瓦里安系列15-瓦里安Vista扫描光谱仪.ppt_第1页
瓦里安系列15-瓦里安Vista扫描光谱仪.ppt_第2页
瓦里安系列15-瓦里安Vista扫描光谱仪.ppt_第3页
瓦里安系列15-瓦里安Vista扫描光谱仪.ppt_第4页
瓦里安系列15-瓦里安Vista扫描光谱仪.ppt_第5页
已阅读5页,还剩115页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

1、美国瓦里安公司 Varian Inc.,瓦里安公司新一代ICP介绍,Vista - the new CCD Simultaneous ICP from Varian,Varian 的ICP “家族”Liberty 和 Vista,Liberty Series II - 世界上最好的单道扫描式 ICP-AES,Vista - 世界上速度最快的全谱直读式ICP-AES,What is a Plasma?,A plasma is a stream of highly ionized gas containing an equal number of electrons and positive io

2、ns A plasma is electrically conductive A plasma is affected by a magnetic field,Quantitation in Atomic Emission,Concentration proportional to intensity emitted at the analyte wavelength.,Concentration,Emission,0,1,Standard,Blank,sample emission,sample concentration,Axial Channel ZonesVisual Determin

3、ation,Yttrium Test Aspirate 1000 mg/L Y solution,Blue Ionic,Red Atomic,ICP 技术特点,背景低 对70 多个元素有较低的检出限 为多元素分析技术 极高的分析效率 很宽的线性范围 可分析溶液中的主量, 微量 和痕量元素 干扰少 主要为光谱干扰 操作简单,ICP 仪器组成,RF 发生器,计算机,打印机,炬管系统,光学系统,检测器,进样泵,发 射 光 谱 的 发 展,全谱直读 固体检测器(CCD) 单道扫描 PMT 多道 PMT 摄谱仪 感光板,ICP-OES Basic Concepts多道光谱仪,ICP-OES Basic

4、Concepts单道扫描光谱仪,多道 ICP 和单道扫描 ICP 的优缺点,多道ICP单道扫描ICP 优点:速度快灵活 效率高易于建立方法 缺点:死板速度慢, 消耗成本高 扣背景不准确精度较差 共同缺点: 背景和信号不能同时测定, 存在时间误差 扣背景速度慢,Echelle optics,88o,19o,ICP-AES市场概况,Varian所占市场份额(现状),ICP-AES市场概况,Varian所占市场份额(预期),Vista CCD 全谱直读 ICP设计理念(一),设计制造尽可能好的最先进的全谱直读式ICP 优异的性能 强大的灵活性 快速、节省消耗成本 易于使用 能够分析广泛的样品 能够扩

5、展到双向观察的动态范围 高技术水平,Vista CCD 全谱直读 ICP设计理念(二),什么是仪器的先进性? 能够集以往仪器的优点于一身, 同时又能克服其各自缺点的仪器. 怎样实现? 采用更新、更先进的技术,Vista CCD 全谱直读 ICP设计理念(三):技术分析,当前市场状况:有两种全谱直读式ICP 分段式CCD,可同时测UV、VIS,但波长不连续,覆盖6谱线,SCD饱和溢出。 CID 作检测器,波长基本连续,但UV、VIS不能同时,CID 分析性能差, 需UV转换膜,寿命问题。 均不能彻底实现全谱直读,速度不够快。 垂直、水平、双向:均不能同时具备两者优点 检测器:PMT,CID,CC

6、D? CCD:分析性能优于光电倍增管。 CID:分析性能不如光电倍增管,需要有机涂膜。,Instrumentation for Optical Emission Spectroscopy,Table 3.11 A. Comparison Between the Minimum Detectable Signals of PDA, ISPDA, CID, PMT, and CCD Minimum detectable signal(S/N=2), photon/S/detector element aquisition PDA ISPDA CID PMT CCD _ time(s) UV VIS

7、 UV VIS UV VIS UV VIS UV VIS 10 671 363 32 53 41 32 6.3 26 3.1 1.7 100 112 62 10 17 4.2 3.3 1.8 7.3 0.3 0.2 Table 3.11B Parameters Used in Caculating the Minimum Detactable Signal Parameter PDA ISPDA CID PMT CCD QE at 600nm73% 6% 37% 5% 84% QE at 300nm40% 10% 19% 21% 50% Dark count rate36000 4000 0.

8、008 3 0.001,Vista Measured Quantum Efficiency,CCD 器件在光学仪器中的应用,孙 长 明 上海光学仪器研究所 摘要近年来CCD应用技术的发展尤为引人注目,CCD器件已显示了突出的功效,在光学仪器领域得到广泛的应用。本文介绍应用CCD器件开发光学仪器所取得的进展。 CCD的特点: 一、灵敏度高,噪声低,灵敏度超过光电倍增管 二、光谱范围宽 三、动态响应范围宽,达10个数量级 四、几何性能很稳定,耐过度曝光,比PMT结实耐用 五、可以多道采样,得到波长强度时间的三维谱图 六、在近几年内,CCD会成为各种光谱仪器的检测器,从而取代光电倍增管。 光学仪器

9、,1993年第一期,Varian的Liberty Series II是全球销售最好的单道扫描式ICP之一(约占市场的40,共1000台) 历经4年的潜心研究,公司本部成立专门的项目组与工厂联合开发 Vista的设计目标:以世界上最好的全谱直读式ICP走入市场 采用了新一代的CCD芯片 主要措施: 以CCD 的速度和性能实现全波长覆盖 以成熟的 Liberty 射频技术和进样技术保证仪器的可靠性,Vista CCD 全谱直读 ICP推出背景,Vista CCD 全谱直读 ICP主要特色,VistaChip CCD以70,000个感光元保证全波长范围覆盖(167nm-785nm),具有强大的灵活性

10、和良好的动态范围 第一台真正意义上的全谱直读式ICP 快速:35 秒检测 73 种元素! 高效的射频系统保证难以测量的样品得以检测 冷锥接口技术将水平、垂直式的优点集于一身 优异的分析性能:检出限、精度、分辨率、稳定性 全面节省成本 易学易用、功能强大的软件系统,Vista 的设计理念(二),仪器性能 实现CID的波长选择灵活性 达到SCD的检出限 分辨率优于0.01nm 实现优于光电倍增管的检测效率,Varian的专利设计 70,000个感光元以连续倾角阵列排列 波长连续测定 图象匹配技术 (I-MAP) 电信号处理速度提高40倍 1 MHz的感光元处理速度 高保真的信号再现性,CCD检测器

11、 VistaChip,改进的检出限和灵敏度,Vista的突出特色之一 VistaChip CCD 检测器,特别定做的、ICP专用的专利CCD检测器 70,000个感光元保证全波长覆盖 各感光元精确地与二维中阶梯光栅图象相匹配 (I-MAP技术) 复式读出电路节省一半的读数时间 电信号处理速度提高40倍 1 MHz的感光元处理速度 半导体冷却保持检测器部分-35oC恒温以降低噪声 电子信号处理在CCD芯片外进行以保证高量子化效率,CCD检测器工作原理(1),70,000个感光元以连续倾角排列 3 级高速寄存器 A - 集光 B - 临时储存 C - 快速读出,CCD检测器工作原理(2),中阶梯光

12、栅多色仪的焦面落在检测器的感光元(A寄存器)上 光敏寄存器A把光信号转化为电信号,每个感光元上都有溢流保护以防信号过载,Vista - Anti-blooming 防止过饱和溢出,0.5 mg/L Pb in 5000 mg/L Al,Vista谱图三维图象,CCD检测器工作原理(3),经一段时间的累积,电子从寄存器A转移到临时寄存器B,A,B,CCD检测器工作原理(4),然后电子又从寄存器B转移到读出寄存器C,并以1MHz的频率顺序读出,35秒检测73种元素,包括25秒的进样时间! 1MHz的感光元读出速度 从芯片两侧读取数据的复式电路,光学系统结构图,CCD检测器,光栅,棱镜,光栅和棱镜的

13、二维分光,19o,Vista 完美的光学系统,集成化、台式的中阶梯光栅光谱仪 35oC恒温保证了光路的稳定性 采用 94.7线/mm的中阶梯光栅的1988级衍射光 CaF2 晶体棱镜做交叉色散 Ar或N2 吹扫提供优异的190nm以下波长的检测 计算机控制的前置光路用于优化等离子体的视场,Vista无与伦比的40MHz射频系统,集成化的内置40MHz自激式射频系统 采用空气冷却且无移动部件保证了系统的高可靠性 DISC - 直接耦合系统 无二级匹配网络 80%的耦合效率 出色的MgII/MgI比率 功率输出稳定性0.1 % 完美的有机溶剂和高盐含量溶液的检测特性,DISC - Direct S

14、erial Coupling System,Direct coupling - 75 to 85 % efficient Conventional RF supply 50 -60 % efficient Auto-tune provides high stability for organics Water cooled power tube improves plasma stability,等离子体的强度,0.8,0.9,1,1.1,1.2,1.3,1.4,1.5,Mg Ratio,0.00,2.00,4.00,6.00,8.00,10.00,12.00,14.00,Ratio,Powe

15、r (kW),Vista的等离子体强度的测试结果,以Mg (II)280.270nm对Mg (I)285.213nm的强度比表征,Mg (II)/Mg(I)10表明是高强度的等离子体,Vista独特的轴向观察技术等离子体的结构示意图,Vista CCD ICP-AES Axial 轴向冷锥接口技术,怎样使水平方式在改善检出限的同时,又得到垂直式的抗基体干扰能力? 独特的冷锥接口专利技术,轴向等离子体冷锥接口的横截面图 显示“低温尾焰”已从光路中完全消除,轴向尾焰消除技术,Varian 特有的冷锥接口技术CCI,横向“ 吹尾 ”,使用剪切气对等离子体低温尾焰进行横向吹扫时, “低温尾焰”干扰不可

16、能被完全排除(图中红色部分),并有噪声,横向“ 吹尾 ” 实物照片,Extraction snout,Cool zone,其他抽气方式,Vista优越的轴向检测,高强度的等离子体可容许高含量的固体溶解 冷锥接口技术克服了剪切气的离子化干扰 无需双向检测系统 全波长选择扩展了动态范围 无需如双向观测系统那样两次对样品进行分析,紫外短波段检测的优化设计,体积极小的中阶梯光栅多色仪 0.7 L/min的常规吹扫 对190nm以下波段采用3.0 L/min的加压吹扫 不用时加压吹扫处于关闭状态 使用氮气或氩气 对178nm只需30分钟的吹扫 对 S (180.652, 181.960, 182.542

17、 nm) 对 P (178.192 nm),ICP的运转费用,与直接用户密切相关的要因! 仪器运转费用主要包括: 气:使用气体的种类、纯度和用量 电:一个不容忽视的因素 水:我国目前严重缺水! 维护:尽量避免光路和电路的污染 维修: 故障分析及时准确 零部件的价格和持续性,Vista大幅度降低了运转费用,预热时间短(30分钟),快速启动 快速分析缩短了分析时间,极大降低了分析成本 冷锥接口的轴向设计避免了大量剪切气的使用 高效的吹扫系统仅须0.7或3.7 L/min的气体流量 高效的射频系统消耗较少的氩气和电能 优良的恒温系统大大缩短了运行时间 无移动部件的射频系统和光学系统降低了维修费用,方

18、便快捷的远程诊断功能,远程诊断 - Modem连接使远端的Varian技术服务部门和应用支持部门能够对仪器实现完全控制 有效地降低了维护/维修费用,并减少了停机时间,Vista 功能强大的高智能化软件,Familiar Spreadsheet concept same look as Plasma 96 Easy to use Windows 95,98 & NT 4 compatible Improved user interface operations cut and paste, copy and paste Inter-element corrections FACT Fitted

19、background correction,Ease of Use,在线谱图库表示-图形,VISTA - QCP,Vista 高智能分析软件,Adaptive Integration automatically sets integration time to intensity FACT Spectral deconvolution Programmable QCP enhanced error actions eg recalibrate & repeat Automax Fast auto-optimization wizard Sequence Wizard Quickly set u

20、p complex sequences,Vista Automax 自动最佳化分析条件,Uses 3 different criteria Signal to Background Ratio (SBR), Intensity, Signal to Root Background ratio (SRBR). Optimize all or sub-set of Improves weak Iteratively optimize for non-compromised conditions Optimizes major instrument parameters RF power, view

21、ing height & nebulizer flow,Why Optimize?,Power = 1.2kW Nebulizer flow = 1.00L/min Viewing height = 10mm,Power = 1.5kW Nebulizer flow = 1.70L/min Viewing height = 5mm,Automax 自动最佳化,Vista - 自動最佳化,Ease of Use .,仪器工作条件自动最佳化,Vista 自动调适积分时间,Instrument measures sample for 0.1 second Sets read time for eac

22、h according to intensity If read time is appropriate continues to measure until replicate read time If too short read time increased If too long integration time decreased and data from first read is not accepted Intensity display is normalised,Vista Adaptive Integration,To set acquisition time only

23、 need to set replicate read time number of replicates If replicate read time = 10 sec Very intense 100 x 0.1 sec strong might read 10 x 1 sec weak read 1 x 10 sec,Vista Adaptive Integration,Advantages of adaptive Integration statistics for weak improved by long integration time For intense large num

24、ber of readings averaged to improve results Unlike Optima, VistaChip is able to handle different integration times for different simultaneously Works in the presence of very intense lines because of blooming protection between pixels,Vista MultiCal Extends Linear Dynamic Range,Extends linear dynamic

25、 range by calibration with lines of different sensitivity - ppb to % Easy to use simply specify valid concentration range for each line Improved productivity c.f. dual view as no need to re-run samples Reduces sample consumption May overlap for concentration ranges for improved confidence,Vista - Mu

26、ltiCal 扩展工作範圍 Ca from 20 ug/L - 4000 mg/L,393.366 nm - 0-2 ug/L 422.673 nm - 0-20ug/L 430.253 nm - 0-4000 ug/L,Vista MultiCal Extended Range,Mg 279.553 valid between 0 - 20 ppm Mg 285.213 valid between 20 - 40 ppm,Vista - Retrospective Editing,Edit Replicate results Weight and volume Calibration par

27、ameters Background correction type Background correction position,Vista强大的软件功能 FACT 谱图解析软件,Fast Automated Curve -fitting Technique 快速自动匹配曲线拟合技术 使用一系列的高斯曲线对分析元素的谱线和干扰元素的谱线进行精确模拟 该模拟可以精确地校正极小(1/10感光元)的波长漂移 干扰校正不影响分析速度,FAST!,FACT 谱图解析软件的设计原理,使用FACT软件的解析结果,Resolved spectra using FACT,Vista - FACT,Cd 214

28、.438 nm interfered by Fe 214.443,实际性能测试,Vista全谱直读式ICP-AES,检出限ICP最基本的性能指标之一,所有检出限数据的测定基于以下条件: 采用轴向观察 测定10秒钟的积分时间内的检出限 测定3噪声 对185nm以下的波段采用3 L/min的氩气对光路系统加压吹扫 没有采用内标法 没有进行背景校正,实际测得的检出限,实际测得的检出限,元素,与其他品牌仪器的检出限对比(ppb),Vista Analytical performance,Vista Measured Resolution,实测的分辨率,元素 波 长 分辨率 (nm) (pm) As 1

29、88.979 7.5 Mo 202.030 7.6 Zn 213.856 8.4 Pb 220.353 8.6 Cr 267.716 10 Cu 327.396 13 Ba 614.172 38,Vista - 分辨率,P 213.618 vs Cu 213.598 nm (0.020 nm difference),4小时的稳定性实验结果,4小时的稳定性优于1,0,5000,10000,15000,20000,25000,30000,0,15,30,45,60,75,90,105,120,135,150,165,180,195,210,225,240,时间 (min),净 光 强,Al 396

30、.152,As 188.979,Ba 493.409,Cd 214.438,Cu 327.396,K 766.49,Mn 257.61,Pb 220.353,Se 196.026,Zn 213.856,Cu 324.754,杂散光水平测试,一项重要的光学质量测试 样品:10,000 ppm Ca溶液 测量As 193.696 nm波长处的信号 该信号与基准线的偏差表明杂散光的水平 Vista的杂散光水平 2 ppm As当量,稳定时间测试,35 minutes,应 用 实 例,Vista 全谱直读式 ICP-AES,水和土壤样品的分析,水中成分的分析Recoveries of NIST SRM

31、 1643 c,ElementMeasuredCertified nmug/Lug/L Ag328.0682.262.21+0.3 As188.97983.582.1+1.2 Ba233.52746.649.6+3.1 Be265.04523.123.1+2.2 Cd226.50212.112.2+1 Co228.61621.523.5+0.8 Cr205.55217.419+0.6 Cu324.75416.222.3+2.8 Mn257.61035.735.1+2.2 Mo202.030100104.3+1 Ni231.60458.060.6+7.3 Pb220.35332.735.3+0.

32、9 Tl190.7906.07.9 V292.40228.131.4+2.8,饮用水中金属元素的分析by Axial Vista,ElementMeasuredCertified* nmug/Lug/L Ag328.0682.222.00 As188.97980.680 Ba233.52749.350 Cd226.5029.310 Co228.61622.125 Cr205.55218.320 Cu324.75419.020 Mn260.56942.740 Ni231.60461.060 Pb220.3533540 Sb206.8339.110 Tl190.7901410 V292.46425

33、30 Zn206.20069.770,VistaChip wavelength selection flexibility choose any no need for dual viewed optics simultaneous analysis of trace and major elements,饮用水中主量金属元素的分析Major Elements by Axial Vista,ElementMeasuredCertified* nmmg/Lmg/L Ca318.12836.535 Mg279.0799.69 K766.4902.12.5 Na589.5926.76,* High

34、Purity Standards Co.,土壤中的主量和痕量元素分析by Axial Vista after 1:10 dilution,ElementMeasuredCertified* nmmg/Lmg/L As188.9796.06.3 Ba233.5276.67.0 Cd214.4380.20.2 Co228.6160.070.1 Cu324.7543.13.0 Ni231.6040.100.15 Sb206.8330.160.1 Zn206.20068.870 Fe260.709348350 Al257.510649650 K766.490221210 Na589.592123100

35、,* High Purity Standards Co.,分析结果Water Samples,GFAAS 1GFAAS 4 ElementFound* CertifiedFoundCertified Al0.062 0.050.620.50 V0.027 0.0250.270.25 Cr0.010 0.010.0990.10 Co0.01 0.010.100.10 Cu0.011 0.010.1020.10 Cd0.0024 0.00250.024 0.025 Se0.050 0.00250.0500.025 *All results mg/L,Analysis of impurities i

36、n acidsby Vista,Impurities in acids are important to semiconductor industry Acids e.g. HCl, HNO3, HF, H2O2, etc Due to the ultra trace level of impurities, acid sample is evaporated to dryness in a quartz beaker Then redissolve the impurities in high purity acids Ultrasonic nebuliser is recommended

37、USN offers generally 10 times improvement in detection limit,Metallurgy 冶金分析,Analysis of Palladium compounds樣品前處理,Use 0.1 - 1 g sample, accurately weighed Dissolve in 5 mL aqua regia Make up to 100 mL Standards and blank prepared in 5% aqua regia,基体中的检测限5 % 王水 vs 5 g/L Pd solution,Element5% Aqua reg

38、ia5g/L Pd solution (ug/L) (ug/L) Al 167.0160.360.43 Au 267.5952.113.56 B 182.5801.282.82 Cu 224.7002.344.97 P 177.4358.0116.0 Pt 265.9458.9412.3 Ru 240.2722.423.56 Sn 189.9263.037.90 Zr 343.8231.54 1.62,Analysis of Palladium compoundsRepeatability Test - 20 samples,Precision ranged from 0.27 - 1.10

39、%RSD,贵金属分析4 hours stability test,Precision ranged from 0.92 - 1.09 %RSD,Copper alloy sample樣品前處理,Use 0.1 g sample, accurately weighed dissolve in 5 mL HCl and 5 mL HNO3 Make up to 100 mL,铜合金的分析by Axial Vista,ElementMeasuredExpected (mg/L) (mg/L) MicroCo4.65 Cr0.170.2 K1.52 Si0.40.3 Al4.65 Na11.812 M

40、inorAs151150 Ni159 150 Fe19.920,矿石分析 ( axial Vista)Reference Material GS-12,ElementFound Certified (mg/L) (mg/L) TracesAg0.30.4 As6.36.4 Ba3.73.8 Bi1.01.5 Cr3.53.4 Mo0.140.17 P6.56.9 Sc0.120.14 Sr0.680.66 V2.02.3,矿石分析 ( axial Vista)Reference Material GS-12,ElementFound Certified (mg/L) (mg/L) Majors

41、Al397399 Ca125126 Fe18551870 K10596 Mg107108 Mn6063 Ni16.216 Pb6367 S301305,Geochemical地質化學分析,鱼和贝类的样品分析,分析条件,鱼类和贝类的肉质样品 使用硝酸消解 最终在8% HNO3中浓缩处理 标样在8% HNO3中制备,仪器条件,Power1.3 kW Plasma gas15 L/min Auxiliary gas1.5 L/min Nebulizer typeglass concentric Nebulizer pressure215 kPa Pump speed15 rpm Uptake rat

42、e1.0 mL/min Integration time5.0 seconds Replicates3 Background CorrectionOff peak and fitted,分析结果Fish Reference Materials,ElementFoundCertified (g/L) (g/L) 8G-2Se4030 As37.820 Cd2.012 Pb20.420 8G-5Se345300 As224200 Cd20.320 Pb193.2200,分析结果Water Samples,EPA 4EPA 12 Element Found CertifiedFound Certified (mg/L)(mg/L)(mg/L) (mg/L) As 0.0400.025

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论