




已阅读5页,还剩42页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
EMCCLARiiON安装及配置,CLARiiON安装配置,GatherNetworkInformationVerifyPowerSupplySettingsConfirmtheStandbyPowerSupply(SPS)ConnectionsStartTheFC4700InitializetheFC4700ConnectaManagementStationConfigureTheFC4700MakeSwitchAndHostConnectionsSetupTheHostsCreatTheFC4700StorageGroupCompleteTheHostSetupSetupSnapViewAndMirrorViewSoftWareSetupEventMonitor,BeforeYouStart,Confirmthatelectricalwiringisinplaceatyourfacilitytoaccommodatethecabinetstwo240-voltacpowercables.TosupportalloftheFC4700high-availabilityfeatures,youmustconnecteachpowerdistributionunittoadifferentcircuit.2.Verifythatyourfacilityhasadequatenetworkwiringforyoursub-network(subnet)connections.Tomanagethestoragesystem,eachstorageprocessor(SP)requiresaseparatnetworkconnection.,3.IfyourenvironmentincludesswitchesonthepathbetweentheFC4700andthehosts(servers)thathaveaccesstoit,makesuretheswitchesareinstalled.Refertothedevice-specificinstallationmanualsforeachswitch.4.VerifythattheStandbyPowerSupplies(SPSs),DiskProcessorEnclosure(DPE),andanyoptionalDiskArrayEnclosures(DAEs)areinstalledinyourcabinet.Ifnecessary,refertotheappropriatecabinet,rail,ordevicehardwareinstallationdocumentationyoureceivedwithyoursystem.,BeforeYouStart,5.HavethenetworkadministratoratyourfacilitysetupIPaddressesfortheFC47006.MakesurethatthelatestrevisionsofNavisphereManagerandEventMonitorareinstalledontheWindows2000orWindowsNThostyouwilluseastheNavispheremanagementstation.,BeforeYouStart,SP-ASP-BHostname_Upto15alphanumericcharacters.Dashesareacceptable.Specialcharacterssuchasdots,spaces,orunderscoresarenotallowed.Examples:Array1-A,Array1-B.IPAddress_SubnetMask_Gateway_,Step1GatherNetworkInformation,Step2VerifyPowerSupplySetting,Removethediskdrivefanpack.2.Confirmthatthepowerswitchoneachpowersupplybehindthefanpackison,thenreplacethefanpack.,Step3ConfirmtheStandbyPowerSupplyConnection,1.StandbypowersupplyA(SPS-A)connectstothelowerserialport(COM2)ofSP-A.2.StandbypowersupplyB(SPS-B)connectstothelowerserialport(COM2)ofSP-B.,Step4StartFC4700,1.Plugthetwo240-voltacpowercablesintothepoweroutletsinyourfacility.Werecommendconnectingeachpowercabletoadifferentbranchcircuit.ConnectingonlyonepowersourcewilldegradetheFC4700sperformance.,2.Turnonthecircuitbreakersoneachofthecabinetssidepowerstrips.3.Turnonthepowerswitchoneachstandbypowersupply.IfwarninglightsappearonthefrontoftheDPE,makesurethesystemiscorrectlycabled,Step4StartFC4700,Step5InitalizeTheFC4700,InitializingtheFC4700requiresadirectlyconnectedcomputerusuallyalaptopmodelthatwerefertoasaservicelaptop.IMPORTANTThefollowingguidelinesoutlinehowexperiencedtechnicalpersonnelinitializeanFC4700storagesystem.,ServiceLaptopSetup1.ConnecttheservicelaptoptotheserialportonSP-Awiththenullmodemcable.2.MakesureDial-UpNetworkingbetween2PCsisinstalledandsetupontheservicelaptop.3.SetupDial-UpNetworking.4.ModifythelaptopsTCP/IPnetworksettingstouseDHCP.,Step5InitalizeTheFC4700,CriticalParameterSetupOntheFC4700:5.Setupauseraccount.6.CreatethePersistentStorageManagement(PSM)LUN.7.SpecifyprivilegedusersfortheFC4700.8.SettheSPStesttimeforeachSPSinyoursystem.,Step5InitalizeTheFC4700,NetworkInformationSetup9.Specifythehostname,IPaddress,subnetmask,andgatewayaddressforSP-A.UsetheinformationyoucollectedandenteredearlierinStep1,GatherNetworkInformation.10.DisconnecttheservicelaptopfromSP-AandconnectittotheserialportonSP-B.11.Specifythehostname,IPaddress,subnetmask,andgatewayaddressforSP-B.,Step5InitalizeTheFC4700,SPALPHASCSIIDSetup12.UseNavisphereManagertoselecteachFC4700-2SPAgenttobemanaged.13.SettheALPHASCSIIDvalueforeachportonSP-AandSP-B.14.SetthedesiredFCspeedforeachportonSP-AandSP-B.SetupConfirmation15.Makecertainallsoftwarepackagesarecommitted.InNavisphereManager,checktheSoftwaretaboftheArrayPropertiesselectionforanysoftwarepackagesrequiringaCOMMIT.,Step5InitalizeTheFC4700,Step6ConnectaManagementStation,ConnecteachSPseparatelytotheLANtowhichyourNavispheremanagementstationisconnected.,Step7ConfigureTheFC4700System,1.SelecttheFC4700storagesystemyouwanttoconfigure.OptionalFC4700SoftwareInstallation2.IfyouhavetheAccessLogixsoftware,installitwithanondistruptiveinstallation(NDU).IfyouhaveSnapVieworMirrorViewsoftware,installtheminasubsequentNDU.Refertotheoption-specificdocumentationasappropriate.Makecertainallsoftwarepackagesarecommitted.InNavisphereManager,checktheSoftwaretaboftheArrayPropertiesselectionforanysoftwarepackagesrequiringaCOMMIT.Performthecommitifnecessary.,RemoteSPAgentConfiguration3.SpecifyanyadditionalprivilegedusersforeachSP.Storage-SystemPropertiesSetup4.Setthegeneralconfigurationpropertiesenableautomaticpolling,automaticpollingpriority,andSP-AandSP-Bstatisticslogging.5.SetthereadandwritecachememorypropertiesforeachSP.6.SettheFC4700cacheproperties.7.IftheFC4700isrunningAccessLogix,setthedataaccessproperty.,Step7ConfigureTheFC4700System,Removetheprotectivecoversfromeachopticalconnectorandcable.2.PlugthecablesintotheSPhostports.3.ConnecttheotherendofthePort0(top)cableasfollows:Foradirectattachconfigurationtothehostservershostbusadapter.NOTEIftheHBAisnotyetinstalledinthehostserver,completeStep9,thenconnecttheSP.,Step8MakeSwitchorHostConnect,4.ConnecttheotherendofthePort1(bottom)cableasfollows:InasystemwithoutMirrorViewtoanHBAport(directattachconfigurations)orswitchport(SANconfigurations)InasystemwithMirrorViewtoastorageprocessor(SP)hostportontheremotestoragesystem.,Step8MakeSwitchorHostConnect,Step9SetuptheHost,HBAandDriverInstallationCompletethefollowingtasksoneachhostthatwillusethestoragesystem.1.Installthehostbusadapters(HBAs)inthehost.RefertotheEMCFibreChannelHBAandDriverInstallationGuideandEMCFibreChannelHBA/DriverReleaseNotesappropriateforyouroperatingsystem.2.ForaSANconfiguration,connecteachHBAtotheappropriateswitchport.3.Foradirectattachconfiguration,connecteachHBAtotheappropriateSPport.4.InstalltheHBAdriverandanyutilitiesfromtheHBAmedia(ifappropriate)oneachhost.,5.SwitchZoneCreationRefertothedevice-specificdocumentationprovidedwithyourFibreChannelswitch(es)tocompletethefollowing:6.Oneachswitchfabric,createazoneforeachHBAandalltheSPportsthatyouwanttheHBAtoaccess.UseWorldWidePortNames(WWPNs)tospecifytheHBAandtheSPportsforthezone.,Step9SetuptheHost,HBAandDriverInstallation(continued)7.InstallCLARiiONDriverExtension(CDE)softwareifCDEisavailableforyourhost,andyourconfigurationrequiresit.FC4700storagesystemssupportCDEinIBMAIX,SunSolaris,andMicrosoftWindowsNTandWindows2000environments.ConfigurationswithonlyonehostHBArequireCDE.8.Activatethedriver.Dependingonthehost,youmayneedtorebootthehost.,Step9SetuptheHost,NavisphereHostSoftwareInstallation1.IfthehosthasmultipleHBAsconnectedtothestoragesystemandNavisphereApplication-TransparentFailover(ATF)isavailable,installATF.FC4700storagesystemssupportATFinAIX,NovellSolaris,WindowsNTandWindows2000environments.2.InstalltheNavisphereHostAgentandoptionalCLI.3.ActivatetheATFdevicesandHostAgentbyrebootingthehost.4.IfyouplantoinstallSnapViewsoftware,installtheadmsnaphostmanagementutilitysoftware.,Step9SetuptheHost,Step10CreateFC4700StorageGroup,CreateaRAIDGroupRight-clickstoragesystem.Select“CreateRAIDGroup”inmenu.Chooseeitherbasicoradvanceddialog.Inadvanceddialog,diskscanbeselectedmanually.,2.BindaLUNInaRAIDGroup,Step10CreateFC4700StorageGroup,Right-clickstoragesystemicon.Inmenu,select“BindLUN”.Choosebasicoradvancedbinddialog.Selectoptionsandclick“Apply”.,3.AccessLogix,Step10CreateFC4700StorageGroup,Use“DetailedView”togetanoverviewoftheAccessLogixsetup.Select“DetailedView”fromtheright-clickmenuforthestoragesystem.Alliconsareactive.,4.TurningOnAccessLogixusingNavisphereManager,Step10CreateFC4700StorageGroup,Right-clickstoragesystemiconandselect“Properties”.Goto“DataAccess”tab.Checkthe“AccessControlEnabled”checkbox.Click“OK”.Cannotbeunchecked!,5.CreatinganddestroyingStorageGroupsusingManager,Step10CreateFC4700StorageGroup,Right-clickstoragesystemiconandselect“CreateStorageGroups”.Specifynameforstoragegroup.MoveLUNstothe“SelectedLUNs”area.CheckwhetherSGshouldbededicatedorsharable.,6.ConnectingHostsUsingNavisphereManager,Step10CreateFC4700StorageGroup,Findstoragegroupin“StorageGroups”folderin“Storage”tab.Right-clickSGandselect“ConnectHosts”.Movehostsbetweenareas.Click“OK”or“Apply”.,7.ChangingStorageGroupSettingsUsingNaviManager,Step10CreateFC4700StorageGroup,Right-clickstoragegroupiconandselect“Properties”.Makechangesinthepropertydialog.Click“OK”or“Apply”.,8.AddingorRemovingLUNsfromStorageGroupusingManager,Step10CreateFC4700StorageGroup,Inpropertydialogforstoragegroup,click“SelectLUNs”.MoveLUNsbetweenthetwoareas.Click“OK”.Click“OK”againinpropertiesdialog.,Step11CompletetheHostSetup,RefertotheappropriateEMCNavisphereServerSoftwareSetupGuidetocompletethefollowingforeachhostthatwillusethestoragesystem.1.MaketheLUNsforeachhostavailabletothehostsoperatingsystem.Dependingontheoperatingsystem,thismayinvolve:LabelingandpartitioningLUNsMakingfilesystemsorcreatingvolumesonthepartitionsMountingthefilesystemsorvolumes.2.Ifhostsareclustered,setuptheclusteringsoftwaretoworkwiththeFC4700-2.clicksessionSelect“Properties.”,CLARiiONCX600,InitializingtheCX600WithNavisphere6.1,Overview,ConfigurationstepssimilartoFC4700withNavisphere6.05(noPSMsetup)ServiceLaptopRequirements:WindowsNTorWindows2000InternetExplorer5.5orNetscape6.0JavaRuntimeEnvironment1.3.1_01Navisphere6.1ManagementUI(new)SerialPPPConnectionSerialCable,InitializingtheCX600,ConfiguretheServiceLaptopSettheStorageProcessorTCP/IPParametersforSP-AandSP-BSettheArrayDateandTimeConfigureOperatingParametersCommitBaseSoftwarePerformNDUtoUpgradeorAddOptionalSoftwareComponentsConfigureRead/WriteCacheCreateRAIDGroups,StorageGroups,BindLUNs,andConnectHosts,ConfiguringtheServiceLaptop,InstalltherequiredServiceUINavispheresoftwareJava1.3.1_01Navisphere6.1WindowsUINavisphereCLICreateaWindowsdial-upnetworkingPPPconnection,ConfigureSP-AIPParameters,ConnectserialcabletoSP-AEstablishaPPPnetworkconnectiontoSP-AOpenInternetbrowserto:/setupSetnetworkpropertiesforSP-AIPAddress,Hostname,SubnetMask,Gateway,PeerIPAddressApplysettings(SP-Areboots)DisconnectserialcablefromSP-A,StorageProcessorNetworkSetupViaSerialPPPSession,ConfigureSP-BIPParameters,ConnectserialcabletoSP-BEstablishaPPPnetworkconnectiontoSP-BOpenInternetbrowserto:/setupSetnetworkpropertiesforSP-BIPAddress,Hostname,SubnetMask,Gateway,PeerIPAddressApplysettings(SP-Breboots)DisconnectserialcablefromSP-B,RestartSP-AsManagementServer,Re-connecttheserialcabletoSP-AEstablishPPPsessiontoSP-AOpenInternetbrowserto:/setupClickRestartManagementServerCheckYestorestarttheManagementServerWait60SecondsfortheManageme
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 家庭农场动物疫病防治合作合同书
- 避暑山庄说明文500字10篇
- 企业流程改进设计与执行工具
- 多方联合开发游戏合同
- 湖南省浏阳市三中2026届化学高一上期末检测模拟试题含解析
- 农业机械购置与维修保养合同书
- 促销员劳务合同
- 读后感中国民间故事1000字(8篇)
- 空中作业机械租赁协议
- 2025年村级儿童之家保洁员招聘笔试题库附答案
- 中药饮片采购配送服务投标方案
- 风光电站网络信息系统安全事故应急演练方案
- 五大神电力华煤炭公司劳动定员统一标准
- WB/T 1036-2006菱镁制品用玻璃纤维布
- 【词汇】高中英语新教材词汇总表(共七册)
- 北京市各县区乡镇行政村村庄村名明细
- 笔迹、指纹鉴定申请书
- 长沙市历年中考数学试卷,2014-2021年长沙中考数学近八年真题汇总(含答案解析)
- 【英语】人教版英语八年级英语下册阅读理解专题复习练习(含解析)
- 《植物生理学》课件第四章+植物的呼吸作用
- 2022年出差管理制度员工出差管理制度
评论
0/150
提交评论