




已阅读5页,还剩3页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
骆驼集团蓄电池销售有限公司骆驼集团蓄电池销售有限公司 CAMEL GROUP BATTERY TRADING CO., LTD NO.4 ZHUIRI ROAD, HI-TECH INDUSTRIAL DEVELOPMENTAREA, XIANGFAN,HUBEI,CHINAPOST CODE:441705 Website:TEL:+86 710 334 4102FAX:+86 710 334 3035 SEALEDSEALED MAINTENANCEMAINTENANCE FREEFREE BATTERYBATTERY MATERIALMATERIAL SAFETYSAFETY DATADATA SHEETSHEET SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Manufacturers name:CAMEL GROUP BATTERYTRADING CO.,LTD Adress: NO.4 ZHUIRI ROAD, HI-TECH INDUSTRIAL DEVELOPMENTAREA, XIANGFAN,HUBEI,CHINA post code:441003Tel:+86 710 334 4102Fax:+86 710 334 3035 SECTION 2 - COMPOSITION/INFORMATION ON INGREDIENTS main technical specification forLow-maintenance Batteries (Without Acid): Battery typeRating valve V Rating capacity Ah Net weight KG CCA A Dimension (MAX) L*W*H*TH(mm) 58827128822640352*175*190*190 C.A.S. 7439-92-1 7440-36-0 7440-38-2 7664-93-9 7440-70-2 7440-31-5 PRINCIPALHAZARDOUSCOMPONEN T(S)(chemical may be contained within an outer casing of aluminum or steel. Case has metal terminals. Lead (internal): Gray, metallic, solid; Brown/grey oxide SECTION 10 - STABILITY AND REACTIVITY StabilityUnstable StableConditions to Avoid High temperatures - cases decompose at 320F. Avoid overcharging and smoking, or sparks near battery surface and rapid overcharge. Incompatibility (Materials to Avoid)Sparks, Open flames, Keep battery case away from strong oxidizers. Hazardous Decomposition ProductsAn explosive hydrogen/oxygen mixture within the battery may occur during charging.Combustion can produce carbon dioxide (CO2) and carbon monoxide (CO).Molten metals produce fumes and/or vapor that may be toxic or respiratory irritants. Hazardous Polymerization May Occur Will Not OccurDo not overcharge SECTION 11 - TOXICOLOGICAL INFORMATION GENERAL: The primary routes of exposure to lead are ingestion or inhalation of dust and fumes. 骆驼集团蓄电池销售有限公司骆驼集团蓄电池销售有限公司 CAMEL GROUP BATTERY TRADING CO., LTD NO.4 ZHUIRI ROAD, HI-TECH INDUSTRIAL DEVELOPMENTAREA, XIANGFAN,HUBEI,CHINAPOST CODE:441705 Website:TEL:+86 710 334 4102FAX:+86 710 334 3035 ACUTE: INGESTION/INHALATION: Exposure to lead and its compounds may cause headache, nausea, vomiting, abdominal spasms, fatigue, sleep disturbances, weight loss, anemia, and pain in the legs, arms and joints.Kidney damage, as well as anemia, can occur from acute exposure. CHRONIC: INHALATION/INGESTION: Prolonged exposure to lead and its compounds may produce many of the symptoms of short-term exposure and may also cause central nervous system damage, gastrointestinal disturbances, anemia, and wrist drop.Symptoms of central nervous system damage include fatigue, headaches, tremors, hypertension, hallucinations, convulsions and delirium.Kidney dysfunction and possible injury has also been associated with chronic lead poisoning. Chronic over-exposure to lead has been implicated as a causative agent for the impairment of male and female reproductive capacity, but there is, at present, no substantiation of the implication.Pregnant women should be protected from excessive exposure. Lead can cross the placental barrier and unborn children may suffer neurological damage or developmental problems due to excessive lead exposure in pregnant women. SECTION 12 - ECOLOGICAL INFORMATION In most surface water and groundwater, lead forms compounds with anions such as hydroxides, carbonates, sulfates, and phosphates and precipitates out of the water column.Lead may occur as sorbed ions or surface coatings on sediment mineral particles or may be carried in colloidal particles in surface water.Most lead is strongly retained in soil, resulting in little mobility.Lead may be immobilized by ion exchange with hydrous oxides or clays or by chelation with humic or fulvic acids in the soil. Lead (when in the dissolved phase) is bioaccumulated by plants and animals, both aquatic and terrestrial. SECTION 13 - DISPOSAL CONSIDERATIONS Waste Disposal Lead-acid batteries are completely recyclable.Return whole scrap batteries to distributor, manufacturer or lead smelter for recycling. MethodsFor information on returning batteries to Concorde for recycling call+86 0710 7617594.For neutralized spills, place residue in acid-resistant containers with sorbent material, sand or earth and dispose of in accordance with local, state and federal regulations for acid and lead compounds. Contact local and/or state environmental officials regarding disposal information. SECTION 14 - TRANSPORT INFORMATION UN DOT PROPER SHIPPING NAME: Batteries, wet, non-spillable electric storage CNA. DOT HAZARD CLASS: 8 U.S. DOT ID NUMBER: UN 2794 U.S. DOT PACKING GROUP: III 骆驼集团蓄电池销售有限公司骆驼集团蓄电池销售有限公司 CAMEL GROUP BATTERY TRADING CO., LTD NO.4 ZHUIRI ROAD, HI-TECH INDUSTRIAL DEVELOPMENTAREA, XIANGFAN,HUBEI,CHINAPOST CODE:441705 Website:TEL:+86 710 334 4102FAX:+86 710 334 3035 U.S. DOT LABEL: Corrosive IMO PROPER SHIPPING NAME: Batteries, wet, filled with acid IMO U.N. CLASS: 8 IMO U.N. NUMBER: UN 2794 IMO LABEL: Corrosive IMO VESSEL STOWAGE: A Ems # - F-A, S-B IATA PROPER SHIPPING NAME: Batteries, wet, filled with acid IATA U.N. CLASS: 8 IATA U.N. NUMBER: UN 2794 IATA LABEL: Corrosive ERG Code: 8L SECTION 15 - REGULATORY INFORMATION U.S. Hazardous Under Hazard Communication Standard:Lead - YES Antimony - YESArsenic - YES Ingredients Listed on TSCA Inventory:YES CERCLA Section 304 Hazardous Substances:Lead YESRQ: NA* Antimony YESRQ: 1000 pounds RQ: 5000 pounds Arsenic YESRQ: 1 pound *Reporting not required when diameter of the pieces of solid metal released is equal to or exceeds 100 micrometers. EPCRA Section 302 Extremely Hazardous Substance: EPCRA Section 313 Toxic Release Inventory:Lead - CAS NO: 7439-92-1 Antimony - CAS NO: 7440-36-0Arsenic - CAS NO: 7440-38-2 SECTION 16 - OTHER INFORMATION All information, recommendations, and suggestions in this MSDS, concerning our products are based on tests and data believed to be reliable, it cannot be guaranteed. Since the actual use by others is beyond our control it is the users responsibility to determine the safety, toxicity and suitability for their own use of the product described herein. STANDARD: GB12268-2005 EQUALTO IMDG Code2004,第3204套修正案) THE INFORMATION ABOVE IS BELIEVED TO BE ACCURATE AND REPRESENTS THE BEST INFORMATION CURRENTLY AVAILABLE TO US. HOWEVER, CONCORDE MAKES NO WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, WITH RESPECT TO SUCH INFORMATION, AND WE ASSUME NO LIABILITY RESULTING FROM ITS USE.USERS SHOULD MAKE THEIR OWN INVESTIGATIONS TO DETERMINE THE SUITABILITY OF THE INFORMATION FOR THEIR PARTICULAR PURPOSES.ALTHOUGH REASONABLE PRECAUTIONS HAVE BEEN TAKEN IN THE PREPARATION OF THE DATA CONTAINED HEREIN, IT IS OFFERED SOLELY FOR YOUR INFORMATION, CONSIDERATION AND INVESTIGATION.THIS MATERIAL SAFETY DATA SHEET PROVIDES GUIDELINES FOR THE SAFE HANDLING AND USE OF THIS PRODUCT; IT DOES NOT AND CANNOT ADVISE ON ALL POSSIBLE SITUATIONS, THEREFORE, YOUR SPECIFIC USE OF THIS PRODUCT SHOULD BE EVALUATED TO DETERMINE IF ADDITIONAL PRECAUTIONS ARE REQUIRED. 骆驼集团蓄电池销售有限公司骆驼集团蓄电池销售有限公司 CAMEL GROUP BATTERY TRADING CO., LTD NO.4 ZHUIRI ROAD, HI-TECH INDUSTRIAL DEVELOPMENTAREA, XIANGFAN,HUBEI,CHINAPOST CODE:441705 Website:TEL:+86 710 334 4102FAX:+86 710 334 3035 MULTIMODAL DANGEROUS GOODS FORM This form may be used as a dangerous goods declaration as it meets the requirements of SOLAS 74, chapter VII, regulation 5; MARPOL 73/78,Annex III, regulation 4 and section 9 of the General Introduction to the IMDG Code. 1.Shipper CAMEL GROUP BATTERY TRADING CO., LTD. NO.4ZHUIRIROAD,HI-TECHINDUSTRIAL DEVELOPMENT AREA, XIANGFAN,HUBEI,CHINA , 441003 2. Transport document number 951448570 3. Pageofpages 1/1 4. Shippers reference 5. Freight forwarders reference 6.Consignee7. Carrier (to be completed by the carrier) MAERSK LINE Chloride Exide Botswana Pty. Ltd PLOT 20715, WESTERN BYPASS, INDUSTRIAL ESTATE,GABORONE, BOTSWANA P O BOX 149 T: 00267 3959990 F: 00267 3959992 SHIPPERS DECLARATION I hereby declare that the contents of this consignment are fully and accurately described below by the proper shipping name, and are classified, packaged, marked and labeled/placarded and are in all respects in proper condition for transport according to the applicable international and national government regulations. 8. This shipment is within the limitations prescribed for: (Delete non-applicable) 9.Additional handling information Emergency contact person: MR. YANG(紧急联系人紧急联系人) Emergency contact telephone :86-710-3344102(紧急联系人电话) EMSF-AS-B(紧急处理方式缩写)(紧急处理方式缩写) 10. Vessel/flight no. and date11. Port/place of loading WUHAN,CHINA 12. Port/place of discharge DURBAN 13. Destination GABORONE,BOTSWA NA 14. Shipment informationNumber and kind of packages; description of goods( *seebottom) gross weightnet weight 28PLTS, UNIT LOAD, PALLET BOX, CRATE2576124781 Proper shipping name: BATTERIES, WET, FILLED WITH ACID electric storage Technical name (if have): NO. Imo class (sub risk):8 Un no.:2794 Package group:III Flash point (if have):NO Marine pollutant (if have) :NO EMS :F-A,S-B Package quantity (Outer package) : 28PLTS, UNIT LOAD, PALLET BOX, CRATE Package quantity (Inter package) : NO 骆驼集团蓄电池销售有限公司骆驼集团蓄电池销售有限公司 CAMEL GROUP BATTERY TRADING CO., LTD NO.4 ZHUIRI ROAD, HI-TECH INDUSTRIAL DEVELOPMENTAREA, XIANGFAN,HUBEI,CHINAPOST CODE:441705 Website:TEL:+86 710 334 4102FAX:+86 710 334 3035 15.Containernumber. MSKU5863674 16. Seal number(s)17.ContainerSize & type 1X20GP 18. Tare mass (kg) KGS CONTAINER/VEHICLE PACKING CERTIFICATE I hereby declare that the goods described above have been packed/loaded into the container/vehicle identified above in accordance with the applicable
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 丘陵地区灌溉排涝系统改造技术方案
- 高速覆铜板生产项目施工方案
- 2025年质量管理体系内审员资质测试题及答案
- 2025年安全工程师考试试题及答案
- 房屋建筑综合管线布设方案
- 2025年大数据分析专业考研试卷及答案
- 建筑通风系统安装方案
- 社区口袋公园的设计与规划策略分析
- 会计稳健性与企业税收负担的关系研究
- 吨油营销支出提升方案
- 客户转让合同协议书范本
- 光伏发电工程竣工最终验收报告
- 发改价格〔2007〕670号建设工程监理与相关服务收费标准
- 2025年小学生科普知识竞赛练习题库及答案(200题)
- 传媒行业创新案例小红书
- 《美妆类电商产品销量影响因素实证研究13000字(论文)》
- T-JSQX 0016-2024 无人驾驶配送装备通.用技术要求
- 科技前沿下的生物医药研发实验室创新研究
- 《铝及铝合金》课件
- 2025年摩托车用锁行业深度研究分析报告
- 临床问诊技巧及病历书写要求(临床诊断课件)
评论
0/150
提交评论