




免费预览已结束,剩余3页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
现代化学实验与技术(仪器分析实验)废水中三苯含量的气相色谱分析摘要 本实验以正己烷为内标物,采用毛细管气相色谱法测定废水样品中的三苯含量,通过程序升温分离废水中各种杂质,检测出水样中苯、甲苯、邻二甲苯和对二甲苯的含量分别为5.384 mgL-1、4.847 mgL-1、3.419 mgL-1和6.030 mgL-1,不符合国家污水综合排放标准。该测定方法简单省时,灵敏度高,达到预期检测效果。关键字 毛细管气相色谱法 废水 三苯含量 Determination of Benzenes in Waste Water by Capilary Column Gas ChromatographyAbstract: This paper studies the method of determination of benzenes in waste water by capilary column gas chromatography. According as the requirement of experiment, program temperature increasing is applied, and n-hexane is regarded as internal standard substance to measure the content of benzene, toluene and xylene. The content of benzene, toluene, o-xylene and p-xylene in the waste water sample is 5.384 mgL-1, 4.847 mgL-1, 3.419 mgL-1and 6.030 mgL-1 respectively, and the sample does not meet national waste water discharge standards. The method is simple, rapid and sensitive,.Key words: Benzenes; waste water; capilary column gas chromatography; 1. 前言苯、甲苯、二甲苯工业上俗称三苯,作为化工原料或溶剂,广泛应用于染料工业、农药生产、香料制作、造漆、喷漆、制药、制鞋、家具制造等行业。三苯均为无色透明油状液体,具有强烈芳香味,易挥发为气体,易燃有毒。三苯侵入人体途径包括吸入、食入、经皮肤吸收。其毒性作用于人的中枢神经系统和造血组织1。三苯毒性很大,是生活饮用水、地表水质量标准和污水排放标准中控制的有毒物质指标。国家于1998年1月1日开始实行GB 8978-1996 污水综合排放标准2,控制和管理未达标的水体进入河道、水库等。常用的三苯含量分析方法为硝化比色法3和气相色谱法1。而气相色谱法更为常用。本文建立用毛细管气相色谱测定废水中三苯含量的方法,用二硫化碳萃取废水中的三苯及其他成分,萃取试液通过汽化,在毛细管色谱柱中分离,最后由检测器检测混合成分及其浓度,记录其色谱图,通过与各个单标的峰值对比,最终确定各成分及含量。该方法操作简单,分析速度快,为工业生产中控制污水排放和环保部门检测污水提供有效方法。2. 实验部分1.2.2.1. 仪器与试剂1.2.2.1.2.1.1. 仪器Agilent4890D型气相色谱仪;氢火焰离子化检测器(FID);毛细管色谱柱:HP5,以聚氧化硅烷-聚乙二醇为固定相(30 m0.25 mm0.25 m);1 L、5 L微量进样器;色谱工作站。气相色谱条件:汽化温度为200 ;检测器温度为250 ;载气(N2)总量为40 mLmin-1,分流比为30:1;氢气和空气流量分别为30 mLmin-1和300 mLmin-1;程序升温:初始温度40 ,保持2 min,升温速率为20 min-1并升至150 ;进样量0.51 L。1.2.2.1.2.1.1.2.1.2. 试剂苯、甲苯、二甲苯、正己烷均为色谱纯;乙酸乙酯、二硫化碳为分析纯。各组分标准溶液:于6个5-10 mL血清瓶中分别称取苯、甲苯、间二甲苯、对二甲苯、邻二甲苯和正己烷各0.02-0.03g,加入5.0 mL乙酸乙酯溶解、摇匀,于冰箱内保存(准备室配制)。1.2.2.1.2.2. 实验方法1.2.2.1.2.2.2.2.1. 方法原理废水试样中的三苯经二硫化碳溶剂萃取,萃取液经毛细管色谱柱分离、氢火焰离子化检测器(FID)检测后,记录其色谱图,并用来进行定量分析。内标法是将一定的内标物加入样品后进行分离,然后根据样品质量M、内标物质量(正己烷ms)以及组分和内标物的峰面积(Ai和As)按下式求出组分含量:Pi=fiAiMsAsM100% (1)式中fi为被测组分对内标物(此处也是基准物)的相对定量校正因子,其计算式为:fi=AsmiAims (2)式中,Ai和As分别为标准溶液中被测组分和内标物的峰面积;mi和ms分别为标准液中被测组分和内标物质量。2.2.2. 实验步骤(1) 加有基准物的混合标准溶液配制(实验室已准备)在一个5-10 mL血清瓶中预先放入约2 mL乙酸乙酯,分别准确称取苯、甲苯、间二甲苯、对二甲苯、邻二甲苯和正己烷0.02-0.03 g(准确至0.0002 g)于血清瓶中,用乙酸乙酯溶解并稀释至5mL,摇匀。(2) 废水样品前处理取废水样100 mL,加入5 L内标物正己烷,于100 mL分液漏斗中,加5.0 mL二硫化碳萃取 3 min,静止分层,弃去水相。(3) 定性分析启动仪器,设定色谱分析条件等,使仪器进入正常工作状态。待色谱基线平直后分别将三苯单标、正己烷依次进样,记下每种物质的保留时间,作为混合标准以及样品测定的对照定性依据。(4) 相对校正因子fi的测定注入1 L混合标准溶液,以各纯组分的保留时间与混合标样中色谱图中各色谱峰对照定性。并计算以正己烷为基准物的相对定量校正因子fi。(5) 样品测定注入1 L步骤(2)中萃取后样品溶液,以各纯组分的保留时间与样品色谱图中各色谱峰对照定性。并依据内标法计算样品含量。3. 结果与讨论1.2.3.3.1. 数据记录与结果计算3.1.1. 混合标准待测组分及内标物的定性表1 纯标与混标在色谱图中保留时间tR名称保留时间 tR/min纯标混标苯3.0413.046甲苯4.0414.049对二甲苯5.1795.176邻二甲苯5.4405.438正己烷2.5482.5433.1.2. 以正己烷为内标物计算待测组分相对定量校正因子fi表2 待测组分的fi值待测组分10 mL混合溶液中含量/g峰面积fi正己烷365456081.000苯355378841.171甲苯343356841.201对二甲苯376660280.7116邻二甲苯421511251.029f苯= (A正己烷m苯)/(A苯m正己烷) = (45608355g)/(37884365g) = 1.171f甲苯= (A正己烷m甲苯)/(A甲苯m正己烷) = (45608343g)/(35684365g) = 1.201f对二甲苯= (A正己烷m对二甲苯)/(A对二甲苯m正己烷) = (45608376g)/(66028365g) = 0.7116f邻二甲苯= (A正己烷m邻二甲苯)/(A邻二甲苯m正己烷) = (45608421g)/(51125365g) = 1.0293.1.3. 废水样品中待测组分及内标物的定性表3 纯标与废水样品色谱图中各峰保留时间对照名称保留时间 tR/min纯标废水样品苯3.0413.015甲苯4.0414.036对二甲苯5.1795.171邻二甲苯5.4405.435正己烷2.5482.5353.1.4. 废水样品中三苯含量表4 废水样品中三苯含量组分fi峰面积样品中组分质量/mg浓度/mgL-1苯1.171152640.53845.384甲苯1.201133980.48474.847对二甲苯0.7116159520.34193.419邻二甲苯1.029194540.60306.030由(1)式可得转化得:m组分= PiM=fiAiMsAs100% (3)正己烷的峰面积为As109600,密度为0.6603 gcm-3。样品中内标物正己烷体积为5.0 L,故废水样品中内标物正己烷质量为:ms = 0.6603 gcm-35.0 L = 3.30210-3 g。将表2中算出的fi、各组分的峰面积Ai,以及内标物正己烷的质量ms和峰面积As代入(3)式中求得样品中各组分含量和浓度,如表41.2.3.3.1.3.2. 讨论3.2.1. 实验结果从实验结果得到,废水样品中苯、甲苯、对二甲苯以及邻二甲苯的含量分别为5.384 mgL-1、4.847 mgL-1、3.419 mgL-1和6.030 mgL-1。根据国家污水排放标准规定:排入设置二级污水处理厂的城镇排水系统的污水,执行三级标准,即水样中,苯 0.5 mgL-1,甲苯 0.5 mgL-1,二甲苯 1.0 mgL-1。2实验中的废水样品苯和甲苯含量分别超标967.8 %和869.4 %,二甲苯超标214.9 %和503.0 %,属严重超标。此水样不符合国家污水排放规定。3.2.2. 程序升温程序升温是指在色谱进样后,在一次样品分析的周期内,按一定的速度和以预先设定好的升温程序,让整个色谱柱随着分析时间的延长,呈线性或非线性升温,使柱温与组分的沸点相互对应,以使低沸点组分和高沸点组分在色谱柱中都有适宜的保留、色谱峰分布均匀且峰形对称,以达到样品中各种组分的完全分离的目的。3.2.3. 检测器温度的控制 检测器的温度一般要高于柱温,防止待测物质进入检测器后冷却凝结,影响测定,同时,待测物质凝结后残留在检测器中,难以清除,对仪器造成损坏。3.2.4. 双柱定性不同的物质在同一根柱子上可能会有相同的保留时间,但在两根不同极性的柱子上一般不可能会有相同的保留时间,双柱定性就是利用这个原理,将两种组分分别定性。3.2.5. 定量校正因子的作用 色谱定量分析中同一台仪器,在一定的实验条件中,测量不同的物质,由于其性质的差异,仪器对检测物质的灵敏度不同,即时浓度或质量一样,色谱图上对应物质的峰面积不一定一样。所以在计算时,将面积乘以一个定量校正因子fi ,使得组分面积转换成相应的物质的量来求解。3.2.6. 分流进样分流进样就是把注入色谱仪的样品经气化后,一部分进入色谱柱,而另一部分(一般是大部分)通过分流放空。由于柱内固定相的量少,柱对样品的容量比填充柱低,分流就是为了防止色谱过载。3.2.7. 气相色谱分析中控制的实验条件气相色谱分析中,若要提高分离度,就需要控制:1. 根据分离物质的极性,选择合适的色谱柱,使得要分离的混合物都能较好的出峰。2. 选择的合适柱温。柱温低有助于组分的分离,但柱温过低,组分有可能在柱中冷凝,或传质阻力增加,使色谱峰扩张,甚至拖尾;柱温高虽然有利于传质,但分配系数变小不利于分离。选择最佳柱温,原则是使物质既完全分离,又不使峰形扩张,拖尾。柱温一般选择各组分沸点平均温度或稍低。3. 控制进样量,并保持进样时,样品都能同时进入汽化室汽化。否则样品汽化后会被载气稀释,使峰形变宽,并且不对称,既不利于分离,也不利于定量。4. 选择合适的气化温度,既要保持样品迅速且完全汽化,又不引起样品分解。若要缩短分析时间,就需要:1. 根据使用的检测器而选择载气的种类。比如使用TCD,选用氢或氦作载气,能提高灵敏度;使用FID 则选用氮气作载气。然后再考虑所选的载气要有利于提高柱效能和分析速度。例如选用摩尔质量大的载气(如N2)可以使Dg 减小,提高柱效能。再根据速率方程,选择合适的载流速度。 2. 在保证合适的柱温和分离效果下,适当提高程序升温的升温速率。3.3.1.3.2.1.2.3.3.1.3.2.4. 结论本实验采用毛细管气相色谱法测定废水样品中三苯的含量,测得水样中苯、甲苯、邻二甲苯和对二甲苯的含量分别为5.384 mgL-1、4.847 mgL-1、3.419 mgL-1和6.030 mgL-1
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 生育服务保障承诺书(5篇)
- 公交司机考试题库及答案
- 软件开发测试及维护合同书
- 滑县特岗地理考试真题及答案
- 枣庄物理中考试题及答案
- 汽车美容及维修服务合同书
- 合肥七中考试题型及答案
- 光电器件技术考试题库及答案
- 软件测试笔试题及答案解析大全
- 入伍政治考核笔试题及答案
- 小学道德与法治学科教师专业素质考试试题及答案
- GB∕T 23322-2018 纺织品 表面活性剂的测定 烷基酚和烷基酚聚氧乙烯醚
- 全国质量奖现场汇报材料(生产过程及结果)课件
- 政策评价-卫生政策分析课件
- 高中物理实验—测定物体的速度及加速度(含逐差法)
- 饮食习惯与健康
- 华为人力资源管理纲要2.0
- 第二章 园艺设施的类型、结构、性能及应用
- 银行卡收单外包服务协议范本
- 流动资金缺口测算表.xls
- 中国空白地图大全(可直接打印)(共49页)
评论
0/150
提交评论