BSEN50134-5:2021

BSIStandardsPublication

Alarmsystems—Socialalarmsystems

Part5:Interconnectionsandcommunications

bsi.

BSEN50134-5:2021BRITISHSTANDARD

Nationalforeword

ThisBritishStandardistheUKimplementationofEN50134-5:2021.

ItsupersedesBSEN50134-5:2004,whichwillbewithdrawnon

2February2022.

TheUKparticipationinitspreparationwasentrustedtoTechnicalCommitteeGW/1,Electronicsecuritysystemsandproducts.

Alistoforganizationsrepresentedonthiscommitteecanbeobtainedonrequesttoitscommitteemanager.

Contractualandlegalconsiderations

Thispublicationhasbeenpreparedingoodfaith,howeverno

representation,warranty,assuranceorundertaking(expressor

implied)isorwillbemade,andnoresponsibilityorliabilityisorwillbeacceptedbyBSIinrelationtotheadequacy,accuracy,completenessor

reasonablenessofthispublication.Allandanysuchresponsibilityandliabilityisexpresslydisclaimedtothefullextentpermittedbythelaw.

Thispublicationisprovidedasis,andistobeusedatthe

recipient'sownrisk.

Therecipientisadvisedtoconsiderseekingprofessionalguidancewithrespecttoitsuseofthispublication.

Thispublicationisnotintendedtoconstituteacontract.Usersareresponsibleforitscorrectapplication.

◎TheBritishStandardsInstitution2021

PublishedbyBSIStandardsLimited2021

ISBN9780539041842

ICS13.320

CompliancewithaBritishStandardcannotconferimmunityfromlegalobligations.

ThisBritishStandardwaspublishedundertheauthorityofthe

StandardsPolicyandStrategyCommitteeon31July2021.

Amendments/corrigendaissuedsincepublication

DateTextaffected

BSEN50134-5:2021

EUROPEANSTANDARDNORMEEUROPEENNEEUROPÄISCHENORM

EN50134-5

July2021

ICS13.320SupersedesEN50134-5:2004andallofitsamendments

andcorrigenda(ifany)

EnglishVersion

Alarmsystems-Socialalarmsystems-Part5:Interconnectionsandcommunications

Systèmesd'alarme-Systèmesd'alarmesociale-Patie5:

Communicationetinterconnexion

Alarmanlagen-Personen-Hilferufanlagen-Teil5:VerbindungenundKommunikation

ThisEuropeanStandardwasapprovedbyCENELECon2021-06-07.CENELECmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivingthisEuropeanStandardthestatusofanationalstandardwithoutanyalteration.Up-to-datelistsandbibliographicalreferencesconcerningsuchnationalstandardsmaybeobtainedonapplicationtotheCEN-CENELECManagementCentreortoanyCENELECmember.

ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversioninanyotherlanguagemadebytranslation

undertheresponsibilityofaCENELECmemberintoitsownlanguageandnotifiedtotheCEN-CENELECManagementCentrehasthe

samestatusastheofficialversions.

CENELECmembersarethenationalelectrotechnicalcommitteesofAustria,Belgium,Bulgaria,Croatia,Cyprus,theCzechRepublic,

Denmark,Estonia,Finland,France,Germany,Greece,Hungary,lceland,Ireland,taly,Latvia,Lithuania,Luxembourg,Malta,the

Netherlands,Norway,Poland,Portugal,RepublicofNorthMacedonia,Romania,Serbia,Slovakia,Slovenia,Spain,Sweden,Switzerland,TurkeyandtheUnitedKingdom.

EuropeanCommitteeforElectrotechnicalStandardization

ComitéEuropéendeNormalisationElectrotechniqueEuropäischesKomiteefürElektrotechnischeNormung

CEN-CENELECManagementCentre:RuedelaScience23,B-1040Brussels

◎2021CENELECAllrightsofexploitationinanyformandbyanymeansreservedworldwideforCENELECMembers.

Ref.No.EN50134-5:2021E

2

BSEN50134-5:2021

EN50134-5:2021(E)

ContentsPage

Europeanforeword 4

Introduction 6

1Scope 7

2Normativereferences 7

3Terms,definitionsandabbreviations 8

3.1Termsanddefinitions 8

3.2Abbreviations 10

4Interconnections 10

4.1Generalrequirements 10

4.2Wireless 11

4.3Availability 11

4.4Monitoring 11

4.5Security 11

4.6Transmissiontime 12

4.7Videoandotherapplications 12

4.8Two-wayspeechcommunication 12

5Communications 12

5.1Commentary 12

5.2Generalrequirements 12

5.3Alarmtransmissionequipment 13

5.3.1General 13

5.3.2Transmissionlinkssharedwithotherapplications 14

5.3.3MonitoringoftheinterconnectionwiththeAE 15

5.4Technicalperformancerequirementsofthealarmtransmissionsystem 15

5.4.1General 15

5.4.2Sessional-connectedorswitchedpaths 15

5.4.3Packetswitchednetworks 16

5.5Thecontroller 17

5.5.1Environmentalrequirements 17

5.5.2Accesslevels 17

5.5.3Sessional-connectedorswitchedpaths 17

5.5.4Permanentvirtualpacketswitchedpaths 17

5.5.5Voicecommunicators 17

6DigitaltoAnalogueconversionwithinthealarmtransmissionpath 18

6.1Commentary 18

6.2General 18

6.2.1General 18

6.2.2Transmissionnetworkequipment 18

6.2.3Digitaltoanalogueconversionunits 19

3

BSEN50134-5:2021

EN50134-5:2021(E)

7Logicalalarmtriggering 19

7.1Commentary 19

7.2General 19

7.3LogicalalarmtriggeringfromastandalonelocaldeviceconnectedtotheLocalUnit

orController 19

7.3.1General 19

7.3.2LogicalalarmtriggeringgeneratedwithintheLocalUnitorController 20

7.3.3LogicalalarmtriggeringfromaDeviceProvisioningandManagement

Platform 20

7.3.4LogicalalarmtriggeringfromwithintheAlarmManagementSystem 21

8Generalsecurityrequirements 21

8.1General 21

8.2Designconsiderations 22

8.3ATS 22

8.4Useofstandardcryptographicalgorithmsandsecurityprotocols 22

8.5Authenticationrequirements 22

8.6Tests 23

8.6.1General 23

8.6.2ATSNPerformance 23

8.6.3TransmissionTime 23

8.6.4VerificationInterval 23

8.6.5Availability 23

8.6.6Calculationofavailability 23

8.7Documentation 23

8.8Verificationofperformanceoftheinterconnections 23

Bibliography 24

4

BSEN50134-5:2021

EN50134-5:2021(E)

Europeanforeword

Thisdocument(EN50134-5:2021)hasbeenpreparedbyCLC/TC79,"Alarmsystems".

Thefollowingdatesarefixed:

·latestdatebywhichthisdocumenthastobe(dop)2022-06-07

implementedatnationallevelbypublicationof

anidenticalnationalstandardorby

endorsement

·latestdatebywhichthenationalstandards(dow)2024-06-07

conflictingwiththisdocumenthavetobe

withdrawn

ThisdocumentsupersedesEN50134-5:2004andallofitsamendmentsandcorrigenda(ifany).

EN50134-5:2021includesthefollowingsignificanttechnicalchangeswithrespecttoEN50134-5:2004:

-Theminimumperformanceparametersfortheinterconnectionincludingavailability,monitoring,security,transmissiontimearenowdeterminedbyupdatedreferencetoEN50136-1:20121.

-Requirementsformicrophoneandspeakerperformancetodelivertwo-wayspeechhavebeenremovedandarenowdeterminedwithEN50134-3:2012.

-Requirementsforthealarmtransmissionsystemhavebeenupdatedtotakeaccountofthegeneralmigrationofvoicetraffictopacket-basedIPinfrastructuresbytelecommunicationsproviders.

-TheminimumtechnicalperformancerequirementsofthealarmtransmissionsystemarenowprescribedbyupdatedreferencetoEN50136-1:20121.

-TherequirementsforanATSusedwithinsocialalarmsystemsaresetoutascustomcategoriesutiizingperformancemetricsdrawnfrommorethanonestandardizedATSconfigurationclassdescribedwithEN50136-1:20121

-Performanceparametersarenowprescribedforbothsessionalconnected,switchedpathsorpackedswitchednetworks.

-Differenttechnicalperformancerequirementsforthealarmtransmissionsystemnowincludedforacontrollerdesignedforusewithonelocalunitormultiplelocalunits.

-Requirementshavebeenaddedwheredigitaltoanalogueoranaloguetodigitalsignalconversionisutilized.

-Requirementshavebeenaddedwhereadigitaltoanalogueconversionunitundertakestranslationbetweenananaloguesignallingprotocolandadigitalsignallingprotocol.

-Accounthasbeentakenoftheincreasinguseoflogicalalarmtriggeringwheredatafromseveralsourcesarecombinedtodeterminewhetheraspecifiedalarmtriggeringconditionhasbeenmet.Minimumrequirementsarenowincludedlogicalalarmtriggeringfromanyofthefollowing:triggerdevice,localunitandcontroller,deviceprovisioningandmanagementplatformandthealarmmanagementsystem.

-Securityrequirementsincludingdesignconsiderations,useofcryptographicalgorithmsandsecurityprotocolsnowincludedtoprotectcomponentsofasocialalarmsystemfrommaliciousattacks,inadvertentinfluencesandtoensureprivacyandintegrityofthetransmittedinformation.

5

BSEN50134-5:2021

EN50134-5:2021(E)

Attentionisdrawntothepossibilitythatsomeoftheelementsofthisdocumentmaybethesubjectofpatentrights.CENELECshallnotbeheldresponsibleforidentifyinganyorallsuchpatentrights.

Anyfeedbackandquestionsonthisdocumentshouldbedirectedtotheusers'nationalcommittee.AcompletelistingofthesebodiescanbefoundontheCENELECwebsite.

BSEN50134-5:2021

6

EN50134-5:2021(E)

Introduction

Asocialalarmsystemprovides24hfacilitiesforalarmtriggering,identification,signaltransmission,alarmreception,loggingand2-wayspeechcommunication,toprovidereassuranceandassistanceforpeopleconsideredtobeatrisk.

Thesocialalarmsystemprovidesstreamingmediabetweenthelocalunit,thecontrollerandthealarmreceivingcentre.Asaminimumitisintheformofvoicecommunicationbutinadditionitmayinclude,statusdata,videoandvoiceorothercontinuousstreamingdata.Alarm,fault,andstatusmessagesmaybereceivedandprocessedatasingle,multipleordifferentARC's.

Thesocialalarmsystemcanincludeoneormanytriggerdevicesconnectedtothelocalunitand/orcontrollerviainterconnections,thesecurityandintegrityofwhichareessentialtoproperoperationofthealarmsystem.AscommunicationsproviderscontinuetomigratetowardsNextGenerationNetworkstheyareincreasinglyconvergingvoicetrafficontotheirpacketbasedIPinfrastructures,whichmightnolongerhavearegulatoryrequirementtosupportin-callDTMFtones.Thiscouldhaveanadverseimpactonthereliabilityofin-calltone-basedprotocolsusedinsocialalarmsystems,whichcoulddrivefuturesystemsdevelopmenttotheuseofcommunicationprotocolsengineeredforpacketbasedtransmissionenvironments.

Socialalarmsystemsarepartofafamilyofalarmsystemssharingcommonstandardsforaspectssuchastheperformancecharacteristicsofthealarmtransmissionsystem.ThesecommonperformancemetricsaredefinedwithintheEN50136seriesandthisdocumentselectstheappropriateperformanceparametersforsocialalarmsystemsbyreferencetotheEN50136series.

BSEN50134-5:2021

7

EN50134-5:2021(E)

1Scope

Thisdocumentspecifiestheminimumrequirementsfortheperformance,reliabilityandsecuritycharacteristicsofinterconnections,alarmtransmissionsystemsandcommunicationswithinasocialalarmsystem.

2Normativereferences

Thefollowingdocumentsarereferredtointhetextinsuchawaythatsomeoralloftheircontentconstitutesrequirementsofthisdocument.Fordatedreferences,onlytheeditioncitedapplies.Forundatedreferences,thelatesteditionofthereferenceddocument(includinganyamendments)applies.

EN50134series,Alarmsystems-Socialalarmsystems

EN50134-2:2017,Alarmsystems-Socialalarmsystems-Part2:Triggerdevices

EN50134-3:2012,Alarmsystems-Socialalarmsystems-Part3:Localunitandcontroller

CLC/TS50134-9,Alarmsystems-Socialalarmsystems-Part9:IPCommunicationsProtocol

EN50136-1:20121,Alarmsystems-Alarmtransmissionsystemsandequipment-Part1:Generalrequirementsforalarmtransmissionsystems

EN50136-2:2013,Alarmsystems-Alarmtransmissionsystemsandequipment-Part2:RequirementsforSupervisedPremisesTransceiver(SPT)

EN50136-2-4:1998,Alarmsystems.Alarmtransmissionsystemsandequipment.Requirementsforequipmentusedinsystemswithvoicecommunicatorsusingthepublicswitchedtelephonenetwork

EN50136-3,Alarmsystems-Alarmtransmissionsystemsandequipment-Part3:RequirementsforReceivingCentreTransceiver(RCT)

EN50518:2019,MonitoringandAlarmReceivingCentre

EN50600series,Informationtechnology-Datacentrefacilitiesandinfrastructures

ETSIEN300220-2,ShortRangeDevices(SRD)operatinginthefrequencyrange25MHzto1000MHz;Part2:HarmonisedStandardforaccesstoradiospectrumfornonspecificradioequipment

ETSIEN300328,Widebandtransmissionsystems;Datatransmissionequipmentoperatinginthe2,4GHzband;HarmonisedStandardforaccesstoradiospectrum

ETSIEN300440,ShortRangeDevices(SRD);Radioequipmenttobeusedinthe1GHzto40GHzfrequencyrange;HarmonisedStandardcoveringtheessentialrequirementsofarticle3.2ofDirective2014/53/EU

ETSIEN301406,DigitalEnhancedCordlessTelecommunications(DECT);HarmonisedStandardcoveringtheessentialrequirementsofarticle3.2oftheDirective2014/53/EU

ETSIEN302065-1,ShortRangeDevices(SRD)usingUltraWideBandtechnology(UWB);HarmonisedStandardcoveringtheessentialrequirementsofarticle3.2oftheDirective2014/53/EU;Part1:RequirementsforGenericUWBapplications

1AsimpactedbyEN50136-1:2012/A1:2018.

8

BSEN50134-5:2021

EN50134-5:2021(E)

ETSIEN303406,ShortRangeDevices(SRD);SocialAlarmsEquipmentoperatinginthefrequencyrange25MHzto1000MHz;HarmonisedStandardcoveringtheessentialrequirementsofarticle3.2ofDirective2014/53/EU

ETSIEN303645,CYBER;CyberSecurityforConsumerInternetofThings:BaselineRequirements

3Terms,definitionsandabbreviations

3.1Termsanddefinitions

Forthepurposesofthisdocument,thefollowingtermsanddefinitionsapply.

ISOandIECmaintainterminologicaldatabasesforuseinstandardizationatthefollowingaddresses:

—ISOOnlinebrowsingplatform:availableat

/obp

—IECElectropedia:availableat

/

3.1.1

socialalarmsystem

systemproviding24hourfacilitiesforalarmtriggering,identification,signaltransmission,alarmreception,2-wayspeechcommunication,reassuranceandassistance,forusebypersonsconsideredtobeatrisk

3.1.2

alarmreceivingcentre

ARC

systempartwhichprovidesfacilitiesforcommunicationwithanumberofcontrollers,andprovidingthealarmreceivingandinformationprocessingsystemasaninterfacetothealarmrecipient

3.1.3

alarmtransmissionservicenetwork

ATSN

groupofATSsofthesamecategory

Note1toentry:AnATSNconsistsofoneormoreATSsofthesamecategory,functioningundersupervisionofthe

samemanagementandmonitoringcentre.

3.1.4

communications

transmissionofdatabetweenthetriggerdevice,localunitandcontrollerandtheARCoranalarmrecipient

3.1.5

controller

interfacebetweenoneormorelocalunitsandthealarmtransmissionsystemoralarmrecipient,thecontrollernormallyincludestheSPTasdefinedinEN50136-2

3.1.6

localunit

interfacebetweentheuserandthecontrollerwhichenables2-wayspeech

3.1.7

triggerdevice

systempart,operatedbyahumanorautomaticallythatcommunicatestothelocalunitandcontroller,initiatingthealarmtriggeringsignal

9

BSEN50134-5:2021

EN50134-5:2021(E)

3.1.8

logicalalarmtriggering

combinationofthepresenceorabsenceofdatafromoneormoresystempartswhichmeetsapredefinedconditionforthegenerationofanalarmtriggeringsignal

Note1toentry:Logicaltriggeringcanbeimplementedinanypartofthesocialalarmsystem.

3.1.9

deviceprovisioningandmanagementplatform

systemforthetechnicaladministrationoftheequipmentestateandmaybecapableofgeneratingalarms

3.1.10

interconnections

transmissionsystemthatprovidesthecommunicationbetweentriggerdevicesandlocalunitandcontroller

3.1.11

alarmtransmissionsystem

ATS

alarmtransmissionequipmentandnetworksusedtotransferinformationconcernedwiththestateofoneor

morelocalunitsandcontrollerstotheannunciationequipmentatoneormoreARCsoranalarmrecipientNote1toentry:AnATSmayconsistofmorethanoneATP.

3.1.12

alarmtransmissionpath

ATP

routeandalarmmessagetravelsbetweenanindividualalarmsystemanditsassociatedannunciationequipment

Note¹toentry:TheATPstartsattheinterfacebetweentheASandSTPandendsattheinterfacebetweentheRCTandAE.Fornotificationandsurveillancepurposes,thereversedirectionmayalsobeused.

3.1.13

pre-alarmcondition

conditionfollowingthereceptionofanalarmtriggeringsignal

3.1.14

alarmcondition

conditionfollowingthepre-alarmcondition

3.1.15

faultcondition

conditionfollowingdetectionofafaultbythelocalunitandcontroller,thatpreventsthefunctioningofthesystem

3.1.16

pre-alarmwarningindication

indicationatthelocalunitthatthelocalunitisinthepre-alarmcondition

3.1.17

faultindication

indicationofafaultcondition

3.1.18

reassuranceindication

indicationprovidedlocallyinalarmconditioninordertoverifytotheuserthatthelocalunithasreceivedthealarmtriggeringsignal

10

BSEN50134-5:2021

EN50134-5:2021(E)

3.1.19

alarmtriggeringsignal

signaltransmittedbyatriggerdevicetoindicateanalarm

3.1.20

alarmrecipient

personwhoreceivesandactsuponanalarmsignal

3.1.21

faultreportingtime

maximumintervalfromthetimeafaultoccursintheinterconnectionuntilthetransmissionofafaultsignalisinitiatedbythecontroller

3.2Abbreviations

Forthepurposesofthisdocument,thefollowingabbreviationsapply.

DTMFDualtonemulti-frequency;

PSTNPublicswitchedtelephonenetwork;

EMCElectromagneticcompatibility;

ETSIEuropeanTelecommunicationsStandardsInstitute;DPMPDeviceprovisioningandmanagementplatform

RFRadiofrequency

ASAlarmsystem

AEAnnunciationequipment

NOTEthetermusedintheEN50136seriesforAMSAMSAlarmManagementSystem

NOTEthetermusedintheEN50518seriesforAERCTReceivingcentretransceiver

SPTSupervisedpremisestransceiver

ATEAlarmTransmissionEquipment

ATAAnalogueTerminalAdapter

4Interconnections

4.1Generalrequirements

Theinterconnectionsshallbedesignedtoprovideareliablemeansofcommunicationbetweentriggeringdevices,thelocalunit(s)andthecontroller.Theinterconnectionmaybewiredand/orwireless.

Theinterconnectionsshallberegardedasanelementinaseriesofconnectedalarmtransmissionpathstowardsthealarmreceivingcentre.

11

BSEN50134-5:2021

EN50134-5:2021(E)

Theminimumperformancerequirementsforalarmtransmissionshallbeasstatedin4.3.Wheretheinterconnectionsareusedforthetransmissionofadditionalservicese.gvideo,habitmonitoringdata,actimetry,theperformanceavailabletoalarmtransmissionshallnotbediminished.

4.2Wireless

ForwirelessinterconnectionsviaRF,frequenciesdesignatedforlowdutycyclehighreliabilityequipment/socialalarmsystems)shallbeusedforthetransmissionofalarmandfaultsignals.

IftheRFinterconnectionisdeliveredusingalternativefrequencies,mitigationtechniquesforensuringreliablecommunicationasdescribedinTable1shallbeapplied.

Table1-TechniquesforReliableRFinterconnections

Type

Harmonizedstandard

Prerequisite

SRD

ETSIEN303406

Politespectrumaccess,adaptivefrequencyagilityandacknowledgement.

ETSIEN300220-2

ETSIEN300440

DECT

ETSIEN301406

Acknowledgement

UWB

ETSIEN302065-1

Acknowledgementandmitigationtechniques

2,4GHzWB

ETSIEN300328

Adaptiveequipmentusingadaptivemodewithacknowledgement

NOTE

MitigationtechniquesinUWBinclude"DetectandAvoid"and"LowDutyCycle".

IfothertypesofRFcommunicationareused,similarmitigationtechniquesforpolitespectrumaccessandacknowledgementshouldbeapplied.

4.3Availability

TheinterconnectionsinasocialalarmsystemshallhaveanavailabilitythatfulfilstherequirementsetoutinEN50136-1:20121,Table6,classSP6.

Thenecessaryavailabilityiscalculatedusingthemethodologyin8.6.6withinthisdocument.

4.4Monitoring

Forwiredandwirelesstriggerdevicestheinterconnectionsshallbemonitoredforavailability.

ForinterconnectionsthemaximumpermittedintervalbetweenperiodiccommunicationssignalsormessagesshallbeaccordingtoEN50136-1:20121,Table3,SP2.

ForinterconnectionsbetweenwiredtriggerdevicesandtheLocalUnitandcontrollerthemaximumreportingtimeshallbeaccordingtoEN50136-1:20121,Table3,SP5.

PortabletriggerdevicesmayberemovedfromthedesignatedoperatingareaasidentifiedinEN50134-7:2017,Clause8e)and,inthiscase,willbereportedasafaultsignalorstatusmessage.

ForinterconnectionsbetweenmultiplelocalunitsandacontrollerthemaximumpermittedintervalbetweenperiodiccommunicationsignalsormessagesshallbeaccordingtoEN50136-1:20121,Table3,SP6.

4.5Security

Inalarmsystemsthereisariskofmalicioussubstitutionofradiosignalstogeneratefalsealarmorfaultsignals.Whilstinotherapplicationsofalarmsystemsmalicioussubstitutioncouldposeasignificantrisktosystemintegrity,inthecaseofsocialalarmsthisriskisviewedasminimalandthisdocumentmakesnorequirementsforpreventativetechniques.

BSEN50134-5:2021

12

EN50134-5:2021(E)

4.6Transmissiontime

FortheinterconnectionbetweenatriggerdeviceandlocalunitthemaximumalarmandfaultsignaltransmissiontimeshallbeaccordingtoEN50136-1:20121,Table2,SP3.

ForinterconnectionsbetweenmultiplelocalunitsandacontrollerthemaximumalarmandfaultsignaltransmissiontimeshallbeaccordingtoEN50136-1:20121,Table2,SP6.

4.7Videoandotherapplications

Whereotherservicesutilizetheinterconnection,e.g.videobetweendwellings,videotoARC,voicetelephony,doorentry,internetprovisionthisusageshouldnotimpactordegradetheperformanceoftheinterconnectionforsocialalarmapplicationsasdescribedinthisdocument.

4.8Two-wayspeechcommunication

Theinterconnectionshouldhavesufficientcapacitytodeliverthebandwidthrequirementsforthenumberofratedsessionswithoutdegradationfromtheperformancerequirementssetoutin4.6.CapacitymanagementWheremultipletriggerdevicesareconnectedtoalocalunitandcontrollerthisshallnotimpactordegradetheperformanceoftheinterconnection(availability,transmissionandreportingtime)

5Communications

5.1Commentary

AnATSorATPmayincludepermanentdedicatedlinks,permanentvirtuallinksorswitchedlinkswhichmayuseequipmentthatisnotcoveredbytherequirementsofEN50136-2,EN50136-3andthisdocumentormaybeaffectedbyotherapplicationssharingthetransmissionlinks.

AnATPmayinclude:

a)atransmissionlinkthatissharedwithnon-alarmdataapplicationse.g.videoorcorporateLANtraffic,streamingentertainment

b)atransmissionlinkthatcarriesotherATPs,

c)equipmentfromathird-partytransmissionnetworkprovider,whichisnotlocatedateithertheuser'spremisesorthealarmreceivingcentreandisnotclassifiedasATE,

d)equipmentfromathirdpartywhichislocatedattheuser'spremisesbutisnotclassifiedasATE.Theperformance(reliability)ofanATScouldbeaffectedby:

e)unwanted,malformedorotherwisemaliciousincomingdataattheinterfacesoftheSPTorRCT,f)transmissionnetworkcongestionasaresultoftransmissionlinksharing,

g)transmissionnetworkunavailabilityduetoequipmentfailureand/ormaintenance.

NOTEAlarmtransmissionequipmentincludestheterminatione.g.ATAtothealarmtransmissionpath.

5.2Generalrequirements

ThealarmtransmissionsysteminasocialalarmsystemshallmeettherequirementswithinEN50136-1:20121.

Thealarmtransmissionsystemshallsupport,asaminimum,thefollowingcommunications:two-wayaudio,alarmandfaultsignals,andstatusmessages.

13

BSEN50134-5:2021

EN50134-5:2021(E)

TheendtoendtransmissionofaudioshallbeinaccordancewiththeperformancecriteriainEN50134-3:2012,4.2.4andshallsupportcodecG.711(a-law)asaminimumorprovideequivalentperformance.

Forcombinedlocalunitandcontrollersthepointtopointtransmissionofalarms,faults,controlsignalsandcommunicationsmonitoringbetweenthelocalunitandcontrollerandtheARCshalluseapacketbasedcommunicationprotocol.TheIPprotocolspecifiedinCLCTS50134-9shallbeusedwherethealarmtransmissionsystemimplementsaTCP/UDPprotocolcommunicationstack.Whereasocialalarmsystemisbeingusedtotransmitsi

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论