IROS2019国际学术会议论文集 2482_第1页
IROS2019国际学术会议论文集 2482_第2页
IROS2019国际学术会议论文集 2482_第3页
IROS2019国际学术会议论文集 2482_第4页
IROS2019国际学术会议论文集 2482_第5页
已阅读5页,还剩3页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Abstract Constraint induced movement therapy CIMT is an effective recovery protocol for patients with stroke However not all the stroke patients can participate in CIMT Devices that assist the movement of the affected side could help increase the number of stroke patients who can participate in CIMT like protocol In this paper a soft cable driven wrist wearable robot called Exo Wrist which assists the wrist of a paretic arm in performing the dart throwing motion DTM with an active forearm anchor is proposed To increase the force transmission efficiency while preventing medical issues due to long term pressure a corset active anchor which compresses the body only when anchoring is needed is developed A moving pulley mechanism and a three layered structure increase the functionality of the anchor Considering the natural movement of wrist extension and the frequently used wrist motions in daily life the wrist is assisted along the DTM direction and the method to find a personal DTM is introduced A 3D printed custom wrist armlet is developed to hold the tendon path and exert a torque along the DTM direction Together with a hand assistive device Exo Wrist could be used as a tool to help stroke patients with difficulty in wrist extension to participate in task oriented rehabilitation protocols such as CIMT Keywords Rehabilitation robotics Soft robotics Robot motion I INTRODUCTION EOPLE with hemiplegia after stroke lose in whole or in part the functionality of the affected side Hence the major goal of stroke recovery protocol is to recover the function of the affected limb 1 Patients with hemiparesis undergo various rehabilitation interventions and among them constraint induced movement therapy CIMT is regarded as one of the most effective rehabilitation protocols for patients with hemiparesis 2 The major goal of CIMT is constraining the non affected side of the upper limb and forcing the use of affected side to perform task oriented activities with intensive practice 3 Nevertheless a majority of patient with stroke are not eligible for CIMT due to harsh requirements of CIMT protocols only 6 5 of patients with stroke are eligible for CIMT 4 Among them a few impaired patients around 10 in 5 cannot benefit from CIMT because they have very little residual upper limb motion on their affected side especially relevant to the voluntary extension and flexion of the hand due to their flexion synergy of wrist and fingers 2 Therefore in order to increase the number of patients with hemiparesis to benefit from CIMT therapy especially patients who cannot participate in CIMT due to their flexion synergy one alternative solution is to develop devices which can help hand and wrist movements while the patients intend to move This paper is supported by the National Research Foundation of Korea Grant funded by the Korean Government MSIT under Grant NRF 2016R1A5A1938472 This would allow them to participate in therapy which follows CIMT protocols but with robotic assistance For designing such robots we selected several factors which should be considered when designing a wrist assistive device to help patients participate in CIMT with robotic assistance protocols based on traditional requirements in CIMT 2 4 First developers should consider the minimum requirements of hand and wrist movements 20 extension of the 1 2 fingers and wrist from the original protocol 3 Second since task oriented motor tasks are also conducted during CIMT robots should assist necessary movements in activities of daily living ADLs especially tenodesis grasp passive finger flexion in response to wrist extension for finger movement or dart throwing motion DTM for the wrist 6 8 Thirdly considering that the CIMT is conducted not only in a clinical setting but also in the patient s home environment the robots are preferred to be portable compact and lightweight Fourthly as CIMT is a rehabilitation method that uses the entire upper extremity it would not be adequate to severely hinder the movements of other upper limb joints Lastly pressure on the skin and muscle tissues over long durations should be avoided considering the long duration of the therapy Previous studies have suggested various hand wearable robots that can fulfill these requirements including tenodesis assistance robots 9 13 Robots for wrist rehabilitations or assistance also have been developed so far Several robots have been made rigid for high transmission efficiency and controllability 14 15 To better adapt to humans and their ADLs some researchers have developed mobile soft wearable robots 16 18 However few wrist robots are considering all the above mentioned factors and some of them are not immediately compatible with other wearable robots due to their size or rigidity For making the robot mobile the robot needs anchors that affix it to the human body and help transfer an assisting force to the wrist by resisting the reaction force of the actuator especially for soft wearable robots In soft wearable robots the reaction force usually occurs along the shear direction parallel to the bone Most of the soft robots realize anchoring with geometric locking using the surrounding bone shape or with frictional force by tightly tying the structures 9 10 19 In wrist robots it is desirable to use anchoring on the forearm to prevent wire tension from affecting other joints Geometric locking cannot be used in it because the geometric shape of the forearm cannot resist the shear force exerted by the actuator Therefore most of the soft wrist wearable robots simply tighten the robots to the body to secure their positions Researchers are with Biorobotics Laboratory Department of Mechanical Engineering Seoul National University Seoul 08826 Republic of Korea corresponding author to provide e mail kjcho snu ac kr Hyungmin Choi Brian Byunghyun Kang Bong Keun Jung and Kyu Jin Cho Member IEEE Exo Wrist A Soft Tendon Driven Wrist Wearable Robot with Active Anchor for Dart Throwing Motion in Hemiplegic Patients P IEEE Robotics and Automation Letters RAL paper presented at the 2019 IEEE RSJ International Conference on Intelligent Robots and Systems IROS Macau China November 4 8 2019 Copyright 2019 IEEE However considering that CIMT lasts for a long period of time 90 of waking hours 2 this anchoring method could cause medical issues from long term pressure if an anchor strongly tightens the body and remains that way for a long time Hence it is necessary to develop a new type of anchor that can mitigate the pressure issues while fixing the robot to the body In this paper we introduce Exo Wrist a novel soft tendon driven wrist assist robot Exo Wrist supports the wrist in the dart throwing motion DTM direction and has an active anchor Fig 1 a Exo Wrist is portable compact and lightweight enough to be used in daily life and supports wrist movements adequately fit to ADLs with a simple command Moreover it can support hand ability by tenodesis grasp Additionally it can directly coordinate with other wearable robots especially hand assist gloves because of its compactness and softness Therefore Exo Wrist can support patients with wrist impairment as well as the ones with other upper extremity impairments The main contributions of the paper are as follows 1 Corset active anchor based soft tendon driven wearable robots For efficient force transmission a forearm anchor should be able to resist the pushing force from the actuator but the part should not tighten the body for a long time to prevent medical issues due to long term pressure exertion Therefore we propose the active forearm anchor which compresses the forearm only when a resistance force is needed To generate high compression with a small actuator a corset based moving pulley mechanism actuated by a tendon is used 2 DTM direction wrist assistance The robot is designed to assist the wrist in the DTM direction which is the natural wrist extension and principal wrist movement during ADLs 7 8 Because the DTM is slightly different from person to person we propose a noninvasive and ergonomic method to find the DTM of each person Moreover in soft wearable robots it is hard to hold tendon paths in the desired way due to the compliance and deformability of soft structures Therefore we developed a 3D printed custom wrist armlet which can maintain the tendon II DESIGN A Hand glove Figure 1 a gives an overview of the Exo Wrist Hand glove is the part that attaches the tendon to the human body to transmit tension to the target joints At the glove a wire enters the dorsal side of the hand from the wrist winds around the hand below the MCP and goes out to the wrist ring near the inserted point The path is similar to the Exo Glove Poly II 9 which designs the path to exert the tension in the direction normal to the surface for stability The main body of the glove is a fingerless golf glove with a wire path formed by embedded Teflon tubes in silicone The wire in and out location is designed to make the tendon path collinear with the path on the moment arm support structure on the wrist ring B Wrist ring Wrist ring is composed of two parts oval shape rigid armlet and flexible moment arm supporting structure The ring determines the position of the actuation wire on the wrist so it is important for the ring to put the wire on the DTM plane of each person Because the DTM plane varies from person to person the armlet of the wrist ring was customized based on three personal parameters wrist width w wrist height h and tilted angle of the DTM plane d Fig 1 b d determines the location of the wire path and w and h determine the shape of the armlet By this customization process the wire near the carpal joint can be located on the personalized DTM plane and the torque generated by the wire tension would make the wrist move in the DTM Moreover the customized size will not allow the ring to rotate which means that the wire will be held in the desired position The rigid armlet is produced by a 3D printer Connex 30 Stratasys USA and silicone pads are attached to its inner part for comfort wearing d is calculated from wrist kinematics which will be introduced in Section 3 The moment arm supporting structure is designed as a series of trapezoids made of flexible silicone rubber attached to the rigid connection part Fig 1 c Because the moment arm of the suspended tendon driven system is the vertical distance between the joint and the wire this structure can Fig 1 a Illustration of the robot b Front view of a wrist ring The shape of the armlet is oval with a flat top line which is customized to each participant s distal forearm shape Moment arm supporting structure where tendon passes through is designed to locate its middle to be above the line tilted by in a vertical line c Right side view of moment arm supporting structure Due to its flexibility it can adapt its shape to the movement of the wrist d Front view of the forearm active anchor It consists of three layers with a sheath and an actuating wire inserted in it e Forearm anchor shape before left and after right actuation f Conceptual figure of collaborative work of Exo Wrist with Exo Glove Poly 9 increase the efficiency of torque transmission to the wrist by increasing the moment arm of the wire The structure is integrated with the armlet using bolts at the location of the wire path of the armlet d Since the supporting structure is located on the wrist it should be able to change its shape with wrist movement Flexibility of the material and shape of the structure help the structure to adapt to the shape of the wrist Moreover a low friction Teflon sheet at the bottom of the structure makes it slide back and forth C Forearm active anchor The forearm active anchor compresses the forearm to generate a large frictional force when the robot assists the wrist movement and releases when the robot does not exert any assisting force An active forearm anchor is a truncated cone shape structure consisting of three layers Fig 1 d e The bottom layer is in contact with the skin and is made of silicone which is safe in physical contact with skin and has a high friction coefficient The high friction coefficient and large contact area with the skin make it possible to generate sufficient frictional force against the pushing force of the actuator with less pressure Spring sheaths from the actuator are inserted into this layer Embedded Teflon tubes form wire paths collinear with those sheaths The top layer is an active layer that compresses and releases the anchor by sliding above the middle layer Pulleys on both ends of the top layer are connected to the anchoring wire Dyneema which is pulled and released by a small motor at the anchor Similar to the corset the anchoring wire is routed using a moving pulley mechanism This mechanism increases the tightening force between the ends of the top layer by several times compared to the wire tension at the end of the wire In other words a small motor that can generate up to a fraction of the required tightening force is enough to generate the required compression force A PET sheet is used as the base of the top layer because though compliant it is stronger along the tensile direction and has a small friction coefficient Between the bottom and top layers a Teflon sheet a compliant sheet with a very low friction coefficient covers the bottom layer Due to its low friction coefficient the top layer can slide freely with respect to the bottom layer which increases the efficiency of the anchor The reason for using multiple layers instead of a single layer in the anchor is to avoid direct contact between the anchoring wire and the skin to prevent abrasion between them and to increase the anchoring ability by satisfying the conflicting friction conditions high friction is needed between the anchor and the skin but low friction is needed when sliding When the robot starts to assist wrist movements anchoring is needed Thus an active anchor compresses the forearm before the force transmission wire is actuated by the pulling anchoring wire using a small motor Once the wrist movement is assisted and the tension on the force transmission wire becomes zero anchoring is no longer required Hence the anchoring wire is released from the anchoring motor relieving the compression Then the subjects can feel comfortable and avoid problems due to long term pressure D Other parts The force transmission wire is pulled by a small pulley combined with a rotary motor IG 32GM 03Type D thus 3 mm was selected as the maximum allowable anchor displacement For all three participants the maximum anchor displacements were within the allowable range for an anchoring wire tension of 11 N and above Furthermore at 11 N the average pressure applied by the anchor is endurable for short durations 27 Therefore a tension of 11 N was selected as the actuation level of the anchor which corresponds to 45 of the power of the selected actuator The purpose of the feasibility test of the active anchor is to validate the role of the active anchor during the operation of the Exo Wrist After they wore the customized robots the subjects were instructed to sit on chairs put their forearms on the jig Fig 4 b with their elbows straight and their forearms pronated and firmly hold a 3D printed pulling rod UPrint SE PLUS Stratasys USA The pulling rod was connected with a loadcell 333FDX KTOYO Korea to measure the wrist torque This torque was measured by multiplying the force measured by the loadcell and the length between the rod and the wrist joint center When the test began each participant was instructed to exert the maximum possible wrist extension force In each trial they reached their maximum in 5 seconds and a break of 30 seconds between the trials was given to the participants The robot assisted the wrist extension in a total of 12 trials support trials ST but did not provide any support to the participants in the other six trials non support trials NST Among the STs forearm anchor was activated in six trials activated anchor support trials AAST but not in the other six trials deactivated anchor support trials DAST Robots supported the wrist movement only when commanded by the participant to support the extension The intention command of the participant was detected by an EMG sensor When the robot was commanded not to support the wire tension was maintained at 0 N The anchor compressed the forearm during the activated anchor support trials and released the forearm during the rest The order of the trials was randomized Table I lists the results of the test Values in the activated row of each participant indicates the difference between the average of the maximum wrist extension torque during NSTs and the average of the maximum wrist extension torque during AASTs and deviations Values in the deactivated row are similar but the difference is that it is calculated between the NSTs and the DASTs As can be seen when activated a robot can assist more than 0 5 Nm When the anchor is not activated the robot cannot generate an average assistance torque of more than 0 2 Nm By using the Wilcoxon rank sum test statistically significant differences between the measured wrist extension torques of the NSTs and AASTs and of the AASTs and DASTs were found for all the participants p0 1 C Motion tracking The purpose of the second experiment is to validate whether the robot supports wrist movement in the target DTM direction After wearing the robot and attaching the reflective markers Fig 3 the participants sat on chairs with their Fig 4 a Experiment setup for the actuation level selection test that constrains forearm movements b Jig for the feasibility test of active anchor and the posture kept going by participants during experiments Fig 5 Results of the selection test a Maximum anchor displacement of three participants at various anchoring wire tensions are expressed in full lines and the average pressure applied by the anchor is plotted using a brok

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论