分析故障点的故障分量电流电压相量图的关系王继弘1 ,李仲明2 (1.华电湖南石门发电有限公司,湖南 石门 415300 2.宁夏电力公司,宁夏 银川 750001)摘要: 由于故障分量原理在微机保护中大量应用,而故障分量存在于故障分量网络中,因此有必要建立短路故障时故障分量网络,画出在故障点电流、电压故障分量相量图。按对称分量概念,求其故障点各序电流、电压,以便理解故障分量原理的微机保护。关键词:故障分量;电流;电压;相量图Analysising the Relationship of fault points fault component current and voltage vector diagramWANG Ji-hong,LI Zhong-ming(1. Central China Electric Power Hunan Shimen Electric Generation Limited Company, Shimen 415300,China;2.Ningxia Electric Power Corporation, Yinchuan750001,China)Abstract: Because of fault component Principle applies in microcomputer protection massively, but fault component exists in fault component network, so it is necessary to build the fault component network of short fault, draw the fault points current and voltage vector diagram. According to the symmetrical component conception, asking the fault points sequence current and voltage, so that understanding the microcomputer protection of fault component principle.Key words: fault component; current; voltage; vector diagram40 引言应用对称分量法分析不对称短路故障时,一种是将不对称短路形成的不对称电流、电压分解为正序、负序、零序三组对称的系统;另一种是当电力系统某点发生不对称短路故障时,看成是在原有三相对称系统上,原有的电源电动势M=0, N=0,在故障K点反向接入正常运行电压,可以分解为正序、负序、零序分量。称为故障分量亦称为突变量。在短路故障分析中,要选出特殊(基准)相指的是故障处与两相情况不同的那一相;同一类型短路故障发生在不同相别上时,特殊相的序分量边界条件不变,于是短路特性不变;故障点的正序网络、负序网络、零序网络与故障类型、故障相别无关;但各序网络合成的复合序网与短路故障类型、相别有关,复合序网指的是特殊相的。故障点故障相电流绝对值I与故障支路的正序分量电流I成正比。高压电网中发生短路故障时有Z1=Z2时,两相短路电流等于同一点三相短路电流的2,当Z1=Z2=Z0时,I=I=I;当Z0Z1时,有II,II;当Z0=Z1时,有I=I,I=I;当Z0Z1时,有II,II;在故障点或母线上的正序电压有如下的关系:UUUU;越靠近电源,正序电压数值越高。对于负序电压和零序电压(或故障分量电压)的分布,故障点最高,离故障点愈远、数值愈低。1 三相短路K(3)故障分量分析K点三相短路,在故障分量网络中K点仅有反向接入正常运行电压、造成,原有电源电动势M=0,N=0;因三相对称,只需画出A相即可,如图1所示。K点三相短路故障时的故障分量的边界条件为:=-;=-;=-K点序电压的故障分量的边界条件为:=-a(-)a2(-)=-=-a2(-)a(-)=0=-(-)(-)=0=-/Z1=/Z1 =0; =0K点三相短路故障时故障分量电压、电流相量图如图2所示,其正序电压分布图如图3所示。2 两相接地短路K(1.1) 故障分量分析K点BC相接地短路时,在K点反向接入正常运行电压、 造成,原有电源电动势M=0, N=0的情况下,即在故障分量电压-、-作用下,在其K点BC相接地短路时故障分量网络如图4所示,在K点BC相接地短路故障分量的边界条件为:=0; =-;=-ZM1M MA ZMK1 K ZNK1 NA NMAZN1NA-+图1 K点三相短路故障时的故障分量网络Fig1 Fault component network of k points three-phase short circuit faultkA0在故障分量网络中建立相应的故障分量正序、负序、零序电压、电流;用特殊相A相序分量表示,可得序电压、电流边界条件方程式如下 :=0-= -=-=图2 K点三相短路故障时的故障分量电压、电流 相量图Fig2 Fault component current and volage vector diagram of k points three-phase short circuit faultKOUMAUNAMKN-U(a)故障分量电压分布 (a)Voltage set of fault componentUMAUNA(b)总的正序电压分布(b)All set of positive sequence voltage图3 K点三相短路故障时的正序电压分布Fig3 Positive sequence voltage set of k points three-phase short circuit faultZM1 M ZMK1 K ZNK1 N ZN1ZN1ZM1ZM1ZMK1 ZNK1MCZMK1ZNK1NCZN1NBMBgNCMBNBMC图4 BC相接地时的故障分量网络Fig4 Fault component network of BC two-phase grounding fault=a2a=-(a2Z1aZ2Z0)=- =aa2=-(aZ1a2Z2Z0)=-将上三方程联合求解,得到=/Z1Z2 Z0/(Z2Z0)=-Z0/(Z2Z0)=-Z2/(Z2Z0)又=-Z1=-Z1/Z1Z2 Z0/(Z2Z0)当Z1=Z2时,=-(Z1Z0)/(Z22Z0)=-Z2=-Z1-Z0/(Z2Z0)当Z1=Z2时,=-Z0/(Z1Z0)=Z0/(Z12Z0)=-Z0=-Z0-Z2/(Z2Z0)当Z1=Z2时, =-Z0/(Z1Z0)=Z0/(Z12Z0)可见: 与大小相等, 相位相同,与反相位。=(Z0-Z1)/(Z12Z0)0(Z0Z1时)将、代入、中,可得:=-、=-表示分析无误。根据上述计算分析,可作出故障分量复合序网如图5所示,有关故障点故障分量电压、电流相量如图6所示,显而易见,故障分量的负序网络、零序网络与原有的负序网络、零序网络相同,两相短路K(2)、单相接地短路K(1)故障分量分析,方法类同,在此不赘。Z1Z2K1N1K2N2无源网络Z0K0N0图5 BC相接地时的故障分量复合序网Fig5 Fault component compound sequence network of BC two-phase grounding fault(a) 电压故障分量相量图(a) Voltage fault component vector diagram (Z0Z1时)3(b)电流故障分量相量图(b) Current fault component vector diagram图6 BC相接地短路时故障分量相量图Fig6 Fault component vector diagram of BC two-phase grounding fault图中示出的是Z0Z1情况120;当Z0=Z1时,(a)图中=0;(b)图中120;当Z0Z1时,(a)图中反向;(b)图中120。3 结论3.1求故障分量的步骤:3.1.1列出故障分量的边界条件。3.1.2根据边界条件求出特殊相序分量特点,作出故障分量复合序网。3.1.3根据复合序网可求出电网中各支路、各节点电流、电压故障分量,并可求出规律性特点(继电保护中用)。3.1.4根据复合序网,可方便求得故障分量电流、电压相量图之间的关系。3.1.5由故障分量边界条件的全电压、全电流与其边界条件的序电压、序电流应用解析式与相量图关系互为验证其分析的准确性。3.2对在K点发生K(3)、K(2)、K(1)、K(1.1)短路故障时故障分量电流、电压有如下结论:3.2.1故障点的短路电流就是故障分量电流。3.2.2故障点的负序、零序分量电流、电压就是故障分量负序、零序电流、电压。3.2.3故障点的正序分量电流、电压与故障分量正序电流、电压不同。3.2.4在分析故障分量时,正序、负序、零序网络均是无源网络,故有如下关系式:=-Z1; KA1=-kA1Z1 =-Z2=KA2=-kA2Z2 =-Z0=KA0=-kA0Z0kA1=; kA2=; kA0=为分析方便,角标右上角带“”表示故障分量。参考文献1 王梅义.高压电网继电保护运行.北京电力工业出版社,1981年.王梅义.电网继电保护应用.北京电力出版社,1999年.WANG Mei-yi. Relay Protection Running of High Electric Power System.Beijing Electric Power Industry Press,1981.WANG Mei-yi.Application of Electric Power System Relay Protection.Beijing Electric Power Press,1999.2 朱声石.高压电网继电保护原理与技术第三版.电力出版社,2005年.ZHU Sheng-shi. The Third Edition of High Electric Power System Relay Protection Principle and Technology. Electric Power Press,2005.3 江苏省电力公司编电力系统继电保护原理与实用技术.电力出版社,2006年.Electric Power System Relay Protection Principle and Practical Technology written by Jiangsu Electric Power C

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论