




已阅读5页,还剩14页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
BSEN5008512005电气装置用电缆导管和电缆管道系统BSENBRITISHSTANDARD5008512005CABLETRUNKINGSYSTEMSANDCABLEDUCTINGSYSTEMSFORELECTRICALINSTALLATIONSPART1GENERALREQUIREMENTSTHEEUROPEANSTANDARDEN5008512005HASTHESTATUSOFABRITISHSTANDARDICS2912010/0LICENSEDCOPYINSTITUTEOFTECHNOLOGYTALLAGHT,INSTITUTEOFTECHNOLOGY,SUNOCT08001526BST2006,UNCONTROLLEDCOPY,CBSIBSEN5008512005NATIONALFOREWORDTHISBRITISHSTANDARDISTHEOFFICIALENGLISHLANGUAGEVERSIONOFEN5008512005ITSUPERSEDESBSEN5008511999WHICHWILLREMAINCURRENTUNTILEN5008523ISALIGNEDWITHTHISEDITIONOFEN500851THEUKPARTICIPATIONINITSPREPARATIONWASENTRUSTEDTOTECHNICALCOMMITTEEPEL/213,CABLEMANAGEMENT,WHICHHASTHERESPONSIBILITYTOAIDENQUIRERSTOUNDERSTANDTHETEXTPRESENTTOTHERESPONSIBLEINTERNATIONAL/EUROPEANCOMMITTEEANYENQUIRIESONTHEINTERPRETATION,ORPROPOSALSFORCHANGE,ANDKEEPUKINTERESTSINFORMEDMONITORRELATEDINTERNATIONALANDEUROPEANDEVELOPMENTSANDPROMULGATETHEMINTHEUKALISTOFORGANIZATIONSREPRESENTEDONTHISCOMMITTEECANBEOBTAINEDONREQUESTTOITSSECRETARYCROSSREFERENCESTHEBRITISHSTANDARDSWHICHIMPLEMENTINTERNATIONALOREUROPEANPUBLICATIONSREFERREDTOINTHISDOCUMENTMAYBEFOUNDINTHEBSICATALOGUEUNDERTHESECTIONENTITLED“INTERNATIONALSTANDARDSCORRESPONDENCEINDEX”,ORBYUSINGTHE“SEARCH”FACILITYOFTHEBSIELECTRONICCATALOGUEOROFBRITISHSTANDARDSONLINETHISPUBLICATIONDOESNOTPURPORTTOINCLUDEALLTHENECESSARYPROVISIONSOFACONTRACTUSERSARERESPONSIBLEFORITSCORRECTAPPLICATIONCOMPLIANCEWITHABRITISHSTANDARDDOESNOTOFITSELFCONFERIMMUNITYFROMLEGALOBLIGATIONSSUMMARYOFPAGESTHISDOCUMENTCOMPRISESAFRONTCOVER,ANINSIDEFRONTCOVER,THEENTITLEPAGE,PAGES2TO43ANDABACKCOVERTHEBSICOPYRIGHTNOTICEDISPLAYEDINTHISDOCUMENTINDICATESWHENTHEDOCUMENTWASLASTISSUEDTHISBRITISHSTANDARDWASAMENDMENTSISSUEDSINCEPUBLICATIONPUBLISHEDUNDERTHEAUTHORITYOFTHESTANDARDSPOLICYANDAMDNODATECOMMENTSSTRATEGYCOMMITTEEON14NOVEMBER2005BSI14NOVEMBER2005ISBN0580467651/LICENSEDCOPYINSTITUTEOFTECHNOLOGYTALLAGHT,INSTITUTEOFTECHNOLOGY,SUNOCT08001526BST2006,UNCONTROLLEDCOPY,CBSIEUROPEANSTANDARDEN500851NORMEEUROPENNEEUROPISCHENORMAUGUST2005ICS2912010SUPERSEDESEN5008511997A11998ENGLISHVERSIONCABLETRUNKINGSYSTEMSANDCABLEDUCTINGSYSTEMSFORELECTRICALINSTALLATIONSPART1GENERALREQUIREMENTSSYSTMESDEGOULOTTESETDECONDUITSELEKTROINSTALLATIONSKANALSYSTEMEPROFILSPOURINSTALLATIONSLECTRIQUESFRELEKTRISCHEINSTALLATIONENPARTIE1RGLESGNRALESTEIL1ALLGEMEINEANFORDERUNGENTHISEUROPEANSTANDARDWASAPPROVEDBYCENELECON20050401CENELECMEMBERSAREBOUNDTOCOMPLYWITHTHECEN/CENELECINTERNALREGULATIONSWHICHSTIPULATETHECONDITIONSFORGIVINGTHISEUROPEANSTANDARDTHESTATUSOFANATIONALSTANDARDWITHOUTANYALTERATIONUPTODATELISTSANDBIBLIOGRAPHICALREFERENCESCONCERNINGSUCHNATIONALSTANDARDSMAYBEOBTAINEDONAPPLICATIONTOTHECENTRALSECRETARIATORTOANYCENELECMEMBERTHISEUROPEANSTANDARDEXISTSINTHREEOFFICIALVERSIONSENGLISH,FRENCH,GERMANAVERSIONINANYOTHERLANGUAGEMADEBYTRANSLATIONUNDERTHERESPONSIBILITYOFACENELECMEMBERINTOITSOWNLANGUAGEANDNOTIFIEDTOTHECENTRALSECRETARIATHASTHESAMESTATUSASTHEOFFICIALVERSIONSCENELECMEMBERSARETHENATIONALELECTROTECHNICALCOMMITTEESOFAUSTRIA,BELGIUM,CYPRUS,CZECHREPUBLIC,DENMARK,ESTONIA,FINLAND,FRANCE,GERMANY,GREECE,HUNGARY,ICELAND,IRELAND,ITALY,LATVIA,LITHUANIA,LUXEMBOURG,MALTA,NETHERLANDS,NORWAY,POLAND,PORTUGAL,SLOVAKIA,SLOVENIA,SPAIN,SWEDEN,SWITZERLANDANDUNITEDKINGDOMCENELECEUROPEANCOMMITTEEFORELECTROTECHNICALSTANDARDIZATIONCOMITEUROPENDENORMALISATIONELECTROTECHNIQUEEUROPISCHESKOMITEEFRELEKTROTECHNISCHENORMUNGCENTRALSECRETARIATRUEDESTASSART35,B1050BRUSSELS2005CENELECALLRIGHTSOFEXPLOITATIONINANYFORMANDBYANYMEANSRESERVEDWORLDWIDEFORCENELECMEMBERSREFNOEN5008512005E/LICENSEDCOPYINSTITUTEOFTECHNOLOGYTALLAGHT,INSTITUTEOFTECHNOLOGY,SUNOCT08001526BST2006,UNCONTROLLEDCOPY,CBSIEN50085120052FOREWORDTHISEUROPEANSTANDARDWASPREPAREDBYTHETECHNICALCOMMITTEECENELECTC213,CABLEMANAGEMENTTHETEXTOFTHEDRAFTWASSUBMITTEDTOTHEFORMALVOTEANDWASAPPROVEDBYCENELECASEN500851ON20050401THISEUROPEANSTANDARDSUPERSEDESEN5008511997A11998NOTEEN5008511997A11998WILLREMAINVALIDASLONGASPART23HASNOTBEENALIGNEDWITHTHESECONDEDITIONOFPART1THEFOLLOWINGDATESWEREFIXEDLATESTDATEBYWHICHTHEENHASTOBEIMPLEMENTEDATNATIONALLEVELBYPUBLICATIONOFANIDENTICALDOP20060401NATIONALSTANDARDORBYENDORSEMENTLATESTDATEBYWHICHTHENATIONALSTANDARDSCONFLICTINGDOWWITHTHEENHAVETOBEWITHDRAWNOPEN,DEPENDINGONREVISIONOFPART23,TOBEALIGNEDWITHTHISPART1THISSTANDARDISASYSTEMSTANDARDFORCABLEMANAGEMENTPRODUCTSUSEDFORELECTROTECHNICALPURPOSESITRELATESTOTHECOUNCILDIRECTIVESONTHEAPPROXIMATIONOFLAWS,REGULATIONSANDADMINISTRATIVEPROVISIONSOFTHEMEMBERSTATESRELATINGTOTHELOWVOLTAGEDIRECTIVE73/23/EECTHROUGHCONSIDERATIONOFTHEESSENTIALREQUIREMENTSOFTHISDIRECTIVETHISSTANDARDISSUPPORTEDBYSEPARATESTANDARDSTOWHICHREFERENCESAREMADE_/LICENSEDCOPYINSTITUTEOFTECHNOLOGYTALLAGHT,INSTITUTEOFTECHNOLOGY,SUNOCT08001526BST2006,UNCONTROLLEDCOPY,CBSI3EN5008512005CONTENTS1SCOPE42NORMATIVEREFERENCES43DEFINITIONS54GENERALREQUIREMENTS85GENERALCONDITIONSFORTESTS96CLASSIFICATION97MARKINGANDDOCUMENTATION128DIMENSIONS139CONSTRUCTION1310MECHANICALPROPERTIES1911ELECTRICALPROPERTIES2212THERMALPROPERTIES2513FIREHAZARD2614EXTERNALINFLUENCES2815ELECTROMAGNETICCOMPATIBILITY29ANNEXAINFORMATIVETYPESOFCABLETRUNKINGSYSTEMSCTSANDCABLEDUCTINGSYSTEMSCDS40ANNEXBINFORMATIVEADEVIATIONS42ANNEXCNORMATIVECTS/CDSIKCODE43FIGURE1TYPESANDAPPLICATIONOFTRUNKINGSYSTEMSCTSANDDUCTINGSYSTEMSCDS30FIGURE2EXAMPLEOFIMPACTTESTAPPARATUS31FIGURE3ARRANGEMENTFORTESTFORRESISTANCETOFLAMEPROPAGATION32FIGURE4ENCLOSUREFORTESTFORRESISTANCETOFLAMEPROPAGATION33FIGURE5BALLPRESSURETESTAPPARATUS34FIGURE6ELECTRICALIMPEDANCETESTSARRANGEMENT36FIGURE7EXAMPLESOFMEMBRANESANDGROMMETS37FIGURE8APPARATUSFORTESTINGTHERESISTANCEOFCABLEANCHORAGETOPULLFORCE38FIGURE9TYPICALAPPARATUSFORTESTINGTHERESISTANCEOFCABLEANCHORAGETOTWISTFORCE39TABLE1MINIMUMSTORAGEANDTRANSPORTTEMPERATURE10TABLE2MINIMUMINSTALLATIONANDAPPLICATIONTEMPERATURE10TABLE3IMUMAPPLICATIONTEMPERATURE10TABLE4TORQUEVALUESFORTHETESTOFSCREWEDCONNECTIONS15TABLE5FORCESANDTORQUESTOBEAPPLIEDTOCABLEANCHORAGE19TABLE6IMPACTTESTVALUES/LICENSEDCOPYINSTITUTEOFTECHNOLOGYTALLAGHT,INSTITUTEOFTECHNOLOGY,SUNOCT08001526BST2006,UNCONTROLLEDCOPY,CBSIEN500851200541SCOPETHISEUROPEANSTANDARDSPECIFIESREQUIREMENTSANDTESTSFORCABLETRUNKINGSYSTEMSCTSANDCABLEDUCTINGSYSTEMSCDSINTENDEDFORTHEACCOMMODATION,ANDWHERENECESSARYFORTHEELECTRICALLYPROTECTIVESEPARATION,OFINSULATEDCONDUCTORS,CABLESANDPOSSIBLYOTHERELECTRICALEQUIPMENTINELECTRICALAND/ORCOMMUNICATIONSYSTEMSINSTALLATIONSTHEIMUMVOLTAGEOFTHESEINSTALLATIONSIS1000VACAND1500VDCTHISSTANDARDDOESNOTAPPLYTOCONDUITSYSTEMS,CABLETRAYSYSTEMS,CABLELADDERSYSTEMS,POWERTRACKSYSTEMSOREQUIPMENTCOVEREDBYOTHERSTANDARDSTHISPART1SHALLBEUSEDINCONJUNCTIONWITHTHERELEVANTPART2FORPARTICULARREQUIREMENTSNOTETHISPART1ISNOTINTENDEDTOBEUSEDBYITSELF2NORMATIVEREFERENCESTHEFOLLOWINGREFERENCEDDOCUMENTSAREINDISPENSABLEFORTHEAPPLICATIONOFTHISDOCUMENTFORDATEDREFERENCES,ONLYTHEEDITIONCITEDAPPLIESFORUNDATEDREFERENCES,THELATESTEDITIONOFTHEREFERENCEDDOCUMENTINCLUDINGANYAMENDMENTSAPPLIESEN2276811993GENERALTOLERANCESPART1TOLERANCESFORLINEARANDANGULARDIMENSIONSWITHOUTINDIVIDUALTOLERANCEINDICATIONSISO276811989EN500852SERIESCABLETRUNKINGSYSTEMSANDCABLEDUCTINGSYSTEMSFORELECTRICALINSTALLATIONSPART2PARTICULARREQUIREMENTSEN501021995DEGREESOFPROTECTIONPROVIDEDBYENCLOSURESFORELECTRICALA11998EQUIPMENTAGAINSTEXTERNALMECHANICALIMPACTSIKCODEEN604231994CONDUITSFORELECTRICALPURPOSESOUTSIDEDIAMETERSOFCONDUITSFORELECTRICALINSTALLATIONSANDTHREADSFORCONDUITSANDFITTINGSIEC604231993,MODIFIEDEN605291991DEGREESOFPROTECTIONPROVIDEDBYENCLOSURESIPCODEIEC605291989EN6069524/11993FIREHAZARDTESTINGPART2TESTMETHODSSECTION4/SHEET11KWNOMINALPREMIXEDTESTFLAMEANDGUIDANCEIEC6069524/11991EN606952112001FIREHAZARDTESTINGPART211GLOWING/HOTWIREBASEDTESTMETHODSGLOWWIREFLAMMABILITYTESTMETHODFORENDPRODUCTSIEC606952112000EN610321998PROTECTIONOFPERSONSANDEQUIPMENTBYENCLOSURESPROBESFORVERIFICATIONIEC610321997HD383S21986CONDUCTORSOFINSULATEDCABLESIEC602281978IEC60228A1982HD3841S11979ELECTRICALINSTALLATIONSOFBUILDINGSIEC6036411972A11976,MODIFIED/LICENSEDCOPYINSTITUTEOFTECHNOLOGYTALLAGHT,INSTITUTEOFTECHNOLOGY,SUNOCT08001526BST2006,UNCONTROLLEDCOPY,CBSI5EN5008512005HD384551S11985PART5SELECTIONANDERECTIONOFELECTRICALEQUIPMENTCHAPTER51COMMONRULESIEC603645511979,MODIFIEDHD384554S11988CHAPTER54EARTHINGARRANGEMENTSANDPROTECTIVECONDUCTORSIEC603645541980,MODIFIEDIEC600508262004INTERNATIONALELECTROTECHNICALVOCABULARYIEVPART826ELECTRICALINSTALLATIONSDATABASEIEC60417GRAPHICALSYMBOLSFORUSEONEQUIPMENT3DEFINITIONSFORTHEPURPOSEOFTHISEUROPEANSTANDARDTHEFOLLOWINGDEFINITIONSAPPLY31CABLETRUNKINGSYSTEMCTSASSEMBLYCOMPRISINGATRUNKINGLENGTHANDPOSSIBLYOTHERSYSTEMCOMPONENTSTOPROVIDEANENCLOSUREFORTHEACCOMMODATIONANDLAYINGINOFINSULATEDCONDUCTORSANDCABLESANDPOSSIBLYTHEACCOMMODATIONOFOTHERELECTRICALEQUIPMENTNOTEDIFFERENTTYPESOFCTSARESHOWNINFIGURE1ANDEXPLAINEDINANNEXA32CABLEDUCTINGSYSTEMCDSASSEMBLYCOMPRISINGADUCTINGLENGTHANDPOSSIBLYOTHERSYSTEMCOMPONENTSTOPROVIDEANENCLOSUREFORTHEACCOMMODATIONANDDRAWINGINOFINSULATEDCONDUCTORSANDCABLESANDPOSSIBLYTHEACCOMMODATIONOFOTHERELECTRICALEQUIPMENTNOTEDIFFERENTTYPESOFCDSARESHOWNINFIGURE1ANDEXPLAINEDINANNEXA33SYSTEMCOMPONENTPARTOFTHESYSTEMWHICHINCLUDESATRUNKINGLENGTHORDUCTINGLENGTH,BTRUNKINGFITTINGORDUCTINGFITTING,CFIXINGDEVICE,DAPPARATUSMOUNTINGDEVICE,ESYSTEMACCESSORYNOTEASYSTEMDOESNOTNECESSARILYINCLUDEALLSYSTEMCOMPONENTSATOEDIFFERENTCOMBINATIONSOFSYSTEMCOMPONENTSMAYBEUSED34TRUNKINGLENGTHMAINCOMPONENTOFACABLETRUNKINGSYSTEMCOMPRISINGABASEWITHONEORMOREACCESSCOVERSWHICHMAYBEOPENEDORREMOVED35DUCTINGLENGTHMAINCOMPONENTOFACABLEDUCTINGSYSTEM,CHARACTERIZEDBYACLOSEDNONCIRCULARCROSSSECTION36FITTINGSYSTEMCOMPONENTTOCONNECT,CHANGEDIRECTIONORTERMINATETRUNKINGLENGTHSORDUCTINGLENGTHS/LICENSEDCOPYINSTITUTEOFTECHNOLOGYTALLAGHT,INSTITUTEOFTECHNOLOGY,SUNOCT08001526BST2006,UNCONTROLLEDCOPY,CBSIEN5008512005637FIXINGDEVICESYSTEMCOMPONENTTOSECUREOTHERSYSTEMCOMPONENTSTOTHEWALL,CEILING,FLOOROROTHERSTRUCTURE38APPARATUSMOUNTINGDEVICESYSTEMCOMPONENTTOACCOMMODATEELECTRICALAPPARATUSSWITCHES,SOCKETOUTLETS,CIRCUITBREAKERS,TELEPHONEOUTLETS,ETCWHICHCANBEANINTEGRALPARTOFELECTRICALAPPARATUSNOTEANAPPARATUSMOUNTINGDEVICECANALSOBEAFITTING,ATRUNKINGLENGTH,ETC39SYSTEMACCESSORYSYSTEMCOMPONENTWHICHPROVIDESASUPPLEMENTARYFUNCTIONNOTEEXAMPLESOFSYSTEMACCESSORIESAREPARTITION,CABLERETAINER,CABLEOUTLET,ETC310METALLICSYSTEMCOMPONENTSYSTEMCOMPONENTWHICHCONSISTSOFMETALONLY311NONMETALLICSYSTEMCOMPONENTSYSTEMCOMPONENTWHICHCONSISTSOFNONMETALLICMATERIALONLY312COMPOSITESYSTEMCOMPONENTSYSTEMCOMPONENTCOMPRISINGBOTHMETALLICANDNONMETALLICMATERIALS313NONFLAMEPROPAGATINGSYSTEMCOMPONENTSYSTEMCOMPONENTWHICHISLIABLETOCATCHFIREASARESULTOFANAPPLIEDFLAME,INWHICHTHEFLAMEDOESNOTPROPAGATEANDWHICHEXTINGUISHESITSELFWITHINALIMITEDTIMEAFTERTHEFLAMEISREMOVED314EXTERNALINFLUENCEFACTORWHICHMAYAFFECTTHESYSTEM315VOID316GLANDDEVICEDESIGNEDTOPERMITTHEENTRYOFACABLEORFLEXIBLECABLEINTOEQUIPMENT,ANDWHICHPROVIDESSEALINGANDRETENTIONITMAYALSOPROVIDEOTHERFUNCTIONSSUCHASEARTHING,BONDING,INSULATION,CABLEGUARDING,STRAINRELIEFORACOMBINATIONOFTHESE317LIVEPARTCONDUCTORORCONDUCTIVEPARTINTENDEDTOBEENERGIZEDINNORMALOPERATION,INCLUDINGANEUTRALCONDUCTOR,BUTBYCONVENTIONNOTAPENCONDUCTORORPEMCONDUCTORORPELCONDUCTORIEV8261208,MOD318CABLEANCHORAGESYSTEMACCESSORYTORELIEVECONDUCTORSINTERMINALSANDTERMINATIONSFROMSTRAINBYRESISTINGTHEPULLANDTWISTFORCESONCABLE/LICENSEDCOPYINSTITUTEOFTECHNOLOGYTALLAGHT,INSTITUTEOFTECHNOLOGY,SUNOCT08001526BST2006,UNCONTROLLEDCOPY,CBSI7EN5008512005319CABLERESTRAINERSYSTEMACCESSORYTORELIEVECONDUCTORSINTERMINALSANDTERMINATIONSFROMSTRAINBYRESISTINGTHEPULLFORCEONCABLEORINSULATEDCONDUCTORS320CABLERETAINERSYSTEMACCESSORYFORTHERETENTIONOFINSULATEDCONDUCTORSORCABLESTOPREVENTTHEMFROMFALLINGOUTWHENTHEACCESSCOVERISOPENEDORREMOVED321GROMMETCOMPONENTORANINTEGRALPARTOFANENCLOSURETOSUPPORTANDPROTECTTHECABLE,CONDUITORDUCTINGORTRUNKINGATTHEPOINTOFENTRYITMAYALSOPREVENTTHEINGRESSOFMOISTUREORCONTAMINANTSSEEFIGURE7322ENTRYMEMBRANECOMPONENTORANINTEGRALPARTOFANENCLOSURETOPROTECTTHECABLE,ANDMAYBEUSEDTOSUPPORTTHECABLE,CONDUITORDUCTINGORTRUNKINGATTHEPOINTOFENTRYITMAYALSOPREVENTTHEINGRESSOFMOISTUREORCONTAMINANTSANENTRYMEMBRANEMAYBEPARTOFAGROMMETSEEFIGURE7323PROTECTINGMEMBRANECOMPONENTORANINTEGRALPARTOFANENCLOSURE,NOTTOBEPENETRATEDINNORMALUSE,TOPROVIDEPROTECTIONAGAINSTINGRESSOFWATERORSOLIDOBJECTSAND/ORTOALLOWTHEOPERATIONOFANACCESSORYSEEFIGURE7324GASKETADDITIONALPARTORMATERIALORANINTEGRALPARTPLACEDBETWEENMATINGSURFACESOFANENCLOSUREWHICHINCOMPRESSIONCONTRIBUTESTOTHEACHIEVEMENTOFTHEDECLAREDINGRESSPROTECTION325REACTIONTOFIRERESPONSEOFACTS/CDSINCONTRIBUTINGBYITSOWNDECOMPOSITIONTOAFIRE,TOWHICHITISEXPOSED,UNDERSPECIFIEDCONDITIONS326FIRERESISTANCEABILITYOFACTS/CDSTOFULFILFORASTATEDPERIODOFTIMETHEREQUIREDSTABILITYAND/ORINTEGRITYAND/ORTHERMALINSULATION,AND/OROTHEREXPECTEDDUTYSPECIFIEDINASTANDARDFIRERESISTANCETESTNOTEFIRERESISTANTADJECTIVEREFERSONLYTOTHISABILITY327SKIRTINGCTS/CDSCTS/CDSINTENDEDTOBEINSTALLEDONTHELOWERPARTOFAWALL328DRYTREATMENTOFFLOORPROCESSFORCLEANINGAND/ORCAREBYWHICHTHEFLOORISTREATEDWITHOUTLIQUIDSORWITHONLYASMALLQUANTITYOFLIQUIDTHEREQUIREDAGENTSAREAPPLIEDANDSPREADINSUCHQUANTITIESTHATNOPOOLSAREFORMEDANDSOAKINGOFTHEFLOORCOVERINGDOESNOTOCCURNOTEEXAMPLESFORDRYTREATMENTARESWEEPINGWITHABROOMORCARPETSWEEPER,VACUUMCLEANING,BRUSHING,CLEANINGWITHADRYCLEANIN
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 小学语文常见的反义词总结
- 中国联通海东市2025秋招市场与服务类专业追问清单及参考回答
- 行政岗位考试试题及答案
- 中国广电常德市2025秋招笔试行测题库及答案网络优化与维护类
- 武威市中石化2025秋招笔试模拟题含答案油品分析质检岗
- 中国广电聊城市2025秋招笔试行测题库及答案行业解决方案经理岗
- 亳州市中石化2025秋招面试半结构化模拟题及答案新材料与新能源岗
- 大唐电力安庆市2025秋招采矿工程专业面试追问及参考回答
- 驻马店市中石油2025秋招面试半结构化模拟题及答案炼化装置操作岗
- 大庆市中石油2025秋招面试半结构化模拟题及答案炼化装置操作岗
- 劳动课冰箱清洁课件
- 2025年公共基础知识考试试题及参考答案详解
- 建筑设计数字化协同工作方案
- 新入行员工安全教育培训课件
- 原生家庭探索课件
- 人教版音乐八年级上册-《学习项目二探索旋律结构的规律》-课堂教学设计
- 《中国人民站起来了》课件 (共50张)2025-2026学年统编版高中语文选择性必修上册
- 中国企业供应链金融白皮书(2025)-清华五道口
- 医院常用消毒液的使用及配置方法
- 2022英威腾MH600交流伺服驱动说明书手册
- 分期支付欠薪协议书范本
评论
0/150
提交评论