版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
ProtectITMultifunctionProtectionandSwitchbayControlUnitREF542plusTableofContents1General(42Functions(82.1Configuration(82.2Operation(102.3Measurement(122.4Protection(132.5Control(142.6Eventrecording(142.7Faultrecording(152.8Realtimeclock(162.9Processinterface(163Diagnosisandmonitoring(194Analogoutput(205Communication(216Housing(237Mechanicaldesign(267.1REF542plusstandardcaseversion:(267.2REF542pluswidecaseversion:(267.3Analoginputs(268Listoftheprotectionfunctions(279Technicaldata(329.1Analoginputchannels(329.2Binaryinputsandoutputs(339.3Interfaces(349.4Analogoutputboard(optional(349.5Communication(optional(349.6Powersupply(359.7Environmentalconditions(359.8Degreeofprotectionbyenclosure(3610Typetest(3710.1Protectionfunction(3710.2Electromagneticcompatibility(3810.3Insulationresistance(4210.4Mechanicalrobustness(4210.5Climaticconditions(4211ConnectionDiagram(4311.1ConnectorPlate(4311.2HMIControlUnit(4411.3REF542pluswithmechanicalbinaryI/O(4511.4REF542pluswithsolidstatebinaryI/O(4811.5REF542pluswithmechanicalbinaryI/O(version2(5111.6Analoginputboardversions(521GeneralTheREF542plusMultifunctionProtectionandSwitchbayControlUnitisthefurtherdevelopmentoftheformerREF542unit.Likeitspredecessor,itfeaturesthefollowingfunctions:ProtectionMeasurementControlMonitoringAllfunctionsmentionedaboveandpowerqualityfunctionsareintegratedinaprogrammableenvironment.Theexceptionalflexibilityandscalabilityofthesenewgenerationdevicesleadtoasmartandcleansolutionwherethetraditionalapproachwouldbeineffectiveandexpensive.ThefollowingfiguresshowexamplesoftheREF542plusinstallationinseveralswitchboards.Figure1:REF542plusinstalledingasinsulatedswitchboards(GISFigure2:REF542plusinstalledinanairinsulatedswitchboard(AISTheREF542plusisbasedonareal-timemicroprocessorsystem.ThemeasurementandprotectionfunctionsareexecutedbyaDigitalSignalProcessor(DSP,whileaMicroController(MCisexecutingthecontrolfunctions.Duetothistaskseparationthereisnoimpactbetweenthestartandthetripbehavioroftheimplementedprotectionscheme,shouldthecontrolschemebemodified.TheCommunicationProcessor(CPisneededforconnectiontoastationautomationsystem.AblockdiagramoftheREF542plusisshowninfigure3.Figure3:REF542plusBlockdiagramREF542plus,asshowninfigure3,consistsoftwoparts,aCentralUnitandaseparateHumanMachineInterface(HMI.TheCentralUnitcontainsthepowersupply,processorandanalogandbinaryInputandOutput(I/Omodules,aswellasoptionalmodulesforsupplementaryfunctions.TheHMIControlUnitisastand-aloneunitwithitsownpowersupply.ItcanbeinstalledontheLowVoltage(LVcompartmentdoororinadedicatedcompartmentclosetotheCentralUnit.TheHMIisnormallyusedtosettheprotectionparametersandtolocallyoperatetheswitchingdevicesintheswitchbay.TheHMIisconnectedtotheCentralUnitbyashielded,isolatedtwistedpairaccordingtotheRS485interface.Figure4showsaninstallationoftheCentralUnitandtheHMIControlUnitintheLVcompartmentofaswitchboardfortheswitchbay.Figure4:MountingoftheCentralUnitintheLVcompartmentandtheHMIonthedoorTheHMIControlUnit,asshowninfigure5,featuresaback-illuminatedLiquidCrystalDisplay(LCD,eightpushbuttons,severalLEDsandanelectronickeyinterface.Thelanguageofthedisplaycanbeselectedviatherelatedconfigurationsoftwaretool,whichisalsousedtodefinetheprotectionandthecontrolscheme.Figure5:TheHMIControlUnitThelefthalfoftheLCDdisplayisreservedfortheSingleLinediagram.Therighthalfisusedtodisplaytheappropriatemenuorsubmenuasdeterminedbytheuser.Twodifferentelectronickeyswithdifferentaccessrightsareavailable.Eachofthekeysareprogrammedtopermiteither:protectionfunctionsparameterizationofthemodeselectionofthecontrolfunctionsThreefreelyprogrammableLEDbarshavebeenprovidedonthefrontoftheHMIControlUnit.EachLEDbarconsistsoftengreenandtworedLEDsandisuserconfigurabletodisplayanyrequiredmeasurementvalue.TheredLEDsareusedtoindicatevaluesabovetheratedvalue.ThefunctionsoftheREF542pluscanbetailoredtothesystemrequirementsviaauser-specificconfiguration.Theuser-specificconfigurationisloadedduringcommissioning.Forthatpurposetheconfigurationcomputer,normallyapersonalcomputer(notebookrunningWindowsNT,isconnectedtotheopticalinterfaceonthefrontsideoftheHMIControlUnit.TheinterfaceofthemultifunctionalunitREF542plustotheMediumVoltage(MVprimaryprocessisasfollows:AnaloginputstomeasurecurrentandvoltagesignalsfrominstrumenttransformersornonconventionalsensorsBinaryinputswithopticalcouplersforthegalvanicseparationoftheexternalsignalstobeprocessed;Binaryoutputswithconventionalmechanicalrelaysorstaticoutputsforthecontrolofswitchingdevices;Optionalfourchannelanalogoutputs0to20mAor4to20mAOptionalconnectiontoABBorthirdpartystationautomationsystem.REF542plusisacertifiedproductforcompliancetotheIndustrialITarchitectureconceptofABB.IndustrialITproductscanbeeffectivelycombinedtogetherintovalue-addedsystemsandsolutionsina“Plug&Produce”manner.Complianceaccordingto“Level0:Information”ensuresthatallrelevantproductdocumentation–includingtheoperationmanual,instructionsforinstallationandmaintenance,electricalandmechanicaldrawings,testreportsandspecificorderinformation-isonlineavailable,inelectronicformat,foraccessviasoftwareproductsandsystemsbasedontheABBAspectIntegratorPlatform.2FunctionsREF542plusMultifunctionProtectionandSwitchbayControlUnitintegratesallthesecondaryfunctionsinasingleunit.Thismultifunctionalunitalsofeaturesaself-monitoringfunction.Allfunctionsaredesignedasfreelyconfigurablesoftwaremodules.Therefore,awiderangeofoperationrequirementsinMVstationscanbemetwithoutanyproblems.TheversatilityofthesoftwaremakesitpossibletousetheREF542plusoneveryswitchboardindependentonthespecificapplicationrequired.2.1ConfigurationEachapplicationforprotectionandcontrolcaneasilybeconfiguredbysoftwarefunctionmodules,whichmakearbitrarydefinitionofthefollowingfeaturesaspartofthesecondarysystempossible:LED's(meaningandcolorsforlocalindicationSingleLinediagramtoshowthestatusofswitchingdevicesProtectionschemesControlschemesInterlockingschemesAutomationsequencesAllfunctionsintheswitchbaycanbespecifiedincollaborationwithABB.Theresultoftheconfigurationissavedanddeliveredtogetherwiththeswitchboardtotheusers.Byusingthe"FUnctionalblockProgrammingLanguage”(FUPLAtheREF542plusMultifunctionProtectionandSwitchbayControlUnitoffersengineers,especiallythosewhoarenotsoftwareexperts,theopportunityofeasilyupdatingtheoperationandhandlingoftheswitchbay.WithREF542plustheuserhasthebenefitofasecondarysystemthatisfullyintegratedinatrueprogrammablecontroller.Thisflexibilityisveryadvantageousfordefiningcontrolfunctionsforautomationsequences,whichcan,forexample,includetheinterlockingoftheswitchingdevices,blockingthereleaseofspecificprotectionfunctions,aswellasstartingswitchingsequences.REF542plusmultifunctionalunitprovidesawiderangeoflogicalfunctionssothateachrequiredcontrolschemescanbeconfigured.Therangeoflogicalfunctionsincludes:ANDlogicgateNANDlogicgateORlogicgateNORlogicgateXORlogicgateBistableandmonostableflipflopCountersTimersPulsegeneratorsMemoriesSimilartothefreedefinitionofthecontrolscheme,eachrequiredprotectionschemecanbeconfiguredbythecombinationoftheavailableprotectionfunctionmodules.Forexample,thefollowingprotectionfunctionsareavailable:DefinitetimeovercurrentprotectionInversetimeovercurrentprotectionDirectionalovercurrentprotectionUnder-orovervoltageprotectionDistanceprotectionDifferentialprotectionfortransformerandmotorThermalprotectionforcable,transformerandmotorReversepowerprotectionSynchronismcheckNoteThespecificsoftwareconfigurationoftherequiredprotectionschemecanonlybecarriedoutin-houseatABB.TheprotectionschemeparameterscanbechangedviatheHMIControlUnitwithoutusingapersonalcomputer.AdditionalfunctionscanbeexcutedwithapersonalcomputerrunningtheconfigurationsoftwareandconnectedtotheopticalinterfaceonthefrontoftheHMIunit.Theseadditionalfunctionsare:Parameterizationoftheprotectionscheme,Read-outofthecurrentmeasurementvalues,Read-outofthestatusofthebinaryinputsandoutputs,Read-outofthefaultrecorderandViewingoftheFUPLAlogicI/Ostates2.2OperationAwiderangeoffunctionscanbecontrolledandoperatedusingthesimple,user-friendlyinterfaceontheHMIControlUnit.Thisuser-friendlyinterfaceisshowninthefollowingfigure.Figure6:HMIasControlUnitTheHMIconsistsofthefollowingfeatures:Theback-illuminatedLCDdisplayoftheHMIprovidesagraphicaldisplayoftheswitchingdevicesintheswitchbaycontrolledbytheREF542plus.Theintensityandthedurationoftheilluminationcanbesetasrequired.TheSingleLinediagramshowsthecurrentstatusofalltheswitchingdevices.TherighthalfoftheLCDdisplayisforplaintext,suchasmeasurementvalues,mainmenuandsubmenusdescriptions,protectionsignalsandeventrecording.OntheLCDdisplay,thefollowingcanbeshown:Uptoeightswitchingdeviceicons(whenthebinaryI/Oboardswithmechanicalrelaysareused,amaximumofsevenswitchingdevicescanbecontrolledVariousiconsformotors,transformers,sensors,transducersAmaximumof40individuallines.FoursystemLEDs,describeinthefollowingchapters,indicatethestatusoftheREF542plus.OntheHMIfrontpanel,theoperationalstatusiscalled'Ready'andisdisplayedbyagreenLED.TheunitisnotoperationalwhenthisLEDisoff,andthisoccursforexampleduringthedownloadingoftheconfigurationfortheoperationoftheswitchbayorifafaultconditionisdetectedintheCentralUnit.OntheHMIfrontpanel,thiscommunicationstatusiscalled'NetworkCommunication'.IftheREF542plusistobeconnectedtoastationautomationsystem,theappropriatecommunicationsboardisrequired.InthiscaseagreenLEDisusedtoindicatethecorrectoperationalstatusofthisoptionalboard.TheLEDcolorchangestoredifacommunicationfailurehasoccurred.Severalarbitraryalarmconditionscanbedefinedandconfiguredbytheuser.Ifoneoftheseconditionsisfulfilled,theredLEDwillbeon.TheLEDisgreenifnointerlockingconditionshavebeenviolated.Incaseofaswitchingaction,whichviolatestheinterlockconditionssuchasswitchingadisconnectorintheclosedconditionoftheCircuitBreaker(CB,thecolorwillchangetemporarilytored.Eightfreelyprogrammable,threecolorLED'sareprovidedforlocalindication.ThenumberofLEDdisplayoptionscanbequadrupledthroughthemenustructure.Asaresult,atotalof32indicationoptionsareavailableforstatusindicationregardingprotection,control,monitoringandsupervisionfunctions.ThreefreelyprogrammableLEDbarsareprovidedforshowingthemeasurementvalues.TheLEDbarsareusedtodisplayarbitrarymeasurementvaluesasrequired.EachbarconsistsoftengreenandtworedLEDs.ThenominalvaluesofeachLEDbar,whichcorrespondstothetengreenLEDsaredefinedbytheconfigurationsoftware.Ifthemeasurementvaluesarehigherthantheratedvalues,theredLEDswillgetsilluminatedindicatinganoverloadsituation.Thecontrolpushbuttonsareusedforoperationoftheswitchingdevicesduringlocalcontrol.Atotalofeightpushbuttonsareavailable,fourforcommandingtheprimaryequipmentandfourforbrowsingthedisplay.TheemergencypushbuttoncanbeconfiguredintheFUPLAtoopenthecircuitbreakerwhenpressedsimultaneouslywiththenormalopenpushbutton.Twodifferentelectronickeysareprovided.Onekeycanonlybeusedfortheprotectionschemeparametrization.Theotheroneisforcontrolmodesselection:local,remoteorlocal/remote.Byusingthesetwokeysacertainseparationbetweenprotectionandcontroloperationcanbeachieved.Ifrequiredageneralkeythatpermitsaccesstobothmodesisprovided.ThesensorforrecognizingwhichelectronickeyhasbeenusedislocatedonthefrontpaneloftheHMIControlUnit.2.3MeasurementREF542pluscanhaveamaximumof8analogueinputchannelsformeasuringcurrentandvoltagesignals.Thesechannelsareorganizedintothreegroups.Group1andgroup2havetobehomogeneous,thatmeanstheycanmeasure3currentsor3voltages.Forexample,measurementof1currentand2voltagesisnotallowed.Group3cangetanytypeofsignals:2currents,2voltages,1currentand1voltage,etc.Channel8inthecurrentREF542plusreleasecanbeusedformeasurementpurposesonly(noprotection.REF542plusanalogueinputsareveryflexible,asthisflexibilityisneededtosupportalltheprotectionfunctionsoftheunititself.Group1andgroup2canbeusedforhomogeneouscurrentorvoltagemeasurementsbothfrominstrumenttransformersandnonconventionalsensors.Group3canbeusedinaheterogeneousway,aswellwithinstrumenttransformersasalsowithsensors.Channel7ingroup3canbeusedforearthfaultcurrentwithcurrenttransformertypeinput;orforthesynchronismcheckfunctionwithvoltagetransformertypeinput.Themostcommonconfigurationusesthreecurrentandthreevoltageinputsandoneearthfaultcurrentinput.Allvaluesareshownonthedisplayasprimaryvalues.Thevaluesregisteredoveranextendedtimeperiod,forexampleenergy,numberofCBoperations,maximumandmeasurementvaluesarepermanentlysaved.Evenafterpowerinterruptionsthisdataisstillavailable.Usingthiscommonconfiguration,thefollowingmeasuredvaluesaredisplayed:Linecurrents,threephasesPhasevoltages,threephasesEarthcurrentorresidualvoltageFrequencyFromtheabovemeasuredquantitiesthefollowingvaluescanbecalculated:Linevoltages,threephasesEarthcurrentorresidualvoltageAveragevalue/maximumvaluecurrent,three-phase(determinedoverseveralminutesApparent,activeandreactivepowerPowerfactorActiveandreactiveenergyMoreover,thefollowingquantitiesformonitoringpurposescanbeprovided:OperatinghoursSwitchingcyclesTotalswitchedcurrentsMeteringpulsesfromanexternalmeteringdevice(upto102.4ProtectionTheREF542plusoffersawiderangeoffunctionsforprotection.Asmentionedbefore,awiderangeofprotectionschemesfortheprotectionofseveralsystemcomponentscanbeconfigured.Theavailableprotectionfunctionscanbecombinedtogethertoformtherequiredprotectionscheme.Figure7showsanexampleofaconfiguredprotectionscheme.Figure7:FUPLAprotectionscheme2.5ControlTheREF542pluspermitsconvenientlocaloperationwithfullinterlockingagainstswitchingerrors.TheswitchpositionofthevariousswitchingdevicesintheswitchbaycanbeshownontheLCDdisplayoftheHMIControlUnit.Iflocalcontrolmodeisselected,switchingactionscanbeinputlocallyusingthecontrolpushbuttonsontheHMIControlUnit.Switchingtoanothercontrolmodecanonlybeachievedbyusingthecorrectelectronickey.Inremotecontrolmode,onlyswitchingactionsfromaremotecontrolunitlikeastationautomationsystemarefeasible.Aspecialcontrolmode,LocalandRemote,isprovidedforuserswhowanttoperformsimultaneousLocalandRemoteswitching.Interlockingbetweentheswitchbaysconnectedtothesamebusbarsystemcanalsobetakenintoaccount.Thisrequirestheavailabilityofstatusinformationoftheswitchingdevicestoandfromotherswitchbays.Thestatusinformationmustbeprovidedeitherbyaconventional,hardwiredringbussystemorbythemoresophisticatedABBstationautomationsystem.Figure8showsanexampleofaconfiguredcontrolschemeoftheCB.Figure8:FUPLAcontrolscheme2.6EventrecordingThelast30recordedeventscanbeshownlocallyontheLCDdisplayoftheHMIunit.Theeventsaremostlyrelatedtoprotectionactivities.Aswellasdisplayingtheeventname,additionalinformationabouttheevent,time,dateandtheRMSvalueoftheshortcircuitcurrentswitchedoffbytheCBareprovided.Eacheventisstampedwiththetimeanddate.ThetimeistakenfromtheinternalclockontheREF542plus,whichcanbesynchronizedbythestationautomationsystem.Inthenextfigure,alistofrecordedeventsisshown.Figure9:EventlistontheLCDoftheHMI2.7FaultrecordingThemultifunctionalunitREF542plusisequippedwithafaultrecordermodule,whichrecordandencodeanalogandbinarydata.Thenumberofrecordeddatachannelsdependsontheinitialconfiguration.Uptosevensignalsoftheanalogchannelsand32binarysignalscanberecorded.Theanaloginputsignalsarerecordedwithasamplingrateof1.2kHzforaperiodofatleast1-secondandforamaximumof5seconds.Therecordingtimeisacombinationofpre-andpostfaulttime.Therecordsaresavedusingatypicalringbufferprocess,i.e.theoldestfaultrecordisalwaysoverwrittenwithanewone.Thenumberofsavedfaultrecordsdependsontherecordtime.Forexample,amaximumof5faultrecordscanbesavedwitharecordingtimeof1s.Faultrecordscanbeexportedandconvertedbytheconfigurationsoftware.Thetransferoffaultrecordscanbedonealsoviatheinterbay.Figure10showsarecordofacrosscountryfaultinanearthfaultcompensatedMVsystemstartingwiththeearthfault.Figure10:RecordofacrosscountryfaultinanMVsystem2.8RealtimeclockREF542plusisequippedwithaninternalrealtimeclockwhichisusedtotimestampevents.Theinternalclockisbufferedbyaspecialsupercapacitor.IncaseofDCpowersupplyfailure,thestoredelectricalenergyinthecapacitorensurescontinuedoperationoftheinternalclockforatleastanothertwohours.ThedateandtimeoftheclockcanbesetviatheHMIControlUnit.REF542plusinternalclockcanbekeptsynchronizedwithanexternalclockindifferentways.Whenconnectedtoastationautomationsystem,REF542plusissynchronizedviainterbaybususingthefacilitiesoftheusedprotocol.Ifbetteraccuracyisrequired,REF542pluscanbesynchronizedusingthededicatedIRIG-BopticalinputportandaGPSmasterclock.Figure11:SynchronizationoftheinternalclockbyaGPSmasterclock2.9ProcessinterfaceTheREF542plusMultifunctionProtectionandSwitchbayControlUnitisdesignedforconnectiontononconventionalcurrentandvoltagesensorsaswellastoinstrumentstransformers.Thankstotheirlinearcharacteristic,moderncurrentandvoltagesensorsprovidegreateraccuracyandreliabilityinsignalmeasurement.Comparedtoinstrumenttransformers,thenewsensorshavethefollowingadvantages:HighaccuracyCompactdimensionsWidedynamicrangeEasyintegrationintheswitchboardThecurrentsensorisbasedontheprincipleoftheRogowskicoilandconsistsofasingleair-coredcoil.Duetothelackofanironcore,thesaturationeffectsofconventionalcurrenttransformersdonotexistanymore.Currentsensorsarethuswellsuitedforthedeploymentofdistanceprotectionanddifferentialprotectionfunctions.Thecurrentsensormeasuresthecurrentvalueusingavoltagesignalthatisproportionaltothederivativeoftheprimarycurrentbeingmeasured.ThenumericalintegrationofthesignalisperformedusingtheDSPintheREF542plusunit.Thecurrentsensorscoverarangefrom0.5to2.0oftheratedcurrent.The80Acurrentsensorsareforexampleverysuitableforapplicationsbetweenacurrentrangeof40Ato160A.Thevoltagesensorisbasedontheprincipleoftheresistivedividerfromwhichthesignalisobtainedandisofatypethatcannotbesaturated.Therefore,thevoltagesensorislinearthroughoutthemeasuringrange.Theoutputsignalisavoltagethatisdirectlyproportionaltotheprimaryvoltage.Thenextfiguresshowsthecombinedsensors.Thecurrentandvoltagesensorsareencapsulatedintoasingleresinunit,andthatisthereasonwhytheyarereferredascombinedorcombisensors.Figure12:CombinedsensorAcapacitivedividerisincorporatedinthecombinedsensortoprovidethepowersupplyforvoltagepresenceindicatorlamps.TheoutputsignalsofthecurrentandvoltagesensorsareconnecteddirectlytotheCentralUnitoftheREF542plus,theydonotrequireadaptationtransformers.Byusingeithermodernsensorsorconventionalmeasurementtransformers,theaccuracyclass1canbefulfilled,onconditionthatthecurrentandvoltagemeasuringvaluesareintherangeofthecorrespondingratedvalues.Theprimaryswitchingdevicesaremonitoredeitherthroughtheauxiliarycontactsorthroughtherelatedsensors,whichprovidethestatusinformationofalltheswitchingcompartmentsintheswitchbay.Besidesthat,signalscomingfromauxiliarycomponentsarealsomonitored.Consequently,atthisinterfacethefollowingactionsareachieved:ControlandinterlockingoftheprimaryswitchingdeviceintheswitchbayControltheCBs,disconnectors,earthingswitchesSupervisionofthespringstatus,ofthecontinuityofCBopencoil,thestatusoftheswitchingdevice.Providingoutputpulsesignalsforexternalenergycountingsystems.ControlofthedisconnectorsdrivemotorsProvidingtheinformationregardinginternalfailure(watchdog.Theinputsofthebinarysignalsareisolatedbyanopto-coupler.Inmostapplications,binaryoutputsareimplementedwithmechanicalrelays.However,inhighlevelapplications,likeaswitchboardinwhichmotorsaredirectlydriven,staticpoweroutputsarerequired.Amaximumof3binaryI/Oboardscanbeinstalled.3DiagnosisandmonitoringTheREF542plusmonitorscontinuoslytheconditionofthesystem,includingtheswitchingdevices.Maintenancerequirementscanthusbeadaptedtotherealsystemconditioninordertoreducedowntimes.ThefollowingtableshowstheparametersmonitoredbytheREF542plus.Alltheparameterscanalsobetransmittedtoacentralcontrolsystemwheretheyareanalyzedandprocessed,sothatthediagnosticsystemscanbeprovidedwithdataforreliabilitycalculationtopredicttheremainingservicelifeandmaintenanceactions.TypeParametersmonitoredSoftwareDiagnosticofREF542plusunitElectricalAuxiliaryvoltagecircuitsPowersupplytomotoroperatorsoftheswitchingdeviceContinuityofwindingsoftheCBopeningcoilMechanicalcomponentsStateofCBoperatingmechanismspringsNumberofmechanicaloperationsGaspressurerespectivelydensityTimeCountofhourstheswitchingdeviceboardinoperation.Contactswitchingtime(fromclosedtoopenusingevents4AnalogoutputAnoptionalanalogoutputmodulewithfourconfigurableoutputscanbeinsertedintheCentralUnit.Theoutputsignalofthismodulecanbesetintherangefrom0to20mAor4to20mA.Eachofthefourchannelscanbeindependentlyactivatedandparameterizedbytheconfigurationsoftware.Thefollowinganalogoutputquantitiesareselectable:AllvoltagequantitiesdirectlyfromtheanaloginputsAllcurrentquantitiesdirectlyfromtheanaloginputsCalculatedresidualcurrentsCalculatedresidualvoltagesCalculatedapparent,activeandreactivepowerCalculatedpowerfactor5CommunicationAnoptionalcommunicationsboardisprovidedforcommunicationwithastationautomationsystem.ThiscanbeanABBstationautomationsystemorathirdpartysystem.WhenusingtheABBstationautomationsystem,alloftheinformationprovidedbytheREF542pluscanbecompletelyaccessedsothatthefollowingcentralizedremotefunctionscanbeimplemented:RemotemonitoringRemotecontrolRemotesettingofprotectionparametersRemotemeasurementEventsrecordingMonitoringofallswitchingdeviceAnalyzeoffaultrecorderdataThefollowingprotocolsforconnectiontoABBstationautomationsystemareavailable:SPA-busLON-busaccordingtoABBLonApplicationGuide(LAG1.4definitionsThesoftwarelibraryLIB542isavailabletointerfacetheREF542plusunitintheABBMicroScadastationautomation.Figure13:ConnectionoftheRE542plusinanABBstationautomationsystemThefollowingprotocolsallowREF542plustobeconnectedtoanythirdpartyautomationsystem:IEC60870-5-103standardincludingtheextensionforcontrolfunctionsaccordingtoVDEW(VereinigungDeutscherElektrizitätswerke=associationofGermanutilitiesDualMODBUSRTU6HousingTheREF542plushousingfortheCentralUnitismadefromsheetaluminium.ItsexteriorischromatizedbothtoprotectthehousingagainstcorrosionandtogaintheshieldingagainstEMCdisturbances.TheCentralUnitallowsasafeintegrationintoaswitchboard.Astandardandawidecaseversion,asshowninthefollowingfiguresareavailable.Inthestandardcaseversion,twobinaryI/Oboardsandanoptionalcommunicationsboardcanbeused.ThewidecaseversioncontainsanadditionalbinaryI/Oboardandtheanalogoutputboard.Figure14:DimensionofthestandardcaseversionFigure15:DimensionofthewidecaseversionThedimensionoftheHMIControlUnitisshowninthenextfigure.Figure16:DimensionoftheHMIControlUnit7Mechanicaldesign7.1REF542plusstandardcaseversion:2I/Oplug-inboardsforcontrolofupto5switchingdevices.1optionalplug-incommunicationboard7.2REF542pluswidecaseversion:3I/Oplug-inboardsforcontrolupto8switchingdevices(withstaticI/Oboard,only7switchingdeviceswithmechanicalI/Oboard.1optionalplug-inboardforoutputof4configurableanalogsignals0to20mAor4to20mA.1optionalcommunicationboard.7.3AnaloginputsREF542plusanaloginputboardisavailableindifferentversionandcanbeequippedwiththefollowingcombinationofinputcurrentand/orvoltagetransformer:3or6currenttransformersforphasecurrents3or6voltagetransformersforphasevoltages1currentorvoltagetransformerfortheresidualcurrentorvoltage1currentorvoltagetransformerformeasurementpurposesWhencombinedsensorsareusedthesignalsareconnectedbyTWINCAMSTplugs.8ListoftheprotectionfunctionsThetablebelowillustratestheprotectionfunctionsinthecur
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年黑龙江省农投食品集团有限公司面向社会公开选聘人员笔试历年参考题库附带答案详解
- 2025山东泰安东平县财金投资集团有限公司招聘17人笔试历年参考题库附带答案详解
- 2025安徽芜湖鸠兹水务有限公司下属子公司第二批工作人员招聘及合成笔试历年参考题库附带答案详解
- 2025天津海泰市政绿化有限公司面向社会招聘项目经理岗位2人笔试历年参考题库附带答案详解
- 2025四川长虹电子控股集团有限公司招聘音响设备工程师岗位1人笔试历年参考题库附带答案详解
- 2025四川泸州市龙驰实业集团有限责任公司及下属子公司招聘3人笔试历年参考题库附带答案详解
- 2025四川华丰科技股份有限公司招聘环保工程师等岗位7人笔试历年参考题库附带答案详解
- 2025中国科技出版传媒股份有限公司武汉分公司招聘5人笔试历年参考题库附带答案详解
- 2025中国华能集团有限公司校园招聘笔试历年参考题库附带答案详解
- 2026年铍铜带线管棒材创新应用案例分析报告
- ISO9001-2026质量管理体系中英文版标准条款全文
- 小学实验室安全知识培训课件
- 产品品质标准化生产与管控指南
- 护理安全消防知识培训课件
- 2025年特种设备检验人员资格考试(场(厂)内专用机动车辆检验员CCY)历年参考题库含答案详解(5套)
- 《GIS空间分析理论与方法》课件-项目一:GIS空间分析基础
- JJG 667-2025 液体容积式流量计检定规程
- 城市建筑群基于弹塑性时程分析的震害评估标准
- 银行业金融机构安全评估标准
- 基于可得然胶改善预制卤牛肉品质特性的研究
- 2022 年全国行业职业技能竞赛- 第十一届全国民政行业职业技能竞赛 殡仪服务员项目 参考题库
评论
0/150
提交评论