电池参数设置_第1页
电池参数设置_第2页
电池参数设置_第3页
电池参数设置_第4页
电池参数设置_第5页
已阅读5页,还剩7页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

DescriptionThe Battery block implements a generic dynamic model parameterized to represent most popular types of rechargeable batteries.The equivalent circuit of the battery is shown below:Lead-Acid ModelDischarge model (i* 0)f1(it,i,i,Exp)=E0KQQitiKQQitit+Laplace1(Exp(s)Sel(s)0).Charge Model (i* 0)f1(it,i,i)=E0KQQitiKQQitit+Aexp(Bit).Charge Model (i* 0)f1(it,i,i,Exp)=E0KQQitiKQQitit+Laplace1(Exp(s)Sel(s)0).Charge Model (i* 0)f2(it,i,i,Exp)=E0KQit+0.1QiKQQitit+Laplace1(Exp(s)Sel(s)1s),where,EBatt= Nonlinear voltage (V)E0= Constant voltage (V)Exp(s)= Exponential zone dynamics (V)Sel(s)= Represents the battery mode. Sel(s) = 0 during battery discharge, Sel(s) = 1 during battery charging.K = Polarization constant (Ah1) or Polarization resistance (Ohms)i* = Low frequency current dynamics (A)i = Battery current (A)it = Extracted capacity (Ah)Q = Maximum battery capacity (Ah)A = Exponential voltage (V)B = Exponential capacity (Ah)1The parameters of the equivalent circuit can be modified to represent a particular battery type, based on its discharge characteristics. A typical discharge curve is composed of three sections, as shown in the next figure:The first section represents the exponential voltage drop when the battery is charged. Depending on the battery type, this area is more or less wide. The second section represents the charge that can be extracted from the battery until the voltage drops below the battery nominal voltage. Finally, the third section represents the total discharge of the battery, when the voltage drops rapidly.When the battery current is negative, the battery will recharge following a charge characteristic as shown below:Note that the parameters of the model are deduced from discharge characteristics and assumed to be the same for charging.The Exp(s) transfer function represents the hysteresis phenomenon for the Lead-Acid, NiCD and NiMH batteries during charge and discharge cycles. The exponential voltage increases when battery is charging, no matter the SOC of the battery. When the battery is discharging, the exponential voltage decreases immediately:Dialog Box and ParametersParameters TabBattery typeProvides a set of predetermined charge behavior for four types of battery: Lead-Acid Lithium-Ion Nickel-Cadmium Nickel-Metal-HydrideNominal Voltage (V)The nominal voltage (Vnom) of the battery (volts). The nominal voltage represents the end of the linear zone of the discharge characteristics.Rated Capacity (Ah)The rated capacity (Qrated) of the battery in ampere-hour. The rated capacity is the minimum effective capacity of the battery.Initial State-Of-Charge (%)The initial State-Of-Charge (SOC) of the battery. 100% indicates a fully charged battery and 0% indicates an empty battery. This parameter is used as an initial condition for the simulation and does not affect the discharge curve (when the optionPlot Discharge Characteristicsis used).Use parameters based on Battery type and nominal valuesLoad the corresponding parameters in the entries of the dialog box, depending on the selectedBattery type, theNominal Voltageand theRated Capacity.When a preset model is used, the detailed parameters cannot be modified. If you want to modify the discharge curve, select the desired battery type to load the default parameters, and then uncheck theUse parameters based on Battery type and nominal valuescheckbox to access the detailed parameters.Maximum Capacity (Ah)The maximum theoretical capacity (Q), when a discontinuity occurs in the battery voltage. This value is generally equal to 105% of the rated capacity.Fully charged Voltage (V)The fully charged voltage (Vfull), for a given discharge current. Note that the fully charged voltage is not the no-load voltage.Nominal Discharge Current (A)The nominal discharge current, for which the discharge curve has been measured. For example, a typical discharge current for a 1.5 Ah NiMH battery is 20% of the rated capacity: (0.2 * 1.5 Ah / 1h = 0.3A).Internal ResistanceThe internal resistance of the battery (ohms). When a preset model is used, a generic value is loaded, corresponding to 1% of the nominal power (nominal voltage * rated capacity of the battery). The resistance is supposed to be constant during the charge and the discharge cycles and does not vary with the amplitude of the current.Capacity (Ah) Nominal VoltageThe capacity (Qnom) extracted from the battery until the voltage drops under the nominal voltage. This value should be betweenQexpandQmax.Exponential zone Voltage (V), Capacity (Ah)The voltage (Vexp) and the capacity (Qexp) corresponding to the end of the exponential zone. The voltage should be betweenVnomandVfull. The capacity should be between 0 andQnom.View Discharge Characteristics TabPlot Discharge CharacteristicsClick to plot a figure containing two graphs. The first graph represents the nominal discharge curve (at theNominal Discharge Current) and the second graph represents the discharge curves at the specified discharge currents.Discharge currentAllows to specify different values of discharge current. The discharge characteristics for these currents are presented in the second part of the graph.UnitsChoose eitherTimeorAmpere-houras thex-axis for the plot.Battery Dynamics TabBattery response time (s)The response time of the battery (at 95% of the final value).This value represents the voltage dynamics and can be observed when a current step is applied:In this example, a battery response time of 30 secs is used.Extract Battery Parameters From Data SheetsThis section gives an example of detailed parameters extracted from the Panasonic NiMH-HHR650D battery data sheet:From the specification tables, we obtain the rated capacity and the internal resistance. The other detailed parameters are deduced from the Typical Discharge Characteristics plot:ParameterValueRated capacity6.5 AhInternal Resistance2 mNominal Voltage(a)1.18 VRated Capacity6.5 AhMaximum Capacity(b)7 Ah (5.38h * 1.3A)Fully Charged voltage(c)1.39 VNominal Discharge Current(d)1.3 ACapacity Nominal Voltage(a)6.25 AhExponential Voltage(e)1.28 VExponential Capacity(e)1.3 AhThese parameters are approximate and depend on the precision of the points obtained from the discharge curve. A tool, called ScanIt (provided by amsterCHEM,) can be used to extract values from data sheet curves.The parameters obtained from the data sheet are entered in the mask of the Battery block as in the following picture:The discharge curves (the dotted line curves in the following plots) obtained with these parameters are similar to the data sheet curves.Cells in Series and/or in ParallelTo model a series and/or parallel combination of cells based on the parameters of a single cell, the parameter transformation shown in the next figure can be used. TheNb_servariable in mask below corresponds to the number of cells in series, andNb_parcorresponds to the number of cell in parallel:Block Inputs and OutputsmThe Simulink output of the block is a vector containing three signals. You can demultiplex these signals by using the Bus Selector block provided in the Simulink library.SignalDefinitionUnitsSOCThe State-Of-Charge of the battery (between 0 and 100%). The SOC for a fully charged battery is 100% and for an empty battery is 0%. The SOC is calculated as:SOC=100(11QZt0i(t)dt).%CurrentThe Battery currentAVoltageThe Battery voltageVModel ValidationExperimental validation of the model shown a maximum error of 5% (when SOC is between 10% and 100%) for charge (current between 0 and 2C) and discharge (current between 0 and 5C) dynamics.Model Assumptions The internal resistance is supposed constant during the charge and the discharge cycles and doesnt vary with the amplitude of the current. The parameters of the model are deduced from discharge characteristics and assumed to be the same for charging. The capacity of the battery doesnt change with the amplitude of current (No Peukert effect). The model doesnt take the temperature into account. The Self-Discharge of the battery is not represented. It can be represented by adding a large resistance in parallel with the battery terminals. The battery has no memory effect.Limitations The minimum no-load battery voltage is 0 volt and the maximum battery voltage is equal to 2*E0. The minimum capacity of the battery is 0 Ah and the maximum capacity is Qmax.ExampleThepower_batteryexample illustrates a 200 volts, 6.5 Ah NiMH battery connected to a constant load of 50 A. The DC machine is connected in parallel with the load and operates at no load torque. When the State-Of

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论