1Generalprovisions
Thisstandardispreparedwithaviewtoimplementtheconceptofgreendevelopment,promotethehigh-qualitydevelopment,saveresources,protecttheenvironment,reducecarbonemissionsfromconstruction,promoteharmonybetweenmanandnature,improvethelivingenvironmentincountriesalongtheSilkRoadEconomicBeltandthe21st-CenturyMaritimeSilkRoad,andsupportthepromotionofgreenbuildingsinthosecountries
ThisstandardisapplicabletotheassessmentonthegreenperformanceofcivilbuildingsincountriesalongtheSilkRoadEconomicBeltandthe21st-CenturyMaritimeSilkRoad.
Theassessmentofgreenbuildingshallfollowtheprincipleofadaptingtolocalconditions,inconsiderationoftheclimate,environment,resources,economy,culture,etc.ofthecountryorregionwherethebuildingsarelocated,andthenmakeacomprehensiveassessmentofthebuildingsintermsofsafetyanddurability,healthandcomfort,occupantconvenience,resourcessavingandenvironmentlivabilityduringthewholelifecycleofthebuildings.
Greenbuildingshallbecombinedwithlandformsforsitedesignandbuildinglayout,andbuildinglayoutshallbeadaptedtotheclimaticconditionsandgeographicalenvironmentofthesite;meanwhile,thewind,light,thermalandacousticenvironmentsofthesiteshallbeconsideredandused.
Inadditiontotherequirementsstipulatedinthisstandard,theassessmentofgreenbuildingshallcomplywiththosestipulatedinthecurrentrelevantlocalstandards.
2Terms
GreenBuilding
Thehigh-qualitybuildingthatisabletosavetheresources,protecttheenvironmentandreducepollutiontoprovidepeoplewithahealthy,applicableandefficientspaceandmaximallyrealizeharmoniouscoexistencewiththenatureduringitswholelifecycle.
GreenPerformance
Thecomprehensiveperformanceofbuildingintermsofsafetyanddurability,healthandcomfort,occupantconvenience,resourcesaving(landsaving,energysaving,watersavingandmaterialsaving)andenvironmentallivability.
WaterQualityRegularIndices
Thewaterqualityindexthatcanreflectthebasicconditionofdrinkingwaterquality
WeightedStandardizedLevelDifference
Thesinglenumberquantityoftheairbornesoundinsulationperformancebetweentworoomsobtainedbyusingthereverberationtimeofthereceivingroomasamodifiedparameter.
ValueOfDaylightFactor
Theratioofilluminancedirectlyorindirectlyreceivedfromtheassumedandknowndistributeddiffuseskylightfromatapointontheindoorsworkingplanetothesimultaneousoutdoorilluminanceonahorizontalplanefromanunobstructedhemisphereofovercastsky.
LightingPowerDensity
Installationpowerperunitareaofgenerallighting(includingauxiliaryelectricaldevicessuchaslightsources,ballastsortransformers)inwattspersquaremeter(W/m2).
BioclimaticDesign
Architecturaldesignmethodthatconsistentwiththelocalnaturalenvironment,whichcanpromoteenvironmentalsustainabilityandbringpeoplepleasantandcomfort.
GreenBuildingMaterial
Thebuildingmaterialswiththecharacteristicsofenergy-saving,emissionreduction,safety,health,convenienceandrecyclability,whichcanreducetheconsumptionofresourcesandtheimpactontheecologicalenvironmentduringthewholelifecycle.
HeatIslandIntensity
Acharacterizationparameteroftheurbanheatislandeffect,bywhichthedifferencesoftheairtemperaturebetweenoneurbanareaandthesuburbareaisexpressedbythetemperaturedifferencebetweenthetypicalmeasuringpoints.
3BasicRequirements
3.1GeneralRequirements
Assessmentofgreenbuildingshalltakeasinglebuildingoragroupofbuildingsastheassessedobject;theassessmentindexesinvolvingsystemicandholisticcharacteristicsshallbebasedontheoverallprojecttowhichthebuildingbelongs.
Theassessmentofgreenbuildingincludestwoparts:Pre-assessmentshallbeconductedafterthecompletionoftheconstructiondrawingdesign;assessmentshallbeconductedafterconstruction.
Theapplicantforgreenbuildingassessmentshallconductthetechnicalandeconomicanalysisonthebuildingsduringthewholelifecycle,selectappropriatetechnologies,equipmentandmaterials,controlthewholeprocessoftheplanning,design,constructionandoperation,andsubmitcorrespondinganalysisandtestreportsaswellasrelateddocuments.Theapplicantshallalsoberesponsiblefortheauthenticityandintegrityofthesubmittedassessmentmaterials.
Theassessmentorganizationshallverifytheanalysis,testreportsandrelateddocumentssubmittedbytheapplicant,issueanassessmentreportandspecifythegrade.
Buildingsapplyingforgreenfinancialservicesshallbecalculatedandexplainedintermsofenergysavingmeasures,watersavingmeasures,buildingenergyconsumptionandcarbonemissions,andshallformaspecialreport
3.2AssessmentandRating
Theassessmentindexsystemofgreenbuildingshallconsistoffivecategoriesofindexessafetyanddurability,healthandcomfort,occupantconvenience,resourcessavingandenvironmentlivability.Eachcategoryofindexesincludesprerequisiteitemsandscoringitems.Theassessmentindexsystemisalsouniformlyprovidedwithbonusitems.
Theassessmentresultoftheprerequisiteitemsshallbe"pass"or"fail";theassessmentresultofthescoringitemsandthebonusitemsshallbescore
Asforamultifunctionalandcomprehensiveindividualbuilding,theapplicableareasshallbeassessedinaccordancewithalltheprovisionsspecifiedinthisstandardonebyonetodeterminethescoreofeachprovision.
ThescoresofgreenbuildingassessmentshallbeinaccordancewiththerequirementsspecifiedinTable3.2.4
表3.2.4ScoresofGreenBuildingAssessment
Basicscoreforprerequisiteitems
Fullscoreofscoringitemsforassessmentindex
Fullscoreofbonusitemsdoepromotionandinnovation
Safetyanddurability
Healthandcomfort
Occupantconvenience
Resourcessaving
Environmentlivability
Pre-assessmentscore
400
100
100
70
200
100
100
Assessmentscore
400
100
100
100
200
100
100
Thetotalscoreoftheassessmentofgreenbuildingiscalculatedusingthefollowingequation:
Q=(Q0+Q1+Q2+Q3+Q4+Q5+QA)/10(3.2.5)
Where:Q——thetotalscore;
Q0——thebasicscoreoftheprerequisiteitems,whichisscored400pointswhenalltheprerequisiteitemsarepassed;
Q1~Q5——thescoresofthescoringitemsoffivecategories(safetyanddurability,healthandcomfort,occupantconvenience,resourcessavingandenvironmentlivability);
QA——thescoreofbonusitemsforopennessandinnovation.
Greenbuildingsshallbedividedintofourgrades:basic,one-star,two-starandthree-star.
Whentherequirementsofallprerequisiteitemsaremet,thegreenbuildinggradeshallbethebasicgrade.
Thestargradeofgreenbuildingshallberatedaccordingtothefollowingrequirements:
1Greenbuildingsofone-star,two-starandthree-starshallmeettherequirementsofallprerequisiteitemsinthisstandardandthescoreforscoringitemsofeachcategoryofindexshallnotbelessthan30%ofitsfullscore;
2Whenthetotalscorereaches60points,70points,85pointsrespectively,thegreenbuildingsareratedasthegradeofone-star,two-starandthree-starrespectively
4SafetyandDurability
4.1PrerequisiteItems
Siteswithgeologicalriskssuchaslandslidesandmudslidesshallbeavoided.Flood-proneareasshallbeprovidedwithflood-proofinfrastructure,termitepreventionandcontrolshallbedoneinareasvulnerabletotermiteinfestation;thesitesshallbefreefromthethreatsofdangerouschemicals,inflammableandexplosivesourcesaswellasthehazardsofelectromagneticradiationandradon-containingsoil.
Thebuildingstructureshallmeettherequirementsforbearingcapacityandbuildingfunction.Buildingenvelopessuchastheexteriorwall,roofing.doorsandwindows,curtainwallsandexteriorinsulationofthebuildingshallmeettherequirementsofsafety,durabilityandprotection.
Theexteriordoorsandwindowsofthebuildingmustbeinstalledfirmly,anditswindloadresistanceperformanceandwatertightnessperformanceshallmeetthefunctionalrequirementsofthebuilding,andadapttothelocalenvironment.
Thefloorofthebathroomandtoiletshallbeprovidedwithawaterprooflayerandtheirwallsandceilingsshallbeprovidedwithamoistureprooflayer.
Passagespacessuchascorridorsandevacuationpassagesshallmeettherequirementsofemergencyevacuationandemergencyrescue,andshallbekeptunblocked.
Thewarningandguidancesignagesystemforsafetyprotectionshallbeinstalledinthebuilding.
4.2ScoringItems
ⅠSafety
Theadoptionofperformance-basedseismicdesignandtherationalimprovementoftheseismicperformanceofthebuildingaretotallyscored10points.
Takeprotectivemeasurestoensurepeople'ssafety,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally12points:
1Takemeasurestoimprovetheprotectionlevelofbalcony,exteriorwindow,windowsill,balustrade,etc.,whichisscored4points;
2Buildingentrancesandexitsareprovidedprotectivemeasuresforaccidentalfalloutofexternalwalldecorationsaswellastheglazingofdoorsandwindows,andtheprotectivemeasuresarecombinedwithsunshade,windorrainprotectionfacilitiesintheareaopentopeople,whichisscored4points;
3Usethesiteorlandscapetoformabufferzoneandisolationzonethatcanreducetheriskoffallingobjects,whichisscored4points.
Useproductsoraccessorieswithsafetyprotection,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally10points:
1Useglasseswithsafetyprotectionfunction,whichisscored5points;
2Usedoorsandwindowswithanti-pinchfunction,whichisscored5points.
Takeanti-slipmeasuresforindoorandoutdoorfloorsorroadsurfaces,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally9points:
1Takeanti-slipmeasuresforbuildingentrancesandexits,platforms,publiccorridors,elevatorhalls,kitchens,bathrooms,toilets,etc.,theanti-skidlevelshallnotbelowerthanBdandBwinTable4.2.4-1and4.2.4-2,whichisscored3points;
2Asforanti-slipgroundforindoorandoutdooractivities,theanti-sliplevelreachesAdandAwlevelinTable4.2.4-1and4.2.4-2,whichisscored3points;
3Theanti-sliplevelofconstructionrampsandstairstepsreachesAdandAwinTable4.2.4-1and4.2.4-2,orisonelevelhigherthanthelevelground,andanti-slipconstructiontechnologymeasuressuchastheuseofanti-slipbars,whichisscored3points.
Table4.2.4-1Wetslipresistancevaluesofoutdoorandindoorwetfloors
Anti-sliplevel
Safetydegreeofanti-slip
Anti-slipvalueBPN
Aw
High
BPN≥80
Bw
Mediumtohigh
60≤BPN<80
Cw
Middle
45≤BPN<60
Dw
Low
BPN<45
Table4.2.4-2Staticfrictioncoefficientofindoordryground
Anti-sliplevel
Safetydegreeofanti-slip
StaticfrictioncoefficientCOF
Ad
High
COF≥0.70
Bd
Mediumtohigh
0.60≤COF<0.70
Cd
Middle
0.50≤COF<0.60
Dd
Low
COF<0.50
Separatepedestriansystemfromvehiclesystem,andprovidethewalkingandbicycletransportationsystemwithsufficientlighting,whichisscored5points.
Videosurveillancesystemissetinpublicareas,whichisscored10points.
ⅡDurability
Takemeasurestoimprovethestructuraladaptabilityofbuildings,whichisrelativelyscoredandaccumulatedaccordingtothefollowingcriteria,totally15points:
1Takeageneralopen,flexibleandvariablespacedesign,oradoptmeasuresofvariablebuildingfunction,whichisscored5points;
2Thebuildingstructureisseparatedfromtheconstructionequipmentpipeline,whichisscored5points;
3Adoptlayoutorcontrolmethodsofequipmentfacilitiesthatarecompatiblewithbuildingfunctionsandspatialchanges,whichisscored5points.
Takemeasurestoimprovethedurabilityofbuildingparts,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally10points:
1Adoptpipes,pipelinesandfittingswithgoodcorrosionresistance,anti-aginganddurability,whichisscored5points;
2Themovablepartsareselectedfromlong-lifeproducts,andthesamelifespanofthepartscombinationisconsidered;whenthepartsofdifferentservicelifeareconnected,thestructureeasytobeseparatelyreplacedandupdatedisadopted,whichisscored5points.
Improvethedurabilityofbuildingstructurematerials,whichisscoredaccordingtothefollowingcriteria,totally10points:
1Designfor100-yeardurability,whichisscored10points.
2Adoptbuildingstructurematerialswithgooddurabilitythatmeetoneofthefollowingconditions,whichisscored10points:
1)Forconcretemembers,increasethethicknessoftheprotectivelayeroftherebarorusehigh-durabilityconcrete;
2)Forsteelmembers,adoptweather-resistantstructuralsteelorweather-resistantanticorrosivecoatings;
3)Forwoodmembers,useanti-corrosivewood,durablewoodordurablewoodproducts.
Rationallyusedurableandeasy-to-maintaindecorativebuildingmaterials,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally9points:
1Adoptdurableexteriorfinishmaterials,whichisscored3points;
2Adoptdurablewaterproofandsealingmaterials,whichisscored3points;
3Adoptdurableandeasy-to-maintaininteriordecorationmaterials,whichisscored3points.
5HealthandComfort
5.1PrerequisiteItems
Theconcentrationofpollutantssuchasformaldehyde,benzeneandtotalvolatileorganiccompoundsinindoorairshallmeettherequirementsoftherelevantlocalstandards.Smoke-freemanagementinthebuildingshallcomplywithlocalrequirements.
Measuresshallbetakentoavoidtheairandpollutantsinthekitchen,diningroom,printingandcopyingroom,bathroom,undergroundgarageandotherareasfromgoingintootherspaces;theexhaustbackflowofkitchenandbathroomshallbeprevented.
Thesettingofwatersupplyanddrainagesystemshallbeinaccordancewiththefollowingrequirements:
1Theconventionalindicatorsandlimitsofthequalityofdrinkingwatershallmeettherequirementsofrelevantlocalstandards;
2Theregularcleaninganddisinfectionplanforwaterstoragefacilitiessuchaswaterreservoirsandwatertanksshallbeformulatedandimplemented,andthedrinkingwaterstoragefacilitiesshallbecleanedanddisinfectedatleastonceeverysixmonths.
Reasonableplanningandarrangementofsiteandindooracousticenvironmentshallbecarriedout,whichshallbeinaccordancewiththefollowingrequirements:
1Thenoisesourceareasandnoisesensitiveareasintheprojectshallbereasonablyplannedandarranged.
2Thefunctionalareasinthebuildingshallberationallyplannedandarrangedaccordingtotheacousticenvironmentspace.
Thequantityandqualityofbuildinglightingshallmeettherequirementsoflocalstandards.
Measuresshallbetakentoensuretheindoorthermalenvironment.Forbuildingswithcentralheatingandairconditioningsystems,thedesignparametersoftheroomsuchastemperature,humidityandfreshairvolumeshallcomplywiththerelevantrequirementsofthelocalstandards.
Thethermalperformanceofthebuildingenvelopeshallmeetthefollowingrequirements:
1Undertheconditionofindoordesigntemperatureandhumidity,dewshallnotappearontheinnersurfaceofthenon-transparentbuildingenvelope;
2Condensationshallnotexistontheroofandtheinsideofexteriorwallsoftheheatingbuilding;
3Complywithrelevantlocalstandardstoavoidoverheatinginsummer.
Themainfunctionroomsshallbeequippedwithathermalenvironmentadjustmentdeviceindependentlycontrolledonsite.
5.2ScoringItems
ⅠIndoorAirQuality
Controltheconcentrationofmainairpollutantsintheroom,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally10points:
1Theconcentrationofmajorpollutantsis10%lowerthanthelimitstipulatedintherelevantlocalstandards,whichisscored3points;itis20%lowerthanthelimits,whichisscored6points;
2TheannualaverageconcentrationofPM2.5intheroomisnothigherthan15µg/m³,andtheannualaverageconcentrationofPM10intheroomisnothigherthan30µg/m³,whichisscored4points.
ThedesignminimumfreshairvolumeintheroomcomplieswiththecalculationresultofEq.(5.2.2),whichisscored5points.
qtot=n×qp+A×qb(5.2.2)
Where:qtot——thetotalventilationrateforthebreathingzone,L/s;
n——thedesignvalueforthenumberofthepersonsintheroom;
qp——theventilationrateforoccupancyperperson,L/(s·person);
A——thefloorarea,m2;
qb——theventilationrateforemissionsfrombuilding,L/(s·m2).
Table5.2.2-1DesignVentilationRatesforPersonsforDifferentCategories
Category
Expectedpercentagedissatisfied
(%)
Airflowperperson
[L/(s·person)]
Ι
15
10
Π
20
7
Ш
30
4
Ⅳ
40
2.5
Table5.2.2-2DesignVentilationRatesforDilutingEmissionsof
DifferentTypeofBuildings
Category
Verylowpollutingbuilding
[L/(s·m2)]
Lowpollutingbuilding
[L/(s·m2)]
Nonlowpollutingbuilding
[L/(s·m2)]
Ι
0.5
1.0
2.0
Π
0.35
0.7
1.4
Ш
0.2
0.4
0.8
Ⅳ
0.15
0.3
0.6
Theundergroundgarageshallbeequippedwithacarbonmonoxideconcentrationmonitoringdevicelinkedtotheexhaustequipment,whichisscored8points.
ⅡWaterQuality
Thewaterqualityoffinedrinkingwater,centraldomestichotwater,swimmingpoolwater,etc.meettherequirementsstipulatedintherelevantlocalstandards,whichisscored8points.
Measuresaretakenforwaterstoragefacilitiessuchasdrinkingwaterreservoirsandwatertankstomeetthehygienerequirements,whichisrespectivelyscoredandaccumulatedaccordingthefollowingcriteria,totally9points:
1Usethefinishedproductwatertankthatmeetstherequirementsstipulatedintherelevantlocalstandards,whichisscored5points;
2Takemeasurestoensurethatthestoredwaterdoesnotdeteriorate,whichisscored4points.
Allwatersupplyanddrainagepipes,equipmentandfacilitiesareprovidedwithdefinite,clearandpermanentmarks,whichisscored8points.
ⅢSoundandDaylighting
Theindoornoiselevelofthemainfunctionalroomisbetterthanthelimitoftherelevantlocalstandards,whichisscoredaccordingtothefollowingcriteria,totally8points:
1Theindoornoiselevelofthemainfunctionalroomis3dBlowerthanthecurrentlocalstandardlimit,ormeetthegoodstandardlimitstipulateintable5.2.7,whichisscored4points;
2Theindoornoiselevelofthemainfunctionalroomis5dBlowerthanthecurrentlocalstandardlimit,ormeetthebeststandardlimitstipulateintable5.2.7,whichisscored8points.
Table5.2.7StandardLimitofIndoorNoiseLevel
Mainfunctionroom
Goodstandardlimit
Beststandardlimit
Residentialbuilding
Bedroom
≤32dB,LAeq,T(nighttime)
≤30dB,LAeq,T(nighttime)
Livingroom
≤37dB,LAeq,T
≤35dB,LAeq,T
School
buildings
Commonclassroom、Laboratory、MultimediaClassroom、Danceroom
≤42dB,LAeq,T
≤40dB,LAeq,T
Languageclassroom、Readingroom、Musicclassroom、Pianoroom
≤37dB,LAeq,T
≤35dB,LAeq,T
Hospital
buildings
Ward、Medicalstaffdutyroom、ICU
≤32dB,LAeq,T(nighttime)
≤30dB,LAeq,T(nighttime)
Clinic、Operatingroom、Deliveryroom、Laboratory、Analyticallaboratory
≤37dB,LAeq,T
≤35dB,LAeq,T
Cleanoperatingroom
≤42dB,LAeq,T
≤40dB,LAeq,T
Artificialreproductioncenterpurificationarea
≤37dB,LAeq,T
≤35dB,LAeq,T
Entrancehall、Waitingroom
≤52dB,LAeq,T
≤50dB,LAeq,T
Hotel
buildings
Guestroom
≤32dB,LAeq,T(nighttime)
≤30dB,LAeq,T(nighttime
Office、Meetingroom、Multipurposehall
≤37dB,LAeq,T
≤35dB,LAeq,T
Dinningroom、Ballroom、Hotellobby
≤45dB,LAeq,T
≤43dB,LAeq,T
Officebuildings
Singleoffice
≤37dB,LAeq,T
≤35dB,LAeq,T
Multi-personoffice、Meetingroom
≤42dB,LAeq,T
≤40dB,LAeq,T
Commercialbuildings
Shoppingmall、Store、Shoppingcenter、ExhibitionCenter
≤52dB,LAeq,T
≤50dB,LAeq,T
Restaurant
≤50dB,LAeq,T
≤45dB,LAeq,T
Stafflounge
≤42dB,LAeq,T
≤40dB,LAeq,T
Thesoundinsulationperformanceofthemainfunctionalroomsisbetterthantherelevantlocalstandards,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally10points:
1Theairsoundinsulationperformancebetweenroomsis2dBbetterthanthecurrentlocalstandardlimit,ormeetthegoodstandardlimitintable5.2.8-1,whichisscored3points;5dBbetterthanthecurrentlocalstandardlimit,ormeetthebeststandardlimitintable5.2.8-1,whichisscored5points;
2Theimpactsoundinsulationperformanceofthefloorslabis2dBbetterthanthecurrentlocalstandardlimit,ormeetthegoodstandardlimitintable5.2.8-2,whichisscored3points;5dBbetterthanthecurrentlocalstandardlimit,ormeetthebeststandardlimitintable5.2.8-2,whichisscored5points;
Table5.2.8-1StandardLimitsforAirborneSoundInsulationPerformance
betweenRooms
Buildingtype
Component/Room
Goodstandardlimit
Beststandardlimit
Residentialbuildings
Betweenbedroomandneighboringroom
DnT,w+C≥52dB
DnT,w+C≥55dB
Betweenlivingroomandneighboringroom
DnT,w+C≥50dB
DnT,w+C≥53dB
Bedroomwithwindowonexteriorwall
D2m,nT,w+Ctr≥37dB
D2m,nT,w+Ctr≥40dB
School
buildings
Betweencommonclassrooms
DnT,w+C≥47dB
DnT,w+C≥50dB
Betweenlanguageclassrooms,readingroomsandadjacentrooms
DnT,w+C≥52dB
—
Hospital
buildings
Betweenwards
DnT,w+C≥47dB
DnT,w+C≥50dB
Betweenclinics
DnT,w+C≥42dB
DnT,w+C≥45dB
Hotel
buildings
Betweenrooms
DnT,w+C≥50dB
DnT,w+C≥53dB
Guestroomwithwindowonexteriorwallandglasscurtainwall
D2m,nT,w+Ctr≥37dB
D2m,nT,w+Ctr≥40dB
Office
buildings
Betweenoffices,meetingroomsandcommonrooms
DnT,w+C≥47dB
DnT,w+C≥50dB
Commercialbuildings
Betweenfitnesscenters,entertainmentvenues,etc.andnoise-sensitiverooms
DnT,w+Ctr≥57dB
DnTw+Ctr≥60dB
Betweenshoppingcenters,restaurants,conventioncenters,etc.andnoise-sensitiverooms
DnT,w+Ctr≥47dB
DnTw+Ctr≥50dB
Table5.2.8-2StandardLimitofFloorImpactSoundInsulationPerformance
Buildingtype
Floorposition
Goodstandardlimit
Beststandardlimit
Residentialbuildings
Householdfloorofbedroomand
livingroom
L’nT,w≤62dB
L’nT,w≤60dB
School
buildings
Floorslabsbetweenspeechclassroom,readingroomandupperroom
L’nT,w≤62dB
L’nT,w≤60dB
Floorbetweencommonclassrooms
L’nT,w≤67dB
L’nT,w≤65dB
Hospital
buildings
Floorslabsbetweenwards,operatingtheatresandupperrooms
L’nT,w≤67dB
L’nT,w≤65dB
Hotel
buildings
Floorslabsbetweenguestroomandupperroom
L’nT,w≤62dB
L’nT,w≤60dB
Office
buildings
Floorslabsontopofoffices,meetingrooms
L’nT,w≤67dB
L’nT,w≤65dB
Commercialbuildings
Floorslabsbetweenfitnesscenters,entertainmentvenues,etc.andnoise-sensitiverooms
L’nT,w≤47dB
L’nT,w≤45dB
Makefulluseofdaylighting,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally9points:
1Asforatleast60%areaofmainfunctionalspacesoftheresidentialbuilding.itsaveragenumberofhourswithandaylightingilluminancevalueofnotlessthan300lxisnotlessthan8h/d,whichisscored9points;
2Publicbuildingsarerespectivelyscoredandaccumulatedaccordingtothefollowingcriteria:
1)Thearearatiooftheinnerareadaylightfactormeetingthedaylightingrequirementsis60%,whichisscored3points;
2)Theratiooftheareaoftheundergroundspacewithanaveragedaylightfactorofnotlessthan0.5%totheareaofthefirstbasementfloorismorethan10%,whichisscored3points;
3)Thehoursofatleast60%floorareaoftheindoormainfunctionalspaceswithrequireddaylightingilluminancevalueisnotlessthan4h/d,whichisscored3points.
3Themainfunctionroomshasglarecontrolmeasures,whichisscored3points.
ⅣIndoorThermalEnvironment
Indoorthermalandhumidenvironmentisfavorable,whichisscoredaccordingtothefollowingcriteria,totally8points:
1Forbuildingswithnaturalventilationorhybridventilation,thetimeratioofindoorthermalenvironmentparametersinthemainfunctionalroomsofthebuildingtotheadaptivethermalcomfortzonereaches30%,whichisscored2points;foreachadditional10%,1pointisadded,atmost8points;
2Forthebuildingwithartificialcoldandheatsources,60%ofthemainfunctionroomsarethermallycomfortabletomeettherequirementsinTable5.2.10,whichisscored5points;foreachadditional10%,1pointisadded,atmost8points.
Table5.2.10RequirementsofThermalComfort
Thermalstateofthebody
asawhole
Localdiscomfort
PMV
PPD(%)
DR(%)
PD(%)causedby
verticalairtemperaturedifference
Cwarmorcoolfloor
Rradiantasymmetry
-0.7<PMV<0.7
<15
<30
<10
<15
<10
Optimizethebuildingspaceandplanelayout,improvethenaturalventilationeffect,whichisscoredaccordingtothefollowingcriteria,totally8points:
1Residentialbuildings:theratiooftheventilationopeningareatotheroomfloorareareaches10%inthetropicalareas,and5%inotherareas,whichisscored5points;foreachadditional2%,1pointisadded,atmost8points;
2Non-residentialbuildings:Thelocationoftheairsupplyandexhaustventsshallconsiderthedepth(W:m)andheight(H:m)oftheroom,andmeettherequirementsinTable5.2.11,whichisscored8points.
Table5.2.11NaturalVentilationStrategiesforNon-residentialBuildings
Ventform
RatioofroomdepthtofloorandceilingheightW/H
Aventononesideofthefaçade
W/H≤2
Twoventononesideofthefaçade
W/H≤2.5
Oneventoneachoftheoppositefaçades
W/H≤5
Theadjustableshadingfacilitiesaresettoimprovetheindoorthermalcomfort,whichisscoredaccordingtotheproportionoftheadjustableshadeareatothetransparentpartoftheexteriorwindowandthecriteriaspecifiedinTable5.2.12,totally9points.
Table5.2.12ScoringCriteriafortheProportionoftheAreaofAdjustableShadingFacilitiesintheTransparentPartoftheExteriorWindow
Proportionoftheareaofadjustableshadingfacilitiesinthetransparentpartoftheexteriorwindow,SZ
Score(Points)
25%≤SZ<35%
3
35%≤SZ<45%
5
45%≤SZ<55%
7
SZ≥55%
9
6OccupantConvenience
6.1PrerequisiteItems
Accessiblebarrier-freewalkingsystemshallbeprovidedbetweenbuildings,outdoorsites,publicgreenspacesandurbanroads.
Theparkinglotshallbeequippedwiththechargingfacilitiesofnewenergyvehicleortheinstallationconditionsofthecharg
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- GB/T 6256-2026工业加热三极管空白详细规范
- 2027届广东省广州市部分区及学校化学九年级第一学期期中质量跟踪监视试题含解析
- 2027届江西省中学等学校九年级化学第一学期期中检测试题含解析
- 天津市河东区天铁一中学2027届化学九上期中综合测试试题含解析
- 湖北省黄冈市黄州区启黄中学2027届九年级化学第一学期期末达标检测模拟试题含解析
- 2027届江南省郸城县化学九年级第一学期期末学业质量监测试题含解析
- 安徽省灵璧县2027届物理九年级第一学期期末质量跟踪监视试题含解析
- 2027届福建省泉州市晋江市泉州五中学桥南校区化学九上期末检测试题含解析
- 2026中国月子中心服务标准化建设与区域扩张战略研究
- 甘肃省酒泉市瓜州县2027届化学九年级第一学期期中质量跟踪监视模拟试题含解析
- 新生儿复苏操作技能考核评分标准(2025 版)中文版 逐项打分 + 合格判定细则
- 2025年广西卫生职业技术学院教职人员招聘笔试真题(含完整答案解析)
- 2026年医师定期考核试题题库中医入门试题及答案
- 山洪灾害预警识别知识
- 2025-2026学年人教版生物必修二全册综合检测练习卷(含解析)
- 2025年【熔化焊接与热切割】作业考试题库(含答案)
- 客户服务管理员(三级)考试复习题库(浓缩300题)
- 小升初湖北省黄石市阳新县2025年(人教版)数学考试试题 含答案
- 2026小红书有感运动IP方案
- 天然气管线保护施工方案
- 2025届中工国际工程股份有限公司校园招聘笔试历年参考题库附带答案详解
评论
0/150
提交评论