




免费预览已结束,剩余1页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
2 channel multi-function wireless controller Features:1 Operating voltage: DC 9-13V (recommended DC 12V);5V version can be customized2 Operating Current: All relays close, about 14MA; one relay open,about 43MA;two relay open,about 71MA3 Operating frequency: 433.92M; 315M version can be customized 4 Receiver sensitivity : -108dBm5 Decode : learning code, can be adapted EV1527 / PT2262 and compatible remote control, you can store up to 16 remote control6 Work mode : Non-locking (Momentary is defult),Self-locking (Toggle),Inter-locking (Latch), Delay;Each channel independently set the Work mode;500,000 seconds maximum delay7 Size(Including housing)75*54*28mm8 Relay Maximum load(Recommended5A):10A/250VAC,10A/125VAC,10A/30VDC, 10A/28VDC ,10A/12VDCWork mode Channel 1modeDelay rangeChannel 1modeDelay rangeChannel 1(CH1)Channel 1(CH2)Momentary /Non-locking (Mode 0)0.5 secondsMomentary /Non-locking (Mode 0)0.5 secondsToggle /Self-locking(Mode 1)NonToggle /Self-locking(Mode 1)NonLatch /Inter-locking(Mode 2)NonLatch /Inter-locking(Mode 2)NonDelay 1(Mode 3)0.1-100 SecondsStepper :0.1 SecondsDelay 1(Mode 3)0.1-100 SecondsStepper :0.1 SecondsDelay 2(Mode 4)1-1000 SecondsStepper :1 SecondsDelay 2(Mode 4)1-1000 SecondsStepper :1 SecondsDelay 3(Mode 5)10-10000 SecondsStepper :10 SecondsDelay 3(Mode 5)10-10000 SecondsStepper :10 SecondsDelay 4(Mode 6)100-100000 SStepper :100 SDelay 4(Mode 6)100-100000 SStepper :100 SDelay 5(Mode 7)500-500000 SStepper :500 SDelay 5(Mode 7)500-500000 SStepper :500 SWorking mode user guide : 1: Each Channel have 4 working mode : Delay time , Toggle mode (singnal Self-locking), Momentary Mode ( singnal None-locking) , Latch mode (singnal Inter-locking) . 2: working mode of each channel need to be set individually , 2 channels can have 10 different working mode combinenatoin ,Detail : one channel is Momentary , the other channel is Latch ;one channel is Momentary , the other channel is Momentary ; one channel is Momentary , the other channel is Toggle ;oone channel is Momentary , the other channel is Delay time ;one channel is Toogle , the other channel is Delay Time ;one channel is Toogle , the other channel is Latch ;one channel is Toogle , the other channel is Toggle ;one channel is Latch , the other channel is Delay Time ;one channel is Latch , the other channel is Latch ;one channel is Delay time , the other channel is Delay Time ;3: Time of each delay mode is proportionally increased. For example, you want to channel 1 to delay 50 seconds , 500seconds and 5000 seconds, you can first seting channel 1 is set to delay 1 (Delay Mode 3), turn around (CH1_adj) adjustable resistance, so that channel 1 delay 50 seconds; if the mode is set to delay 2 (mode 4), the delay time becomes 500 seconds, if the mode is set to delay 3 (mode 5), the delay time becomes 5000 seconds4 With a suitable screwdriver and gently rotating adjustable resistance;Clockwise, increasing delay,Counter-clockwise, the delay is reducedGlossary:NO : Relay normally open contactCOM : Relay common contactNC : Relay normally closed contactOpen : NO connection COM, NC disconnect COMClose : NO disconnect COM, NC connection COMMomentary : Press the Transmitter button A, the receiver Channel 1 is Open, release button A; the receiver Channel 1 is Close, the same as B ,Every Channel is Independent ;Toggle : Press transmitter button A for 1 time , the receiver Channel 1 is Open, press button A again, the receiver Channel 1 is Close, the same as B. Every Channel is Independent ;Latched : Press transmitter button A, the receiver Channel 1 is Open, the Channel 2 is Close. Press transmitter button B, the receiver Channel 2 is Open, the Channel 1 is Close.Delay : Press the Transmitter button A, the receiver Channel 1 is Open,After a set time delay, the receiver Channel 1 is Close, the same as B ,Every Channel is Independent;If during the delay, press the button of Transmitter, delay start again; if the delay period, press and hold the button of Transmitter 3-4 seconds, the receiver controller stops the delay, the relay CloseAdapter remote control (learning remote control):Under normal operating mode, LED will be lit, when receives a valid remote control (EV1527 / PT2262) button values, LED flashesClean code: press the button and held down, LED off, LED will light about 8 seconds later, clean code is completed (Note: After performing clean code previously stored remote control value does not exist)Step 1 (into the learning mode): Press the button (about 1 second), LED off;Step 2 (adapter channel 1): Then press the first button on the remote control, LED flashes four times off, then learning the first button valueStep 3 (Adaptation Channel 2): Then press the second button on the remote control, LED flashes four times brighter, then learned two key valuesWiring Diagram:1 DC 12V control circuit,Wiring diagra
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 出租膨化设备合同范本
- 线上生活体验课程合同
- 采购合同范本壁布
- 审计招投标合同范本
- 单位清洁服务合同范本
- 钻机维修合同范本
- 亨廷顿病舞蹈样动作护理查房
- 买卖房协议合同范本
- 拍摄微电影合同范本
- 小型船舶建造合同范本
- 复发性流产护理
- 2025年西藏自治区事业单位招聘考试教师招聘体育学科专业知识试卷(模拟试题)
- 先天性甲状腺功能减退症诊治指南解读课件
- 2025至2030中国裸眼3D行业产业运行态势及投资规划深度研究报告
- 检修安全监护管理制度
- 产科工作管理制度
- 初中历史教师业务考试试题及答案
- 导尿管相关尿路感染预防与控制试题(附答案)
- 中医烧伤课件
- 2025-2030中国水下混凝土行业市场发展趋势与前景展望战略研究报告
- GB/T 30134-2025冷库管理规范
评论
0/150
提交评论