1003八层客房(32.4m2)西外墙38.880.9920-264611771-0.100.951682.070.021715.7南外墙15.20.99692-0.20.8553.766564.84南外窗43.744689-0.20.8551.117562.14顶棚32.41.151714011713.961748.2小计141.70 4591办公室(44.8m2)东外墙22.080.9918-264411006-0.100.95955.2470.02974.35南外墙300.991366-0.20.81092.961114.8南外窗8.43.7441447-0.20.81157.351180.5顶棚44.81.152267012266.882312.2小计124.60 5582管理办公室(47.2m2)东外墙28.320.9918-264411290-0.100.951225.210.021249.7北外墙30.40.991384011384.421412.1北外窗83.7441378011377.791405.3顶棚47.21.152388012388.322436.1小计137.78 6503客房(33.6m2)北外墙15.20.9918-26441662001662.1120.02675.35北外窗43.74465901658.944658.94顶棚33.61.151700011700.161734.2小计面积指标:91.32 3068客房(32.4m2)南外墙15.20.9920-26461692-0.100.95657.5980.02670.75南外窗43.744689-0.20.8551.117562.14顶棚32.41.151714011713.961748.2小计92.01 2981 2.3 夏季空调湿负荷计算 因为本设计为宾馆空调设计,所以室内活动认为是轻度劳动,本设计只考虑人体散湿量,据空调负荷计算表散湿量式中: 式中:房间总散湿量g/h;房间一个人散湿量g/h简明空调设计手册;房间人数;群集系数。各房间负荷汇总列表如下表各房间负荷汇总表 房间名称面积m2冷负荷w热负荷m2冷负荷指标w/m2热负荷指标w/m2一层大堂292.18519583.0 31640.0 67.0 108.29贵宾接待室115.488197.1 15262.0 71.0 132.2厨房53.694848.2 4026.0 90.3 74.99机房67.145465.2 5453.8 81.4 81.23电梯前室37.172798.9 3245.3 75.3 87.31杂物间21.351460.3 1868.8 68.4 87.53卫生间48.83313.5 4613.6 67.9 94.54会议室114.5713221.4 6891.4 115.4 60.15其他屋335.5221641.1 8898.0 64.5 26.52小计1085.90580528.7 81898.8 二层多功能贵宾房1158165.0 15203.0 71.0 132.2配餐室27.281915.1 2327.0 70.2 85.3自助餐厅北191.614485.0 6472.2 75.6 33.78多功能贵宾房东南1159361.0 9341.5 81.4 81.23电梯前室37.172798.9 3245.3 75.3 87.31杂物间21.351460.3 1868.8 68.4 87.53卫生间48.83313.5 4613.6 67.9 94.54自助餐厅南207.6914434.5 6151.8 69.5 29.62小计763.8955933.2 49223.1 三、四层客房西南32.41441.8 2098.5 44.5 64.77客房东南32.41898.6 2133.2 58.6 65.84客房东北33.61680.0 2410.1 50.0 71.73客房北33.61135.0 1723.7 33.8 51.3客房南32.4959.7 1607.0 29.6 49.6其余南面241.387144.8 11972.4 29.6 49.6其余北面137.764656.3 7067.1 33.8 51.3电梯前室107.528096.3 9387.6 75.3 87.31杂物间845745.6 7352.5 68.4 87.53小计735.0632758.1 45752.2 五七层客房西南32.41441.8 2098.5 44.5 64.77主卧室64.83797.3 4266.4 58.6 65.84客房东北33.61680.0 2410.1 50.0 71.73客厅564558.4 4548.9 81.4 81.23客房北33.61135.0 1723.7 33.8 51.3客房南32.4959.7 1607.0 29.6 49.6其余南面230.586825.2 11436.8 29.6 49.6其余北面159.365386.4 8175.2 33.8 51.3电梯前室104.97899.0 9158.8 75.3 87.31小计747.6433682.7 45425.5 八层客房西南32.41979.6 4591.1 61.1 141.7办公室东南44.83866.2 5533.2 86.3 123.51管理办公室47.23596.6 6457.0 76.2 136.8办公室56.84623.5 4613.9 81.4 81.23客房北33.61872.5 3068.4 55.7 91.32客房南32.41607.0 2981.1 49.6 92.01其余南面230.5811436.8 21215.7 49.6 92.01其余北面159.368876.4 14552.8 55.7 91.32电梯前室104.97899.0 9579.5 75.3 91.32小计742.0445757.7 72592.5 第三章 确定送风状态及送风量空气调节系统一般由空气处理设备和空气输送管道以及空气分配装置组成,根据需要,它能组成许多不同形式的要求。本建筑为宾馆,各房间均为小空间结构,要求各房间能独立进行调控,因此宜采用风机盘管加新风系统3.1 风机盘管机组新风供给方式的确定 本设计采用单独的新风系统供给室内新风,把新风处理到室内的等焓线上,承担室内的负荷,这样就提高了该系统的调节和运转的灵活性3.2 新风处理状态的确定,总风量及风机盘管风量的确定 根据室内的in 线新风处理后的相对湿度和风机温升t即可定出新风处理后的机械露点L点,即L点和K点重合。过室内状态点n点做热湿比线线与=90%的交线,即为送风状态点O点,因为风机盘管系统用于舒适性空调,不受送风温差限制,故可采用较底的送风温度。故房间的风量 连接L,O两点到M点,使 式中: 新风量。Kg/s 风机盘管风量Kg/s 故房间总风量,而M即为风机盘管的出风状态点。3.3 夏季室内新风量的确定: 3.3.1 满足卫生要求:在人员长期停留的空调房间,由于人们呼出二氧化碳气体的增加,会逐渐破坏室内空气的正常成分,给人体带来不良的影响。因此在空调系统的送风量中,必须掺入含二氧化碳少的室外新风来稀释室内空气中的二氧化碳的含量,使之符合卫生标准的要求。人体在不同状态下的二氧化碳呼出量 工作状态CO2呼出量(L / h 人)CO2呼出量(g / h 人)安静时1319.5极轻的工作2233轻劳动3045中等劳动4669重劳动74111 二氧化碳允许浓度 表3-2房间性质CO2允许浓度(L / m3)CO2允许浓度( g / kg )小孩和病人停留的地方0.71.0人周期性停留的地方1.251.75人短期停留的地方2.03.0人长期停留的地方1.01.5在一般的城市和农村,室外空气中二氧化碳含量为0.50.75 g/kg根据以上条件,可利用确定全面通风量的基本原理,来消除二氧化碳所需要的新鲜空气量,可按规范确定;不论每人占用体积多少,新风量按大于等于30 m3/h人采用;对于人员密集的建筑物,每人占用的空间较小(不到10m3),但停留的时间较短,可分别按吸烟与不吸烟的情况,新风量以715 m3/h人计算,由于这类建筑物按此确定的新风量占总风量的百分比能达到,从而对冷量影响很大,所以在确定新风量时应十分慎重。3.3.2 补充局部排风量,以防房间产生负压因为本设计的建筑的局部排风主要在厕所,还有在且其排风量大,所以在厕所内放置排气扇。 当空调房间内有排风柜等局部排风装置时,为了不使空调房间产生负压,在系统中必须有相应的新风量来补尝排风量。 Lw = LP m3/h 供热通风与空调工程手册P196式中: Lw需要的新风量,m3/h; LP局部和全面排风量之和,m3/h;排风量的计算按换气次数计算: 次/ h 式中: 房间的换气次数,次/ h; 房间送风量,m3/h; 房间的体积,m3;3.3.3 保持空调房间正压要求一般情况下室内正压在5-10pa即可满足为了防止外界环境空气渗入空调房间,干扰室内温度,湿度或破坏室内的洁净度,需要使空调房间内部保持一定的正压值,即用增加一部分新风的方法,使室内空气高于外界压力,然后再让这部分多余的空气从房间门窗缝隙等不严密处审渗出去。室内的正压值P(PA)正常,相当于空气从房间缝隙渗出时阻力。空调房间正压值510Pa来计算。过大的正压不但没有必要,而且还降低了系统运行的经济性。可按下式计算从房间通过门缝、窗缝和其他缝隙渗入的风量,即需要补充的新风量Lw。 m3/h 供热通风与空调工程手册P233式中: 需要补充的新风量; 室内需要保证的正压值,H2O 取1.01972H2O; a,n 与严密程度有关的系数,n取1.5;a取5; 缝隙长度, m;其取值随门窗开启形式的不同而不同 根据上述三个要求取最大值;本设计房间内均为正压。3.4 冬季送风状态及送风量冬季通过围护结构的温差传热往往是由内向外传递,只有室内热源向室内散热,因此冬季室内余热往往比夏季少得多。而余湿量则冬夏季一般相同。这样,冬季房间的热湿比常小于夏季,也可能为负,所以空调送风温度往往接近或高于室温,由于送风时送风温差可以比夏季小,故空调送风量一般是先确定夏季送风量,再冬季可采取与夏季相同的风量。全年采取固定送风量是比较方便的,若少于夏季,可以提高送风温度但450C为宜,可以节约电能,尤其对较大的空调系统减少风量的经济意更为突出。3.5 夏季空气处理方案: 现在以一层贵宾接待室为例来确定送风状态和送风量1. 依据已知条件,定出室内状态点N。2. 依据计算的负荷Q=8.197KW和散湿量W=0.00056Kg/s,计算出房间的热湿比,过N点做出热湿比线3. 依据房间的温度控制精度及换气次数。定出送风温差,定出送风状态点,在没有特殊要求的场合下,尽量
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年离婚协议范文
- 2025年医疗安全自查报告
- 2025年廉洁从业警示教育心得体会
- 2025年电气工程师专业基础《供配电》真题及答案
- 2025年下半年广东云浮市机关事业单位招聘紧缺人才5人(第二批)易考易错模拟试题(共500题)试卷后附参考答案
- 长治市中医院透析新技术应用考核
- 2025年下半年广东中山市商务局拟聘用雇员易考易错模拟试题(共500题)试卷后附参考答案
- 阳泉市中医院科室综合竞争力评估
- 2025年下半年广东东莞市虎门镇国库支付中心招聘工程师4人易考易错模拟试题(共500题)试卷后附参考答案
- 2025年下半年平顶山宝丰县事业单位招考(13人)易考易错模拟试题(共500题)试卷后附参考答案
- 2025年家政服务人员劳动合同范本下载
- 2025年上海文化广场第三季度公开招聘工作人员笔试备考题库及答案解析
- 职业道德安全培训试题及答案解析
- 2025销售人员劳动合同模板
- 专业育婴师服务合同范本
- 经管课题申报书范文
- DB13-T 6180-2025 波纹钢装配式检查井设计技术导则
- UPS电源维护保养操作规范及要点
- 第2单元主题阅读(阅读策略+阅读)语文统编版六年级语文上册 教师版
- 《微生物资源在未来医药领域的应用》课件
- 2025至2030中国尿动力学设备及耗材行业产业运行态势及投资规划深度研究报告
评论
0/150
提交评论