已阅读5页,还剩18页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
HardwareAdministration,:,4,AutomatedUptimeLayerfortheVMwareESXiOperatingSystem,DesignedforUptimeAssuranceConstantlymonitorsthesystemandrespondstohardwareeventsAutomaticallymaintainsMTBFstatisticsInterfaceswiththeStratusActiveServiceNetwork(ASN)Providescommand-lineutilitiesformanagingthesystemcomponents,2,HardwarePaths,Numericvaluesthatidentifyspecificcomponents.DeviceIDsarelistedformostdevices.DeviceIDsareseparatedbyslashes(/)Examples:10/40/111/7PCIeaddressesarelistedforsomedevicesPCIeaddressesareseparatedbycolons(:)anddots(.)BusNumber:Device.FunctionExamples:06:00.07b:00.0Networkinterfacesareassignednames,suchasvmnic110600,byAutomatedUptimeLayer.,3,DeviceIDs,ProvideidentificationforhardwarecomponentsSpecifyaddressesofhardwarecomponentsConsistofnumericalstringsofhardwareaddresses,startingfrommainbus,4,ftServerDeviceIDs(Examples),5,UptimeAssuranceDeviceStates,Online,ERROR,Missing,Offline,6,PATHVariable,Theftsmaintutilityisinthe/opt/ft/bindirectory.TheVTMConfigandASNConfigcommandsareinthe/opt/ft/sbindirectory.Addthe/opt/ft/binand/opt/ft/sbindirectorypathstothePATHvariable,asfollows:#exportPATH=$PATH:/opt/ft/bin:/opt/ft/sbin,7,TheftsmaintCommand,/opt/ft/bin/ftsmaintUseftsmainttoexamineandcontrolfault-tolerantsettingsofhardwarecomponentsonasystem.Toviewthemanualpage:#manftsmaint,8,ftsmaintSyntax,Synopsis:/opt/ft/bin/ftsmaintcmdpathSomeftsmaintCommands:lspathDisplaysstatusandlonglistofthedevicebringUppathBringsthedeviceintoservicebringDownpathTakesthedeviceoutofservicerunDiagpathPerformsdiagnosticsonthedeviceacSwitchpathSwitchestheactivecompatibilitytoI/OelementatpathmemCheckTeststheintegrityofsystemmemorySeetheStratusftServerSystemAdministratorsGuideforVMwarevSphere(R002E)fordescriptionsofmorecommands.,9,ftsmaintExamples,Tolistdetailsaboutthedeviceatthespecifichardwarepath(oralldevicesifpathisomitted;seethefollowingslides):/opt/ft/bin/ftsmaintlspathTodisplaydetailedstatusofaspecificdevice:ftsmaintls10Toremoveadevicefromservice:ftsmaintbringDown11/40/2Tobringadeviceintoservice:ftsmaintbringUp11/40/2ToswitchActiveCompatibility:ftsmaintacSwitch,10,ftsmaintls,11,H/WPathDescriptionStateOPStateFRevFct=0CombinedCPU/IOONLINEDUPLEX*00/1DIMMONLINEONLINE-0/2DIMMONLINEONLINE-0/3DIMMONLINEONLINE-0/4DIMMONLINEONLINE-0/5DIMMONLINEONLINE-0/6DIMMONLINEONLINE-0/7DIMMONLINEONLINE-0/8DIMMONLINEONLINE-0/9DIMMONLINEONLINE-0/10DIMMONLINEONLINE-0/11DIMMONLINEONLINE-0/12DIMMONLINEONLINE-0/13DIMMONLINEONLINE-0/14DIMMONLINEONLINE-0/15DIMMONLINEONLINE-0/16DIMMONLINEONLINE-0/21Intel(R)Xeon(R)CPUE5-260301.80GHzONLINEONLINE-0/22Intel(R)Xeon(R)CPUE5-260301.80GHzONLINEONLINE-0/130BaseboardTemp#0Sensor-NORMAL-0/140BaseboardFan1#0Sensor-NORMAL-0/141BaseboardFan2#0Sensor-NORMAL-0/142BaseboardFan3#0Sensor-NORMAL-0/143BaseboardFan4#0Sensor-NORMAL-0/144BaseboardFan5#0Sensor-NORMAL-,ftsmaintls(Continued),12,1CombinedCPU/IOONLINEDUPLEX*01/1DIMMONLINEONLINE-1/2DIMMONLINEONLINE-1/3DIMMONLINEONLINE-1/4DIMMONLINEONLINE-1/5DIMMONLINEONLINE-1/6DIMMONLINEONLINE-1/7DIMMONLINEONLINE-1/8DIMMONLINEONLINE-1/9DIMMONLINEONLINE-1/10DIMMONLINEONLINE-1/11DIMMONLINEONLINE-1/12DIMMONLINEONLINE-1/13DIMMONLINEONLINE-1/14DIMMONLINEONLINE-1/15DIMMONLINEONLINE-1/16DIMMONLINEONLINE-1/21Intel(R)Xeon(R)CPUE5-260301.80GHzONLINEONLINE-1/22Intel(R)Xeon(R)CPUE5-260301.80GHzONLINEONLINE-1/130BaseboardTemp#1Sensor-NORMAL-1/140BaseboardFan1#1Sensor-NORMAL-1/141BaseboardFan2#1Sensor-NORMAL-1/142BaseboardFan3#1Sensor-NORMAL-1/143BaseboardFan4#1Sensor-NORMAL-1/144BaseboardFan5#1Sensor-NORMAL-,ftsmaintls(Continued),13,10CombinedCPU/IOONLINEDUPLEX-010/1NetworkCtlrONLINEDUPLEX-00c:00.0Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth100100NetworkInterfaceONLINEDUPLEX-0c:00.1Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth100101NetworkInterfaceONLINEDUPLEX-10/2-MISSINGEMPTY-10/3-MISSINGEMPTY-10/4-MISSINGEMPTY-10/5MassStorageCtlrONLINEDUPLEX-00b:00.0SerialAttachedSCSIcontroller:LSILogicONLINEDUPLEX-10/6NetworkCtlrONLINEDUPLEX-007:00.0Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth100600NetworkInterfaceONLINEDUPLEX-07:00.1Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth100601NetworkInterfaceONLINEDUPLEX-10/7DisplayCtlrONLINEDUPLEX-00a:00.0VGAcompatiblecontroller:MatroxElectroONLINEDUPLEX-10/8SerialBusCtlrsONLINEONLINE-02c:00.0USBController:IntelCorporationC600/X7ONLINEONLINE-2c:00.1USBController:IntelCorporationC600/X7ONLINEONLINE-10/10-ONLINEONLINE-010/11-ONLINEONLINE-0,ftsmaintls(Continued),14,10/12NetworkCtlrONLINEDUPLEX-07d:00.0Ethernetcontroller:IntelCorporationEtONLINEONLINE-eth101200NetworkInterfaceONLINEDUPLEX-7d:00.1Ethernetcontroller:IntelCorporationEtBROKENBROKEN-eth101201NetworkInterfaceBROKENBROKEN-10/40InternalDiskEnclosure-10/40/1DiskDriveONLINEDUPLEX0102010/40/2DiskDriveONLINEDUPLEX0004010/40/3DiskDriveONLINEDUPLEX0102010/40/4DiskDriveONLINEDUPLEX0102010/40/5DiskDriveONLINEDUPLEX0004010/40/6DiskDriveONLINEDUPLEX0004010/40/7DiskDriveONLINEDUPLEX0004010/40/8DiskDriveONLINEDUPLEX0004010/702xPCI-E2(X4)RiserCard-10/120BaseboardManagementCtlrONLINEDUPLEX*-,ftsmaintls(Continued),15,11CombinedCPU/IOONLINEDUPLEX-011/1NetworkCtlrONLINEDUPLEX-046:00.0Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth110100NetworkInterfaceONLINEDUPLEX-46:00.1Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth110101NetworkInterfaceONLINEDUPLEX-11/2-MISSINGEMPTY-11/3-MISSINGEMPTY-11/4-MISSINGEMPTY-11/5MassStorageCtlrONLINEDUPLEX-045:00.0SerialAttachedSCSIcontroller:LSILogicONLINEDUPLEX-11/6NetworkCtlrONLINEDUPLEX-041:00.0Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth110600NetworkInterfaceONLINEDUPLEX-41:00.1Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth110601NetworkInterfaceONLINEDUPLEX-11/7DisplayCtlrONLINEDUPLEX-044:00.0VGAcompatiblecontroller:MatroxElectroONLINEDUPLEX-11/8SerialBusCtlrsONLINEONLINE-066:00.0USBController:IntelCorporationC600/X7ONLINEONLINE-66:00.1USBController:IntelCorporationC600/X7ONLINEONLINE-11/10-ONLINEONLINE-011/11-ONLINEONLINE-0,ftsmaintls(Continued),16,11/12NetworkCtlrONLINEDUPLEX-0b7:00.0Ethernetcontroller:IntelCorporationEtONLINEONLINE-eth111200NetworkInterfaceONLINEDUPLEX-b7:00.1Ethernetcontroller:IntelCorporationEtBROKENBROKEN-eth111201NetworkInterfaceBROKENBROKEN-11/40InternalDiskEnclosure-11/40/1DiskDriveONLINEDUPLEX0102011/40/2DiskDriveONLINEDUPLEX0004011/40/3DiskDriveONLINEDUPLEX0102011/40/4DiskDriveONLINEDUPLEX0102011/40/5DiskDriveONLINEDUPLEX0004011/40/6DiskDriveONLINEDUPLEX0004011/40/7DiskDriveONLINEDUPLEX0004011/40/8DiskDriveONLINEDUPLEX0004011/702xPCI-E2(X4)RiserCard-11/120BaseboardManagementCtlrONLINEDUPLEX*-IOEnclosure11istheActiveCompatibilityNode.ThisisanftServer4700system,P-PackageP4700-2S,Serial#2200008.*UselsLongtoseethisvalue.,TwoTypesofftServerFirmware,Twofirmwaretypes:BMCandBIOSTofindlatestBMCimagefileontheAutomatedUptimeLayerdistributionDVD:/mnt/cdrom/firmware/bmc/2700_4700_6400/062-01210bmc_Bnn.nnRnn.nnPnn.nnSnn.nn.bhxOntheftSysMaintenanceAppliance:/opt/ft/firmware/bmc/2700_4700_6400/062-01210bmc_Bnn.nnRnn.nnPnn.nnSnn.nn.bhxTofindlatestBIOSimagefileontheAutomatedUptimeLayerdistributionDVD:/mnt/cdrom/firmware/bios/2700_4700_6400/062-01210biosn.n.n.romOntheftSysMaintenanceAppliance:/opt/ft/firmware/bios/2700_4700_6400/062-01210biosn.n.n.rom,17,ftServerFirmware(Continued),UpdateBMCfirmwarebeforeupdatingtheBIOSfirmware.VTMfirmwareisupdatedwhenBMCfirmwareisupdated.VTMfeaturesarediscussedinChapter9.DonotinterruptaBIOSorBMCfirmwareupdatewhileafirmwareburnisinprogress.InterruptingpowertoaCPU-I/OenclosureduringaburncanresultinEEPROMdamage.CorrectingthisproblemmayrequirethatyouobtainareplacementCPU-I/Oenclosure.,18,TwoWaystoTransferFilesforFirmwareUpdate,FromamanagementPCviaSCPtoftSysManagementAppliance:OnamanagementPC,useSCPtocopyfilestotheapplianceasroot.LogontotheappliancetoaccesstheFWfiles.UsingvSphereClient:ConnectaCD,DVD,ISOfileorUSBdevicetotheappliance.FollowcorrectprocedureinStratusAutomatedUptimeLayerforVMwarevSphere-basedftServerSystems:InstallationandConfiguration(R004E)totransferthefiles.USBprocedurediffersfromtheprocedurefortheothermedia.Afterfiletransfer,unmountthemediaintheappliancebeforedisconnectingvSphereClient.,19,UpdatingBMCFirmware,TransferBMCfiletotheftSysManagementApplianceusingSCP,orbyusingvSphereClienttomounttheAutomatedUptimeLayerDVDintotheappliance.Asroot,copyBMCimageto/opt/ft/firmware/bmc.BurnthefirmwaretobothBMCswith/opt/ft/bin/ftsmaintburnBmcs.,20,UpdatingBIOSFirmware,TransferBIOSimagetotheftSysManagementApplianceusingSCP,orbyusingvSphereClienttomountAutomatedUptimeLayerDVDintotheappl
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 《JBT 2571-2013电动工具 产品包装技术条件》专题研究报告
- (2026年)急性心力衰竭患者护理课件
- 农村电商物流师能力水平认证试卷及答案
- 医学生理化学类:细胞色素课件
- 导游服务意识问卷调查试题冲刺卷
- 2025年出租车司机安全防范评价试题冲刺卷
- 天津市滨海新区大港油田一中2026年高三下学期四月调考物理试题含解析
- 2026年云南省丽江市重点中学高三3月联考(物理试题文)试题含解析
- 2025河南开封市万岁山游览区有限公司招聘笔试历年备考题库附带答案详解
- 2026届湖南省湖南师大附中高考语文试题命题比赛模拟试卷(22)含解析
- 2026年山东胜利职业学院单招综合素质考试题库附答案解析
- 销售岗位合同范本与注意事项
- 不合格人员再培训制度
- 《世说新语》启发教学法示范教案
- 深圳海关公务员考试试题及答案
- 烫熨疗法课件
- 四川省2025年高职单招职业技能综合测试(中职类)计算机类试卷(含答案解析)
- 2025年采制样工岗位培训与考试题库采及答案
- 中国微生物肥项目创业投资方案
- 部队班组搜索战术课件
- 山东省潍坊市2025年中考数学真题附真题答案
评论
0/150
提交评论