论洁净空调两种节能措施.doc_第1页
论洁净空调两种节能措施.doc_第2页
论洁净空调两种节能措施.doc_第3页
论洁净空调两种节能措施.doc_第4页
论洁净空调两种节能措施.doc_第5页
已阅读5页,还剩1页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

论洁净空调空气处理过程中的两种节能措施周兴红 徐州建筑职业技术学院 刘 亮 江苏环亚建设工程有限公司摘要 本文介绍了洁净空调空气处理过程中两种节能措施,同时联系实际工程和研究数据对传统的空气调节模式和采取节能措施后进行了比较,节能效果比较明显,对这些办法和成果在实际中的运用给予了讨论和展望。关键词 洁净空调;一次回风;固定二次回风比;干盘管TwoEnergy Saving Measures Of Cleaning Air Conditioning ProcessZhou Xing Hong Xu Zhou Institute of Architectural TechnologyLiu Liang Jiang Su Huan Ya Construction Engineering Limited Company.Abstract: In this paper, twoenergy saving measures of cleaning air conditioning process were introduced. At the same time, Based on contacting the actual project and research data , the traditional air conditioning process was compared with that after taking energy-saving measures , the remarkable energy-saving effect was obtained. Discussed these methods and results in actually engineering project and put forward the outlook finally.Keywords: cleaning air condition;primary return air;fixed ratio of secondary return air;dry coil 0引言在“能源危机”席卷全球的今天,能源消耗正以惊人的速度增长。据我国国情,节约能源已成为当前的一项迫切的任务。而洁净空调是一种初投资大、运行费用高、能耗多的工程项目。空调节能主要指对控制室内温、湿度的空调系统及设备采用先进技术或合理方式以达到节约能耗目的。 我国空调洁净行业起步较晚,业内人士就建筑业内近年来出现的病态建筑综合症、空调综合症、建筑节能等问题进行了广泛深入的研究,但目前仍存在许多问题,当前洁净空调采取的节能措施主要集中在四个方面:合理确定设计参数;优先选用节能设备,积极采用节能技术;加强装备水平,采用先进生产工艺;提高洁净空调的自动化控制水平。本文就洁净空调提出两种节能措施,并通过实际工程计算进行数据比较,以期对洁净空调的发展有一定帮助。1洁净空调几种空气处理方式1.1传统的一次回风空气处理方式传统的空气处理方式是将新风(W)先处理到与室内(N)等焓线与机器露点线的交点(L1),然后与室内回风混合(C),再表冷至机器露点(L2),然后加热至送风状态点(O),送入室内。见图1:图1:传统一次回风空气处理方式作者简介:周兴红,女,1978.1,讲师,徐州建筑职业技术学院1.2固定二次回风比(1:1)空气处理方式固定二次回风比的空气处理方式是先将新风(W)处理到与室内(N)等焓线与机器露点线的交点(L1),然后与室内一次回风混合(C1点),再表冷至机器露点(L2),然后与室内二次回风混合(C2点),最后加热至送风状态点(O),送入室内。见图2: 图2:固定二次回风比的空气处理方式1.3干盘管空调空气处理方式本文提出的空气处理方式:新风(W)通过蒸发器处理到:消除室内余湿量与机器露点线的交点(L1),然后经冷凝器加热至20(P),与室内回风混合,再表冷至送风状态点(O),送入室内。见图3: 图3:干盘管空调空气处理方式2几种空气处理方式比较2.1工程实例计算下面以江苏常州地区一间级洁净手术室的三种处理模式为例进行比较。1) 一次回风处理模式:新风处理到室内等焓线,相对湿度95%状态点参数状态点名称干球温度湿球温度相对湿度含湿量焓W34.628.66422.793.15L117.52179512.0648.18N2417.06509.448.18C23.417.0653.49.748.18L213.713.1959.337.18022.516.4549.346.36由状态点参数结合焓湿图进行计算,结果如下:总送风量(O-N):11000m3/h,新风量:1100m3/h热湿比:=16250Kj/Kg空调制冷量(W-L1):16.49Kw空调制冷量(C-L2):40.33Kw空调总制冷量:56.82Kw空调再热量(L2-O):33.66Kw2) 固定二次回风比处理模式:新风处理到室内等焓线,相对湿度95%状态点参数状态点名称干球温度湿球温度相对湿度含湿量焓W34.628.66422.793.15L117.52179512.0648.18N2417.06509.448.18C122.3817.0558.9810.048.18L213.713.1959.337.18C218.8515.1568.029.3343.71O22.516.4754.39.3346.45由状态点参数结合焓湿图进行计算,结果如下:总送风量(O-N):11000m3/h, 新风量:1100m3/h热湿比:=16250Kj/Kg空调制冷量(W-L1): 16.49Kw空调制冷量(C1-L2):36.65Kw空调总制冷量:29.7Kw空调再热量(C2-O):10.05Kw3)干盘管空调空气处理模式:新风处理到110C,相对湿度95%,再等湿加热到200C状态点参数状态点名称干球温度湿球温度相对湿度含湿量焓W34.628.66422.793.15L11110.57957.7530.64P2014.2653.337.7539.86N2417.06509.448.18C23.616.950.939.2447.35O21.816.2656.89.2445.5由状态点参数结合焓湿图进行计算,结果如下:总送风量(O-N):11000m3/h 新风量:1100m3/h热湿比:=16250Kj/Kg空调制冷量(W-L1):22.94Kw空调制冷量(C-O):6.76Kw空调总制冷量:29.7Kw空调再热量(L1-P):3.36Kw2.2 节能分析传统的空气处理模式在新风上经过一次表冷除湿,循环机组内还有一次除湿过程。送风湿度低、温度较高,常规方式需要再热,大量的冷热抵消,再热造成大量能源浪费。北方多采用蒸汽加湿,对热源品位要求较高、能耗大;南方地区多采用电极式加湿,能耗大,加湿器易损坏。但干盘管空调空气处理模式避免了这种情况:经新风机组处理过度干燥的新风,与回风混合送到室内,抵消了室内的湿负荷。循环机组不用承担除湿过程,只是微调室内的温度。一次回风系统和二次回风系统负荷差异在于一次回风系统有一个较大的再热过程。采用二次回风(固定二次回风比1:1)系统有时需要一个再热微调的过程,但再热量较小。3结论通过上文的分析计算可以看出,通过干盘管空气处理方式需要的总制冷量和再热量是最少的,采用二次回风空气处理方式其次。现在实际工程中,高温高湿西南地区节能效果更为明显,在重庆、湖北荆州、河南安阳、湖南长沙都在已有采用干盘管形式,实际运行情况也是令人满意的。在采用二次回风方式时,对于送风量较大时(大于10000m3上)需降低配电容量、冷水机组容量。目前,我国的很多建筑中的空调系统都具有节能的潜力。建议通过合理选用节能技术,提高空调的能源利用效率和建筑节能设

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论