PermeabilityPluggingTesterwithLCM
Receiver,6000psi
#171-193-6K:115Volt#171-193-6K-1:230Volt
InstructionManual
Updated6/14/2019Ver.4
OFITestingEquipment,Inc.
11302SteeplecrestDr.·Houston,Texas·77065·U.S.A.Tele:832.320.7300·Fax:713.880.9886·
©CopyrightOFITE2017
OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/
PAGE
1
TableofContents
Intro2Description2Specifications2
Components3
Safety5
QuickStart7
Preparation10
CellAssembly11
Testing16
Data19
CellCapAssembly20
PistonAssembly21
Maintenance22
Diagrams24PermeabilityPluggingTester24
TestCell25
WarrantyandReturnPolicy26
OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/
PAGE
2
Intro
DescriptionSpecifications
ThePermeabilityPluggingTester(PPT)isamodificationofthestandard500mLHTHPFilterpress.Itmaybeusedinthefieldorinalaboratoryenvironment.Theinstrumentisusefulforperformingfiltrationtestsonpluggingmaterialswithouttheinterferenceofparticlessettlingonthefiltermediumduringtheheatupprocess.ThePPTisveryusefulinpredictinghowadrillingfluidcanformalowpermeabilityfiltercaketosealoffdepleted,underpressuredintervalsandhelppreventdifferentialsticking.TypicaldifferentialpressuresaremuchhigherthanthoseseeninstandardHTHPtesting.
ThepressurecellissimilartothoseseeninstandardHTHPfiltrationtesting,butitisinvertedwiththefiltermediumandthebackpressurereceiverontopoftheassembly.Itispressurizedwithhydraulicoilandahandpump.Afloatingpistonseparatestheoilfromthetestfluidinthecell.Thecellhasamaximumpressureratingof6,000psi.
Bothendcapsaredesignedtoaccepta1/4"NPTfitting.Theinlet,orbottom,capisfittedwithaquick-connectfortheconnectiontothehydraulicpressuremanifold.Thestandardhydraulicpressuremanifoldsareequippedwithareliefvalve.
TheLCMreceiverismountedontopofthecell.
Weight:61lbs.(27.7kg)
Dimensions:15"×25"×42"(38.1×63.5×106.7cm)
ShippingWeight:90lbs.(40.8kg)
ShippingDimensions:30"×18"×17"(76.2×45.7×43.2cm)
800WHeater
MaximumTemperature:500°F(260°C)
MaximumPressure:6,000PSI(41.4MPa)
OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/
PAGE
3
Components
#153-14GraduatedCylinder,50mL×1mL,Glass
#154-20ThermometerwithMetalDial,8"Stem,DualScale:
50°–500°F/0°–250°C
#165-44-2AntiSeizeCompound,Silver,7gPouch
#170-04COPressureUnit
2
#170-13-3O-ringforCell,Viton75D,Qty:16
#170-17O-ringforValveStem,Viton75D,Qty:6
#170-19FilterPaper,2½"(6.35cm),SpeciallyHardenedforFilter
Presses
#170-53CeramicFilterDisk,15D,50µm,Qty:10
#171-00HeatingJacket(115Volt)
#171-01HeatingJacket(230Volt)
#171-23-1SafetyPinwithLanyard
#171-90-156”CrescentAdjustableWrench
#171-190-057O-ringforValveStem,Viton90D,Qty:16
#171-190-060O-ringforCell,Viton90D,Qty:24
#171-190-061O-ringforPiston,Viton90D,Qty:12
#171-193-STestCell,StainlessSteel
#120-910-028O-ringforRuptureDisk,Viton75D,Qty:2#130-81-040RetainingRing,Qty:2
#170-13-3O-ringforCell,Viton75D,Qty:4
#170-17O-ringforValveStem,Viton75D,Qty:4#171-95T-handleforPiston
#171-190-020-SCellBody
#171-190-023LockingRing,Qty:2
#171-190-024-SPiston
#171-190-029CellCapWrench
#171-190-038A-SCellCap,Out,forCeramicDisks,1/4"NPT,316
StainlessSteel
#171-190-039SetScrewforPiston
#171-190-051-SCellCap,In,NoMesh,1/4"NPT,17-4PH#171-190-055HexKeyT-Handle9"
#171-190-056O-ringforPistonBleedPort,Viton90D,Green#171-190-057O-ringforValveStem,Viton90D,Green,Qty:4#171-190-058O-ringforRuptureDisk,Viton90D,Green,Qty:2#171-190-060O-ringforCell,Viton90D,Green,Qty:4#171-190-061O-ringforPiston,Viton90D,Green,Qty:2#171-193-504RuptureDisk,6500psi
#171-84-016HexNipple,1/4"NPT×2.5"
#171-90-07HexNipple,1/4"NPT
#171-900-025O-ringforPiston,Qty:2
#171-95T-handleForPiston
#171-99O-ringforPiston,Viton70D,Qty:2#500-SS-4-HCGHexCoupler,1/4"FNPT
#700-100-096O-ringforPistonBleedPort,Viton75D
OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/
PAGE
4
InletPressuring:
#120-00-059StreetElbow,1/4"NPT
#120-70-1-057Fitting,PortConnector,1/4"
#120-78-045Fitting,MalePortConnector,1/4"#140-50-4ReducingBushing,3/8"Male×¼"FNPT#144-15ReducingBushing,¼"MNPT×1/8"FNPT#145-00-001Tee,¼"NPT
#171-27Hose,6Feet
#171-90-07HexNipple
#171-96HandPump
#171-96-1HydraulicOil,1Quart
#171-98BallValveforInletPressureLine,¼"#171-190-062Gauge,2.5",0–6000PSI,¼"#171-193-501QuickConnectFitting,Male,1/4"NPT#171-193-502QuickConnectFitting,Female,1/4”NPT#171-193-503HexNipple,1/4"NPT×4"#171-193-505PressureReliefValve
#500-SS-4-HCGFitting,Hex,Couple,1/4"FNPT
OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/
PAGE
#171-193-101
#170-16#170-32#171-190-057#171-84-010#171-84-011#171-84-012#171-84-014#171-84-015#171-90-11#171-90-14#500-350-003#500-350-004
LCMReceiver
ValveStem
NeedleValve,Male
O-ringforValveStem,Viton90DReceiverBody
BottomCap
TopCap
Filter
O-ringforReceiverCap,Viton75DFemaleElbow,1/8”NPT
HoseBarb,1/8”NPT×1/4”
VCOFitting,Female
VCOFitting,Male
OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/
PAGE
10
Optional:
#170-33CellCapRemovalTool#170-40CarryingToolforHTHPCell#171-06SafetyShield
SafetyReadthismanualcarefullybeforeattemptingtousetheequipment.Improper
usecanresultininjuryordamagetotheequipment.
Temperature
Theheatingjacket,testcell,andpressureassemblieswillbeveryhotduringtesting.Handlethesecomponentswithcare.Nevertouchhotcomponentswithoutwearingprotectiveclothing.
Atelevatedtemperatures,thefluidinthetestcellwillexpand.Neverfillthetestcellcompletelywithfluid.Alwaysleavesomevoidspacetoallowforthermalexpansion.Refertopage
16
forrecommendedfillvolumes.
Pressure
AlwayspressurizewitheitherCarbonDioxideorNitrogen.DonotuseNitrousOxide(NO),Oxygen(O),orcompressedair.Thesegassesaredangerous
22
atelevatedtemperatures.
Themaximumworkingpressureofthetestcell(6,000PSI/41.2MPa)ismarkedonthecellbodyandcap.Neverexceedthispressure.
Equipment
Inspectallo-ringsbeforeeverytest.Discardanythatshowsignsofdamageorwear.Looksfornicks,cuts,orbrittleo-rings.Twosetsofo-ringsareincludedwiththeFilterPress.ThefirstsetismadefromViton75D.Theseo-ringsareblackandshouldbeusedfortestsupto400°Fonly.ThesecondsetismadefromViton90D.Theseo-ringsaregreenandshouldbeusedfortestsupto500°F.
CellCorrosion
Testfluidsunderhightempreatureandpressurecancorrodethecellbodyandcaps.Carefullyinspectthecellbodyandcallsforcorrosionbeforeandaftereachtest.
Somematerialsaremoresusceptibletocorrosionthanother.Also,somefluidsandadditivesaremorecorrosivethanothers.OFITEoffersavarietyofcellmaterialsfordifferentlevelsofcorrosionresistanceandcost.
Pump
ForsafeoperationoftheHydraulicPumpPressurizationsystem,makesurethepressurehasbeenreleasedandthegaugeonthepumpreadszerobefore:
Attemptingtodisconnectthepressurehosefromthecellatthequick-connect.
Attemptingtoremovethecellfromtheheatingjacket.
ReallocatingormovingthePPTinthelaboratory.
Refillingthehydraulicpump.
Performinganymaintenanceincludingtighteningleakingfittingsonthepump,hydraulicfittings,orcellassembly.
Whenrefillingorrepairingthehydraulicsystem,makesureanyspilledoiliscleaned.Oilonthefloorisveryslipperyandcancausefallsandinjury.Oilspillsonthebenchcanaccumulateandbecomeafirehazard.
QuickStart1.Placethethermometerintheheatingjacket.
Preheattheheatingjacketto10°F(6°C)abovethetesttemperature.Thepilotlightwillturnonatthetargettemperature.
Soakaceramicdiskinbasefluidforatleast10minutesbeforetesting.
Inspectallo-rings.Replaceanythatshowsignsofdamageorwear.
Applygreasetoallo-rings.
Assemblybothcellcapsandthepiston.Placeo-ringsinthegroovesaroundthecapandpiston.
Placeano-ringontheshoulderinsidethecellontheendmarked“IN”.
Applygreasetothethreadsofthecellcapsandvalvestems.
Screwtheinletcellcapassemblyintothecellbodyandtightenitcom-pletely.
Pushintheredknobontheheatingjacket.Placethecellintheheatingjacketwiththeinletsidepointingdown.
Screwtheinletpressureassemblyintotheinletcellcap.
Screwthet-handleintothepiston.
Pushthepistoninsidethecellagainsttheinletcellcap.Tightenthesetscrewonthepistonbleedvalve.
Connecttheinletpressuremanifoldtotheinletpressureassembly.
Opentheballvalveonthemanifoldandclosethepressurereleasevalveonthepump.
Strokethepumpuntilthet-handlerisesabout1.5"(3.8cm).
Unscrewthet-handlefromthepiston.
Pourthetestfluidintothecellallthewayuptotheo-ringshoulder.
Placeano-ringontheshoulderinsidethecellbody.
Placeaceramicdiskontopoftheo-ring.
Screwthecellcapassemblyintothecellbodyandtightenitcompletely.
ConnecttheLCMbottomcapassemblytothecellcapassembly.
Makesurethefilterisinplaceinsidethereceiverbottomcap.
Pourwaterintotheholeinthereceiverbottomcap.
Opentheoutletvalvetoallowexcesswatertodrain,thenclosetheoutletvalve.
Applygreasetothereceivercapo-ringsandplaceonearoundeachcap.
Screwthereceivertopcapontooneendofthereceiverbody.
Screwthereceiverbodyontothebottomreceivercap.
Screwthevalvestemintotheportonthereceivertopcap.
AttachtheCOPressureAssemblytothetopvalvestemandsecureit2
withasafetypin.
Pullouttheredknobontheheatingjacketandlowerthecell.Rotatethecelluntilitseats.
Movethethermometertothecellbody.
PlaceaCObulbintheCOpressureassembly.Setthepressuretotheappropriatebackpressureforyourtest.22
Strokethepumptoapplythesamepressuretothecell.
Whenthecellhasreachedthetesttemperature,strokethepumptoapplytheworkingtestpressuretothecell.
CollectfiltratebyopeningtheneedlevalveontheLCMReceiver.
Attheendofthetest,turnofftheheatingjacket.
Allowthecelltocool.
ClosetheregulatorontheCOpressureassembly.2
Openthepressurereleasevalveonthepumptoreleasepressureinsidethecell.
UnscrewtheVCOfittingtodisconnecttheLCMReceiverfromthecellcap.
Disconnecttheinletpressuremanifoldfromtheinletpressureassembly.
Removethecellfromtheheatingjacketandsetituprighttodisassemble.
Reconnectthepressuremanifoldtotheinletvalvepressureassembly.
Removetheoutletcellcapassembly.
Removetheceramicdiskandsavethefiltercakeforlateranalysis.
Discardanyremainingtestfluid.
Screwthet-handleintothepistonandpushthepistontothebottomofthecell.
Closethepressurereleasevalveonthepumpandtheballvalveonthepressuremanifold.
Disconnectthepressuremanifoldfromtheinletpressureassembly.
Removetheinletpressureassemblyandinletcellcapassembly.
Cleananddrytheentirecellassembly.
Preparation1.Plugtheheatingjacketintoanappropriatepowersource.Placeather-
mometer(#154-20)intotheheatingwellandpreheatto10°F(6°C)abovethetesttemperature.Apilotlightwillcomeonwhentheheatingjacketreachesthetemperaturesetbythecontrolknob.
2.Beforeusingtheceramicdisk,soakitforatleast10minutesinbasefluid.Usewaterforfreshwater-basedfluids,brineforsaltwater-basedfluids,dieselforoil-basedfluids,andasyntheticbaseforsynthetic-basedfluids.Neverreuseadiskexceptforreturnpermeabilitystudies.Belowisalistofceramicdisksavailable:
OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/
PAGE
#170-55#170-53-2#170-53-3#170-51#170-53#170-53-1#170-53-4
CeramicFilterDisk,775milli-darcy,10micron,2½"×¼"CeramicFilterDisk,850milli-darcy,12micron,2½"×¼"CeramicFilterDisk,3darcy,20micron,2½"×¼"CeramicFilterDisk,8darcy,40micron,2½"×¼"CeramicFilterDisk,15darcy,50micron,2½"×¼"CeramicFilterDisk,20darcy,55micron,2½"×¼"CeramicFilterDisk,40darcy,120micron,2½"×¼"
OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/
PAGE
11
CellAssembly
Carefullyinspectallo-rings.Replaceanythatshowsignsofdamageorwear.
Placeathinfilmofsiliconegreaseonallo-rings.Replaceallo-ringsafteranytestabove350°F(176.6°C).
Ifthecellcapsarenotalreadyassembled,refertopage
20
forassem-blyinstructions.
Setthecellbodyonthestandwiththeendmarked“IN”pointingup.Placeano-ring(#170-13-3)ontheshoulderinsidethecellbodyandoneinthegroovearoundthecellcap.
O-ring
Applygreasetothethreadsofthecellcaps.
Screwtheinletcellcapassemblyintothecellbody.
Pushintheredknobontheheatingjacket.Thismovesthecellrestplungerintopositiontosupportthecell.
Placethecellintotheheatingjacketwiththeinletsidepointingdown.
OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/
PAGE
22
Screwtheinletpressureassemblyintotheinletcapandtightenitcom-pletely.
Quick-ConnectFittingPressureAssembly
InletCapAssembly
Ifthepistonisnotalreadyassembled,refertopage
21
forassemblyinstructions.Thesetscrewonthepistonbleedervalveshouldbeloose.
Placetwoo-rings(#171-99)intothegroovesaroundthepiston.
ScrewtheT-handleintothepiston.
Pushthepistoninsidethecellagainsttheinletcellcap.
Tightenthesetscrewonthepistonbleedervalvecompletely.
Connecttheinletpressuremanifoldtotheinletpressureassembly.
Makesurethequick-connectfittingsarecompletelyengaged.Pulldownhardontheringonthefemalefittinguntilitclicksintoplace.
Quick-ConnectFitting
InletBallValve
InletPressureManifold
Opentheinletballvalve.
Closethepressurereleasevalveonthepumpbytighteningitclockwise.
StrokethepumpuntiltheT-handleonthepistonrisesapproximately1½"(3.8cm).
Itmaybehelpfultosetarulerontheo-ringshoulderinsidethecell.ThiswillhelpyouseehowfartheT-handlehasrisen.
UnscrewtheT-handlefromthepiston.
Preparethetestfluid.
Carefullypourthetestfluidintothecell.Thefluidlevelshouldbejustbelowtheo-ringshoulder.
Becarefulnottogetfluidontheo-ringshoulder.
Placeano-ringontheshoulderinsidethecellbody.
Placeaceramicdiskoracircleoffilterpaperontopoftheo-ring.
Screwthecellcapassembly(cellcapandmaleVCOfitting)intothecellbodyandtightencompletely.
CellCapAssembly
ConnecttheLCMReceiverbottomcapassembly(bottomcap,needlevalve,andfemaleVCOfitting)tothemaleVCOfittingonthecellcapas-sembly.Makesurethefilterisinplaceinsidethereceiverbottomcap.
Filter(#171-84-014)
O-ring(#171-84-015)
Thespacebetweenthefiltermediaandthereceiverbottomcapshouldbefilledwithwatertoensurethatthevolumeoffiltratepassingthroughthefilterwilldisplaceanequalvolumeoffiltrateintothereceiver.
PourenoughwaterintotheholeintheLCMReceiverbottomcaptofillthevoidspace.
Opentheneedlevalveandallowtheexcesswatertodrain.
Closetheneedvalve.
Applyathincoatofgreasetothereceivercapo-rings(#171-84-015).
Placeoneo-ringaroundeachcap.
Screwthetopcapintooneendofthecellbody(theendsofthebodyareinterchangeable).
Screwthereceiverbodyontothebottomreceivercap.
Screwavalvestemintotheportinthetopreceivercap.
AttachedtheCO2PressureAssembly(#170-04)tothetopvalvestemandsecureitwiththesafetypin(#171-23-1).
Holdtheoutletpressureassemblywithonehandandpullthestopontheheatingjacketoutofthewaytolowerthecellfullyinsidetheheatingjacket.
Rotatethecelluntilitlocksinplaceoverthealignmentpininthebottomoftheheatingjacket.
Placeametaldialthermometer(#154-20)inthetopofthecellinthesmallhole.
T-Screw
NeedleValve(#170-32)SafetyPin(#171-23-1)
COPressureReceiver
2
TestingStartingaTest
UnscrewtheT-screwontheCOpressureassemblytomakesuretheregulatoriscompletelyclosed.2
PlaceaCObulbinthebarrelandscrewitontothepressureassembly.ThiswillpuncturetheCO2bulb.
2
TurntheT-screwclockwisetosetthebackpressure.Refertothechartbelowtodeterminetheminimumrecommendedbackpressureforyourtesttemperature.
Strokethepumptoapplythesamepressuretothecell.
Makesurethepressurereleasevalveonthepumpisclosedandtheballvalveontheinletmanifoldisopen.
IftheLCMfailstoplugthefiltermedia,itisunlikelythepressureinthecellwillbuild.Ifthecellpressurehasnotincreasedafterapproximately20strokesofthepump,stopthetestandrecordtheresultsas“TotalFluidLoss”.
Throughoutthetest,usethepumptomaintainthepressuredifferential.
RecommendedMinimumBackPressure
TestTemperature
VaporPressure
MinimumBackPressure
°F
°C
psi
kPa
psi
kPa
200-299
95-149
12.1-67
84-462
100
700
300-374
150-189
67-184
462-1269
200
1400
375-399
190-199
184-247
1269-1704
275
1900
400-424*
200-219
247-326
1704-2245
350
2500
425-450*
220-230
326-422
2245-2912
450
3100
*Fortestsabove400°F,usegreenViton90Do-rings.
Periodicallycheckthethermometerinthetestcellandadjustthethermo-statasneeded.
Whilethecellisheating,thepressureinsidewillriseduetothermalexpansion.Usethepressurereleasevalveonthepumptopreventover-pressurization.Maintainthepressureonthefluiduntilthetempera-turehasstabilized.Theheatingtimeofthesampleshouldneverexceedonehour.
Tocollectfiltrate,holdagraduatedcylinderuptotheoutletportontheLCMReceiverandslowlyopentheneedlevalve.Closethevalveassoonasyouhavecollectedthefiltrate.
Collectfiltrate15secondsafterinitiatingfiltrationtoensurethereisfiltra-tioncontrol.
Continuecollectingfiltratethroughoutthetest.Ataminimum,filtrateshouldbecollectedat15seconds,7.5minutes,and30minutes.
Ifthebackpressurerisesduringthetest,collectsomefiltrateandleavethevalveopenlongenoughtoreducethepressure.
EndingaTest
After30minutes,closetheoutletportonthereceiverandturnofftheheatingjacket.
Allowthecelltocooltoroomtemperaturebeforedisassemblingit.
Afterthecellhascooled,slowlyopenthepressurereleasevalveonthepump.Thiswillallowhydraulicoiltoflowbackintothepump.
Opentheoutletportonthereceivertocollectanyremainingfiltrate.
ClosetheregulatorontheCOpressureassemblyandreleaseanyre-mainingpressurebyopeningthesafetybleedervalve.2
RemovetheCOpressureassemblyfromtheLCMReceiver.
2
UnscrewtheLCMReceiverbodyfromthebottomreceivercap.
Disconnecttheinletpressuremanifoldfromtheinletpressureassembly(quickconnectfitting).
Asmallamountofhydraulicoilmaybereleased.
Removethecellfromtheheatingjacketandplaceitonastandfordisas-sembly.
Reconnecttheinletpressuremanifoldtotheinletpressureassembly(quickconnectfitting)
Unscrewandremovetheoutletcellcapassembly.
Removetheceramicdiskorfilterpaperandsaveitforanalysis.Discardanyremainingtestfluid.
Iftheceramicdiskdoesnoteasilycomeoutofthecell:
Closethepressurereliefvalveonthepump.
Strokethepumpuntilthepressurepushestheceramicdiskoutofthecell.
Thenre-openthepressurereliefvalveonthepump.
ScrewtheT-handleintothepistonontheoutletside.
Manuallypushthepistontothebottomofthecell.Thiswillforceanyre-maininghydraulicfluidbackintothepump.
Closethepressurereleasevalveonthepumpandtheballvalveonthepressuremanifold.
Disconnectthepressuremanifoldfromtheinletpressureassembly.
Removetheinletpressureassembly,cellcapassembly,andpiston.Beawarethatsomehydraulicfluidwillremaininthecell.
CleananddrytheentirecellandLCMReceiverassemblies.Paycloseat-tentiontothethreads.Alsomakesuretocleantheoutletvalveassembly.Inspectallo-ringsandreplaceanythatshowsignsofdamageorwear.
DataFiltrateVolume2
TheHTHPfilterpresshasafiltrationareaof3.55in2(22.9cm).Thisishalftheareaofastandardfiltrationtest,whichis7.1in2(45.8cm2).Tocomparetheresultsofthistesttoastandardfiltrationtest,doublethetotalfiltratevol-umecollected.
V=2(V)
F30Where:
V=StandardFiltrateVolume(mL)
VF=Filtratevolumecollectedafter7.5minutes
7.5
SpurtLoss(Optional):
SpurtLossistheamountoffiltratecollectedbeforethefiltercakehashadachancetoformandisexpressedinmillimeters.Tocalculatethespurtloss,usethefollowingequation:
V=2[V-(V-V)]=2(2V-V)=4V-2V
17.5307.57.5307.530Where:
V=SpurtLoss
1
V=Filtratevolumecollectedafter7.5minutes
7.5
V=Filtratevolumecollectedafter30minutes
30
FilterCake
Washthefiltercakeonthepaperwithagentlestreamofwater.Measureandreportthethicknessofthefiltercaketothenearest1/32in(0.8mm).Arulerwiththe“zeromark”attheveryedgeoftherulerisusefulhere.Cakedescrip-tionsmaybesubjectiveandsuchnotationssuchashard,soft,rubbery,andfine,etc.conveyadequateinformationoncakequality.
CellCap1.Placethelockingring(#171-190-023)aroundthecap.Assembly2.Placetheretainingring(#130-81-040)intothegroovearoundtheoutside
ofthecap.Makesureitengagescompletelyaroundthecircle.
Thecapshouldturnfreelyinsidethelockingring.
Cap
RetainingRing
LockingRing
O-ring
Piston1.Placearupturedisko-ring(#120-910-028)intotherupturediskport.Assembly2.Screwtherupturediskintotheport.
Placeano-ring(#700-100-096)intothebleedport.
Screwthesetscrew(#171-190-039)intothebleedport.Unscrewitonefullturn.
Placetwoo-rings(#171-900-025)intheo-ringgroovesaroundtheout-sideofthepiston.
RuptureDiskSetScrewO-ring
O-ring
Maintenance1.Thoroughlycleananddryallcomponentswithwaterandsoap(orappro-
priatesolvent).
Periodicallycheckthecellassemblyforleaks.Pressurizethecellandim-merseitinwater.Lookforbubbles.
Iftheregulatorlosespressureorsteadilyincreasespressure,replacetheseatassemblyanddiaphragm.UsetheRegulatorRepairKit(#143-07).Alwaysreplacetherubberdiaphragm(#143-00-1,soldseparately).Toreplacetheseatassembly:
Unscrewthespringcase(housingcover).Thismayrequireastrapwrench.
Removethespringcase.
Removetherubberdiaphragmfrominsidethespringcase.
Removethethrustplate.
Usingawrench,loosenandremovethebrassretainer.
Thethrustpinandseatarenowexposed.Removethemfromthebase.
Replacethespring.
Replacetheseatholder.
ReplacethethrustpinandtheTeflonseat,whichcanbeattachedbeforeinsertion.
Replacethebrassretainerwithawrench.
Replacethethrustplatewiththecurvededgesdownward.
Placeanewrubberdiaphragminsidethespringcase.
Replacethespringcaseandhandtighten.
DiaphragmRepairKit(#143-00-1)(#143-00-1)
PowerCord
Checkthepowercordforinsulationwearandlooseconnectionsneartheheatingjacketandplug.
Placetheheatingjacketnofartherfromtheheatingjacketthanthelengthofthepowercord.
Keepthepowercordawayfromthehotsurfaceoftheheatingjacket.
Installingwiring,powercords,orelectricalconnectorswillvoidthewarranty.
RegulatorMaintenanceandTroubleshooting
Symptoms
Cause:Resolution
Gasleakattheregulatoroutletwhentheadjustingscrewisloosenedfullycounterclockwise
Seatleakor*creep:Repairtheregulator
Outletpressureincreaseswhiledownstreamvalvesareclosed
Seatleakor*creep:Repairtheregulator
Gasleakfromthespringhousingcase
Diaphragmfailure:Repairtheregulator
Excessdropinoutletpressurewiththeregulatorflowopen
Blockedseatassemblyorinletfilter:Repairtheregulator
Gasleakfromanypipethreadjoint
Loosefitting:Removetheconnection.Cleantheaffectedsurfaces.ReapplyTeflontapeandtighten.
Gasleakfromreliefvalve
Faultyreliefvalve:replacethevalve.Seatleakor*creep:Repairtheregulator
Inconsistentrepeatreadings
Seatsticking:Repairtheregulator.Badpressuregauge:Replacethegauge.
Gaugedoesnotreturntozerowithnopressureappliedtotheregulator.
Gaugehasphysicaldamage:Replacethegauge.
*Creepisanincreaseinoutletpressurethatoccurswhenpressureescapesevenwhenthevalveisclosed.Regulatorseatscanbecompromisedbyparticlesintheprocessstreamwhichcancauseminorimperfectionsinthesealingsurface.Thehighflowandsmallorificecreatedduringpressureregulationcombinetoturnaverysmallparticleintoafastprojectile.Thisprojectilecannickthesealingsurfaceoftheseatandcauseleaks.Filteringparticulatesfromtheprocessstreamshouldbeahighpriority,andasmallfiltercanreducethepotentialforcreepandincreasethelifeexpectancyandaccuracyoftheregulator.
OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/
PAGE
23
DiagramsPermeabilityPlugging
Tester
Gauge,1500PSI
(#171-34)
Regulator(#170-08)Barrel(#143-03)
ManifoldBlock
(#170-20)SafetyPinwithLanyard
(#171-23-1)
NeedleValveValveStem(#170-16)
(#170-32)
TopCap(#171-84-012)O-ring(#171-84-015)
Body(#171-84-010)
NeedleValve
(#170-32)
Filter(#171-84-014)BottomCapO-ring(#171-84-015)
(#171-84-011)
VCOFitting,Female(#500-350-003)
VCOFitting,Male(#500-350-004)
TestCell(#171-193-6K-S)
TestFluid
O-ring,Viton
Piston(75D:#171-99)(#171-190-024-S)(90D:#171-190-061)
HydraulicOil(#171-96-1)
Qui
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2023年耐辐照玻璃棉项目安全风险评价报告
- 云南省昆明市官渡区一中2020-2021学年高一语文上学期期中试题(含解析)
- 2021-2022学年南省洛阳市偃师县重点名校中考数学押题试卷含解析
- 2024-2034年中国婴儿衣物柔顺剂行业市场全景评估及投资前景展望报告
- 【全国百强校首发】河北省武邑中学2023-2024学年中考猜题物理试卷含解析
- 2024-2034年中国口译培训行业市场发展监测及投资战略咨询报告
- 2024-2034年中国半夏行业市场发展监测及投资战略规划报告
- 广西陆川县联考2024届中考数学全真模拟试卷含解析
- 广东省珠海市香洲区重点中学2024年中考押题数学预测卷含解析
- 2024-2034年中国儿童服装市场竞争格局分析及投资方向研究报告
- 平面四杆机构的死点
- 2023年高考新课标文综全国卷一(Word版含答案)
- 输电线路工程强制性条文执行记录表安全
- 注册安全工程师真注册安全工程师真题集
- 二十四节气之小满PPT模板
- 啦啦操训练计划
- 襄阳市基本医疗保险特殊药品使用审核表
- 电影音乐欣赏知到章节答案智慧树2023年华南农业大学
- 云改数转练习考题(题库7)附有答案
- 剥豆机的总体设计
- 小学数学 解方程500题 4
评论
0/150
提交评论