




全文预览已结束
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
SR2131470报告 问题描述 BSC11在9月14日下午13:28左右重启,14:20左右恢复.9月15日凌晨 ,对BSC11进行GCLK倒换的过程中,发现KSW报出4&6告警.怀疑提供时钟的MSI存在问题,将其更换后送至Motorola硬件研发部门进行分析。 问题分析/调查过程1) 9月15日凌晨现场处理的过程 倒换GCLK之前没有KSW的4&6告警 15/09/06 00:10:33 MMI-RAM 0115 - disp_act 0ACTIVE ALARM INFORMATION FOR LOCATION 0:Device Alarm Clear (Subtype) Code Type Tag(hex) Date/Time Description- - - - - -MMS 55 0 0 16 FMIC 00000001 09-14-2006 Synchronization Loss OOS 14:37:13 Timer Expired Estimated restoral-60.0 secsMMS 54 1 0 16 FMIC 00000001 09-14-2006 Synchronization Loss OOS 14:37:08 Timer Expired Estimated restoral-60.0 secsMMS 54 0 0 16 FMIC 00000001 09-14-2006 Synchronization Loss OOS 14:37:08 Timer Expired Estimated restoral-60.0 secsMMS 3 0 0 16 FMIC 00000001 09-14-2006 Synchronization Loss OOS 14:37:14 Timer Expired Estimated restoral-60.0 secs 倒换主备GCLK成功 15/09/06 00:18:36 MMI-RAM 0115 - swap 0 gclkGCLK swap may cause alarms on other devices.The swap may take approx. 10 seconds.Are you sure (y=yes,n=no)? yCOMMAND ACCEPTED15/09/06 00:19:45 MMI-RAM 0115 - !state 0 gclk * *DEVICE STATUS INFORMATION FOR LOCATION 0:OPER STATES: D:Disabled E:Enabled B:BusyADMIN STATES: L:Locked U:Unlocked E:Equipped S:Shutdown Last Transition RelatedDevice State Reason dd/mm hh:mm:ss Function- - - - -GCLK 0 0 0 B-U GCLK Phase Locked 15/09 00:18:51 NoneGCLK 1 0 0 E-U GCLK Phase Locked 15/09 00:18:51 None 倒换后报出KSW 4&6告警15/09/06 00:20:18 MMI-RAM 0115 - !ddisp_act 0ACTIVE ALARM INFORMATION FOR LOCATION 0:Device Alarm Clear (Subtype) Code Type Tag(hex) Date/Time Description- - - - - -MMS 55 0 0 16 FMIC 00000001 09-14-2006 Synchronization Loss OOS 14:37:13 Timer Expired Estimated restoral-60.0 secsMMS 54 1 0 16 FMIC 00000001 09-14-2006 Synchronization Loss OOS 14:37:08 Timer Expired Estimated restoral-60.0 secsMMS 54 0 0 16 FMIC 00000001 09-14-2006 Synchronization Loss OOS 14:37:08 Timer Expired Estimated restoral-60.0 secsMMS 3 0 0 16 FMIC 00000001 09-14-2006 Synchronization Loss OOS 14:37:14 Timer Expired Estimated restoral-60.0 secsKSW 3 1 0 6 FMIC Untagged 09-15-2006 6.12 Second Reference Loss (KSW) 00:18:52KSW 3 0 0 6 FMIC Untagged 09-15-2006 6.12 Second Reference Loss (KSW) 00:18:52KSW 2 1 0 6 FMIC Untagged 09-15-2006 6.12 Second Reference Loss (KSW) 00:18:52KSW 2 0 0 6 FMIC Untagged 09-15-2006 6.12 Second Reference Loss (KSW) 00:18:52KSW 1 1 0 6 FMIC Untagged 09-15-2006 6.12 Second Reference Loss (KSW) 00:18:52KSW 1 0 0 6 FMIC Untagged 09-15-2006 6.12 Second Reference Loss (KSW) 00:18:52KSW 0 1 0 6 FMIC Untagged 09-15-2006 6.12 Second Reference Loss (KSW) 00:18:52KSW 0 0 0 4 FMIC Untagged 09-15-2006 Clock A Signal Loss (KSW) 00:18:52KSW 0 0 0 6 FMIC Untagged 09-15-2006 6.12 Second Reference Loss (KSW) 00:18:52 这些KSW的告警属于倒换GCLK过程中的正常现象,它们在GCLK倒换成功后由主用BSP自动清除2)将MSI插入Motorola实验室的BSC后,这些KSW依然会在倒换GCLK过程中出现,但在几分钟后自动清除 倒换主备GCLK成功 09/10/06 18:11:29 MMI-RAM 0115 - swap 0 gclkGCLK swap may cause alarms on other devices.The swap may take approx. 10 seconds.Are you sure (y=yes,n=no)? yCOMMAND ACCEPTED倒换后报出KSW 4告警 09/10/06 18:11:53 MMI-RAM 0115 -* (4) Clock A Signal Loss* - Severity: CRITICAL Category: EQUIPMENT* - KSW 0 1 0 (KSW)* - Site: 0 Cage: 0 Slot: 1* - Functional Unit: Site 0* - Time: Mon 9/10/2006 18:11:59:000* - Alarm Type: Fault Management Initiated Clear* - FRU Serial Number: X56FZW1X8S* - FRU KIT Number: SLN7131ECB* - Hardware Version Number(hex): 05* (4) Clock A Signal Loss* - Severity: CRITICAL Category: EQUIPMENT* - KSW 0 0 0 (KSW)* - Site: 0 Cage: 0 Slot: 27* - Functional Unit: Site 0* - Time: Mon 9/10/2006 18:11:59:000* - Alarm Type: Fault Management Initiated Clear* - FRU Serial Number: X56FZW0FSW* - FRU KIT Number: SLN7131ECB* - Hardware Version Number(hex): 05* (4) Clock A Signal Loss* - Severity: CRITICAL Category: EQUIPMENT* - KSW 1 0 0 (KSW)* - Site: 0 Cage: 1 Slot: 27* - Functional Unit: Site 0* - Time: Mon 9/10/2006 18:11:59:000* - Alarm Type: Fault Management Initiated Clear* - FRU Serial Number: X56X2D0465* - FRU KIT Number: SLN7131ECB* - Hardware Version Number(hex): 05 一分钟后告警自动清除 09/10/06 18:12:52 MMI-RAM 0115 -* (4) Clock A Signal Loss* - Severity: CLEAR Category: EQUIPMENT* - KSW 0 1 0 (KSW)* - Site: 0 Cage: 0 Slot: 1* - Functional Unit: Site 0* - Time: Mon 9/10/2006 18:13:51:860* - Alarm Type: Fault Management Initiated Clear* - FRU Serial Number: X56FZW1X8S* - FRU KIT Number: SLN7131ECB* - Hardware Version Number(hex): 05* (4) Clock A Signal Loss* - Severity: CLEAR Category: EQUIPMENT* - KSW 0 0 0 (KSW)* - Site: 0 Cage: 0 Slot: 27* - Functional Unit: Site 0* - Time: Mon 9/10/2006 18:13:51:860* - Alarm Type: Fault Management Initiated Clear* - FRU Serial Number: X56FZW0FSW* - FRU KIT Number: SLN7131ECB* - Hardware Version Number(hex): 05* (4) Clock A Signal Loss* - Severity: CLEAR Category: EQUIPMENT* - KSW 1 0 0 (KSW)* - Site: 0 Cage: 1 Slot: 27* - Functional Unit: Site 0* - Time: Mon 9/
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025古董交易合同模板(合同样本)
- 温室农业环境智能化监测系统在节能减排中的应用报告
- 园林工程材料采购方案(3篇)
- 法国机械工程培养方案(3篇)
- 2025年数字音频技术试卷及答案
- 脊柱感染术后护理课件
- 车间安全培训亮点汇报课件
- 公路工程专项方案编制(3篇)
- 脊柱侧弯康复课件
- 脊柱与骨盆骨折课件
- 建筑公司法务知识培训课件
- 2025.9.3抗战胜利大阅兵初高中学生征文(高中):观九三阅兵有感
- 2025食品安全员能力考核试题及答案附含答案
- 2025年度深圳住房租赁合同范本
- 湖南名校联考联合体2026届高三上学期第一次联考(暨入学检测)英语试题+答案
- 《创新创业基础》 课件 第1章 创新创业概述
- 商业保理考试试题及答案
- 接触网运行与检修课件
- 70周岁老人驾考三力测试题库及答案
- DBJ04-T 491-2025 建设工程消防设计审查验收文件归档标准
- 镇静催眠药物临床合理使用指南
评论
0/150
提交评论