霍尼韦尔IPM-Vista网络接口模块安装使用说明书_第1页
霍尼韦尔IPM-Vista网络接口模块安装使用说明书_第2页
霍尼韦尔IPM-Vista网络接口模块安装使用说明书_第3页
霍尼韦尔IPM-Vista网络接口模块安装使用说明书_第4页
霍尼韦尔IPM-Vista网络接口模块安装使用说明书_第5页
已阅读5页,还剩27页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Honeywell 网络报警模块(网络报警模块(Vista 系列适用)系列适用) 说明书说明书 IP Module for Vista User Guide 2009 Honeywell International Inc. All rights reserved. Document 800-00559 Rev. D1 Honeywell i 目录目录 1 产品介绍.1 模块功能 .1 PC 端硬件要求.2 2 产品示意图.3 3 安装与连接.5 4 功能操作.6 带电重启 .6 配置.6 软件升级 .6 网络故障保护.6 系统保护 .6 数据回放 .7 虚拟键盘功能.7 恢复出厂值.7 5 常见问题解答.8 6 附录.10 Vista 系列主机配置 .10 VISTA-10P/VISTA-20P 主机配置.10 VISTA-120/VISTA-250BP 主机配置.10 网络报警模块参数设置记录表.12 Honeywell ii Contents 1 Introduction .13 Features.14 PC Requirements .14 2 Interfaces .15 3 Installation and Connection.17 4 Operations.18 Restart.18 Configuration .18 Software Upgrade.18 Network Fault Protection .18 System Protection .18 Data Read-back.19 Visual Panel Keypad .19 Resetting to Factory Default.19 5 FAQ.20 6 Appendix.22 Configurations on the Control Panels of Vista Series.22 Configurations on the VISTA-10P and VISTA-20P Panels .22 Configurations on the VISTA-120 and VISTA-250BP Panels .22 IP Module Configuration Record .24 Honeywell 1 产品介绍产品介绍 网络报警模块(IP 模块)是 Vista 系列报警主机的功能扩展模块,提供通用异步收发器接 口和以太网接口间的数据传送功能,基于 TCP 协议从而提供可靠通信。用户通过 IP 模块用虚 拟键盘设置报警主机,警报发生时,报警主机通过 IP 模块向远程控制中心发送警报信息。 系统具备以下基本功能: 同时具有服务器和客户机功能,TCP/IP 数据栈在其上运行 供电后 IP 模块开始监听并且与远程客户机连接 数据通过网口进入模块并转换成串行数据,然后通过通用异步收发器发送报警主机 从报警主机接收数据,转换成 TCP 数据包发送到本地网络 虚拟主机键盘控制,提供用户更方便的操作和配置 模块功能模块功能 网络报警模块(IP 模块)具备以下功能: 支持 Vista 系列报警主机(必须支持 LRR) 1 产品介绍 8bit 微处理器单元(MCU) 40MIPS 处理速度 64K 闪存,4K 随机读取存储器 10BASE-T PHY 以太网控制器 10/100M 自适应功能,与 10/100BASE-T 网络兼容,具有 10M 速率 MAC 地址出厂编程设定 需要通过 PC 机软件对 IP 模块的 IP 地址和端口进行设定 AES-128bit 加密通信,更安全的网络设备 安装简便易行,兼容性高 供电方式灵活,可由主机直接供电,或由 DC 电源独立供电 工作电压:DC 12V-15V,电流:50mA-75mA 可恢复出厂值 PC端硬件要求端硬件要求 与网络报警模块相连的 PC 端机器需具备以下配置: CPU:PIII 及以上 内存:128M 以上 硬盘:2G 以上 网卡:10M/100M 自适应网卡 操作系统:WINDOWS 2000 及以上(必须关闭系统防火墙) 2 Honeywell 2 产品示意图产品示意图 图图 1 网络报警模块正反面示意图网络报警模块正反面示意图 3 产品示意图 LED 指示灯说明: 编号编号 名称名称 颜色颜色 说明说明 D1 DC 供电指示灯 红色 常亮表示 IP 模块由外部 DC 电源直接供电,否则 不亮。 D2 键盘供电工作指 示灯 红色 常亮表示 IP 模块由主机独立供电,否则不亮。 D3 电源指示灯 绿色 常亮表示 IP 模块的 MCU 部分供电正常,否则不 亮。 D4 工作指示灯 绿色 常亮表示 IP 模块正常工作,否则不亮。 D5 数据回读灯 红色 当系统处于数据回读状态时红灯常亮,否则不亮。 D6 数据传输指示灯 绿色 当串口有数据交互时绿灯常亮,否则不亮。 D7 保护指示灯 红色 当系统处于低电压数据记录状态时红灯常亮,否则 不亮。 跳线配置方法: 1. Vista 主机 JP5、JP6、JP7 跳线均位于 1、2 处; 2. 请不要更改 IP 模块的 JP5、JP6、JP7 的出厂跳线设置,否则可能无法正常工作。 注意注意 接地线请与主机接地端子相连。若不使用接地线,请用电工胶布包裹 线头。 4 Honeywell 3 安装与连接安装与连接 网络报警模块的安装位置如下图所示: 图图 2 网络报警模块安装网络报警模块安装 网络报警模块与主机的连接,请参考下图: 图图 3 网络报警模块与主机连接示意图网络报警模块与主机连接示意图 注意注意 当用外部 DC 供电时,请将上图中的电源(+)不接,其余线与图 中保持一致。图中主机各接线柱的实际标签请参考接入的主机的 说明书。 网络报警模块接入网络时,请使用 VLAN 或者单独路由的方式, 尽量与视频类等大数据量的网络设备隔离。 5 功能操作 4 功能操作功能操作 带电重启带电重启 参看第3页的图 1,当系统工作不稳定时,可长按S1 按钮 3 秒钟,系统自动重启。 配置配置 可通过软件,自动发现 IP 模块,可配置其 IP,网关,上报 IP、端口及模块编号。 软件升级软件升级 10M/100M 自适应功能,可通过网络接口在远程控制下进行 IP 模块的软件版本自动升 级,建议在专业人员指导下进行。 注意注意 当 PC 机网口需要直接连接网络报警模块网口时,请使用网络交叉 线。 网络故障保护网络故障保护 网络通信出现问题或远程服务关闭时,自动存储信息。 系统保护系统保护 内置程序监控功能,外部设有电源监控复位芯片。 6 Honeywell 数据回放数据回放 网络报警是作为传统电话线报警的协作方式,当主机交流电源掉电,且主机使用后备电池 工作至电压低时,网络报警模块将会自动将记录该状态下的报警事件。当需要获取存储的信息 时,参看图 1,长按 S2 按钮 3 秒钟,D5 红灯亮起,触发回放功能。 虚拟键盘功能 虚拟键盘功能 当报警主机与网络模块相连后,可从 PC 端软件反向操作主机,替代部分键盘功能。用户 可根据需要实时察看键盘的当前显示信息。 恢复出厂值恢复出厂值 如果用户需要恢复出厂值,应进行如下操作: 参看图 1,长按 S2 键不放开,再按一下 S1 键并立刻放开,直到 D4 指示灯亮起才可松开 S2 键。 默认出厂值如下表所示: 参数参数 出厂值出厂值 IP 地址 192.168.0.3 子网掩码 255.255.255.0 网关 192.168.0.1 键盘地址 17 密码 000000 序列号 0 IP 模块 LRR 地址 3 IP 地址 192.168.0.2 服务器 端口 3000 注意注意 LRR 为 Lang Rang Radio,具体使用的地址请参考实际接入的 Vista 主机说明书。 7 常见问题解答 5 常见问题解答常见问题解答 问题问题 1:网络报警模块是否能在升级后支持其他不同主机?:网络报警模块是否能在升级后支持其他不同主机? 答:网络报警模块只能基于相同系列主机型号进行升级。为了安全性,请用户在专业指导 下进行升级。 问题问题 2:网络报警模块能否通过:网络报警模块能否通过 IE 浏览器访问?浏览器访问? 答:网络报警模块作为安防产品以太网模块,从安全及可靠性角度考虑,用户可以通过 Honeywell 指定的安装在 PC 端的软件进行访问。使用非授权的软件带来的问题,用户必须自 行承担后果。 问题问题 3:IP 模块的网络报警与传统主机报警相比有什么优势?模块的网络报警与传统主机报警相比有什么优势? 答:传统主机报警由电话线发送,无法直接和以太网络连接,以太网网络报警是下一代的 报警方式,优点众多。并且网络报警模块在传统主机上使用,几乎可以替代键盘功能,操作可 视化,简单化。 问题问题 4:网络报警模块无法正常发送报告了,该怎么处理?:网络报警模块无法正常发送报告了,该怎么处理? 答:当模块无法正常发送报告时,请用户检查本地网络连接是否正常,网络报警模块所在 网络中是否有视频类大数据量网络设备。若不是由网络故障引起的,再检查 IP 模块连线是否 正常。然后检查键盘地址和 LRR 地址是否在主机上配置使能了。如还不能解决问题,请联系 专业人员。 问题问题 5:网络报警模块上磁铁会脱落么?:网络报警模块上磁铁会脱落么? 答:网络报警模块是用磁石固定在主机盒上使用。磁石是用工业级防热,防水固定剂固定 于板上,非常牢固。极偶然情况会出现磁石松动现象,请联系经销商作进一步处理。 问题问题 6:网络报警模块地址是否唯一?:网络报警模块地址是否唯一? 答:唯一。如果网络报警模块的地址重复,可能会引起异常现象。一般情况下,一台 Vista 主机可接多个键盘和一个 LRR。 问题问题 7:远程虚拟键盘操作失败,该怎么处理?:远程虚拟键盘操作失败,该怎么处理? 答:先检查网络连接是否正常;若网络连接正常,再检查网络报警模块的键盘地址是否为 相应 Vista 主机支持的键盘地址(默认情况下 Vista 主机只配置了 16 号键盘),或通过其他键 盘配置主机,使其支持网络报警模块所在地址。IP 模块键盘地址不能与其他键盘地址冲突。 问题问题 8:有时候使用正确的密码还是无法配置网络报警模块,为什么?:有时候使用正确的密码还是无法配置网络报警模块,为什么? 答:出于安全考虑,当配置的密码错误次数超过限度时,网络报警模块将拒绝任何配置, 需手工重启网络报警模块后才可继续尝试配置。 8 Honeywell 问题问题 9:配置密码忘记了怎么办?:配置密码忘记了怎么办? 答:网络报警模块不允许查询密码,因此密码需要妥善保管和记录。密码忘记后,只能通 过恢复网络报警模块的出厂值再重新配置。 问题问题 10: 如何修改网络报警模块的配置?如何修改网络报警模块的配置? 答:一般情况下,可以通过 UDP 和 TCP 两种方式修改。采用 UDP 时,需要保证配置 PC 主机和网络报警模块在同一个子网内。由于 UDP 是采用广播形式配置,所以有时候会有超 时现象,等待两分钟左右,如果没有响应,可尝试重新搜索或配置。采用 TCP 时,需要将网 络报警模块与 PC 连上后配置。 建议可采用如下步骤: 1. 恢复网络报警模块的默认出厂值。 2. 将 PC 主机设置为 192.168.0.2, 子网掩码为 255.255.255.0。 3. 等待网络报警模块连上 PC 之后再进行配置,这样搜索和配置会比较快,此时可以用 UDP 搜索配置方式可以修改多个配置,也可以使用某些特定的 TCP 配置修改功能。 问题问题 11: 配置配置 Vista 主机注意事项主机注意事项. 答:需要上报的信息,必须在 Vista 中设置使能;网络报警模块连接 Vista 主机上报报警 信息时,使用的是 ContactID 格式;网络报警模块配置中的键盘地址和 LRR 地址必须和 Vista 保持一致;在配置防区时,请使用防区默认的 ReportCode 值,请参考各主机相关说明。 9 附录 6 附录附录 Vista系列主机配置系列主机配置 网络报警模块接入 Vista 系列主机后,需要对 Vista 主机进行编程设置。以下内容分别以 VISTA-10P、VISTA-20P、VISTA-120 和 VISTA-250BP 主机为例,介绍如何配置主机接通网 络报警模块。其中,VISTA-10P 和 VISTA-20P 主机设置基本相同,VISTA-120 和 VISTA- 250BP 主机设置基本相同。 VISTA-10P/VISTA-20P主机配置主机配置 主机:输入安装员码+ 8+0+0可进入编程模式,按*97 恢复默认出厂设置。默认安装 员码为 4112。 网络报警模块:使用默认地址配置,即键盘地址使用 17,LRR 地址使用 03。 1. 连接主机 连线时,请将网络报警模块接至键盘口。对应表格如下: VISTA-10P/VISTA-20P 网络报警模块网络报警模块 键盘键盘 接线柱 4 GND 黑线(Blk) 接线柱 5 POWER+ 红线(Red) 接线柱 6 DATAOUT 绿线(Grn) 接线柱 7 DATAIN 黄线(Yel) 2. 配置主机 1) 输入安装员码+8+0+0进入编程模式。 2) *29 设置为 1。 3) *43 输入帐号。 4) *48 输入 77。 5) *50 设置为 0 6) *54、*55、*59、*70 设置为 1。 7) *60、*61、*62、*63、*65、*66、*68、*71、*72、*73、*74 均设置为 11。 8) *93 设置为 0。 9) *181 设置为 1(中国适用)。 10) *190 设置为 10。 VISTA-120/VISTA-250BP主机配置主机配置 主机:输入安装员码+ 8+0+0+0可进入编程模式,按*97 恢复默认出厂设置。默认 安装员码为 4140。 10 Honeywell 网络报警模块:使用默认地址配置,即键盘地址使用 17,LRR 地址使用 03。 1. 连接主机 连线时,请将网络报警模块接至键盘口。对应表格如下: VISTA-120/VISTA-250BP IPM-Vista 键盘键盘 接线柱 7 GND 黑线(Blk) 接线柱 6 POWER+ 红线(Red) 接线柱 8 DATAOUT 绿线(Grn) 接线柱 9 DATAIN 黄线(Yel) 2. 配置主机 1) 输入安装员码+8+0+0+0进入编程模式。 2) 输入*93,进入设备编程菜单(DEVICE PROG): 17 号地址设置为 01 类型(ALPHA CONSOLE) 3 号地址设置为 06 类型(LR RADIO MODULE) 3) 输入*93,进入报告码设置菜单(REPORT CODE PROG)。在 RSTR、SUPV. CODE、SYSTEM GROUP #1、SYSTEM GROUP #2、SYSTEM GROUP #3、 SYSTEM GROUP #4 菜单中,通过设置 01 来使能相关报告。 常见的报告包含报警恢复(Alarm Restore)、防区故障(Trouble)、故障恢复 (Trouble Restore)、旁路(Bypass)、旁路恢复(Bypass Restore)、布防 (Close)、撤防(Open)、电池电压低(Low Battery)、电池电压恢复(Low Battery Restore)、AC 掉电(AC Loss)、AC 恢复(AC Restore)、上电 (Power)、取消(CANCEL)、编程被改动(Program Tamper)等。 4) *23 设置为 1。 5) *32 输入帐号。 6) *39 输入 1。这样使用安装员码进行布撤防时,网络报警模块就会发送报告。如使用 默认密码 1234 是没有布撤防报告权限的,所以不会有布撤防报告产生。 7) *56 设置为 11。 8) *57、*58、*79、*80 设置为 1。 9) *84 设置为 00。 通过以上设置,用户可以通过网络报警模块发送相关报告。如果为 VISTA-120/VISTA- 250BP 设置了子系统,则需要在各子系统中对上述编程地址做同样设置。 11 附录 12 网络报警模块参数设置记录表网络报警模块参数设置记录表 (以下内容请安装人员填写,并交与用户妥善保管。) 客户: 地址: 安装商: 日期: 连接主机型号: 联系电话: 参数参数 设定值设定值 IP 地址 _._._._ 子网掩码 _._._._ 网关 _._._._ 键盘地址 _ 序列号 _ 网络报警模块 LRR 地址 _ 服务器 IP 地址 _._._._ 网络报警模块配 置密码 _ 网络报警模块 MAC 地址(12 位) _-_-_-_-_-_ Honeywell 1 Introduction IP module is designed for extending function of Vista control panels, enabling reliable data transmission based on TCP protocol between the universal asynchronous transceiver and the Ethernet. User can configure the control panel by the “visual keypad” function of the IP module, and the control panel sends alarm information to the remote center by IP module. Figure 1-1 System Architecture The system has the following features: Server/Client architecture, running TCP/IP IP module starts monitoring and communication with the remote alarm center when power-on. IP module receives data via the network port, converts it to serial data and then sends it to the control panel by universal asynchronous transceiver. IP module receives data from the control panel, converts it to TCP data package and sends it to the local network. More convenient operation and setting by Visual Panel Keypad 13 Introduction Features IP module has the following features: Support Vista control panels (LRR supported) 8bit MCU Processing speed: 40MIPS 64K flash memory, 4K RAM 10BASE-T PHY Ethernet Controller 10/100M self-adapting, 10/100BASE-T compatible, speed: 10Mbps MAC address program settings IP address and port settings of the module by PC software AES-128bit encrypted communication, safer network devices Easy installation and high compatibility Flexible power supply: by Vista control panel or DC Working Voltage: DC 12V-15V Current: 50mA-75mA Reset factory default PC Requirements The following are requirements for the PC machine connected with IP module: CPU: PIII and above Memory: 128M and above Hard disk: 2G and above Network card: 10M/100M self-adapting Operating system: WINDOWS 2000 and above (the system firewall must be disabled) 14 Honeywell 2 Interfaces Refer to the following figure for all interfaces, indicators and buttons on the front side of the module: Figure 2-1 IP Module Front 15 Interfaces LED indicators: No. Indicator Name Color The indicator lights up when D1 DC Power Red The power is supplied by DC. D2 Panel power-on Red The power is supplied by Vista control panel. D3 Power Green The power is normally supplied to MCU of IP module. D4 Working Green IP module is in normal working condition. D5 Data read-back Red The system is running data read-back. D6 Data transferring Green Data transmission is running via the serial port. D7 Protecting Red The system is under low-voltage data recording status. JUMP settings: Set JP5, JP6 and JP7 (Vista) to 1 and 2. Do not change the default setting of JP5, JP6 and JP7, otherwise the module may not work properly. Note GND should be connected to the GND terminal of the control panel. Tape the wire-end with electric insulation tape if GND is not used. Figure 2-2 IP Module Back 16 Honeywell 3 Installation and Connection Refer to the following figure to install the IP module in Vista panel. Figure 3-1 Installing IP Module Refer to the following figure to complete the wire connection between IP module and the panel. Figure 3-2 Connection between IP module and Vista panels Note When the power is supplied by external DC, Power (+) should not be connected. For the actual terminal description, refer to the manual of a certain control panel. Connect the IP module to the network by way of VLAN or special router, and make sure to keep the IP module apart from the mass-data network devices, such as the video devices. Install IP module here 17 Operations 4 Operations Restart If the system is not running properly, press S1 (in Figure 2-1 on page 15) and hold for 3 seconds to restart the system. Configuration By specified software, IP module can be automatically detected and its IP address, gateway, reported IP, port and module number can be configured. Software Upgrade The software of IP module can be automatically upgraded via the network by remote control, with 10M/100M adaptive net card. It is recommended to conduct the upgrade under professional guidance. Note To directly connect the network interface of IP module to that of PC machine (alarm center), please use network crossover cable. Network Fault Protection Information is automatically saved when the network communication error occurs or the remote server is shut down. System Protection Program monitoring function is integrated in the module and a reseat chip of power monitoring is located on the module. 18 Honeywell Data Read-back If AC loss occurs in the panel and the backup battery is low, IP module automatically records all alarm events during the low-battery status. To view the alarm records, press S2 (in Figure 2-1 on page 15) and hold for 3 seconds until D5 lights up to start data read-back. Visual Panel Keypad When the IP module is connected to the control panel, you can operate the control panel using PC software, implementing part of the keypad functions. You can view the real-time information displayed in the keypad if needed. Resetting to Factory Default To reset all values to factory default, press S2 (in Figure 2-1) and hold it. When S2 is pressed, press S1 with one stroke. Continue to hold S2 until D4 lights up. Refer to the following table for factory values: Parameter Factory Default IP Address 192.168.0.3 Subnet Mask 255.255.255.0 Gateway 192.168.0.1 Keypad Address 17 Password 000000 Serial Number 0 IP module LRR Address 3 IP Address 192.168.0.2 Server Port 3000 Note LRR: Lang Rang Radio. For the actual LRR address, refer to the manual of a certain Vista control panel. 19 FAQ 5 FAQ Q1: After upgrade, can the IP module support panels of other series? A: IP module can only be upgraded with the panel of the same series. It is recommended to upgrade the module under professional guidance. Q2: Can the IP module be accessed via the network? A: IP module can be accessed by the software specified by Honeywell installed in PC machine. Warranty is not covered in case of using unauthorized software. Q3: What is the advantage of network alarming with IP module, compared with earlier ones? A: Traditional control panel sends alarm through telephone line, while IP module can directly access to the Ethernet, which is regarded as the next-generation alarming method. When the traditional control panel is used with IP module, “visual keypad” is enabled, implementing almost all functions of the keypad and providing easier operations. Q4: Reports cannot be sent normally. A: Firstly, check whether the local network connection is normally connected, and whether there exist mass-data devices (such as video device) in the network that the IP module is connected to. If there is no problem with the connection, check whether the wiring of IP module is corr

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论