LOW PEAK LPJ Dual Element Time Delay Fuses1 60 Amps Class J 600 Volt Form No LPJ 1 60 Page 1 of 3 Data Sheet 1006 Bussmann 10 2 02SB02295 2 38 0 03 63 35A to 60A 1 06 0 03 5 1A to 30A 81 0 03 2 25 0 03 Catalog Symbol LPJ SP Dual Element Time Delay 10 seconds minimum at 500 rated current Current Limiting Ampere Rating 1 to 60A Voltage Rating 600Vac or less 300Vdc or less Interrupting Rating 300 000A RMS Sym UL 100 000A dc Agency Information UL Listed Special Purpose Guide JFHR File E56412 CSA Certified 200 000 AIR Class J per CSA 22 2 No 248 8 Class 1422 02 File 53787 Meets all performance requirements of UL Standard 248 8 for Class J fuses Catalog Symbol and Ampere Ratings LPJ 1SPLPJ 3SPLPJ 7SPLPJ 25SP LPJ 1 SPLPJ 3 SPLPJ 8SPLPJ 30SP LPJ 1 fl SPLPJ 3 SPLPJ 9SPLPJ 35SP LPJ 1 SPLPJ 4SPLPJ 10SPLPJ 40SP LPJ 2SPLPJ 4 SPLPJ 12SPLPJ 45SP LPJ 2 SPLPJ 5SPLPJ 15SPLPJ 50SP LPJ 2 SP LPJ 5fl SPLPJ 17 SPLPJ 60SP LPJ 2 SPLPJ 6SPLPJ 20SP Carton Quantity and Weight AmpereCarton Weight RatingsQty Lbs Kg 1 30101 090 494 35 60101 780 808 Weight per carton General Information True dual element fuses with a minimum 10 second time delay at 500 overload Long time delay minimizes needless fuse openings due to temporary overloads and transient surges Can often be sized for back up protection against motor burnout from overload or single phasing if other overload protective devices fail High interrupting rating to safely interrupt overcurrents up to 300 000A High degree of current limitation due to the fast speed of response to short circuits Faster response to damaging short circuit currents than mechanical overcurrent protective devices Reduces let through thermal and magnetic forces in order to protect low withstand rated components Proper sizing provides no damage Type 2 coordinated protection for NEMA and IEC motor control in accordance with IEC Standard 947 4 1 Dual element fuses have lower resistance than ordinary fuses so they run cooler Lower watts loss reduces power consumption Unique dimensions assure that another class of fuse with a lesser voltage rating interrupting rating or current Iimiting ability cannot be substituted Space saving package for equipment down sizing Dimensional Data CE logo denotes compliance with European Union Low Voltage Directive 50 1000Vac 75 1500Vdc Refer to Data Sheet 8002 or contact Bussmann Application Engineering at 636 527 1270 for more information Recommended fuseblocks fuseholders for Class J 600V fuses See Data Sheets listed below Finger safe fuseholders 1152 Open fuseblocks 1114 Open pyramid fuseblocks 1108 LOW PEAK LPJ Dual Element Time Delay Fuses1 60 Amps Class J 600 Volt Form No LPJ 1 60 Page 2 of 3 Data Sheet 1006 Bussmann AMPERE RATING 1A 3A 6A 300 100 10 1 1 01 TIME IN SECONDS 10A 15A 30A 60A 1 000 10 1 CURRENT IN AMPERES 200 100 Time Current Characteristic Curves Average Melt 10 2 02SB02295 Bussmann Form No LPJ 1 60 Page 3 of 3 Data Sheet 1006 The only controlled copy of this Data Sheet is the electronic read only version located on the Bussmann Network Drive All other copies of this document are by definition uncontrolled This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications Bussmann reserves the right without notice to change design or construction of any products and to discontinue or limit distribution of any products Bussmann also reserves the right to change or update without notice any technical information contained in this bulletin Once a product has been selected it should be tested by the user in all possible applications LOW PEAK LPJ Dual Element Time Delay Fuses1 60 Amps Class J 600 Volt Current Limitation Curves 10 2 02SB02295 LOW PEAK LPJ Dual Element Time Delay Fuses70 to 600A Class J 600 Volt Form No LPJ 70 600 Page 1 of 3 Data Sheet 1007 Bussmann 10 8 03A03094 5 75 0 03 4 38 3 0 43 1 38 4 63 0 03 3 63 2 63 70A to 100A 28 75 1 13 0 03 13 1 43 1 13 28 19 1 63 0 03 110A to 200A Catalog Symbol and Ampere Ratings LPJ 70SPLPJ 125SPLPJ 250SPLPJ 500SP LPJ 80SPLPJ 150SPLPJ 300SPLPJ 600SP LPJ 90SPLPJ 175SPLPJ 350SP LPJ 100SPLPJ 200SPLPJ 400SP LPJ 110SPLPJ 225SPLPJ 450SP Dimensional Data Catalog Symbol LPJ SP Dual Element Time Delay 10 seconds minimum at 500 rated current Current Limiting Ampere Rating 70 to 600A Voltage Rating 600Vac or less Interrupting Rating 300 000A RMS Sym Agency Information UL Listed Special Purpose Guide JFHR File E56412 CSA Certified Class J per CSA C22 2 No 248 8 Class 1422 02 File 53787 0 600A rated 300Vdc and 20 KAIC Meets all performance requirements of UL Standard 248 8 for Class J fuses Carton Quantity and Weight AmpereCarton Weight RatingsQty Lbs Kg 70 10051 690 767 110 20054 211 910 225 40011 670 758 450 60012 801 270 Weight per carton General Information True dual element fuses with a minimum 10 second time delay at 500 overload Long time delay minimizes needless fuse openings due to temporary overloads and transient surges Can often be sized for back up protection against motor burnout from overload or single phasing if other overload protective devices fail High interrupting rating to safely interrupt overcurrents up to 300 000A High degree of current limitation due to the fast speed of response to short circuits Faster response to damaging short circuit currents than mechanical overcurrent protective devices Reduces let through thermal and magnetic forces in order to protect low withstand rated components Proper sizing provides no damage Type 2 coordinated protection for NEMA and IEC motor control in accordance with IEC Standard 947 4 1 Dual element fuses have lower resistance than ordinary fuses hence they run cooler Lower watts loss reduces power consumption Unique dimensions assure that another class of fuse with a lesser voltage rating interrupting rating or current Iimiting ability cannot be substituted Space saving package for equipment down sizing CE logo denotes compliance with European Union Low Voltage Directive 50 1000Vac 75 1500Vdc Refer to Data Sheet 8002 or contact Bussmann Application Engineering at 636 527 1270 for more information 450A to 600A 225A to 400A LOW PEAK LPJ Dual Element Time Delay Fuses70 600A Class J 600 Volt Form No LPJ 70 600 Page 2 of 3 Data Sheet 1007 Bussmann AMPERE RATING 80A 300 100 10 1 1 01 TIME IN SECONDS 100A 125A 200A 250A 400A 600A 10 000 1 000 100 CURRENT IN AMPERES 200 Time Current Characteristic Curves Average Melt Recommended fuseblocks for Class J 600V fuses See Data Sheet 1114 10 8 03A03094 Bussmann Current Limitation Curves LOW PEAK LPJ Dual Element Time Delay Fuses70 600A Class J 600 Volt Form No LPJ 70 600 Page 3 of 3 Data Sheet 1007 The only controlled copy of this Data Sheet is the electronic read only version located on the Bussmann Network Drive All other copies of this document are by definition uncontrolled This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications Bussmann reserves the right without notice to change design or construction of any products and to discontinue or limit distribution of any products Bussmann also reserves the right to change or update without notice any technical information con tained in this bulletin Once a product has been selected it should be tested by the user in all possible applications 10 8 03A03094 LOW PEAK LPJ SPI Dual Element Time Delay Fuses6 60 Amps Class J 600 Volt Form No LPJ SPI 6 60 Page 1 of 3 Data Sheet 1062 Bussmann 8 26 04SB04295 2 38 0 03 63 35A to 60A 1 06 0 03 5 1A to 30A 81 0 03 2 25 0 03 Catalog Symbol LPJ SPI Dual Element Time Delay 10 seconds minimum at 500 rated current Current Limiting Ampere Rating 6 to 60A Voltage Rating 600Vac or less 300Vdc or less 35 60A Interrupting Rating 300 000A RMS Sym UL 100 000A dc Agency Information UL Listed Special Purpose Guide JFHR File E56412 CSA Certified 200 000 AIR Class J per CSA 22 2 No 248 8 Class 1422 02 File 53787 Meets all performance requirements of UL Standard 248 8 for Class J fuses Carton Quantity and Weight AmpereCarton Weight RatingsQty Lbs Kg 6 30101 090 494 35 60101 780 808 Weight per carton General Information Permanent fuse Indication True dual element fuses with a minimum 10 second time delay at 500 overload Long time delay minimizes needless fuse openings due to temporary overloads and transient surges Can often be sized for back up protection against motor burnout from overload or single phasing if other overload protective devices fail High interrupting rating to safely interrupt overcurrents up to 300 000A High degree of current limitation due to the fast speed of response to short circuits Faster response to damaging short circuit currents than mechanical overcurrent protective devices Reduces let through thermal and magnetic forces in order to protect low withstand rated components Proper sizing provides no damage Type 2 coordinated protection for NEMA and IEC motor control in accordance with IEC Standard 947 4 1 Dual element fuses have lower resistance than ordinary fuses so they run cooler Lower watts loss reduces power consumption Unique dimensions assure that another class of fuse with a lesser voltage rating interrupting rating or current Iimiting ability cannot be substituted Space saving package for equipment down sizing Dimensional Data CE logo denotes compliance with European Union Low Voltage Directive 50 1000Vac 75 1500Vdc Refer to Data Sheet 8002 or contact Bussmann Application Engineering at 636 527 1270 for more information Recommended fuseblocks fuseholders for Class J 600V fuses See Data Sheets listed below Finger safe fuseholders 1152 Open fuseblocks 1114 Open pyramid fuseblocks 1108 For non indicating version the LPJ SP is available See Data Sheet 1006 Catalog Symbol and Ampere Ratings LPJ 6SPILPJ 10SPILPJ 20SPILPJ 40SPI LPJ 7SPILPJ 12SPILPJ 25SPILPJ 45SPI LPJ 8SPILPJ 15SPILPJ 30SPILPJ 50SPI LPJ 9SPILPJ 17 SPILPJ 35SPILPJ 60SPI LOW PEAK LPJ SPI Dual Element Time Delay Fuses6 60 Amps Class J 600 Volt Form No LPJ SPI 6 60 Page 2 of 3 Data Sheet 1062 Bussmann Time Current Characteristic Curves Average Melt 8 26 04SB04295 AMPERE RATING 6A 300 100 10 1 1 01 TIME IN SECONDS 10A 15A 30A 60A 1 000 10 1 CURRENT IN AMPERES 200 100 Bussmann Form No LPJ SPI 6 60 Page 3 of 3 Data Sheet 1062 The only controlled copy of this Data Sheet is the electronic read only version located on the Bussmann Network Drive All other copies of this document are by definition uncontrolled This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications Bussmann reserves the right without notice to change design or construction of any products and to discontinue or limit distribution of any products Bussmann also reserves the right to change or update without notice any technical information contained in this bulletin Once a product has been selected it should be tested by the user in all possible applications LOW PEAK LPJ SPI Dual Element Time Delay Fuses6 60 Amps Class J 600 Volt Current Limitation Curves 8 26 04SB04295 LOW PEAK LPJ SPI Dual Element Time Delay Fuses70 to 600A Class J 600 Volt Form No LPJ 70 600 Page 1 of 3 Data Sheet 1063 Bussmann 8 26 04SB04295 Dimensional Data Catalog Symbol LPJ SPI Dual Element Time Delay 10 seconds minimum at 500 rated current Current Limiting Ampere Rating 70 to 600A Voltage Rating ac 600V or less dc 300V or less Interrupting Rating ac 300 000A RMS Sym dc 100 000A Agency Information UL Listed Special Purpose Guide JFHR File E56412 CSA Certified Class J per CSA C22 2 No 248 8 Class 1422 02 File 53787 Meets all performance requirements of UL Standard 248 8 for Class J fuses General Information Permanent replacement fuse indication True dual element fuses with a minimum 10 second time delay at 500 overload Long time delay minimizes needless fuse openings due to temporary overloads and transient surges Can often be sized for back up protection against motor burnout from overload or single phasing if other overload protective devices fail High interrupting rating to safely interrupt overcurrents up to 300 000A High degree of current limitation due to the fast speed of response to short circuits Faster response to damaging short circuit currents than mechanical overcurrent protective devices Reduces let through thermal and magnetic forces in order to protect low withstand rated components Proper sizing provides no damage Type 2 coordinated protection for NEMA and IEC motor control in accordance with IEC Standard 947 4 1 Dual element fuses have lower resistance than ordinary fuses hence they run cooler Lower watts loss reduces power consumption Unique dimensions assure that another class of fuse with a lesser voltage rating interrupting rating or current Iimiting ability cannot be substituted Space saving package for equipment down sizing CE logo denotes compliance with European Union Low Voltage Directive 50 1000Vac 75 1500Vdc Refer to Data Sheet 8002 or contact Bussmann Application Engineering at 636 527 1270 for more information Recommended fuseblocks for Class J 600V fuses See Data Sheet 1114 For non indicating version the LPJ SP is available See Data Sheet 1007 5 75 0 03 4 38 3 0 43 1 38 4 63 0 03 3 63 2 63 70A to 100A 28 75 1 13 0 03 13 1 43 1 13 28 19 1 63 0 03 110A to 200A 450A to 600A 225A to 400A Catalog Symbol and Ampere Ratings LPJ 70SPILPJ 125

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论