




已阅读5页,还剩3页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
xPON光模块简易故障判断指导书xPON光模块简易故障判断指导书(仅供内部使用)Huawei Technologies Co., Ltd.华为技术有限公司All rights reserved版权所有 侵权必究1 EPON 光模块简易判断1.1 通过命令行查询光模块信息MA5600T(config-if-epon-0/12)#display port state 0 - F/S/P 0/12/0 Optical Module status Online Port state Offline low-time-lapse - Last down cause LOS Last up time 2011-10-8 10:17:53+08:00 Last down time 2011-10-8 10:28:04+08:00 Available bandwidth(Kbps) 1000000 Laser state Normal /有问题的光模块可能显示Failed Temperature(C) 39 /070度OK,且与其他端口的数值接近 TX Bias current(mA) 46 /070mA ok,可与附近同类型的光模块进行对比 Supply Voltage(V) 3.24 /在3.03.6V间ok TX power(dBm) 4.89 /2.57之间ok (PX20+) Illegal rogue ONT Inexistent Max rate(Kbps) 1300000 Max Distance(Km) 20 Wave Length(nm) 1490 /如果是1310,表明错将ONT光模块插在OLT端口,需要更换广模块 Fiber type Single Mode Signal detect - TX fault Normal Identifier SFP Ext.Identifier GBIC/SFP function is defined by serial ID only Connector SC Encoding 8B10B/ 非8B10B均为错用光模块 Length(9um)(Km) 20.0 Length(50um) - Length(62.5um) - Length(Copper) - Cc_base 0x97 CC_EXT 0x94 BR,max Unspecified BR,min Unspecified SFF-8472 Compliance Includes functionality described in Rev 9.4 Diagnostic Monitoring Type Digital diagnostic monitoring Externally Calibrated Power measurement type: Average Power Options TX_DISABLE,and disables the serial output TX_FAULT LOS(signal as defined in SFP MSA) Enhanced Options Alarm/warning flags TX_DISABLE control and monitoring TX_FAULT monitoring Vendor Rev 10 Vender PN SPS43GBP2CDFCHW /光模块型号 Vender SN 9AM2008867 /序列号 Manufactured 09-09-28 Vender name SOURCEPHOTONICS /厂家标识 Vendor OUI Unspecified Vendor specific 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Module type EPON Module sub-type PX20+ Used type OLT Encapsulation Type SFP -1.2 进入单板透明通道查询单板OAM消息当出现ONT 不上线时,请进入单板透明通道查询OLT单板是否有收到上行报文。MA5600T(config)#diagnoseMA5600T(diagnose)%su Challenge:YILK9EHU Please input password:MA5600T(su)%transparent on / -进入单板透明通道模式Serial redirect function is enabled now!MA5600T(su)%user chipid0pon2/pon3 = chipid1pon4/pon5 = chipid2pon6/pon7 = chipid3MA5600T(su)% emac message get statistic mac -查询mac芯片pon口统计Epon MAC statisticRxullRxByte 0x00000000-0x001bd500ullRxFrm 0x00000000-0x00001422ullRxUCFrm 0x00000000-0x00000072ullRxMCFrm 0x00000000-0x000013aaullRxBCFrm 0x00000000-0x00000006ullRxUndersizeFrm 0x00000000-0x00000000ullRxOversizeFrm 0x00000000-0x00000000ullRxCrcErrFrm 0x00000000-0x00000000ullRxMpcpFrm 0x00000000-0x0000002aullRxMpcpByte 0x00000000-0x00000a80ullRxReportFrm 0x00000000-0x0c859304ullRxReportAbortFrm 0x00000000-0x00000000ullRxOamFrm 0x00000000-0x000326f6ullRxOamByte 0x00000000-0x00d66149ullRxLlidErrFrm 0x00000000-0x00000000ullRxDropUngrantFrm 0x00000000-0x00000000ullRxRegisterReq 0x00000000-0x0000001a -OLT接收到的ONT的RegisterReq消息统计。此消息是ONT注册的第一个消息,如果此统计没有增长,说明OLT未收到ONT的注册请求 1.3 现场携带光功率计测试发送光功率(测试前请先清洁光口)建议使用EXPO 350B型号PON专用突发光功率计(测试光功率前需要使用专用擦纤纸或清洁棒清洁PON光口,功率计光口,以及光跳纤)。现场光功率计测试OLT发送光功率,注意选择波长为1490nm,功率单位为dbm,注意光纤的APC/PC头不能对接问题。对于EPON PX20+光模块要求仪器上测试结果为2.57dbm。光功率计需要定期校准(正常模块光功率计测试结果和通过命令行或者网管查询信息相差不大)1.4 交叉验证光模块1. 把确定没问题的模块插上故障PON口,查看是否有问题。2. 把疑似问题模块插到其他端口或正常端口,查看是否有问题。2 GPON光模块简易判断2.1 通过命令行查询光模块信息MA5600T(config-if-gpon-0/12)#display port state 5 - F/S/P 0/12/5 Optical Module status Online Port state Offline Last down cause - Last up time - Last down time - Laser state Normal /有问题的光模块可能显示Failed Available bandwidth(Kbps) 1241216 Temperature(C) 43 /070度OK,且与其他端口的数值接近 TX Bias current(mA) 14 /070mA ok,可与附近同类型的光模块进行对比 Supply Voltage(V) 3.26 /在3.03.6V间ok TX power(dBm) -22.86 /(CLASS B+ 1.55dbm ok)光功率监控异常或者光模块发光异常 Illegal rogue ONT Inexistent Max rate(Kbps) 2500000 Max Distance(Km) 20 Wave Length(nm) 1490 Fiber type Single Mode Signal detect Failed TX fault Normal Identifier SFP Ext.Identifier GBIC/SFP function is defined by serial ID only Connector SC Encoding NRZ /必须为NRZ,否则光模块出现异常(如果为8B10B,则有可能将EPON模块误插) Length(9um)(Km) 20.0 Length(50um) - Length(62.5um) - Length(Copper) - Cc_base 0xfb CC_EXT 0x9c BR,max Unspecified BR,min Unspecified SFF-8472 Compliance Includes functionality described in Rev 9.4 Diagnostic Monitoring Type Digital diagnostic monitoring Externally Calibrated Power measurement type: Average Power Options TX_DISABLE,and disables the serial output TX_FAULT LOS(signal inverted from standard definition) Enhanced Options Alarm/warning flags TX_DISABLE control and monitoring TX_FAULT monitoring Vendor Rev Unspecified Vender PN SPS4348HCPCDFHW /序列号 Vender SN A2K2001542 /序列号 Manufactured 10-01-26 Vender name SOURCEPHOTONICS /厂家标识 Vendor OUI 0006b5 Vendor specific 53 50 53 2d 34 33 2d 34 38 48 2d 43 50 2d 43 44 46 2d 48 57 20 20 20 20 20 20 00 00 00 00 0c 83 Module type - Module sub-type - Used type - Encapsulation Type - -2.2 进入单板透明通道查询单板PLOAM消息当出现ONT 不上线时,请进入单板透明通道查询OLT单板是否有收到上行报文(查看是否有Recv Message:)。MA5600T(config)#diagnoseMA5600T(diagnose)%su Challenge:YILK9EHU Please input password:MA5600T(su)%transparent on / -进入单板透明通道模式Serial redirect function is enabled now!MA5600T(su)%user -进入user模式,如果提示此命令无效,忽略 MA5600T(su)% MA5600T(su)%ploam set print on -打开PLOAM消息交互 MA5600T(su)% Send message: PON:0 OnuId:255 MsgId:OVERHEAD_MSG Data: 0x20 0x00 0x00 0xaa 0xab 0x59 0x83 0x20 0x00 0x00 Send message: PON:0 OnuId:255 MsgId:EXT_BURST Data: 0x15 0x12 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Recv Message:-ONT回应给OLT的ploam消息 PON:0 OnuId:255 MsgId:RESP_SN -ONT回应注册请求消息,如果没有收此消息,说明ONT未发起注册 Data: 。 0x48 0x57 0x54 0x43 0x80 -ONT的SN 0xa4 0x75 0x42 0x03 0x54 MA5600T(su)%ploam set print off -关闭PLOAM消息交互2.3 现场携带光功率计测试发送光功率(测试前请先清洁光口)建议使用EXPO 350B型号PON专用突发光功率计(测试光功率前需要使用专用擦纤纸或清洁棒清洁PON光口,功率计光口,以及光跳纤)。现场光功率计测试OLT发送光功率,注意选择波长为14
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年事业单位工勤技能-湖南-湖南堤灌维护工三级(高级工)历年参考题库典型考点含答案解析
- 2025年事业单位工勤技能-湖北-湖北计算机文字录入处理员五级(初级工)历年参考题库典型考点含答案解析
- 2025年事业单位工勤技能-湖北-湖北水工监测工五级(初级工)历年参考题库典型考点含答案解析
- 2025-2030中国经济适用房产业前景盈利预测与投资专项可行性报告
- 2025年事业单位工勤技能-湖北-湖北医技工四级(中级工)历年参考题库典型考点含答案解析
- 城市更新2025:老旧小区改造中建筑节能技术与可再生能源应用报告
- 2025年事业单位工勤技能-河南-河南计算机操作员三级(高级工)历年参考题库含答案解析
- 2025年事业单位工勤技能-河南-河南机械热加工二级(技师)历年参考题库典型考点含答案解析
- 2025年事业单位工勤技能-河北-河北农业技术员一级(高级技师)历年参考题库含答案解析(5套)
- 2025年事业单位工勤技能-江西-江西垃圾清扫与处理工一级(高级技师)历年参考题库含答案解析(5套)
- 医院信息科笔试题库及答案
- 专题特训五等腰三角形的“三线合一”
- 2025年高考真题-化学(湖南卷) 含答案
- 电厂消防培训教学课件
- 消防安全突发事件应急预案和处理流程
- 压力容器安全员岗位职责
- 2025年安全生产法律法规培训
- 2025年现代通信技术基础与应用考试卷及答案
- 2025年互联网数据中心数据中心安全风险评估报告
- 工业互联网与石化化工行业融合应用参考指南(2025年)
- 矿石运输居间合同范本
评论
0/150
提交评论