PermeabilityPluggingTesterwithLCM

Receiver,6000psi

#171-193-6K:115Volt#171-193-6K-1:230Volt

InstructionManual

Updated6/14/2019Ver.4

OFITestingEquipment,Inc.

11302SteeplecrestDr.·Houston,Texas·77065·U.S.A.Tele:832.320.7300·Fax:713.880.9886·

©CopyrightOFITE2017

OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/

PAGE

1

TableofContents

Intro2Description2Specifications2

Components3

Safety5

QuickStart7

Preparation10

CellAssembly11

Testing16

Data19

CellCapAssembly20

PistonAssembly21

Maintenance22

Diagrams24PermeabilityPluggingTester24

TestCell25

WarrantyandReturnPolicy26

OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/

PAGE

2

Intro

DescriptionSpecifications

ThePermeabilityPluggingTester(PPT)isamodificationofthestandard500mLHTHPFilterpress.Itmaybeusedinthefieldorinalaboratoryenvironment.Theinstrumentisusefulforperformingfiltrationtestsonpluggingmaterialswithouttheinterferenceofparticlessettlingonthefiltermediumduringtheheatupprocess.ThePPTisveryusefulinpredictinghowadrillingfluidcanformalowpermeabilityfiltercaketosealoffdepleted,underpressuredintervalsandhelppreventdifferentialsticking.TypicaldifferentialpressuresaremuchhigherthanthoseseeninstandardHTHPtesting.

ThepressurecellissimilartothoseseeninstandardHTHPfiltrationtesting,butitisinvertedwiththefiltermediumandthebackpressurereceiverontopoftheassembly.Itispressurizedwithhydraulicoilandahandpump.Afloatingpistonseparatestheoilfromthetestfluidinthecell.Thecellhasamaximumpressureratingof6,000psi.

Bothendcapsaredesignedtoaccepta1/4"NPTfitting.Theinlet,orbottom,capisfittedwithaquick-connectfortheconnectiontothehydraulicpressuremanifold.Thestandardhydraulicpressuremanifoldsareequippedwithareliefvalve.

TheLCMreceiverismountedontopofthecell.

Weight:61lbs.(27.7kg)

Dimensions:15"×25"×42"(38.1×63.5×106.7cm)

ShippingWeight:90lbs.(40.8kg)

ShippingDimensions:30"×18"×17"(76.2×45.7×43.2cm)

800WHeater

MaximumTemperature:500°F(260°C)

MaximumPressure:6,000PSI(41.4MPa)

OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/

PAGE

3

Components

#153-14GraduatedCylinder,50mL×1mL,Glass

#154-20ThermometerwithMetalDial,8"Stem,DualScale:

50°–500°F/0°–250°C

#165-44-2AntiSeizeCompound,Silver,7gPouch

#170-04COPressureUnit

2

#170-13-3O-ringforCell,Viton75D,Qty:16

#170-17O-ringforValveStem,Viton75D,Qty:6

#170-19FilterPaper,2½"(6.35cm),SpeciallyHardenedforFilter

Presses

#170-53CeramicFilterDisk,15D,50µm,Qty:10

#171-00HeatingJacket(115Volt)

#171-01HeatingJacket(230Volt)

#171-23-1SafetyPinwithLanyard

#171-90-156”CrescentAdjustableWrench

#171-190-057O-ringforValveStem,Viton90D,Qty:16

#171-190-060O-ringforCell,Viton90D,Qty:24

#171-190-061O-ringforPiston,Viton90D,Qty:12

#171-193-STestCell,StainlessSteel

#120-910-028O-ringforRuptureDisk,Viton75D,Qty:2#130-81-040RetainingRing,Qty:2

#170-13-3O-ringforCell,Viton75D,Qty:4

#170-17O-ringforValveStem,Viton75D,Qty:4#171-95T-handleforPiston

#171-190-020-SCellBody

#171-190-023LockingRing,Qty:2

#171-190-024-SPiston

#171-190-029CellCapWrench

#171-190-038A-SCellCap,Out,forCeramicDisks,1/4"NPT,316

StainlessSteel

#171-190-039SetScrewforPiston

#171-190-051-SCellCap,In,NoMesh,1/4"NPT,17-4PH#171-190-055HexKeyT-Handle9"

#171-190-056O-ringforPistonBleedPort,Viton90D,Green#171-190-057O-ringforValveStem,Viton90D,Green,Qty:4#171-190-058O-ringforRuptureDisk,Viton90D,Green,Qty:2#171-190-060O-ringforCell,Viton90D,Green,Qty:4#171-190-061O-ringforPiston,Viton90D,Green,Qty:2#171-193-504RuptureDisk,6500psi

#171-84-016HexNipple,1/4"NPT×2.5"

#171-90-07HexNipple,1/4"NPT

#171-900-025O-ringforPiston,Qty:2

#171-95T-handleForPiston

#171-99O-ringforPiston,Viton70D,Qty:2#500-SS-4-HCGHexCoupler,1/4"FNPT

#700-100-096O-ringforPistonBleedPort,Viton75D

OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/

PAGE

4

InletPressuring:

#120-00-059StreetElbow,1/4"NPT

#120-70-1-057Fitting,PortConnector,1/4"

#120-78-045Fitting,MalePortConnector,1/4"#140-50-4ReducingBushing,3/8"Male×¼"FNPT#144-15ReducingBushing,¼"MNPT×1/8"FNPT#145-00-001Tee,¼"NPT

#171-27Hose,6Feet

#171-90-07HexNipple

#171-96HandPump

#171-96-1HydraulicOil,1Quart

#171-98BallValveforInletPressureLine,¼"#171-190-062Gauge,2.5",0–6000PSI,¼"#171-193-501QuickConnectFitting,Male,1/4"NPT#171-193-502QuickConnectFitting,Female,1/4”NPT#171-193-503HexNipple,1/4"NPT×4"#171-193-505PressureReliefValve

#500-SS-4-HCGFitting,Hex,Couple,1/4"FNPT

OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/

PAGE

#171-193-101

#170-16#170-32#171-190-057#171-84-010#171-84-011#171-84-012#171-84-014#171-84-015#171-90-11#171-90-14#500-350-003#500-350-004

LCMReceiver

ValveStem

NeedleValve,Male

O-ringforValveStem,Viton90DReceiverBody

BottomCap

TopCap

Filter

O-ringforReceiverCap,Viton75DFemaleElbow,1/8”NPT

HoseBarb,1/8”NPT×1/4”

VCOFitting,Female

VCOFitting,Male

OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/

PAGE

10

Optional:

#170-33CellCapRemovalTool#170-40CarryingToolforHTHPCell#171-06SafetyShield

SafetyReadthismanualcarefullybeforeattemptingtousetheequipment.Improper

usecanresultininjuryordamagetotheequipment.

Temperature

Theheatingjacket,testcell,andpressureassemblieswillbeveryhotduringtesting.Handlethesecomponentswithcare.Nevertouchhotcomponentswithoutwearingprotectiveclothing.

Atelevatedtemperatures,thefluidinthetestcellwillexpand.Neverfillthetestcellcompletelywithfluid.Alwaysleavesomevoidspacetoallowforthermalexpansion.Refertopage

16

forrecommendedfillvolumes.

Pressure

AlwayspressurizewitheitherCarbonDioxideorNitrogen.DonotuseNitrousOxide(NO),Oxygen(O),orcompressedair.Thesegassesaredangerous

22

atelevatedtemperatures.

Themaximumworkingpressureofthetestcell(6,000PSI/41.2MPa)ismarkedonthecellbodyandcap.Neverexceedthispressure.

Equipment

Inspectallo-ringsbeforeeverytest.Discardanythatshowsignsofdamageorwear.Looksfornicks,cuts,orbrittleo-rings.Twosetsofo-ringsareincludedwiththeFilterPress.ThefirstsetismadefromViton75D.Theseo-ringsareblackandshouldbeusedfortestsupto400°Fonly.ThesecondsetismadefromViton90D.Theseo-ringsaregreenandshouldbeusedfortestsupto500°F.

CellCorrosion

Testfluidsunderhightempreatureandpressurecancorrodethecellbodyandcaps.Carefullyinspectthecellbodyandcallsforcorrosionbeforeandaftereachtest.

Somematerialsaremoresusceptibletocorrosionthanother.Also,somefluidsandadditivesaremorecorrosivethanothers.OFITEoffersavarietyofcellmaterialsfordifferentlevelsofcorrosionresistanceandcost.

Pump

ForsafeoperationoftheHydraulicPumpPressurizationsystem,makesurethepressurehasbeenreleasedandthegaugeonthepumpreadszerobefore:

Attemptingtodisconnectthepressurehosefromthecellatthequick-connect.

Attemptingtoremovethecellfromtheheatingjacket.

ReallocatingormovingthePPTinthelaboratory.

Refillingthehydraulicpump.

Performinganymaintenanceincludingtighteningleakingfittingsonthepump,hydraulicfittings,orcellassembly.

Whenrefillingorrepairingthehydraulicsystem,makesureanyspilledoiliscleaned.Oilonthefloorisveryslipperyandcancausefallsandinjury.Oilspillsonthebenchcanaccumulateandbecomeafirehazard.

QuickStart1.Placethethermometerintheheatingjacket.

Preheattheheatingjacketto10°F(6°C)abovethetesttemperature.Thepilotlightwillturnonatthetargettemperature.

Soakaceramicdiskinbasefluidforatleast10minutesbeforetesting.

Inspectallo-rings.Replaceanythatshowsignsofdamageorwear.

Applygreasetoallo-rings.

Assemblybothcellcapsandthepiston.Placeo-ringsinthegroovesaroundthecapandpiston.

Placeano-ringontheshoulderinsidethecellontheendmarked“IN”.

Applygreasetothethreadsofthecellcapsandvalvestems.

Screwtheinletcellcapassemblyintothecellbodyandtightenitcom-pletely.

Pushintheredknobontheheatingjacket.Placethecellintheheatingjacketwiththeinletsidepointingdown.

Screwtheinletpressureassemblyintotheinletcellcap.

Screwthet-handleintothepiston.

Pushthepistoninsidethecellagainsttheinletcellcap.Tightenthesetscrewonthepistonbleedvalve.

Connecttheinletpressuremanifoldtotheinletpressureassembly.

Opentheballvalveonthemanifoldandclosethepressurereleasevalveonthepump.

Strokethepumpuntilthet-handlerisesabout1.5"(3.8cm).

Unscrewthet-handlefromthepiston.

Pourthetestfluidintothecellallthewayuptotheo-ringshoulder.

Placeano-ringontheshoulderinsidethecellbody.

Placeaceramicdiskontopoftheo-ring.

Screwthecellcapassemblyintothecellbodyandtightenitcompletely.

ConnecttheLCMbottomcapassemblytothecellcapassembly.

Makesurethefilterisinplaceinsidethereceiverbottomcap.

Pourwaterintotheholeinthereceiverbottomcap.

Opentheoutletvalvetoallowexcesswatertodrain,thenclosetheoutletvalve.

Applygreasetothereceivercapo-ringsandplaceonearoundeachcap.

Screwthereceivertopcapontooneendofthereceiverbody.

Screwthereceiverbodyontothebottomreceivercap.

Screwthevalvestemintotheportonthereceivertopcap.

AttachtheCOPressureAssemblytothetopvalvestemandsecureit2

withasafetypin.

Pullouttheredknobontheheatingjacketandlowerthecell.Rotatethecelluntilitseats.

Movethethermometertothecellbody.

PlaceaCObulbintheCOpressureassembly.Setthepressuretotheappropriatebackpressureforyourtest.22

Strokethepumptoapplythesamepressuretothecell.

Whenthecellhasreachedthetesttemperature,strokethepumptoapplytheworkingtestpressuretothecell.

CollectfiltratebyopeningtheneedlevalveontheLCMReceiver.

Attheendofthetest,turnofftheheatingjacket.

Allowthecelltocool.

ClosetheregulatorontheCOpressureassembly.2

Openthepressurereleasevalveonthepumptoreleasepressureinsidethecell.

UnscrewtheVCOfittingtodisconnecttheLCMReceiverfromthecellcap.

Disconnecttheinletpressuremanifoldfromtheinletpressureassembly.

Removethecellfromtheheatingjacketandsetituprighttodisassemble.

Reconnectthepressuremanifoldtotheinletvalvepressureassembly.

Removetheoutletcellcapassembly.

Removetheceramicdiskandsavethefiltercakeforlateranalysis.

Discardanyremainingtestfluid.

Screwthet-handleintothepistonandpushthepistontothebottomofthecell.

Closethepressurereleasevalveonthepumpandtheballvalveonthepressuremanifold.

Disconnectthepressuremanifoldfromtheinletpressureassembly.

Removetheinletpressureassemblyandinletcellcapassembly.

Cleananddrytheentirecellassembly.

Preparation1.Plugtheheatingjacketintoanappropriatepowersource.Placeather-

mometer(#154-20)intotheheatingwellandpreheatto10°F(6°C)abovethetesttemperature.Apilotlightwillcomeonwhentheheatingjacketreachesthetemperaturesetbythecontrolknob.

2.Beforeusingtheceramicdisk,soakitforatleast10minutesinbasefluid.Usewaterforfreshwater-basedfluids,brineforsaltwater-basedfluids,dieselforoil-basedfluids,andasyntheticbaseforsynthetic-basedfluids.Neverreuseadiskexceptforreturnpermeabilitystudies.Belowisalistofceramicdisksavailable:

OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/

PAGE

#170-55#170-53-2#170-53-3#170-51#170-53#170-53-1#170-53-4

CeramicFilterDisk,775milli-darcy,10micron,2½"×¼"CeramicFilterDisk,850milli-darcy,12micron,2½"×¼"CeramicFilterDisk,3darcy,20micron,2½"×¼"CeramicFilterDisk,8darcy,40micron,2½"×¼"CeramicFilterDisk,15darcy,50micron,2½"×¼"CeramicFilterDisk,20darcy,55micron,2½"×¼"CeramicFilterDisk,40darcy,120micron,2½"×¼"

OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/

PAGE

11

CellAssembly

Carefullyinspectallo-rings.Replaceanythatshowsignsofdamageorwear.

Placeathinfilmofsiliconegreaseonallo-rings.Replaceallo-ringsafteranytestabove350°F(176.6°C).

Ifthecellcapsarenotalreadyassembled,refertopage

20

forassem-blyinstructions.

Setthecellbodyonthestandwiththeendmarked“IN”pointingup.Placeano-ring(#170-13-3)ontheshoulderinsidethecellbodyandoneinthegroovearoundthecellcap.

O-ring

Applygreasetothethreadsofthecellcaps.

Screwtheinletcellcapassemblyintothecellbody.

Pushintheredknobontheheatingjacket.Thismovesthecellrestplungerintopositiontosupportthecell.

Placethecellintotheheatingjacketwiththeinletsidepointingdown.

OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/

PAGE

22

Screwtheinletpressureassemblyintotheinletcapandtightenitcom-pletely.

Quick-ConnectFittingPressureAssembly

InletCapAssembly

Ifthepistonisnotalreadyassembled,refertopage

21

forassemblyinstructions.Thesetscrewonthepistonbleedervalveshouldbeloose.

Placetwoo-rings(#171-99)intothegroovesaroundthepiston.

ScrewtheT-handleintothepiston.

Pushthepistoninsidethecellagainsttheinletcellcap.

Tightenthesetscrewonthepistonbleedervalvecompletely.

Connecttheinletpressuremanifoldtotheinletpressureassembly.

Makesurethequick-connectfittingsarecompletelyengaged.Pulldownhardontheringonthefemalefittinguntilitclicksintoplace.

Quick-ConnectFitting

InletBallValve

InletPressureManifold

Opentheinletballvalve.

Closethepressurereleasevalveonthepumpbytighteningitclockwise.

StrokethepumpuntiltheT-handleonthepistonrisesapproximately1½"(3.8cm).

Itmaybehelpfultosetarulerontheo-ringshoulderinsidethecell.ThiswillhelpyouseehowfartheT-handlehasrisen.

UnscrewtheT-handlefromthepiston.

Preparethetestfluid.

Carefullypourthetestfluidintothecell.Thefluidlevelshouldbejustbelowtheo-ringshoulder.

Becarefulnottogetfluidontheo-ringshoulder.

Placeano-ringontheshoulderinsidethecellbody.

Placeaceramicdiskoracircleoffilterpaperontopoftheo-ring.

Screwthecellcapassembly(cellcapandmaleVCOfitting)intothecellbodyandtightencompletely.

CellCapAssembly

ConnecttheLCMReceiverbottomcapassembly(bottomcap,needlevalve,andfemaleVCOfitting)tothemaleVCOfittingonthecellcapas-sembly.Makesurethefilterisinplaceinsidethereceiverbottomcap.

Filter(#171-84-014)

O-ring(#171-84-015)

Thespacebetweenthefiltermediaandthereceiverbottomcapshouldbefilledwithwatertoensurethatthevolumeoffiltratepassingthroughthefilterwilldisplaceanequalvolumeoffiltrateintothereceiver.

PourenoughwaterintotheholeintheLCMReceiverbottomcaptofillthevoidspace.

Opentheneedlevalveandallowtheexcesswatertodrain.

Closetheneedvalve.

Applyathincoatofgreasetothereceivercapo-rings(#171-84-015).

Placeoneo-ringaroundeachcap.

Screwthetopcapintooneendofthecellbody(theendsofthebodyareinterchangeable).

Screwthereceiverbodyontothebottomreceivercap.

Screwavalvestemintotheportinthetopreceivercap.

AttachedtheCO2PressureAssembly(#170-04)tothetopvalvestemandsecureitwiththesafetypin(#171-23-1).

Holdtheoutletpressureassemblywithonehandandpullthestopontheheatingjacketoutofthewaytolowerthecellfullyinsidetheheatingjacket.

Rotatethecelluntilitlocksinplaceoverthealignmentpininthebottomoftheheatingjacket.

Placeametaldialthermometer(#154-20)inthetopofthecellinthesmallhole.

T-Screw

NeedleValve(#170-32)SafetyPin(#171-23-1)

COPressureReceiver

2

TestingStartingaTest

UnscrewtheT-screwontheCOpressureassemblytomakesuretheregulatoriscompletelyclosed.2

PlaceaCObulbinthebarrelandscrewitontothepressureassembly.ThiswillpuncturetheCO2bulb.

2

TurntheT-screwclockwisetosetthebackpressure.Refertothechartbelowtodeterminetheminimumrecommendedbackpressureforyourtesttemperature.

Strokethepumptoapplythesamepressuretothecell.

Makesurethepressurereleasevalveonthepumpisclosedandtheballvalveontheinletmanifoldisopen.

IftheLCMfailstoplugthefiltermedia,itisunlikelythepressureinthecellwillbuild.Ifthecellpressurehasnotincreasedafterapproximately20strokesofthepump,stopthetestandrecordtheresultsas“TotalFluidLoss”.

Throughoutthetest,usethepumptomaintainthepressuredifferential.

RecommendedMinimumBackPressure

TestTemperature

VaporPressure

MinimumBackPressure

°F

°C

psi

kPa

psi

kPa

200-299

95-149

12.1-67

84-462

100

700

300-374

150-189

67-184

462-1269

200

1400

375-399

190-199

184-247

1269-1704

275

1900

400-424*

200-219

247-326

1704-2245

350

2500

425-450*

220-230

326-422

2245-2912

450

3100

*Fortestsabove400°F,usegreenViton90Do-rings.

Periodicallycheckthethermometerinthetestcellandadjustthethermo-statasneeded.

Whilethecellisheating,thepressureinsidewillriseduetothermalexpansion.Usethepressurereleasevalveonthepumptopreventover-pressurization.Maintainthepressureonthefluiduntilthetempera-turehasstabilized.Theheatingtimeofthesampleshouldneverexceedonehour.

Tocollectfiltrate,holdagraduatedcylinderuptotheoutletportontheLCMReceiverandslowlyopentheneedlevalve.Closethevalveassoonasyouhavecollectedthefiltrate.

Collectfiltrate15secondsafterinitiatingfiltrationtoensurethereisfiltra-tioncontrol.

Continuecollectingfiltratethroughoutthetest.Ataminimum,filtrateshouldbecollectedat15seconds,7.5minutes,and30minutes.

Ifthebackpressurerisesduringthetest,collectsomefiltrateandleavethevalveopenlongenoughtoreducethepressure.

EndingaTest

After30minutes,closetheoutletportonthereceiverandturnofftheheatingjacket.

Allowthecelltocooltoroomtemperaturebeforedisassemblingit.

Afterthecellhascooled,slowlyopenthepressurereleasevalveonthepump.Thiswillallowhydraulicoiltoflowbackintothepump.

Opentheoutletportonthereceivertocollectanyremainingfiltrate.

ClosetheregulatorontheCOpressureassemblyandreleaseanyre-mainingpressurebyopeningthesafetybleedervalve.2

RemovetheCOpressureassemblyfromtheLCMReceiver.

2

UnscrewtheLCMReceiverbodyfromthebottomreceivercap.

Disconnecttheinletpressuremanifoldfromtheinletpressureassembly(quickconnectfitting).

Asmallamountofhydraulicoilmaybereleased.

Removethecellfromtheheatingjacketandplaceitonastandfordisas-sembly.

Reconnecttheinletpressuremanifoldtotheinletpressureassembly(quickconnectfitting)

Unscrewandremovetheoutletcellcapassembly.

Removetheceramicdiskorfilterpaperandsaveitforanalysis.Discardanyremainingtestfluid.

Iftheceramicdiskdoesnoteasilycomeoutofthecell:

Closethepressurereliefvalveonthepump.

Strokethepumpuntilthepressurepushestheceramicdiskoutofthecell.

Thenre-openthepressurereliefvalveonthepump.

ScrewtheT-handleintothepistonontheoutletside.

Manuallypushthepistontothebottomofthecell.Thiswillforceanyre-maininghydraulicfluidbackintothepump.

Closethepressurereleasevalveonthepumpandtheballvalveonthepressuremanifold.

Disconnectthepressuremanifoldfromtheinletpressureassembly.

Removetheinletpressureassembly,cellcapassembly,andpiston.Beawarethatsomehydraulicfluidwillremaininthecell.

CleananddrytheentirecellandLCMReceiverassemblies.Paycloseat-tentiontothethreads.Alsomakesuretocleantheoutletvalveassembly.Inspectallo-ringsandreplaceanythatshowsignsofdamageorwear.

DataFiltrateVolume2

TheHTHPfilterpresshasafiltrationareaof3.55in2(22.9cm).Thisishalftheareaofastandardfiltrationtest,whichis7.1in2(45.8cm2).Tocomparetheresultsofthistesttoastandardfiltrationtest,doublethetotalfiltratevol-umecollected.

V=2(V)

F30Where:

V=StandardFiltrateVolume(mL)

VF=Filtratevolumecollectedafter7.5minutes

7.5

SpurtLoss(Optional):

SpurtLossistheamountoffiltratecollectedbeforethefiltercakehashadachancetoformandisexpressedinmillimeters.Tocalculatethespurtloss,usethefollowingequation:

V=2[V-(V-V)]=2(2V-V)=4V-2V

17.5307.57.5307.530Where:

V=SpurtLoss

1

V=Filtratevolumecollectedafter7.5minutes

7.5

V=Filtratevolumecollectedafter30minutes

30

FilterCake

Washthefiltercakeonthepaperwithagentlestreamofwater.Measureandreportthethicknessofthefiltercaketothenearest1/32in(0.8mm).Arulerwiththe“zeromark”attheveryedgeoftherulerisusefulhere.Cakedescrip-tionsmaybesubjectiveandsuchnotationssuchashard,soft,rubbery,andfine,etc.conveyadequateinformationoncakequality.

CellCap1.Placethelockingring(#171-190-023)aroundthecap.Assembly2.Placetheretainingring(#130-81-040)intothegroovearoundtheoutside

ofthecap.Makesureitengagescompletelyaroundthecircle.

Thecapshouldturnfreelyinsidethelockingring.

Cap

RetainingRing

LockingRing

O-ring

Piston1.Placearupturedisko-ring(#120-910-028)intotherupturediskport.Assembly2.Screwtherupturediskintotheport.

Placeano-ring(#700-100-096)intothebleedport.

Screwthesetscrew(#171-190-039)intothebleedport.Unscrewitonefullturn.

Placetwoo-rings(#171-900-025)intheo-ringgroovesaroundtheout-sideofthepiston.

RuptureDiskSetScrewO-ring

O-ring

Maintenance1.Thoroughlycleananddryallcomponentswithwaterandsoap(orappro-

priatesolvent).

Periodicallycheckthecellassemblyforleaks.Pressurizethecellandim-merseitinwater.Lookforbubbles.

Iftheregulatorlosespressureorsteadilyincreasespressure,replacetheseatassemblyanddiaphragm.UsetheRegulatorRepairKit(#143-07).Alwaysreplacetherubberdiaphragm(#143-00-1,soldseparately).Toreplacetheseatassembly:

Unscrewthespringcase(housingcover).Thismayrequireastrapwrench.

Removethespringcase.

Removetherubberdiaphragmfrominsidethespringcase.

Removethethrustplate.

Usingawrench,loosenandremovethebrassretainer.

Thethrustpinandseatarenowexposed.Removethemfromthebase.

Replacethespring.

Replacetheseatholder.

ReplacethethrustpinandtheTeflonseat,whichcanbeattachedbeforeinsertion.

Replacethebrassretainerwithawrench.

Replacethethrustplatewiththecurvededgesdownward.

Placeanewrubberdiaphragminsidethespringcase.

Replacethespringcaseandhandtighten.

DiaphragmRepairKit(#143-00-1)(#143-00-1)

PowerCord

Checkthepowercordforinsulationwearandlooseconnectionsneartheheatingjacketandplug.

Placetheheatingjacketnofartherfromtheheatingjacketthanthelengthofthepowercord.

Keepthepowercordawayfromthehotsurfaceoftheheatingjacket.

Installingwiring,powercords,orelectricalconnectorswillvoidthewarranty.

RegulatorMaintenanceandTroubleshooting

Symptoms

Cause:Resolution

Gasleakattheregulatoroutletwhentheadjustingscrewisloosenedfullycounterclockwise

Seatleakor*creep:Repairtheregulator

Outletpressureincreaseswhiledownstreamvalvesareclosed

Seatleakor*creep:Repairtheregulator

Gasleakfromthespringhousingcase

Diaphragmfailure:Repairtheregulator

Excessdropinoutletpressurewiththeregulatorflowopen

Blockedseatassemblyorinletfilter:Repairtheregulator

Gasleakfromanypipethreadjoint

Loosefitting:Removetheconnection.Cleantheaffectedsurfaces.ReapplyTeflontapeandtighten.

Gasleakfromreliefvalve

Faultyreliefvalve:replacethevalve.Seatleakor*creep:Repairtheregulator

Inconsistentrepeatreadings

Seatsticking:Repairtheregulator.Badpressuregauge:Replacethegauge.

Gaugedoesnotreturntozerowithnopressureappliedtotheregulator.

Gaugehasphysicaldamage:Replacethegauge.

*Creepisanincreaseinoutletpressurethatoccurswhenpressureescapesevenwhenthevalveisclosed.Regulatorseatscanbecompromisedbyparticlesintheprocessstreamwhichcancauseminorimperfectionsinthesealingsurface.Thehighflowandsmallorificecreatedduringpressureregulationcombinetoturnaverysmallparticleintoafastprojectile.Thisprojectilecannickthesealingsurfaceoftheseatandcauseleaks.Filteringparticulatesfromtheprocessstreamshouldbeahighpriority,andasmallfiltercanreducethepotentialforcreepandincreasethelifeexpectancyandaccuracyoftheregulator.

OFITE,11302SteeplecrestDr.,Houston,TX77065USA/Tel:832-320-7300/Fax:713-880-9886/

PAGE

23

DiagramsPermeabilityPlugging

Tester

Gauge,1500PSI

(#171-34)

Regulator(#170-08)Barrel(#143-03)

ManifoldBlock

(#170-20)SafetyPinwithLanyard

(#171-23-1)

NeedleValveValveStem(#170-16)

(#170-32)

TopCap(#171-84-012)O-ring(#171-84-015)

Body(#171-84-010)

NeedleValve

(#170-32)

Filter(#171-84-014)BottomCapO-ring(#171-84-015)

(#171-84-011)

VCOFitting,Female(#500-350-003)

VCOFitting,Male(#500-350-004)

TestCell(#171-193-6K-S)

TestFluid

O-ring,Viton

Piston(75D:#171-99)(#171-190-024-S)(90D:#171-190-061)

HydraulicOil(#171-96-1)

Qui

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论