1、型号GB型号(整机)制冷能力(kW)输入功率(kW)季节能效比*1(SEER2399h)季节能效比*1(SEER1136h)季节能效比等级室内室外*2*3*2*3*2*3怡岚CS-HE9KF1 CS-HE9KF1NCU-HE9KF1KFR-26GW/BpHF1KFR-26GW/BpHF1N2.6(0.9-3.1)0.565(0.19-0.95)0.600(0.19-0.95)6.255.725.655.221CS-HE13KF1CS-HE13KF1NCU-HE13KF1KFR-35GW/BpHF1KFR-35GW/BpHF1N3.5(0.9-4.2)0.84(0.2-1.2)0.88(0.2-
2、1.2)6.105.975.385.221CS-HE18KF1CS-HE18KF1NCU-HE18KF1KFR-50GW/BpHF1KFR-50GW/BpHF1N5.0(1.0-5.3)1.34(0.2-1.6)1.39(0.2-1.6)5.685.414.944.731怡炫CS-FE9KF2CS-FE9KF2CCS-FE9KF2GCS-FE9KF2PCU-FE9KF2KFR-26GW/BpFF2KFR-26GW/BpFF2CKFR-26GW/BpFF2GKFR-26GW/BpFF2P2.6(0.9-3.1) -0.72(0.19-0.95) -5.05 -4.522CS-FE13KF2CS-
3、FE13KF2CCS-FE13KF2GCS-FE13KF2PCU-FE13KF2KFR-35GW/BpFF2KFR-35GW/BpFF2CKFR-35GW/BpFF2GKFR-35GW/BpFF2P3.5(0.9-4.1) -1.00(0.2-1.35) -5.1 -4.512怡迅CS-JE9KF1SCU-JE9KF1KFR-26GW/BpJF1S2.6(0.9-3.1)0.65(0.19-0.95)0.72(0.19-0.95)5.455.054.924.522CS-JE13KF1S CU-JE13KF1KFR-35GW/BpJF1S3.5(0.9-4.1)0.92(0.2-1.35)1.0
4、0(0.2-1.35)5.585.14.934.512怡睿CS-LE9KF1ACS-LE9KF1GCS-LE9KF1PCS-LE9KF1NCU-LE9KF1CU-LE9KF1KFR-25GW/BpLF1AKFR-25GW/BpLF1G2.5(0.9-3.05)0.71(0.19-1.1)0.725(0.19-1.1)4.644.214.233.933CS-LE13KF1ACS-LE13KF1GCS-LE13KF1PCS-LE13KF1NCU-LE13KF1CU-LE13KF1KFR-35GW/BpLF1AKFR-35GW/BpLF1G3.5(0.9-3.95)1.05(0.2-1.4)1.15
5、(0.2-1.4)4.714.454.23.923CS-LE18KF1ACS-LE18KF1GCS-LE18KF1PCS-LE18KF1NCU-LE18KF1CU-LE18KF1KFR-50GW/BpLF1AKFR-50GW/BpLF1G5.0(1.0-5.2)1.9(0.24-2.0)2.05(0.24-2.15)4.714.423.893.633怡能CS-E9KF1CU-E9KF1KFR-25GW/BpF12.5(0.9-3.05)0.71(0.19-1.1)0.725(0.19-1.1)4.644.214.233.933CS-E13KF1CU-E13KF1KFR-35GW/BpF13.5
6、(0.9-3.95)1.05(0.2-1.4)1.15(0.2-1.4)4.714.454.23.923CS-E18KF1CU-E18KF1KFR-50GW/BpF15.0(1.0-5.2)1.9(0.24-2.0)2.05(0.24-2.15)4.714.423.893.633怡能CS-G9KF1CU-G9KF1KFR-25GW/Bp2F12.5(0.9-3.05)0.73(0.22-1.17)0.73(0.22-1.17)4.214.213.923.923CS-G13KF1CU-G13KF1KFR-35GW/Bp2F13.5(0.9-3.95)1.16(0.23-1.45)1.16(0.2
7、3-1.45)4.444.443.913.913下乡CS-NE9KF2CU-NE9KF2KFR-25GW/BpNF22.5(0.9-3.05)0.725(0.19-1.1)0.725(0.19-1.1)4.214.213.933.933CS-NE13KF2CU-NE13KF2KFR-35GW/BpNF23.5(0.9-3.95)1.15(0.2-1.4)1.15(0.2-1.4)4.454.453.923.923下乡 CS-NE9KF1CU-NE9KF1KFR-25GW/BpNF12.5(0.9-3.05)0.725(0.19-1.1)0.725(0.19-1.1)4.214.213.933.
8、933CS-NE13KF1CU-NE13KF1KFR-35GW/BpNF13.5(0.9-3.95)1.15(0.2-1.4)1.15(0.2-1.4)4.454.453.923.923工程CS-PE9KF1CU-PE9KF1KFR-25GW/BpPF12.5(0.9-3.05)0.725(0.19-1.1)0.725(0.19-1.1)4.214.213.933.933CS-PE13KF1CU-PE13KF1KFR-35GW/BpPF13.5(0.9-3.95)1.15(0.2-1.4)1.15(0.2-1.4)4.454.453.923.923CS-PE18KF1CU-PE18KF1KFR
9、-50GW/BpPF15.0(1.0-5.2)2.05(0.24-2.15)2.05(0.24-2.15)4.424.423.633.633尊铂CS-VE18DFF1NCS-VE18DFF1RCU-VE18FF1CU-VE18FF1KFR-52LW/BpVDF1NKFR-52LW/BpVDF1R5.2(1.0-5.6)1.58(0.21-2.0)1.71(0.21-2.0)5.374.824.574.142怡睿CS-VE27DFF1NCS-VE27DFF1RCU-VE27FF1CU-VE27FF1KFR-72LW/BpVDF1NKFR-72LW/BpVDF1R7.2(1.0-7.5)2.28(
10、0.21-2.6)2.36(0.21-2.6)5.444.944.554.221CS-VE18FF1NCS-VE18FF1RCU-VE18FF1CU-VE18FF1KFR-52LW/BpVF1NKFR-52LW/BpVF1R5.2(1.0-5.6)1.58(0.21-2.0)1.71(0.21-2.0)5.374.824.574.142CS-VE27FF1NCS-VE27FF1RCU-VE27FF1CU-VE27FF1KFR-72LW/BpVF1NKFR-72LW/BpVF1R7.2(1.0-7.5)2.28(0.21-2.6)2.36(0.21-2.6)5.444.944.554.221*1
11、*1注注: :季季节节能能效效比比2399h2399h以以GB/TGB/T 7725-20047725-2004为为标标准准计计算算所所得得; ;季季节节能能效效比比1136h1136h以以GBGB 21455-200821455-2008为为标标准准计计算算所所得得*2*2注注:2012:2012年年5 5月月1 1日日前前有有效效。*3*3注注:2012:2012年年5 5月月1 1日日后后有有效效。(国国标标新新检检测测标标准准 JJF1261.4-2012JJF1261.4-2012,5 5月月1 1日日开开始始强强制制执执行行) )*4*4注注: :适适用用面面积积因因楼楼宇宇结结构
12、构、朝朝向向、层层数数等等不不同同会会有有不不同同变变化化,此此数数据据仅仅供供参参考考。* * 注注: :此此数数据据仅仅供供参参考考。具具体体性性能能参参数数以以机机身身铭铭牌牌为为准准。尊铂制暖规格(mm)循环风量(m3/h)噪音 (dB)能力(kW)输入功率(kW)制暖季节能效比*1(HSPF)循环风量(m3/h)噪音 (dB)室内机室内室外*2*3*2*3室内室外长宽69042473.5(0.9-4.75)0.83(0.17-1.26)0.85(0.17-1.33)3.483.39702424884822469642484.5(0.9-5.8)1.15(0.2-1.61)1.24(0
13、.2-1.7)3.233.09696425084822480446506.0(0.9-5.8)1.77(0.21-2.7)1.80(0.21-2.93)2.972.85858465284822478042473.4(0.9-4.25) -0.85(0.19-1.2) -3.25810424880321581042484.5(0.9-4.1) -1.0(02-1.35) -3.05828425080321578042473.4(0.9-4.25)0.84(0.19-1.2)0.85(0.19-1.2)3.263.25810424880321281042484.5(0.9-5.8)1.18(0.2
14、-1.61)1.23(0.2-1.70)3.153.05828425080321272040463.3(0.9-4.0)0.84(0.19-1.14)0.85(0.19-1.14)2.972.95720404880321281042484.25(0.9-5.0)1.12(0.2-1.42)1.12(0.2-1.42)2.822.738104250803212制冷87646506.0(0.9-8.1)1.95(0.21-2.8)1.95(0.21-3.04)2.722.6918465280321272040463.3(0.9-4.0)0.84(0.19-1.14)0.85(0.19-1.14)2
15、.972.95720404880321581042484.25(0.9-5.0)1.12(0.2-1.42)1.12(0.2-1.42)2.822.73810425080321587646506.0(0.9-8.1)1.95(0.21-2.8)1.95(0.21-3.04)2.722.6918465280321570240473.3(0.9-4.0)0.88(0.22-1.26)0.88(0.22-1.26)2.822.82702404980321582242494.25(0.9-4.7)1.15(0.23-1.45)1.15(0.23-1.45)2.642.64846425180321572
16、040463.30(0.9-4.0)0.85(0.19-1.14)0.85(0.19-1.14)2.952.95720404880321281042484.25(0.9-5.0)1.12(0.2-1.42)1.12(0.2-1.42)2.732.73810425080321272040463.3(0.9-4.0)0.85(0.19-1.14)0.85(0.19-1.14)2.952.95720404880321581042484.25(0.9-5.0)1.12(0.2-1.42)1.12(0.2-1.42)2.732.7381042508032157204046 3.3(0.9-4.0)0.8
17、5(0.19-1.14)0.85(0.19-1.14)2.952.95720404880321581042484.25(0.9-5.0)1.12(0.2-1.42)1.12(0.2-1.42)2.732.73810425080321587646506.0(0.9-8.1)1.95(0.21-3.04)1.95(0.21-3.04)2.62.6918465280321596042526.40(1.0-8.7)2.0(0.2-3.0)2.21(0.2-3.0)3.022.669604252540357102043518.8(1.0-10.8)2.8(0.2-3.7)3.0(0.2-4.13)2.8
18、22.581020435354035796042526.1(1.0-8.4)1.7(0.2-2.7)1.91(0.2-2.7)3.022.669604252540357102043518.5(1.0-10.5)2.5(0.2-3.4)2.7(0.2-3.83)2.822.5810204353540357配管净重量(kg)参考使用面积( m2)*4室外机长度范围高度差管径随机附送配管长度冷媒种类/量追加冷媒量冷媒量开始追加长度高长宽高mminchmkgg/mm室内机室外机制冷28978028954031553/8,1/43.8R410A/0.812078.52513-17289780289624
19、31551/2,1/43.8R410A/0.972078.52817-23289900320795315101/2,1/43.8R410A/1.32078.54325-3328578028962431553/8,1/42.8R410A/0.622077.522.512-1628578028954031553/8,1/42.8R410A/0.852077.525.517-2328578028962431553/8,1/43.8R410A/0.720782313-1728578028954031553/8,1/43.8R410A/0.8520782617-2328572027553031553/8
20、,1/42.8R410A/0.5920782012-1628578028962431553/8,1/42.8R410A/0.6420782417-23规格(mm)室内机285780289540315101/2,1/42.8R410A/1.1520783025-3328572027553031553/8,1/42.8R410A/0.592077.52012-1628578028962431553/8,1/42.8R410A/0.6420782417-23285780289540315101/2,1/42.8R410A/1.1520783025-3328572027553031553/8,1/42
21、.8R22/0.582557.52212-1628578028962431551/2,1/42.8R22/0.5825582517-2328572027553031553/8,1/42.8R410A/0.5920782012-1628578028962431553/8,1/42.8R410A/0.6420782417-2328572027553031553/8,1/42.8R410A/0.592077.52012-1628578028962431553/8,1/42.8R410A/0.6420782417-2328572027553031553/8,1/4 -R410A/0.592077.52
22、012-1628578028962431553/8,1/4 -R410A/0.6420782417-23285780289540315101/2,1/4 -R410A/1.1520783025-331880780289540315101/2,1/43.8R410A/1.25207383026-341880900320795315105/8,1/43.8R410A/1.5357384336-481880780289540315101/2,1/43.8R410A/1.25207373026-341880900320795315105/8,1/43.8R410A/1.5357374336-48电源线
23、规格电源插头形式压缩机类型(单转子/双转子)控制方式热交换器排/级/FPI主要功能辅助功能备注制暖蒸发器冷凝器14-191.5mm2310A单转子毛细管21519224171、温度显示;2、强劲/超静模式;3、智能(节能)模式;4、舒适模式;5、柔湿功能。6、空清功能。-1、设定温度/室内温度/人感温度显示可切换;2、SEER等级1级以上,配管外机搭载18-251.5mm2310A单转子电子膨胀阀215212281924-331.5mm2316A双转子215192361813-181.5mm2310A单转子毛细管2162012820强劲/超静模式 -配管外机搭载17-231.5mm2310A单
24、转子毛细管216201241813-191.5mm2310A单转子毛细管21619128191、强劲/超静模式;2、智能(节能)模式;3、舒适模式;4、柔湿功能。压缩机电加热功能配管外机搭载18-251.5mm2310A单转子216212241713-181.5mm2310A单转子毛细管21619124191、豪华双重面板;2、强劲/超静模式; 3、智能模式;4、舒适模式。 -配管外机搭载17-231.5mm2310A单转子2162112818参考使用面积( m2)*424-331.5mm2316A单转子电子膨胀阀216192241713-181.5mm2310A单转子毛细管2161912419强劲/超静模式 -配管外机搭载17-231.5mm2310A单转子216211281824-331.5mm2316A单转子电子膨胀阀216192241713-181.5mm2310A单转子毛细管2161912419强劲/超静模式 -配管外机搭载17-231.5mm2310A单转子216221281913-181.5mm2310A单转子毛细管21619124191、彩色面板,带花纹;2、强劲/超静模式;3、智能模式;4、舒适模式。-配管外机搭载17-231.5mm2310A单转子21
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 中国石灰消化机项目投资可行性研究报告
- 中国高强度瓦楞纸项目投资可行性研究报告
- 专用备捻管行业深度研究报告
- 客户关系管理的多场景工具包
- 企业物流运输管理与成本控制模板
- 中国芯得浸膏项目投资可行性研究报告
- 中国蔬菜保藏项目投资可行性研究报告
- 中国栈板项目投资可行性研究报告
- 2025年高三生物物种形成机制题
- 数控交流稳压电源行业深度研究报告
- 家政保洁员礼仪培训课件
- 大学校园消防安全检查表
- smt代工协议合同范本
- 数据标注产业发展研究报告(2025年)
- 2025年宏观经济与政策分析能力考试题及答案
- 2025年天津市公务员录用考试审计专业试题解析
- 机场安全审计方案(3篇)
- 美的楼宇科技双微运营方案
- (高清版)DBJ∕T 13-278-2025 《福建省电动汽车充电基础设施建设技术标准》
- 2025年DeepSeek核心技术白话解读报告
- 企业合规整改方案标准化研究与实践
评论
0/150
提交评论