brocade 光纤交换机改成ag模式.doc_第1页
brocade 光纤交换机改成ag模式.doc_第2页
brocade 光纤交换机改成ag模式.doc_第3页
brocade 光纤交换机改成ag模式.doc_第4页
brocade 光纤交换机改成ag模式.doc_第5页
免费预览已结束,剩余1页可下载查看

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

打开交换机端口,查看ip地址首先等入交换机 ip 192.168.70.129brocade8Gb:USERID switchshowswitchName: brocade8GbswitchType: 73.6switchState: Online switchMode: NativeswitchRole: PrincipalswitchDomain: 1switchId: fffc01switchWwn: 10:00:00:27:f8:66:79:03zoning: OFFswitchBeacon: OFFIndex Port Address Media Speed State Proto= 0 0 010000 id N8 No_Light FC Disabled (Persistent) 1 1 010100 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:20 2 2 010200 cu N8 Online FC F-Port 10:00:00:90:fa:17:dd:d2 3 3 010300 cu N8 Online FC F-Port 10:00:00:90:fa:17:db:a0 4 4 010400 cu N8 Online FC F-Port 10:00:00:90:fa:17:33:1a 5 5 010500 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:28 6 6 010600 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:80 7 7 010700 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:48 8 8 010800 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:02 9 9 010900 cu N8 Online FC F-Port 10:00:00:90:fa:17:dd:2a 10 10 010a00 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:e6 11 11 010b00 cu N8 Online FC F-Port 10:00:00:90:fa:17:30:dc 12 12 010c00 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:10 13 13 010d00 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:0a 14 14 010e00 cu N8 Online FC F-Port 10:00:00:90:fa:17:33:82 15 15 010f00 id N8 No_Light FC Disabled (Persistent) 16 16 011000 - N8 No_Module FC Disabled (Persistent) 17 17 011100 - N8 No_Module FC Disabled (Persistent) 18 18 011200 - N8 No_Module FC Disabled (Persistent) 19 19 011300 - N8 No_Module FC Disabled (Persistent)brocade8Gb:USERID version 查看版本Kernel: 2.6.14.2 Fabric OS: v6.4.2b4Made on: Thu Aug 9 21:10:00 2012Flash: Fri Mar 15 14:33:49 2013BootProm: 1.0.9brocade8Gb:USERID switchdisable 关闭交换机模式brocade8Gb:USERID ag -modeenable开启ag模式WARNING: Access Gateway mode changes the standard behavior of the switch. Please check Access Gateway Administrators Guide before proceeding.Enabling agmode will remove all the configuration data on the switchincluding zoning configuration and security database. Please backup yourconfiguration using configupload.This operation will reboot the switch.Do you want to continue? (yes, y, no, n): no y这个时候会提示重新启动Access Gateway mode was enabled successfullySwitch is being rebooted.客户只有在0号段口上有一根尾纤,这里做的都是把端口全部绑定在0号口上由于关闭了交换机模式,交换机上无法再显示wwn号了.brocade8Gb:USERID switchshowswitchName: brocade8GbswitchType: 73.6switchState: Online switchMode: Access Gateway ModeswitchWwn: 10:00:00:27:f8:66:bd:d8switchBeacon: OFFIndex Port Address Media Speed State Proto= 0 0 010000 id N8 No_Light FC 1 1 010100 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 2 2 010200 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 3 3 010300 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 4 4 010400 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 5 5 010500 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 6 6 010600 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 7 7 010700 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 8 8 010800 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 9 9 010900 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 10 10 010a00 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 11 11 010b00 cu AN No_Sync FC 12 12 010c00 cu AN No_Sync FC 13 13 010d00 cu AN No_Sync FC 14 14 010e00 cu AN No_Sync FC 15 15 010f00 id N8 No_Light FC 16 16 011000 - N8 No_Module FC 17 17 011100 - N8 No_Module FC 18 18 011200 - N8 No_Module FC 19 19 011300 - N8 No_Module FC brocade8Gb:USERID LOCAL : SEND0: window-change (rows: 24, cols: 80) brocade8Gb:USERID ag mapshow 这个是默认的设置N_Port Configured_F_Ports Current_F_Ports Failover Failback PG_ID PG_Name- 0 1;2 None 1 1 0 pg0 15 3;4 None 1 1 0 pg0 16 5;6;7 None 1 1 0 pg0 17 8;9 None 1 1 0 pg0 18 10;11 None 1 1 0 pg0 19 12;13;14 None 1 1 0 pg0-brocade8Gb:USERID ag -mapdel 15 3;4F_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID ag -mapdel 16 5;6;7F_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID ag -mapdel 17 8;9 F_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID ag -mapdel 18 10;11F_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID ag -mapdel 19 12;13;14F_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID ag -mapadd 03;4;5;6;7;8;9;10;11;12;13;14要注意空格USAGE: ag -mapadd Adds specified list of F_Ports to the mapping for a given N_Port. It will add the current to the existing mappings if any for that N_Port. An F_Port cannot be mapped to more than one N_Port at the same timebrocade8Gb:USERID ag -mapadd 03;4 USAGE: ag -mapadd Adds specified list of F_Ports to the mapping for a given N_Port. It will add the current to the existing mappings if any for that N_Port. An F_Port cannot be mapped to more than one N_Port at the same timebrocade8Gb:USERID ag -mapadd 0 3;4;5;6;7;8;9;10;11;12;13;14F_Port to N_Port mapping has been updated successfully 成功brocade8Gb:USERID ag -mapshowN_Port Configured_F_Ports Current_F_Ports Failover Failback PG_ID PG_Name- 0 1;2;3;4;5; None 1 1 0 pg0 6;7;8;9;10; 11;12;13;14 15 None None 1 1 0 pg0 16 None None 1 1 0 pg0 17 None None 1 1 0 pg0 18 None None 1 1 0 pg0 19 None None 1 1 0 pg0brocade8Gb:USERID switchshowswitchName: brocade8GbswitchType: 73.6switchState: Online switchMode: Access Gateway ModeswitchWwn: 10:00:00:27:f8:66:c1:ddswitchBeacon: OFFIndex Port Address Media Speed State Proto= 0 0 010000 id N8 No_Light FC 1 1 010100 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 2 2 010200 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 3 3 010300 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 4 4 010400 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 5 5 010500 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 6 6 010600 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 7 7 010700 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 8 8 010800 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 9 9 010900 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 10 10 010a00 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 11 11 010b00 cu AN No_Sync FC 12 12 010c00 cu AN No_Sync FC 13 13 010d00 cu AN No_Sync FC 14 14 010e00 cu AN No_Sync FC 15 15 010f00 id N8 No_Light FC 16 16 011000 - N8 No_Module FC 17 17 011100 - N8 No_Module FC 18 18 011200 - N8 No_Module FC 19 19 011300 - N8 No_Module FCbrocade8Gb:USERID portenable 0 打开端口 或是switchenablebrocade8Gb:USERID switchshowswitchName: brocade8GbswitchType: 73.6switchState: Online switchMode: Access Gateway ModeswitchWwn: 10:00:00:27:f8:66:bd:d8switchBeacon: OFFIndex Port Address Media Speed State Proto= 0 0 010000 id N4 Online FC N-Port 20:0c:00:0d:ec:c1:f1:41 0x7a002b 1 1 010100 cu N8 Online FC F-Port 10:00:00:90:fa:17:32:fe 0x7a003d 2 2 010200 cu N8 Online FC F-Port 10:00:00:90:fa:17:db:ea 0x7a003e 3 3 010300 cu N8 Online FC F-Port 10:00:00:90:fa:17:33:f0 0x7a0

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论