版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
MRIPhysics2:ContrastsandProtocolsChrisRorden,PaulMorganTypesofcontrast:ProtocolsStatic:T1,T2,PDEndogenous:T2*BOLD(‘fMRI’),DWExogenous:GadoliniumPerfusionMotion:ASLwww.fmrib.ox.ac.uk/~karla/1MRContrast–adefinitionWeusedifferentMRIprotocolsthataredominatedbydifferentcontrasts.Contrastsinfluencethebrightnessofavoxel.Forexample,water(CSF)isrelativelydarkinaT1-weightedscan,butrelativelybrightinaT2scan.2MRContrastFourtypesofMRcontrasts:StaticContrast:Sensitivetorelaxationpropertiesofthespins(T1,T2)EndogenousContrast:Contrastthatdependsonintrinsicpropertyoftissue(e.g.fMRIBOLD)Exogenouscontrast:Contrastthatrequiresaforeignsubstance(e.g.Gadolinium)Motioncontrast:Sensitivetomovementofspinsthroughspace(e.g.perfusion).3AnatomyofanMRIscanPlaceobjectinstrongstaticmagneticfield,then.TransmitRadiofrequencypulse:atomsabsorbenergyWaitListentoRadioFrequencyemissionduetorelaxationWait,Goto1Timebetweenset1and3isourEchoTime(TE)Timebetweenstep1beingrepeatedisourRepetitionTime(TR).TRandTEinfluenceimagecontrast.TimeTRTE4T1andT2definitionsT1-Relaxation:RecoveryRecoveryoflongitudinalorientation.‘T1time’referstointervalwhere63%oflongitudinalmagnetizationisrecovered.T2-Relaxation:DephasingLossoftransversemagnetization.‘T2time’referstointervalwhereonly37%oforiginaltransversemagnetizationispresent.50.2Contrast:T1andT2EffectsT1effectsmeasurerecoveryoflongitudinalmagnetization.T2referstodecayoftransversemagnetization.T1andT2varyfordifferenttissues.Forexample,fathasverydifferentT1/T2thanCSF.Thisdifferencecausesthesetissuetohavedifferentimagecontrast.T1isprimarilyinfluencedbyTR,T2byTE.CSF:LongT1Fat:ShortT1MagnetizationTR(s)0301CSF:LongT2Fat:ShortT2SignalTE(s)0016T1Effects:getthemwhiletheirdownConsiderveryshortTR:Fathasrapidrecovery,eachRFpulsewillgeneratestrongsignal.Waterhasslowrecovery,littlenetmagnetizationtotip.T1effectsexplainwhywediscardthefirstfewfMRIscans:thesignalhasnotsaturated,sothesescansshowmoreT1thansubsequentimages.Beforefirstpulse:
1Hinalltissue
stronglymagnetized.CSFFatAfterseveralrapidpulses:CSFhaslittlenetmagnetization,sothesetissuewillnotgeneratemuchsignal.7SignalDecayAnalogyAfterRFtransmission,wecandetectRFemissionEmissionatLarmorfrequency.Emissionsamplitudedecaysovertime.Analogoustotuningfork:frequencyconstant,amplitudedecays8RelaxationAfterRFabsorptionends,protonsbegintoreleaseenergyEmissionatLarmorfrequency.Emissionsamplitudedecaysovertime.Differenttissuesshowdifferentratesofdecay.‘FreeInductionDecay’(FID).Strongestsignalimmediatelyaftertransmission.MostsignalwithshortTE.WhynotalwaysuseshortTE?9TEandT2contrastSignalsfromalltissuedecayswithtime.Signaldecaysfasterinsometissuesthanothers.Optimalcontrastbetweentissuewhentheyemitrelativelydifferentsignals.GrayMatter:SlowDecayWhiteMatter:FastDecaySignalTE(s)0.2Contrast:differencebetweenGMandWMsignalSignalTE(s)0.2OptimalGM/WMcontrast10OptimalcontrastOptimalTEwilldependonwhichtissuesyouwishtocontrastGraymatter
vsWhitematterCSF
vsGraymatterSignalTE(s)0.211T2:DephasingRFpulsesetsphase.Initially,everythinginphase:maximumsignal.Signalsgraduallydephase=signalisreduced.Sometissueshowsmorerapiddephasingthanothertissue.TimeCSFFat…12T1andT2contrastsEveryscanisinfluencedbybothT1andT2.However,byadjustingTEandTRwecandeterminewhicheffectdominates:T1-weightedimagesuseshortTEandshortTR.Fatbright(fastrecovery),waterdark(slowrecovery)T2-weightedimagesuselongTEandlongTR:theyaredominatedbytheT2Fatdark(rapiddephasing),waterbright(slowdephasing).ProtondensityimagesuseshortTEandlongTR:reflecthydrogenconcentration.AmixtureofT1andT213T2vsT2*T2onlyonereasonfordephasing:PureT2dephasingisintrinsictosample(e.g.differentT2ofCSFandfat).T2*dephasingincludestrueT2aswellasfieldinhomogeneity(T2m)andtissuesusceptibility(T2ms).Duetotheseartifacts,Larmorfrequencyvariesbetweenlocations.T2*leadstorapidlossofsignal:imageswithlongTEwithhavelittlecoherentsignal.0.2SignalTE(s)001T2T2*14SusceptibilityartifactsMagnetfieldsinteractwithmaterial.Ferromagnetic(iron,nickel,cobalt)Stronglyattracted:dramaticallyincreasesmagneticfield.allsteelhasIron(FE),butnotallsteelisferromagnetic(tryputtingamagnetonaausteniticstainlesssteelfridge).Paramagnetic(Gd)Weaklyattracted:slightlyincreasesfield.Diamagnetic(H2O)Weaklyrepelled:slightlydecreasesfield.15TissueSusceptibilityDuetospin-spininteractions,hydrogen’sresonancefrequencydiffersbetweenmaterials.E.G.hydrogeninwaterandfatresonateatslightlydifferentfrequencies(~220Hz;1.5T).Macroscopically:Theseeffectscanleadspatialdistortion(e.g.‘fatshift’relativetowater)andsignaldropout.Microscopically:fieldgradientsatboundariesofdifferenttissuescausesdephasingandsignalloss.16FieldInhomogeneityArtifactsWhenweputanobject(likesomeone’shead)insideamagnet,thefieldbecomesnon-uniform.Whenthefieldisinhomogeneous,wewillgetartifacts:resonancefrequencywillvaryacrossimage.Priortoourfirstscans,thescanneris‘shimmed’tomakethefieldasuniformaspossible.Shimmingisdifficultnearair-tissueboundaries(e.g.,sinuses).Shimmingartifactsmoreintenseathigherfields.17SpinEchoSequenceSpinechosequencesapplya180ºrefocusingpulsehalfwaybetweeninitial90ºpulseandmeasurement.Thispulseeliminatesphasedifferencesduetoartifacts,allowingmeasurementofpureT2.Spinechodramaticallyincreasessignal.SignalTime01T2T2*0.5TE0.5TEActualSignal18SpinEchoSequencesTherefocusingpulseallowsustorecovertrueT2.ImagefromWebsiteincludesinteractiveadjustmentofT1/T2T2T2*19AnalogyforSpinEchoConsidertwoclocks.Clock1:minutehandtakes70minutestomakearevolution.Clock2:minutehandtakes55minutestomakearevolution.Simultaneously,setbothclockstoread12:00.(~sendin90ºRFpulse).WaitpreciselyonehourMinutehandsnowdiffer:outofphase.Reversedirectionofeachclock(~sendin180ºRFpulse).WaitpreciselyonehourMinutehandsnowidentical:bothreadnoon.TheyarebrieflybackinphaseMinutehandrotation0420º1hour1hour20T2*:fMRISignalisanartifactfMRIis‘BloodOxygenationLevelDependent’measure(BOLD).Brainregionsbecomeoxygenrichafteractivity:ratioofHbr/HbrO2decreases21BOLDeffectDeoxyhemoglobin(Hbr)actsascontrastagentFrequencyspreadcausessignallossovertimeEffectincreaseswithdelay(TE=echotime)But,overallsignalreduceswithTE.OptimalBOLDTE~60msfor1.5T,~30msat3T.Feraetal.(2023)JMRI19,19-26www.fmrib.ox.ac.uk/~karla/LowHighFrequency0.2TE(s)022BOLDartifactsfMRIisaT2*image–wewillhavealltheartifactsthataspin-echosequenceattemptstoremove.Dephasingnearair-tissueboundaries(e.g.,sinuses)resultsinsignaldropout.BOLDNon-BOLDwww.fmrib.ox.ac.uk/~karla/23OptimalfMRIscansMoreobservationswithshorterTR,butslightlylesssignalperobservation(duetoT1effectsandtemporalautocorrelation).WhenyouhaveasingleanatomicalregionofinterestusethefewestslicesrequiredforaveryshortTR.Forexploratorygroupstudy,useascanthatcoverswholebrainwithminimalspatialdistortion(forgoodnormalization).Typical3T:3x3x3mm64x64matrix,36slices,SENSEr=2,TE=35ms,TR=2100msTypical1.5T:3x3x3mm64x64matrix,36slcies,TE=60ms,TR=3500ms.ShorterTRyieldsbetterSNRDiminishingreturnsG.H.Glover(1999)‘OnSignaltoNoiseRatioTradeoffsinfMRI’24DiffusionImagingDiffusionimagingisanendogenouscontrast.Applytwogradientssequentiallywithoppositepolarity.Stationarytissuewillbebothdephasedandrephased,whilespinsthathavemovedwillbedephased.Sensitivetoacutestroke(DWI,seelesionlecture)Multipledirectionscanmeasurewhitematterintegrity(diffusiontensorimaging,seeDTIlecture)waterdiffusesfasterinunconstrainedventriclesthaninwhitematter25GadoliniumEnhancementGdPravenously-injected.GdnotdetectedbyMRI(1H).Gdhasaneffectonsurrounding1H.GdshortensT1,T2,T2*ofsurroundingtissue.makesvessels,highlyvasculartissues,andareasofbloodleakageappearbrighter.Veryraresideeffect:allergicreaction.Gdcanhelpmeasureperfusion.Usefulforclinicalstudies:howmuchbloodisgettingtoaregion,howlongdoesittaketogetthere?26TimeofFlightToFisamotioncontrast.InT1scans,motionofbloodbetweenslicescancauseartifacts.ToFintentionallymagnifiesflowartifacts.SeveralProtocolsofToF,E.G:UseveryshortTR,sosignalinsliceissaturated.Externalspinsflowingintoslicehavefullmagnetization.ConductaSpinEchoScan:90ºand180ºinversionpulsesappliedtodifferentslices.Onlynucleithattravelbetweenslicesshowcoherentsignal.SaturatedSpinsUnsaturatedSpinsSLICEFlow27ArterialSpinLabellingASLisanexampleofamotioncontrastIMAGEperfusion=IMAGEuninverted–IMAGEinvertedPerfusionisusefulforclinicalstudies:howmuchbloodisgettingtoaregion,howlongdoesittaketogetthere?www.fmrib.ox.ac.uk/~karla/inversionslabimagingplaneexcitationinversionxyz(=B0)bloodwhitematt
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026呼伦贝尔市发展和改革委员会所属事业单位第二批引进人才评估认定考试模拟试题及答案解析
- 2026年太仓市文化教育投资集团有限公司及下属控股子公司第二批次公开招聘4人笔试参考题库及答案解析
- 2026年德州陵城区公开招聘城镇公益性岗位人员考试模拟试题及答案解析
- 2026年孕妇营养保健品行业洞察报告及未来五至十年发展趋势报告
- 中国海洋石油集团有限公司2027届校园招聘考试参考题库及答案解析
- 2026年芜湖宣城机场建设投资有限公司见习生选拔笔试参考题库及答案解析
- 2026黔西南州秋季赴省内外高校引进高层次人才和急需紧缺人才128人考试参考题库及答案解析
- 2027中国海洋石油集团校园招聘笔试参考题库及答案解析
- 2026年半导体器件专用设备制造行业消费行为研究报告及未来五至十年降本增效与利润率修复
- 2026年甘肃省定西市第二批人才引进360人考试备考题库及答案解析
- 2026学校入团考试题库(附答案解析)
- 2026年10月自考04842产品系统化设计押题及答案(北京)
- 2026年招标采购从业人员《招标采购专业理论与法律基础(初级)》考试真题(含解析)
- 高考688个高频词汇
- 【答案】《人工智能与创新》(南开大学)章节期末中国大学慕课答案
- 悬臂吊起重机技术说明书
- 2025 中国过敏性休克急救指南(中文版)完整原文 + 肾上腺素使用规范
- 班长在班组管理实践中的核心作用与能力提升
- 2026年4月自考00164劳动经济学试题及答案
- 某铝业厂电解操作规范制度
- 水电部门采购制度
评论
0/150
提交评论