1、1.0introduction介绍1.1TEST SCOPE试验范围This standard specifies an accelerated laboratory atmospheric corrosion test. The testing environment addressed is similar in effect to that of the salt load/ climatic part of the proving ground corrosion test procedure, CETP 00.00-R-343 and yields corresponding res

2、ults. The objective of the test is to allow evaluation of the corrosion resistance of metals in environments where there is a significant influence of chloride ions, mainly as sodium chloride from a marine source or by winter road de-icing salt. The laboratory test provides full exposure to the salt

3、 load and humidity environment. It does not attempt to simulate other engraving factors such as mud loads, temperature stresses or wear.It serves as a general purpose atmospheric corrosion test and applies to a variety of materials, coatings, and interactions of materials, both as test specimens or

4、in designed components. The test can be used as a design verification method in order to (a) develop and qualify new corrosion resistant products, (b) develop new pre-treatments and finishing processes, (c) select materials and, (d) perform quality control of the final product.本标准是关于一项在实验室里加速进行的大气腐蚀

5、试验。本文所述的试验环境类似于试验场腐蚀试验程序 CETP00.00-R-343 中的盐负荷 / 环境影响部分,得出相应的结果。试验目的在于评估金属在富含氯化物的环境中(主要是海水中的盐或冬天用于融雪的盐)的抗腐蚀性。该实验室试验主要是将试验件完全暴露在湿润的盐负荷环境中,而非模拟其他摩擦因素如泥负荷、温度压力或磨损。该试验主要作为一项大气腐蚀试验,适用于各种各样的材料、涂层、试样或设计零部件材料的相互作用。该试验可作为一种验证设计的方法,用于 (a) 开发并验证新的抗腐蚀产品; (b) 开发新的预处理和表面处理工艺; (c) 选择材料; (d)对最终产品的质量控制。The standard

6、specifies controlled conditions for equipment and proceduresto allow thetest to be performedwithahigh degree of repeatability and reproducibility. It is designed to be suitable to run in various climate chambers, either as a fully automated procedure or with partial manual operations.本标准说明了设备和程序的受控条

7、件,让实验具有高度的重复性和再现性。本标准适用于多种环境试验箱,包括全自动试验或部分手动操作的试验。1.2 SUMMARY OF TEST CONTENT The workday test procedure consists of:试验内容摘要工作日的试验程序由以下几个方面组成:A 6 h wet phase at room temperature. with intermittent exposure to salt solution (0.5% NaCl).A 2.5 h transition phase with drying under climate control.A 15.5

8、h phase with constant temperature and humidity (50C, 70% RH).室温下 6小时的加湿阶段,间歇曝露到0.5%的氯化钠溶液中2.5小时的过渡阶段,通过环境控制进行烘干15.5小时的恒温恒湿阶段 (50 C, 70% RH)After repeating this procedure Mon-Fri a 48 h weekend phase under continued constant climate control is added.从周一到周五重复该试验程序后,在周末加入持续恒定环境控,进行48 小时的试验。1.3COMMONALI

9、TY共通性This is a CONTROL TEST and can be used to qualify components throughout the world.The test may be conductedatany location havingthe necessary equipment and facilities.Proposed revisionsto this procedure must besubmitted per FAP03-179.这是一项可验证世界上所有的零部件的控制试验,可在任何地方进行,只要具备所需的设备仪器。对本试验程序的修改建议必须按FAP0

10、3-179 提交。2.0Instrumentation仪器The following elements are usually required to conduct the test procedure:进行试验程序一般需要以下仪器:2.1Compressed, clean air of 4 - 6 bars for cleaning salt solution from spray nozzles, as a source for the renewal of chamber air and for humidification, supplied by spray humidifiers

11、.2.14-6 bar的干净的压缩空气,用于清理喷嘴上的盐溶液、箱内换气和喷雾加湿器进行加湿。2.2A low conductivity water supply (20 S max) for humidification or evaporative spray humidifiers and for the preparation of salt solutions.2.2一根低导电率的供水管(最大 20 S),用于加湿或喷雾加湿器以及准备盐溶液。2.3A tank for preparation and storage of salt solution or, alternatively

12、, a system for direct on-line mixing of water and saturated NaCl solution to the actual concentration (0.5 0.05%by weight)2.3一个用于准备和存储盐溶液的水槽,或者一套直接在线按实际浓度(0.5 0.05%,按重量)混合水和饱和氯化钠溶液的系统。2.4A conductivity meter with built-in temperature compensation for preparation and control ofthe 0.5% NaCl salt solu

13、tion (conductivity: 8.3 mS/cm + 0.80 at 20 C). A 0.50% by weightNaCl solution is used as a calibration standard at each measurement.2.4一个带内置温度补偿的电导仪,用于准备和控制0.5%的氯化钠盐溶液(温度为 20 C时的导电性: 8.3 mS/cm + 0.80)。 一份按重量为 0.50%的氯化钠溶液,作为每次测量时的校正标准。2.5A high quality device for independent control of temperature an

14、d relative humidity shall be accessible. This instrument shall on a stipulated regular interval (Ref 5.4) be used for independent monitoring and calibration of the conditions in the very test plane of the exposure chamber. The total measurement error must not exceed 0C.1.2.5一套高质量的设备,用于独立控制温度和相对湿度。该设

15、备按照规定的时间间隔(参考 5.4),独立监控和校正试验箱李的试验平面上的各项条件,测量总误差不超过0.1 C。2.6Racks of inert material for support and aligned fixation of test specimens must not hamper a free air-flow around the test objects, nor collect standing wetness. The test objects in a rack must not screen one another from the salt solution d

16、ownfall and they should be exposed with the stipulated exposure angle to the spray (15- 20 degrees inclination from vertical).2.6由惰性材料制成的夹具,用于支撑、排列和固定试样,但不得妨碍试样周围的空气流通,不得累积水分。夹具上的试样不得相互遮蔽导致盐溶液淋不到试样上。试样应按规定的角度曝露到喷雾中(偏离垂直线 15-20度)。2.7Pressurized hand-spray equipment for application of the 0.5% NaCl so

17、lution2.7如需采取手动喷洒,应使用适用于 0.5%盐溶液的加压型手动喷雾器,喷雾器的容量必须能2.8Funnels, beakers/ measuring glasses and a balance with at least 0.1 g accuracy for monitoring and calibration of salt solution downfall throughout the test plane of the exposure chamber.2.8漏斗、烧杯 /量杯以及精确度至少为 0.1g的天平,用于监控和校准曝露箱中试验平面上落下的盐溶液。2.9 All

18、test measurement equipment must be calibrated and maintained per FAP03-015, Control, Calibration, and Maintenance of Measurement and Test Equipment.2.9所有试验的测量设备的校准和维护必须按照 FAP03-015测量和试验设备的控制,校准和维护程序。2.10All applicable safety guidelines and procedures must be followed.2.10试验须遵守所有适用的安全指引和安全程序。3.0Equip

19、ment and facilities设备设施The necessary, permanently installed facilityto conductthe test consists of a programmable humiditychamber ofgood quality. It is preferably equipped withan integratedrig for spraying salt solutionof the requiredamount andaccuracy, cooling capacity and agood internal circulatio

20、nsystemfor the conditionedair (Fig. 1). The exposurechamber shall be designed so that the test conditionsdescribedin the subsequent paragraphs can be obtained,controlled, and monitored during the test.试验所需的永久性安装的设施包括一个可编程的高质量湿度箱。湿度箱中最好能配备一套喷量准确度高的综合性盐雾喷洒装置、冷却装置和一套性能良好的空气内循环系统(如图 1)。曝露箱应按要求设计,以使下文所述的

21、试验过程中的各项条件能在得到满足、控制和监控。Fig. 1 Schematic view of a climate chamber equipped with functions suited for performance of the described test procedure: 1. Chamber test space, 2. Climatization unit, including fan, heating, cooling and humidification, 3. Test plane with samples, 4. Temperature/ humidity sen

22、sor for regulation, 5. Insulated walls/ lids, 6. Diffusors for improvedair distribution, 7. Fresh air inlet/ bleed, 8. Rain rig with nozzles and motor for swaying mode, 9. Gutter, 10. Control/ steering/ recording unit, 11. Position for monitoring/ calibration of climate with independent temperature/

23、 humidity sensor.图 1 环境试验箱的图示,配备了进行本文所述的试验程序所需的功能:1.试验空间; 2.环境系统,包括风扇、加热器、冷却器和加湿器;3.放置试样的平面;4.温湿传感器(调节用);5. 隔热壁 /盖; 6. 空气扩散器(改善空气分布);7.新鲜空气进气口;8. 带喷头和摇摆模式驱动马达的喷洒器; 9. 排水口; 10.控制 /操作 /记录系统;11. 带独立温室感应器的环境监控/校正位置。3.1CLIMATE CONTROL环境控制Thehumidity and temperature levels ofthechamber during the test cyc

24、leshall be continuously monitored . Thesensors should reflect the climate conditionsin the test plane (Fig. 1,item 4). Themean value of the constanttemperature/ relative humidity climate conditions must be within0.4 C and2% relative humidity (RH) respectivelyvs. the real, set value, i.e. these are t

25、he max tolerable mean offsets caused by the sum of calibration errors.At annualcalibration this degree of accuracy must be fulfilled for the following three constant conditions: 25C, 95% RH, 50 C,95% RH and 50 C, 70% RH. At bimonthly control, during normal operation, this accuracy should be fulfille

26、d at theconstant climate conditions (50 C, 70% RH) during a work-day cycle.1 中第试验过程中应连续不断地监控试验箱的湿度和温度水平。传感器会反映试验“平面”上的环境(如图4 项)。恒定温度 /相对湿度的均值必须在0.4 C 范围内,相对湿度(RH )在 2%,分别对应实际值、设定值,这些就是由于累积的校正误差造成的平均偏移值的最大允许范围。在年度校正过程中,这一精确度必须得到满足,以保证以下三项恒定条件:25C, 95% RH, 50C, 95% RH以及 50 C, 70% RH 。在进行两月一次的正常控制时,工作日

27、循环中的恒定环境条件(50 C, 70% RH )应能到达这一精度。The maximum allowed short-term fluctuations in relative humidity overlaid on the calibrated mean value is3% RH,which implies a maximum allowed short-term temperature fluctuation of 0.6 C. Figure 2is exemplifying therequirement on relative humidity.叠加到校正平均值的相对湿度短期波动最

28、大范围是3% RH 。这意味着短期温度波动的最大范围只能是0.6 C。图 2 举例说明了相对湿度的要求。Actual mean RH valueActual fluctuation around mean RH value相对湿度实际均值相对湿度均值上下的实际波动Set RH value相对湿度设定值Fig. 2 Accuracy requirement on humidity deviations from set value图 2 湿度Trueness:偏差离设定Max值的allowed精确度要absolute求Precision: Max allowed variationcalibra

29、tion error: 2% RHaround actual mean value:3% RHThe chamber controlling software/ hardware must be designed so that the relative h midity may be changed linearly真实:最大允许的校正误差绝对精确度:实际均值上下允许的最大变with time as depicted in the illustrated test conditions, see Figure 5. In the 2-stage ramping from a wet cham

30、ber at 25值: 20%RHat 50 C, 70% RH, the first heating动范围是stage: 3%to 40RH C should be reached within 30 minutes2 C to humid conditionswithout sample drying, which is secured by a nominal relative humidity setting to 95% RH. The second 2 h ramp mustreach the stipulated final 50C, 70% RH at the end of t

31、he ramp.控制试验箱的软件 /硬件必须设计成能使相对湿度随时间呈线性变化,如图5 所示。从试验箱温度为252C的湿润状态到50 C, 70%RH 的湿润状态需经过两个阶段。第一阶段应通过将相对湿度读数设定到95%RH ,以保证温度在30 分钟内达到 40 C 而试样不干燥。第二阶段为两小时,必须在结束前达到规定的50 C, 70%RH 。NOTE:For each new exposure situation this condition must be verified by an independent monitoring device (paragraph 2.5) with t

32、he sensor positioned among the actual test objects in their actual average plane of exposure (Fig. 1 Item 11). For monitoring : Deploy the sensor directly after the last spray event of the work-day wet phase.注意:每次曝露的条件必须经过独立监控设备验证(见第 2.5段),也就是实际试验物体所在的曝露平面之间的传感器(如图 1,第 11项)。在工作日湿润阶段的最后一次喷洒后直接调节传感器来进

33、行监控。In automated testing, forced cooling is necessary when proceeding from 50 C, 70 % RH controlled, constant conditions to macro-wet conditions at 25 C. The chamber must achieve a cooling from 50 C to 30 C within 30 minutes with the targeted 25 C met within 1 hour. If spraying is applied manually,

34、then cooling the samples by lettingthe chamber be open with test objects kept wet may provide an option that does not require the use of a built-incoolingunit.It must be verifiedby temperature monitoringthat coolingrequirements are fulfilledunder suchconditions for the actual chamber type and test s

35、pecimen load.在自动试验过程中,要使试验箱从受控恒定条件50 C, 70 % RH变化到 25 C 下非常湿的条件,需要进行强制冷却。试验箱必须在30 分钟内从50 C 冷却到30 C,然后在1 小时内到达目标温度25 C。如果是手动喷洒,可以打开试验箱同时让试样保持湿润,这样就不必使用内置冷却系统。在这种条件下要满足该类试验箱和试样负荷的冷却要求,必须通过温度监控保证。3.2RECOMMENDATIONS ON TEST CHAMBER FUNCTIONALITY关于试验箱功能的建议In order to meet the temperature and humidity acc

36、uracy requirements throughout the test area, the chamber should be equipped with means to provide well distributed circulation of conditioned air (meaning a local air velocity of at leasta few cm/s over all parts of the test area, - Fig. 1 is exemplifyingsuch a condition) . Sufficientinsulationof th

37、echamber walls and lids is required in order to avoid excessive condensation on these surfaces. The more efficient air circulation, the less insulation is required.为了在整个试验过程中满足温度和湿度的精确度要求,试验箱应配备能使经调节温湿度、空气流动性好的装置(试验区域内各部分的内部气流速度至少是若干厘米 /秒 -例如图 1。)试验箱的四壁和盖板要求得到有效隔热,以避免这些表面出现过渡冷凝。空气流动性越好,隔热需求越少。Wall h

38、eating should be avoided, due to that heating by radiation tends to keep test object close to the chamber walls locally too dry to be within humidity specification (or a screen shall be installed to avoid such an effect). Provided theinternal air circulation is efficient, wall heating is not require

39、d.The chamber air must be continuously renewed by apurge of not less than32depleted under any exposure conditions.Fresh air can be added dry from a compressed source or taken from ambientconditions, unless significantly polluted ( 50 ppb SO2).由于热量辐射会使靠近箱壁的试样过度干燥,达不到湿度要求,因此应尽量避免试验箱壁受热(或者添加遮挡板来避免受热)。如

40、果内部空气流动良好,就不必进行箱壁加热。应配备1 m3/ h 每 m2 的空气净化器使试验区域内的空气不断更新(例如图1 第 7项)。这是为了保持CO2 水平,避免其在曝露条件下被耗尽。干燥的新鲜空气可以由压缩机提供,或使用室内的空气(除非空气被严重污染( 50 ppb SO 2)。3.3EXPOSURE TO SALT SOLUTION曝露到盐溶液中3.3.1For a fullyautomated procedure , the chamber shall be equipped with a spray devicecapable of producing a finely distri

41、buted, uniform spray falling on the test objects. The most reliable way ofreceiving a fairly uniform downfall is by installing a moving spray device, like the swaying rail with overlapping nozzles, depicted in Fig. 3. The spraying device shall be made of corrosion resistance materials. Plastic is re

42、commended.3.3.1对于全自动的试验,试验箱内应配备喷洒装置,能使溶液得到妥善分配,均匀喷洒到试样上。最能有效使溶液均匀喷洒的方法是安装一套可移动的喷洒装置,如带交叉喷头的摇摆轨道,如图3 所示。喷洒装置应由耐腐蚀材料制成,最好是塑料。Fig. 3 Example of spray rig for obtaining uniform salt solution downfall.图 3 使盐溶液均匀喷洒的喷洒装置示例2A target average precipitation rate distributed over the workday 6 h wet period of t

43、his test procedure period is 5 L/m,and shall not exceed 10 L/m2 . For any local position the total precipitation over the 6 h period must not be lowerthan 3 L/m 2 and not exceed 15 L/m 2. Suggested nozzles type: Spraying Systems Uni Jet 800050VP.Mount thenozzles on a supporting tube 50-60 cm apart a

44、nd about 1 m above the test objects.The nozzles shall be adjusted sothat the fan plumes are in line with the tube/ supporting rail. An individual filter at each nozzle is strongly recommended to avoid any contaminations in the tiny slots. These low-cost plastic nozzles have a reliable function,but m

45、ust be inspected in microscope at delivery in order to discard such with defect slot cuts. Stainless nozzles, even in 316 alloy, will be impaired by corrosion under the actual test conditions. Atomizing salt-spray nozzles should not be used, since they generate a too low precipitation rate to give s

46、ufficient leaching effect on the test objects. Achieving a uniform downfall with these types of nozzles can be difficult.在本试验的工作日的6 小时加湿阶段,平均喷洒密度的目标值为5 L/m 2,且不能超过10 L/m 2 。在 6小时周期内,箱内任何位置的喷洒密度都必须不低于3 L/m 2,不高于 15 L/m 2 。建议喷头类型:UniJet 800050VP 喷洒装置。将喷头装在支承管上,相隔56-60cm ,处于试样上方1 米左右。调整喷头,使扇叶与支承管/支承轨成一

47、直线。强烈建议在给每个喷头装上过滤器,以避免小槽中的污染物。虽然这些喷头价格低廉、功能可靠,但是发货时还须经过显微镜检验,以淘汰那些小槽切割不良的喷头。不锈钢喷头,就算是用316合金制成的,在也会在实际试验条件下受到腐蚀而损坏。雾化盐雾喷头喷洒密度过低,无法为试样起到有效的过滤作用,故不宜使用。这几类喷头喷洒都不均匀。3.3.2An automated spray-rig is allowed to be separated from the humidity chamber, i.e. the test objects are movedbetween two units on a work

48、-day basis.3.3.2自动喷洒装置可从加湿箱中拆出来。也就是说,试样在一个工作日内在两套设备之间移动。3.3.3If there is no possibilityto use an automated device for spraying, a manual sprayingof the test object isallowed, either in or outside the test cabinet, provided: 1. The minimum precipitation rate of 5 L/m2 per 6 hwet session is fulfilled,

49、 2. The spraying events are distributed over the 6 h period, so that the test object arekept constantly wet, and 3. The temperature requirement is fulfilled.3.3.3如果不能采用自动喷洒装置,可采用手动喷洒,在箱内箱外皆可,条件是:1. 在6 小时加湿阶段完成前,喷洒密度至少为5 L/m 2。 2.喷洒将分布在 6小时周期内,以使试样保持湿润;并且;3. 保持要求的温度。NOTE:Salt solution sprayed onto te

50、st objects must not be reused.注意:喷洒到试样上的盐溶液不得重复使用。4.0Sample preparation试样准备Sample preparation before exposure, the sample orientation during exposure and the evaluation after exposure are usually stipulated in the engineering test standards addressing this test procedure.曝露前试样准备,曝露期间的朝向和曝露后的评估方法一般会在

51、本试验程序相关的工程试验标准中关于有所规定。4.1Painted and scribed panels: The test is optimizedfor exposing scribes in horizontal position on panelsoriented4.14.2Component parts are to be in vehicle orientation position if at all possible.The salt solution spray shouldreach the areas of interest.4.2如果可能,零部件应尽量按照汽车朝向放置,并

52、使盐溶液能淋到达目标区域。4.3Interested parties should agree on the location within the components where the corrosion is to be observed.4.3相关各方需商定零部件上将出现腐蚀的位置。4.4Interested parties should agree to any pre-conditioning, masking of edges, pre-testing, cleaning, or any othersample preparations.4.4相关各方需商定预处理、要遮盖的边缘

53、、预测试、清洁或其他试样准备工作。4.5Interested parties should agree to any photographic details throughout the test and the areas to be examinedand any assessments that are required.4.5相关各方需商定试验过程的具体细节、检测的区域以及要求的评估。5.0OPERATION 操作5.1BEFORE TEST START试验开始之前Preparetest objects accordingto the instructions in paragrap

54、h 4, which mayinclude additional procedures, likepreconditioning in other test equipments (e.g. heat treatment).按照第4 段的说明准备试样,也许将包括附加步骤,如在其他试验设备中进行预处理(比如热处理)。5.1.1 Test object orientation:Components or test objects in the chamber shall be placed on/ mounted to non-corrosive surfaces in the appropria

55、te agreed upon position.If the item is flat the test surface shall be within an15-20 angle from vertical.Note that the inclination determines the amount of wetness collected on the paneland hence, the salt load when this film is subjected to climate control, which in turn influences the test result.5.1.1试样的朝向:试验箱中的零部件或试样应按照商定的朝向,放置或固定在防腐蚀的表面上。如果试样是平的,那么试验

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论