版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、Netapp存储映射到AIX操作系统操作手册Netapp存储属于中高端的存储系统,它的FAS6220系统属于常见的带有 FC和NAS功能的综合性存储,今天记录并讲解如何在 AIX系统安装并操作NetAPP的多路径软件和lun磁盘 的识别,查看;步骤如下;1, 解压软件包 tar.zZcatn tap_aix_host_utilities_5.1.tar.Z |tar -xvf -2, 安装: in stallp + 参数 + 路径 +fileset先安装MPIO,然后安装 santools_kittsm2:/tmp/ntap_aix_host_utilities_5.1/MPIO#i nsta
2、llp-aXYd/tmp/ntap_aix_host_utilities_5.1/MPIONetApp.MPIO_Host_Utilities_Kit+Pre-i nstallati on Verificati on +Verify ing select ion s.do neVerify ing requisites.do neResults.SUCCESSESFilesets listed in this sect ion passed pre-i nstallati on verificati on and will be in stalled.Selected FilesetsNetA
3、pp.MPIO_Host_Utilities_Kit.co nfig # NetApp MPIO PCM Host Utilities Kit Path Config ToolNetApp.MPIO_Host_Utilities_Kit.fcp # NetApp MPIO PCM Host Utiliti.NetApp.MPIO_Host_Utilities_Kit.iscsi # NetApp MPIO PCM Host Utilities Kit iSCSIDisk ODM Sta nzasNetApp.MPIO_Host_Utilities_
4、Kit.pcmodm # NetApp MPIO PCM Host Utilities KitPCM Friend ODM Sta nzas+BUILDDATE Verification .+Verify ing build dates.do neFILESET STATISTICS4 Selected to be in stalled, of which:4Passed pre-i nstallati on verificati on4 Total to be in stalled0503-409 in stallp:bosboot verificati on start i
5、n g.in stallp:bosboot verificati on completed.+In stalli ng Software.+in stallp:APPLYING software for:NetApp.MPIO_Host_Utilities_Kit.pcmodm NetApp.MPIO_Host_Utilities_Kit.iscsi NetApp.MPIO_Host_Utilities_Kit.fcp NetApp.MPIO_Host_Utilities_Kit.co nfig Copyright (c) 2003-20
6、10 NetApp, I nc.sysck: 3001-036 WARNING: File /opt/NetApp/MPIO_Host_Utilities_Kit/NOTICE.PDF is also owned by fileset NetApp.MPIO_Host_Utilities_Kit.iscsi.sysck: 3001-036 WARNING: File /opt/NetApp/MPIO_Host_Utilities_Kit/NOTICE.TXT is also owned by fileset NetApp.MPIO_Host_Utilities_Kit.iscsi.Fini s
7、hed process ing all filesets.(Total time: 6 secs).0503-409 in stallp:bosboot verificati on start in g.in stallp:bosboot verificati on completed.0503-408 in stallp:bosboot process start in g.bosboot: Boot image is 42972 512 byte blocks.0503-292 This update will n ot fully take effect un til after a s
8、ystem reboot.* * * A T T E N T I O N * * *System boot image has bee n updated. You should reboot thesystem as soon as possible to properly in tegrate the cha nges and to avoid disrupti on of curre nt function ality.in stallp:bosboot process completed.+Summaries:+In stallati on SummaryNameLevelPartEv
9、entResultNetApp.MPIO_Host_Utilities_ USRAPPLYSUCCESSNetApp.MPIO_Host_Utilities_ USRAPPLYSUCCESSNetApp.MPIO_Host_Utilities_ USRAPPLYSUCCESSNetApp.MPIO_Host_Utilities_ USRAPPLYSUCCESStsm2:/tmp/ntap_aix_host_utilities_5.1/MPIO#lslpp -l |grep -i netappNetApp.MPIO_Host_Utiliti
10、es_Kit.co nfigCOMMITTEDNetApp MPIO PCM Host UtilitiesNetApp.MPIO_Host_Utilities_Kit.fcpCOMMITTEDNetApp MPIO PCM Host UtilitiesNetApp.MPIO_Host_Utilities_Kit.iscsiCOMMITTEDNetApp MPIO PCM Host UtilitiesNetApp.MPIO_Host_Utilities_Kit.pcmodmCOMMITTEDNetApp MPIO PCM Host Util
11、itiestsm2:/tmp/ntap_aix_host_utilities_5.1/MPIO#cd .tsm2:/tmp/ntap_aix_host_utilities_5.1#pwd/tmp/n tap_aix_host_utilities_5.1tsm2:/tmp/ntap_aix_host_utilities_5.1#lsMPIOSANSAN_Tool_Kittsm2:/tmp/ntap_aix_host_utilities_5.1#cd *ittsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#pwd/tmp/ntap_aix_hos
12、t_utilities_5.1/SAN_Tool_Kittsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#i nstallp-aXYd/tmp/ntap_aix_host_utilities_5.1/MPIONetApp.MPIO_Host_Utilities_Kittsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#i nstallp-aXYd/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kittsm2:/tmp/ntap_aix_host_utilit
13、ies_5.1/SAN_Tool_Kit#lsNetApp.SAN_toolkittsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#i nstallp-aXYd/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_KitNetApp.SAN_toolkit+Pre-i nstallati on Verificati on.+Verify ing select ion s.do neVerify ing requisites.”。neResults.SUCCESSESFilesets listed in this
14、sect ion passed pre-i nstallati on verificati on and will be in stalled.Selected FilesetsNetApp.SAN_toolkit.sa nlu n # NetApp SAN Toolkit san lun+BUILDDATE Verification .+Verify ing build dates.do neFILESET STATISTICS1 Selected to be in stalled, of which:1 Passed pre-i nstallati on verificati
15、 on1 Total to be in stalled+In stalli ng Software.+in stallp:APPLYING software for:NetApp.SAN_toolkit.sa nlu n Copyright (c) 2003-2010 NetApp, I nc.Fini shed process ing all filesets.(Total time: 1 secs).+Summaries:NameLevelPartEventResultSUCCESSAIX开始扫描activeactivehdisk000c59412a7d7466arootvg
16、hdisk100c3afa442c5c5f6rootvghdisk2noneNonehdisk3noneNonehdisk4noneNonehdisk5noneNonehdisk6noneNonehdisk7noneNonehdisk8noneNonehdisk9noneNonehdisk10noneNoneIn stallati on SummaryNetApp.SAN_toolkit.sa nlu nUSRAPPLYtsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#tsm2:/tmp/ntap_aix_host_utilit
17、ies_5.1/SAN_Tool_Kit#tsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#tsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#tsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#tsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#which san lun/usr/b in/sanluntsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool
18、_Kit#cd /opt/NetApptsm2:/opt/NetApp#lsMPIO_Host_Utilities_Kit sa ntoolstsm2:/opt/NetApp#cd san toolstsm2:/opt/NetApp/sa ntools#lsNOTICE.PDF NOTICE.TXT binmantsm2:/opt/NetApp/sa ntools#cd bintsm2:/opt/NetApp/sa ntools/bi n#lssan _vers ion sanluntsm2:/opt/NetApp/sa ntools/b in #sa nlun lun showno con
19、troller LUNs availabletsm2:/opt/NetApp/sa ntools/bi n#tsm2:/opt/NetApp/sa ntools/bi n#tsm2:/opt/NetApp/sa ntools/b in #cfgmgr -v#存储那边配置好,映射好后,cfgmgr is running in phase 2 tsm2:/opt/NetApp/sa ntools/bi n#tsm2:/opt/NetApp/sa ntools/bi n#tsm2:/opt/NetApp/sa ntools/bi n#lspvhdiskllnoneNonetsm2:/opt/NetA
20、pp/santools/bin#用 sanlun 命令查看其实还需要设置磁盘属性,要看netapp的官方文档设置 deep ,queue_depth等;tsm2:/opt/NetApp/sa ntools/b in #sa nlun lun showcon troller:lun-path namedevice file nameadapterprotocollun sizelun stateFAS6220-2A:/vol/l un1_aix_tsm_vol/aix_tsm_06hdisk10fcs0FCP500.1g (536952700928)GOODFAS6220-2A:/vol/l u
21、n1_aix_tsm_vol/aix_tsm_07hdisk11fcs0FCP500.1g (536952700928)GOODFAS6220-2A:/vol/l un1_aix_tsm_vol/aix_tsm_00hdisk4fcs0FCP500.1g (536952700928)GOODFAS6220-2A:/vol/l un1_aix_tsm_vol/aix_tsm_01hdisk5fcs0FCP500.1g (536952700928)GOODFAS6220-2A:/vol/l un1_aix_tsm_vol/aix_tsm_02hdisk6fcs0FCP500.1g (5369527
22、00928)GOODFAS6220-2A:/vol/l un1_aix_tsm_vol/aix_tsm_03hdisk7fcs0FCP500.1g (536952700928)GOODFAS6220-2A:/vol/l un1_aix_tsm_vol/aix_tsm_04hdisk8fcs0FCP500.1g (536952700928)GOODFAS6220-2A:/vol/l un1_aix_tsm_vol/aix_tsm_05hdisk9fcs0FCP500.1g (536952700928) GOODtsm2:/opt/NetApp/sa ntools/bi n#lsdev -Cc d
23、iskhdisk0 Available 01-08-00 SAS Disk Drivehdisk1 Available 01-08-00 SAS Disk Drivehdisk2 Available 01-08-00 SAS Disk Drivehdisk3 Available 01-08-00 SAS Disk Drivehdisk4Available 05-00-02MPIONetAppFCPDefaultPCM Diskhdisk5Available 05-00-02MPIONetAppFCPDefaultPCM Diskhdisk6Available 05-00-02MPIONetAp
24、pFCPDefaultPCM Diskhdisk7Available 05-00-02MPIONetAppFCPDefaultPCM Diskhdisk8Available 05-00-02MPIONetAppFCPDefaultPCM Diskhdisk9Available 05-00-02MPIONetAppFCPDefaultPCM Diskhdisk10 Available 05-00-02 MPIO NetApp FCP Default PCM Disk hdisk11 Available 05-00-02 MPIO NetApp FCP Default PCM Disk tsm2:
25、/opt/NetApp/santools/bin#sanlun lun show-p # -p 参数查看多路径状态ONTAP_PATH: FAS6220-2A:/vol/lu n1_aix_tsm_vol/aix_tsm_05LUN: 5LUN Size: 500.1g (536952700928)Host Device: hdisk9LUN State: GOODCo ntroller_CF_State: Cluster En abledCon troller Part ner: FAS6220-2BMultipath Provider: AIX NativeMultipathi ng Al
26、gorithm: roun d_rob inMPIO path statusCon trollerAIXpathMPIOtypepathCon trollerAIX MPIO path priorityhostHBAtarget HBAportEn abledprimary path0fcs00a1En abledsec on dary path1fcs00a1En abledprimary path2fcs01c1En abledsec on dary path3fcs01a1En abledprimary path4fcs20b1En abledsec on dary path5fcs20
27、b1En abledprimary path6fcs21a1En abledsec on dary path7fcs21c1ONTAP_PATH: FAS6220-2A:/vol/lu n1_aix_tsm_vol/aix_tsm_04LUN: 4LUN Size: 500.1g (536952700928)Host Device: hdisk8LUN State: GOODCo ntroller_CF_State: Cluster En abledCon troller Part ner: FAS6220-2BMultipath Provider: AIX NativeMultipathi
28、ng Algorithm: roun d_rob inMPIO path statusCon trollerAIXpathMPIOtypepathCon trollerAIX MPIO path priorityhostHBAtarget HBAportEn abledprimary path0fcs00a1En abledsec on dary path1fcs00a1En abledprimary path2fcs01c1En abledsec on dary path3fcs01a1En abledprimary path4fcs20b1En abledsec on dary path5
29、fcs20b1En abledprimary path6fcs21a1En abledsec on dary path7fcs21c1ONTAP_PATH: FAS6220-2A:/vol/lu n1_aix_tsm_vol/aix_tsm_03LUN: 3LUN Size: 500.1g (536952700928)Host Device: hdisk7LUN State: GOODCo ntroller_CF_State: Cluster En abledCon troller Part ner: FAS6220-2BMultipath Provider: AIX Native Multi
30、pathi ng Algorithm: roun d_rob inMPIO path statusCon trollerAIXpathMPIOtypepathCon trollerAIX MPIO path priorityhostHBAtarget HBAportEn abledprimary path0fcs00a1En abledsec on dary path1fcs00a1En abledprimary path2fcs01c1En abledsec on dary path3fcs01a1En abledprimary path4fcs20b1En abledsec on dary
31、 path5fcs20b1En abledprimary path6fcs21a1En abledsec on dary path7fcs21c1ONTAP_PATH: FAS6220-2A:/vol/lu n1_aix_tsm_vol/aix_tsm_02LUN: 2LUN Size: 500.1g (536952700928)Host Device: hdisk6LUN State: GOODCo ntroller_CF_State: Cluster En abledCon troller Part ner: FAS6220-2BMultipath Provider: AIX Native
32、Multipathi ng Algorithm: roun d_rob inMPIO path statusCon trollerAIXpathMPIOtypepathCon trollerAIX MPIO path priorityhostHBAtarget HBAportEn abledprimary path0fcs00a1En abledsec on dary path1fcs00a1En abledprimary path2fcs01c1En abledsec on dary path3fcs01a1En abledprimary path4fcs20b1En abledsec on
33、 dary path5fcs20b1En abledprimary path6fcs21a1En abledsec on dary path7fcs21c1ONTAP_PATH: FAS6220-2A:/vol/lu n1_aix_tsm_vol/aix_tsm_01LUN: 1LUN Size: 500.1g (536952700928)Host Device: hdisk5LUN State: GOODCo ntroller_CF_State: Cluster En abledCon troller Part ner: FAS6220-2BMultipath Provider: AIX N
34、ativeMultipathi ng Algorithm: roun d_rob inMPIO path statusCon trollerAIXpathMPIOtypepathCon trollerAIX MPIO path priorityhostHBAtarget HBAportEn abledprimary path0fcs00a1En abledsec on dary path1fcs00a1En abledprimary path2fcs01c1En abledsec on dary path3fcs01a1En abledprimary path4fcs20b1En ableds
35、ec on dary path5fcs20b1En abledprimary path6fcs21a1En abledsec on dary path7fcs21c1ONTAP_PATH: FAS6220-2A:/vol/lu n1_aix_tsm_vol/aix_tsm_00LUN: 0LUN Size: 500.1g (536952700928)Host Device: hdisk4LUN State: GOODCo ntroller_CF_State: Cluster En abledCon troller Part ner: FAS6220-2BMultipath Provider:
36、AIX NativeMultipathi ng Algorithm: roun d_rob inMPIO path statusCon trollerAIXpathMPIOtypepathCon trollerAIX MPIO path priorityhostHBAtarget HBAportEn abledprimary path0fcs00a1En abledsec on dary path1fcs00a1En abledprimary path2fcs01c1En abledsec on dary path3fcs01a1En abledprimary path4fcs20b1En abledsec on dary path5fcs20b1En abledprimary path6fcs21a1En abledsec on dary path7fcs21c1ONTAP_PATH: FAS6220-2A:/vol/lu n1_aix_tsm_vol/aix_tsm_07
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026年农业工程高级工程师笔试模拟题集及设施农业解析
- 2026年外贸实务与跨境贸易流程题库
- 2026年节能监察工作纪律与廉政风险防控问答
- 2026年饲料系统版饲料案件查处程序知识试题
- 2026年心理测试在面试中的应用及应对
- 2026年中国宝武钢铁集团招聘面试心得与压力面试应对
- 2026年家庭地震应急包配置与避险区域选择题库
- 2026年统计信息发布中的涉密信息审查流程知识问答
- 2026年人工智能在农业病虫害识别中的应用题
- 2026年国考参公单位档案局档案查阅题
- 荆州市国土空间总体规划(2021-2035年)
- 湘少版五年级英语下册《期中测试卷》(附答案)
- 2023玻纤增强聚氨酯门窗工程技术规程
- 建筑机械钢筋机械
- 《少年游击队》绘本(课件)(17) 通用版美术
- 中信银行股份有限公司信用卡中心招聘考试参考题库含答案详解
- 农机专业合作社安全生产责任书合同
- 骨折治疗的原则与理念
- 印度尼西亚社会与文化知到章节答案智慧树2023年浙江越秀外国语学院
- 胶粉聚苯颗粒外墙保温技术交底
- 《复习现在进行时》课件
评论
0/150
提交评论