INTELLIGENT INVERTERVF61INSTRUCTION MANUALULYHFRQH P U P S 9 S D W T 6 I 9 8 P I U S P G T 820 Lakeside Drive - Gurnee, IL. 60031 1-(800) DRIVCON (374-8266) PH: (847) 855-9150 FAX: (847) 855-9650Email: 12-17-96 REV.IntroductionThank you for your purchase of Drivecon Corporations VF61 series inverter.Please read through this instruction manual carefully prior to using it and get familiar with properinstallation, wiring and operations to ensure optimum and trouble-free operation.This instruction manual describes the basic and standard operation procedures. See the catalog forthe specifications, capacity, outer dimensions, environmental conditions and so forth.The VF61 series is to be used for a custom designed product or system, use the values written in thedrawings or test report of them, not the values shown in this manual.Precautions for Safe Operation..Supply the specified voltage to the input terminals of the inverter. (If 400V power supplied tothe 200V type inverter, the inverter will be broken.)Provide the input side of the inverter with an MCB of the proper capacity.Be sure to connect the inverter to the ground to prevent accidents.Do not connect the supply line to the output of the inverter. Otherwise, the inverter will bebroken.Do not connect a phase advancing capacitor to the output terminals of the inverter.Otherwise, the inverter will be broken.Before maintenance work or inspection, turn the inverter power off to avoid electric shock.Wait until the CHG LED goes out. Note that the heatsink may be hot in some operatingconditions.Do not change the parts or make reckless alterations.The inverter has no noise suppression device. Please contact us if such a device is necessary.Memory protectionWe recommend that set data be protected against rewriting in order to prevent misuse of the console.(See 2.5)Table of Contents1.Before starting operation1.1Checking supplied components and parts1.2Structure of unit1.3Installation1.4Circuit construction and terminal wiring1.5Peripheral devices and wire sizesHow to use console2.1Display the keys on console2.2Monitor mode2.3Function mode2.4Operation mode2.5How to protect dataAutomatic measuring3.1Inputting motor data3.2Automatic measuring operationsOperation procedures4.1Connecting inverter to motor4.2Inputting basic data4.3Operation from consoleTroubleshooting5.1Error messages and operations5.2Troubleshooting5.3Phase failure of input power sourceInspection and maintenance6.1Periodical inspection6.2Insulation resistance test6.3Precautions for replacing printed circuit board6.4DisposalAppendix7.1Enclosure dimensions7.2Typical wiring diagram7.3Operator unit dimensions7.4Standard specifications7.5VF61 Programming chart7.6D61532 (D61533) Input Signal Isolator Board instructions112356679910101111111213141515161617181920212..1Before starting operationChecking supplied components and parts.When you receive the VF61, check it carefully.(1) Make sure that the specifications of VF61, accessories and spare parts are properly inaccordance with your order. Check the logo mark on the cover to see if the unit type is asyou ordered.200V type: 22400V type: 44Voltage (V)Example: 2R2: 2.2 3R7: 3.7 5R5: 5.5 7R5: 7.5Inverter capacity (kW)Applicable power source INPUT: 380 to 460V, 3-phase, 50/60 Hz OUTPUT: 2.2kW, 5.5A(2) Make sure that the supplied VF61 hasnt been damaged during transportation.(3) Make sure that no screws, bolts, etc. are loose or dislocated.If you find some problems, contact the dealer you purchased the VF61 from.1.2Structure of the unit1.2.1 Appearance of unit and components-1-1.2.2 Opening of front cover If you are going to inspect the VF61 or carry out automatic measuring (described in section 3 below), open the front cover as shown below.(1)(2)(3)Remove the fixing screws from the bottom of the front cover.Draw the front cover to the front.When the front cover is fully opened, push it. The cover is fixed in the Up position.1.3Installation1.3.1 The installation condition has great influences upon the service life and reliability of theinverter. Do not use the inverter in the places shown below. Be sure to run the inverter in theerating conditions shown in the catalog.(1) A moist or dusty place. A place exposed to water or oil drips. If the inverter is used in such a place, the circuit insulation is deteriorated, resulting in shorterservice life of the parts.(2)Extreme heat or cold out of the specified temperature range. If the service temperature is too high, bad influences are caused upon capacitors, and parts ofcooling fan or motor, etc.(3)A place exposed to corrosive gas Corrosive gas deteriorates the reliability of the parts and/or connecting part.(4)A place with much vibrations. Vibrations cause poor contact of the connectors, disconnection of wires, damage to parts, etc.1.3.2(1)Installation directionIf the VF61 is used separately or built into a control panel, follow the instructions below.Installation directionInstall the VF61 vertically with its marking VF61 upward as shown below.op-2-(2)Securing cooling spacesProvide the VF61 with proper cool-ing spaces as shown on the right.The cooling fan takes air from thebottom and exhausts it to the top.Secure enough spaces so that a wireduct, etc. do not hinder properventilation.Install peripheral devices so that heatgenerated by them does not reducethe cooling efficiency of the VF61.1.4Circuit construction and writing terminal1.4.1 Circuit constructionThe following shows the standard circuit construction of the VF61.Safety Precautions1.Supply the specified voltage to the inverter. If 400V power is applied to the 200V type inverter, damage will occur.(Note 1)2.Be sure to provide the inverter with an MCB of the proper capacity. See 1.5 below. (Note 2)3.Be sure to connect the inverter and motor to the ground to prevent accidents. (Note 3)4.Connect a motor to the inverter output terminals. Do not connect the supply line to them. Otherwise, the inverter will be damaged. (Note 4)Options1.Connect a dynamic brake resistor.(Note 5)2.Connect a DC reactor DCL.(Note 6)-3-1.4.2 Terminal blocks(1)Main circuit terminal block R, S and TConnect AC power to these terminals. (Do not supply 400V to the 200V type inverter.) Terminal 1 and 2Connect the wires of the optional DC reactor DCL to these terminals. These terminals are short circuited before shipment. Terminal 2 and BConnect the optional dynamic braking (DB) resistor to these terminals. Terminal 2 and 0Connect the optional DB unit and resistor to these terminals.(2)Control terminal blockSafety PrecautionTerminals 10 and 34 carry 0V of the control circuit. Never connect these terminals to GND.-4-1.5Peripheral devices and wire sizes1.5.1 Selection of I/O devices and precautions for main circuit wiring. The following shows the I/O devices of the VF61 unit and their wire sizes.200V typeVF61-_ _ _ 22Type2R222Applicable motor (HP)Input MCCB(Note 1)Peripheral deviceInput MC (Note 2)Output MCInput side (Note 3)Wire size (mm)Output side (Note4)DCL terminals(1 & 2)315AK20K202.03.52.03R722520AK20K202.05.52.05R5227.530AK35K253.58.03.57R5221040AK50K355.5145.511221560AK65K508.0148.015222060AK65K658.02214222230100AK95K95222238302240125AK125K125383838372250150AK150K150383850452260225AK220K220606080552275300AK300K30080801007522100400AK400K3001501001509022130400AK400K400150150200400V typeVF61-_ _ _ 44Type2R244Applicable motor (HP)Input MCCB(Note 1)Peripheral deviceInput MC (Note 2)Output MCInput side (Note 3)Wire size (mm)Output side(Note 4)DCL terminals(1 & 2)315AK20K202.02.02.03R744510AK20K202.02.02.05R5447.515AK20K202.02.02.07R5441030AK25K202.03.53.511441550AK35K15442050AK50K505.58.08.022443075AK50K508.08.01430444075AK80K80141422374450100AK95K95142238454460100AK100K95223838554475125AK125K1253838607544100200AK180K150608010011044150300AK300K2208015020016044200400AK400K30015015025020044250500AK600K40020015025025044300600AK600K600250250150 (x2)Notes:1.The values of the input MCB show the rated currents. (Determine the breaking capacity from the source capacity, etc.)2.The shown values are those of the electromagnetic contactors MS-K series made by Mitsubishi Electric Corp.3.The wire sizes between the MCB and inverter input terminals are the sizes of the KIV or RD wires.4.The cable length between the inverter and motor should be less than 30 meters. The shown values are those of the CV cables.5.If the input MC is used, the interval between turning on and off should be more than 10 minutes.Safety Precautions1.If the motor has a phase advancing capacitor, be sure to disconnect it. (If the inverter runs with the phase advancing capacitor connected, the inverter may be broken.)2.Be sure to connect a circuit breaker (input MCB) on the inverter input side.3.Be sure to connect the inverter and motor to ground. (Use the exclusive grounding terminal.)-5-2.How to use console2.1Display and Keys on ConsoleThe console has 16 columns x 4 lines LCD and operation keys as shown below.This mark designatesthat the console isselected to the numericentry key mode.LCDMode selector keysSelect the operation, func-tion or monitor mode withthe OPR, FUNC, or MONIkey. (For details of thesemodes, see the followingsection.)(Every press of keyalternates thesefunctions.Numeric entry keys(Upper)Function entry keys(Lower)Data setting keyReset key)Operation selectionkeys and operation keys. Monitor mode Press the MONI key, and the current setting is displayed as shown below.2.2.1 A monitor code (of 16 codes) and operation condition are displayed. (See 2.2.2 for displayed items) Indicates selected operation keys. * MONITOR *REM/STOP/FOR/JOG (00)FOUT 60.0 HzIndicates a monitor code and its content.To change a displayed monitor code, press anumeric key (0-9), function entry key, and upor down arrow keys.Stored data (previous data) is displayed.After operation starts, an operation value isdisplayed.2.2.2 Displayed code list (Items selectable in monitor mode)Display on LCD000102030405FoutFrefIoutVoutTorq outVdcItemsOutput frequencySet frequencyOutput currentOutput voltageTorque (Torque current)DC voltageUnitsHzHzAV%VActual revolution is displayed in ASRoperation. Revolution converted fromfrequency is displayed in otheroperations.OL counter begins to count whencurrent exceeds rated motor current.OL operation starts at 100%. (OLset=100%)Estimated torque is displayed inpercentageRemarked2.206Motor speedMotor (synchronous) revolutionrpm07OL counterOL counter%08Line speedLine speed.-6-Display on LCD09101112131411term check12term check0-term checkItemsInput terminal check 1Input terminal check 2Output terminalUnitsbitbitbitRemarked1 is displayed when terminal block isturned on. For meaning of each bit, setable below.DittoDitto15ROM VersionROM VersionXX-XX of ROM software versionVF61-XX-XX is displayed throughconversion of alphabetic charactersinto numeric characters like A=0, B=1and so forth.1617Special moniTrouble moniFor manufacturers adjustmentReading error records.Contents of latest five errors andcurrent, voltage, etc. of these errors aredisplayed. Function mode Press the FUNC key, and current data is displayed as shown below.2.3.1 The internal data of the setting functions may be checked and changed. (See 2.3.3 below.)Code number of setting function and contentsare displayed.To change a displayed code number of thesetting function, press a numeric key (0-9),function entry key, and up or down arrow key.SP set-1, SP set-2 and option of sixteen basicdata codes 0 to 15 and expanded items of code16 may be selected with the SET, up and downarrow keys.Set data is displayed.2.3.2 Changing set data(1)Before changing dataThe numeric keys may be used.To change the set data, press the SET key.* FUNCTION SET * (00)Ref(Set).F 45.0Hz *.0 HzThe lowest line is displayed when the SETkey is pressed.Display when numeric entry is selected.Press the SET key, the numeric entry key isautomatically established. Change data withthe numeric entry key.Flicker-7-2.3* FUNCTION SET * (00)Ref(Set).F 45.0Hz(2)After changing dataChange data, then press the SET key.* FUNCTION SET * (00)Ref (Set).F 60.0 HzThe lowest display disappears, and new dataappears.2.3.3 Set data code list (Items selectable in function mode) CodeNumbe0001020304Display on LCDDescriptionsSet ranges(Selection items)-Top.F Top.F0.030.00.030.0-Top.F Top.F-Top.F Top.F Fmax 400.0(Note 1) 30.0Top.F280-500140-250 0.13600.0 0.13600.00.0-20.00.0-10.080-110Linear Sqr-Law BendMin.F startFree startDecel stopFree stopSp.set-1Sp.set-2Option Standardfactory set data0.05.05.00.00.0 Settingresolution0.10.1UnitsRewriting inoperationOOOOOFmax means the maximum ofRef(Set).F, PC-Base.F and other setvalues whose upper limit is Top.FRemarksRef(Set).FFOR-JOG.FREV-JOG.FPreset1.FPreset2.FSet frequencyForward joggingfrequencyReverse joggingfrequencyPreset frequency 1Preset frequency 2HzHzHzHzHz05Top.FMax. frequencyPower control(base) frequencyRated outputvoltageAcceleration time(1)Deceleration time(2)Torque boostvolumeMin.frequencySetting overloadratioV/F patternselectionStart modeselectionStop modeselectionExpanded set itemselection60.00.1HzX06070809101112PC-Base.FRated Out.VAccl.TimeDecl.TimeTorq.BoostMin FOL.Set60.040020030.030.00.00.51000.10.11HzVVsecsec%Hz%XOOXXOOOLinear: V/F linearSqr-Law: V/F square reductionBend: V/F folded lineMin.F start: Starting at minimumfrequencyFree start: Free startingDecel stop: Stopping afterdecelerationFree stop: Free stoppingFor selecting items 17 and after.See the application manual.Depends on the 400V and 200V classes13V/F PatternLinearX14Start.ModeMin.FstartDecelstopX15Stop.ModeX16Function.upSp.set-1ONote 1:When changing the set data of code number 05 Top.F (maximum frequency), alsochange the over-frequency in the following procedures:Select code number 16 Expanded set item selection to select.Sp.set-1. Display code number 21 OF.Set. Change data to a value higher than thesetting of code05 Top.F with the SET and numeric key entry.2.3.4 Data recording(1)When data of each function has been set, it should be protected as shown in 2.5 below.(2)We recommend that function data be stored separately, before maintenance work, in order to prevent the data from being lost due to unexpected accidents.-8-2.4Operation ModeDisplay changes if the operation key is pressed. * OPERATION *REM/STOP/FOR/JOG (0.0) FOUT 60.0 HzREM: Remote operation is selected.DIR: Operation from the console is selected.FOR/REV:Forward/reverse selection.JOG: JoggingSTART/STOP: Starting or stopping operation.Monitor code number, content and data.2.5How to protect DataOn completion of adjustment, protect data in order to prevent it from being written or lost bymaloperation, etc.(1)Remove the cover from the unit. Open the console to the right.VFC61SW1ON4321Set switch 4 of SW1 on the control PCB (VFC61) to ON.Any data cannot be written in the function mode.(2)Undo the console. Close the cover.Safety precautionBe sure to protect data while the VFC61 is stopped.3.Automatic MeasuringThe exact constants (resistances) of the motor used with inverter should be set in order to run theinverter properly.Carry out automatic measuring for the motor only by disconnecting the motor from the load.Safety precautionAs the voltage is impressed to the motor by automatic measuring, connect the GND terminal of themotor to ground.-9-3.1(1)(2)(3)Inputting Motor DataPress the FUNC key.Select code numb

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论