TENDER DOCUMENT FORDESIGN, MANUFACURE, TESTING AND SUPPLY OF 132/33/11 KV, 50 MVA TRANSFORMERFOR132/33 KV SUBSTATION ATGHORASAL THERMAL POWER STATIONGENERAL TECHNICAL REQUIREMENTS & SPECIFICATIONGENERAL TECHNICAL REQUIREMENTS6.1 25/50 MVA 132/33/11kV Power Transformer For 132/33kV Sub-station atGhorashal Power Station.a. 132/33/11KV, ONAN rating 25/25/18MVA, ONAF rating 50/50/35MVA, out door mounting, 3 phase. 50 Hz, uniform insulation. 132 4x2 % KV (HV taps on-load operating 9 Nos. of taps), mineral oil immersed equipped with BCT. The supply of transformer will also include suitable size (size will be confirmed during detail Engineering) of MS rail for placing of transformer on foundation. During submission of the bid the technical data requirement of BPDB shall be fully complied by the bidder. In case of any deviation observed in bidders technical data from Users technical data, the bidders bid will be declared non-responsive. The bidder will provide 1(one) engineer for expert service during installation, testing and commissioning of the transformer for 15 days. The following specification are prepared based on the existing one with a view to procure an identical one because both will run in Parallel. Successful Bidder may visit Ghorasal power station for taking necessary data form existing one externally by measurement for detail engineering.b. The insulation value of HV /MV/ LV sides are:(i) Highest system voltage: 145 / 36/ 12kV(ii) Basic insulation Level (BIL): 650 / 170/ 75 kV(iii) Power frequency with standVoltage (1min) : 275/70/28 kV.The Insulation level of HV & MV Neutral Bushing shall be same as Phase Bushings.c. The HV bushing and bushing for the neutral shall be capacitor type, porcelain being brown glazed. The BCT fitted in the neck of each bushing shall have 2 core & 4 tapping of each core. The ratio, accuracy class and burden of BCT are as follows:HV BCT:(i) 1st core:No of tapping: 4 1st tap: 400/1A,3P20, 20VA.2nd tap: 600/1A, 3P30,30VA.3rd tap: 750/1A, 3P30, 75VA.4th tap: 1000/1A, 1P30, 30VA.(ii) 2nd core:No of tapping: 41st tap: 400/1A, class 0.2, 20VA.2nd tap: 600/1A, class 0.2, 30VA.3rd tap: 750/1A, class 0.2, 75VA.4th tap: 1000/1A, class 0.2, 30VA.Bushing for the neutral of HV side:(1)1st core:No of tapping: 4 1st tap: 200/5A, 10P15, 15VA.2nd tap: 300/5A, 3P10,10VA.3rd tap: 400/5A, 3P20, 20VA.4th tap: 600/5A, 3P30, 30VA.(ii)2nd core:Same as 1st core:d. The MV bushing and bushing for the neutral may be of capacitor type or porcelain type with outside glazed of brown porcelain. The BCT fitted in the neck of each bushing shall have 2 core & 4 tapping of each core. The ratio, accuracy class and burden of BCT are as follows:MV BCT:(i) 1st core:No of tapping: 4 1st tap: 400/5A, 3P20, 20VA.2nd tap: 600/5A, 3P30,30VA.3rd tap: 750/5A, 3P30, 75VA.4th tap: 1000/5A, 1P30, 30VA.(ii) 2nd core:Same as 1st core.Bushing for the neutral of HV side:(I) 1st core:No of tapping: 4 1st tap: 400/5A, 3P20, 20VA.2nd tap: 600/5A, 3P30, 30VA.3rd tap: 750/5A, 3P30, 75VA.4th tap: 1000/5A, 1P30, 30VA.(ii)2nd core:Same as 1st core:e. The LV bushing may be of capacitor type or porcelain type with outside glazed of brown porcelain. No CT required for the bushing.f. Values of resistance reactance of the transformer shall not be deviated by more than 2% (two percent) of the BPDBS requirements and the core & copper loss of transformer shall not exceed 5% (five percent) of BPDBS requirements. The above-mentioned values are the tolerance values to be maintained during factory testing if exceeds the transformer will be rejected.The impedance voltage, core loss and copper loss of the transformer shall be: Impedance voltage at HV-132-kV, MV 33, kv at 50 MVA and at 750C:Between HV and MV winding = 11.568%Between HV and LV winding = 19.443%Between MV and LV winding = 6.051%Core loss at nominal voltage, normal ratio and at rated frequency = 37.914 kW.Total excitation current = 0.251%Full load copper loss at nominal voltage (HV=132kV, MV=33kV) normal ratio at rated frequency and at 750C:50MVA HV and MV winding = 271.712 KW35MVA HV and LV winding = 170.854 KW35MVA MV and LV winding = 130.092 KWg. The winding shall be capable of withstanding:14.3 times base current for 5 seconds.16.6 times base current for 4 seconds.20.0 times base current for 3 seconds.25.0 times base current for 2 seconds.The winding shall be of electrolytic copper, free from burs and splinter. Paper shall be used for conductor insulation.h. The insulating oil shall meet all requirements as defined by NEMA standard/ B.S. shall be chemically stable, free from acidity and other corrosive ingredients and shall posses high dielectric strength. Oil for first filling shall be shipped in non-returnable drums. 10% of the quantity required for a transformer is to be supplied in addition due to usual losses during installation centrifuging etc.i. The transformer tank shall be of welded construction fabricated from high tensile steel plate and shall be designed to withstand full vacuum.j. The transformer shall have air seal cell type oil conservator tank (the oil surface is completely isolated from the atmosphere by installing an oil resistant rubber cell in the interior of the conservator) at the top. Transformer will be provided with 2 separate conservators (1for main tank and another for On load Tap Changer), which will be having provision for mounting separate MOLG. One part to be connected with transformer main tank through Buchholtz Relay (with cocks on both side) and the other part with OLTC tank through another gas Relay (with cock either side). Both will have oil level indicate (visual) with contacts for medicating “LOW OIL LEVEL” in the control panel.k. Pressure Release Devices for both Main Tank and OLTC Tank shall be providedl. Silica gel Breather with glass window shall be provided for both halves of the conservator lank.m. The On-load Tap Changer operating device shall be equipped with local (manual and electrical) and remote electrical operating device with appropriate interlocking. The OLTC motor shall be 3-phase 400 V operating type. The mechanical position indication shall be there both at the tap changer as well as on the operating device. Contacts Arrangements shall be there for remote position indicator (by digital display system) of the tap. Appropriate glands for the entry of control cable shall be provided.n. Sufficient Cooling Fans (3-phase, 400V, 50 HZ) of adequate capacity shall be fitted on the body of the transformer for cooling purpose to achieve the ONAF rating over the average ambient temperature of 400C. There shall be a control device in weather proof housing fitted on the body of the transformer and equipped with control relay operated by sensing device of oil temperature inside the transformer and operate requisite No. of fans. Beside there shall be manual switching device of cooling fans.o. The Radiators shall be in banks, which can be filled with or removed from the beds of transformer tank. Sufficient radiators shall be provided to achieve the ONAN rating at average ambient temperature of 400C. Each bank of radiator must have two stop valve one of which should be fixed at the top and the other at the bottom.p. Beside the main components of the transformer the other features and accessories to be associated which are as follows: (i) Inspection hole with cover.(ii) Manhole.(iii) Nameplate with complete diagrams and main speculations.(iv) Upper and lower oil valves oil sampling valve and drain valve.(v) Ladder to climb up to top with barrier at the bottom.(vi) Thermometer for sending oil and winding temperature and display: WTI shall have two contacts among them one will be used for alarm circuit and other will be suitable for intercropping of HV and MV/LV Circuit Breaker.(vii) All HV (132 KV) terminals shall be provided with appropriate connecting clamps to be connected with 636 MCM ACSR conductors. The LV (33 KV) terminals shall have also connecting clamps appropriate for being connected with one 636 MCM ACSR conductor. The neutral terminal shall have connecting clamps to be connected with 2/0 HDBS wire. The size of conductors may be changed during approval stage. (viii) There shall be four wheels (flange type) suitable for mounting on rails and to carry the transformer as a whole.(ix) The transformer shall have at least two grounding terminals on its body.All ferrous parts of the transformer shall be galvanized or painted with appropriate paints of MUNSELL NO-5 Y7/1. Transformer with maximum shipping height (not exceeding 11 feet) will be preferred.q. One set of extra gaskets and one set bushing of each type is to be supplied with the transformer lot without extra cost.r. The loss capitalization of power transformer will be done by the following formula for evaluation.C = A + 25650 X FL.Where:C = Capitalized cost in Taka.A = Quoted C&F cost in Take.FL = Total consumption of cooling fans in KW.s. Make and Model of Tap Changer: The transformer will be fitted with MR, Germany make On Load Tap Changer (M111 500 Y Model)t. Color of Finish Paint: All the existing transformers at Ghorashal are having external Aluminum finish Paint, The same will be provided for the new transformer.u. Termination of tertiary: Tertiary (11KV) winding will be brought out side to tank top after closing delta winding inside through 3 external bushings. (Bushings will be supplied extra)v. Control scheme of Tap Changer: On Load Tap Changer control scheme of new transformer will be suitable for individual operation of transformer from Control room. Master Follower, Individual operation facility will be provided in this unit.w. Terminal connector: Transformer will be supplied with terminal connectors suitable for connecting to 636 MCM ACSR conductors.x. Rails: The transformer will be supplied with 2 sets of rails (1 set having 2 pieces of length equal to length and breadth of the transformer).y. Shipping: Main Body in Nitrogen filled condition with pressure monitor and extra Nitrogen Cylinder.TECHNICAL PRTICULARS AND GUARANTEE SCHEDULEOF132/33/11KV POWER TRANSFORMER(To be filled up by the Bidder otherwise bid will be rejected)Sl.DescriptionUnitBPDBsBiddersNo.RequirementsData01. Name of Manufacturer02. TypeOut door03. Rated Power (ONAN/ONAF)- High Voltage (HV)MVA25/50- Medium Voltage (MV)MVA25/50- Low Voltage (LV)MVA18/3504. Cooling systemONAN/ONAF05. Phase3- phase06. Rated Voltage of Transformer- High Voltage windingkV132- Medium Voltage winding kV33- Low Voltage windingkV1107. Rated FrequencyHz5008. Maximum Temperature rise(Allowable over an ambientTemperature of 400C)- in Oil0C55- in winding0C6509. Total Excitation Current%0.25110. Core-loss at rated frequencyand rated voltage at nominal tapkW37.91411. Full load copper loss at nominalvoltage (HV-132kV, MV-33kv), atrated frequency and at 750C- 50 MVA HV and MV winding kW271.712-35 MVA HV and LV windingkW170.854-35 MVA MV and LV WindingkW130.09212. Cooling fan losses during runningAt full ONAF capacitykW13. Impedance Voltage for HV/MV at at750C at 50MVA base (%)Tp 110.911Tp 511.568Tp 912.48114. Impedance Voltage for HV/LV at at750C at 35MVA base (%)Tp 118.500Tp 519.443Tp 920.79615. Impedance Voltage for MV/LV at at750C at 50MVA base (%)6.05116. Highest System Voltage- HV/MV/LVkV145/36/1217. Basic Insulation Level:- HV/MV/LVLightning impulse voltage (1.2/50kV650/170/75 Peaks wave)18. Power Frequency WithstandVoltage (1 min)- HV/MV/LVkV275/70/2819. (a) HV winding resistance Y at 320CTap11U-1NW0.75001V-1NW0.76251W-1NW0.7500Tap51U-1NW0.68751V-1NW0.68751W-1NW0.6875Tap91U-1NW0.62751V-1NW0.62751W-1NW0.6275(b) MV winding resistance 2U-2NW0.036252V-2NW0.036252W-2NW0.03625(c)LV winding resistanceFor existing 13U-3WW0.011003V-3UW0.011253W-3VW0.0112520. On Load Tap Changer on HV side- Manufacturer- TypeM.R Germany- Number of TapsM 111 500Y MODEL-Tap range09- Step voltage%8-Rafted Through currentV2640- Basic Insulation LevelA400kV65021. Bucholz Relay- Manufacturer- Type22. Vector GroupYn/Zn/D-1-1123. BCT particulars:(a) HV side:- No of core in each bushingNos02i. 1st core:No. of TappingNos041st tap400/1A, 3P20, 20VA2nd tap600/1A, 3P30, 30VA3rd tap750/1A, 3P30, 75VA4th tap1000/1A, 1P30, 30VAii. 2nd core:No. of TappingNos041st tap400/1A, class 0.2,20VA2nd tap600/1A, class0.2,30VA3rd tap750/1A, class 0.2,75VA4th tap1000/1A,class0.2,30VA(b) Neutral of HV side:- No of coreNos021st coreNo. of TappingNos041st tap200/5A, 10P15, 15VA2nd tap300/5A, 3P10, 10VA3rd tap400/5A, 3P20, 20VA4th tap600/5A, 3P30, 30VAII. 2nd core:Same as 1st core(c) MV side:No. of core in each busingNos02i) 1st core:No. of TappingNos041st tap400/5A, 3P20, 20VA2nd tap600/5A, 3P30, 30VA3rd tap750/5A, 3P30, 75VA4th tap1000/5A, 1P30, 30VAII. 2nd core:Same as 1st core(d) Neutral of MV side:No. of core in each bushingNos.02i) 1st core:No. of TappinNos.041st tap400/5A, 3P20, 20VA2nd tap600/5A, 3P30,30VA3rd tap750/5A, 3P30, 75VA4th tap1000/5A, 1P30, 30VAII. 2nd core:Same as 1st core(e) LV sideNo CT required24. Weight:with OilKgwithout OilKg25. Dimensions:Length x Width x Heightmm26. Dimension of railAs per Users existingConfirmed during detailEngineering.F
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 广东女子职业技术学院《微生物学(含实验)》2023-2024学年第二学期期末试卷
- 山西电力职业技术学院《汉俄翻译》2023-2024学年第二学期期末试卷
- 北海康养职业学院《财务管理案例分析》2023-2024学年第二学期期末试卷
- 云南水利水电职业学院《数据挖掘基础》2023-2024学年第二学期期末试卷
- 山东财经大学燕山学院《播音主持作品赏析与研究》2023-2024学年第二学期期末试卷
- 杭州电子科技大学信息工程学院《运动疗法技术学》2023-2024学年第二学期期末试卷
- 钟山职业技术学院《Java程序设计基础》2023-2024学年第二学期期末试卷
- 贵州护理职业技术学院《粉末冶金材料原理》2023-2024学年第二学期期末试卷
- 动物世界美术课件
- 2024年工业缝制机械项目投资申请报告代可行性研究报告
- 53模拟试卷初中语文八年级下册第六单元素养综合检测
- 粮油食材配送投标方案(大米食用油食材配送服务投标方案)(技术方案)
- 个人独资企业(合伙企业)转型有限责任公司登记申请书
- 化妆品代理加盟协议
- 滤料采购合同范本
- 发电厂电气部分智慧树知到期末考试答案章节答案2024年东北电力大学
- 车辆顶账协议书范文
- 2024年株洲国创轨道科技有限公司招聘笔试冲刺题(带答案解析)
- 合肥一中2024届高三最后一卷 政治试卷(含答案)+答题卡
- 部编版七年级下册语文各单元生字词总表
- AI+蛋白质行业研究报告 2024
评论
0/150
提交评论