ATV61 APOGEE FLN P1 card VW3A3314-EN(bbv10543)使用说明书手册_第1页
ATV61 APOGEE FLN P1 card VW3A3314-EN(bbv10543)使用说明书手册_第2页
ATV61 APOGEE FLN P1 card VW3A3314-EN(bbv10543)使用说明书手册_第3页
ATV61 APOGEE FLN P1 card VW3A3314-EN(bbv10543)使用说明书手册_第4页
ATV61 APOGEE FLN P1 card VW3A3314-EN(bbv10543)使用说明书手册_第5页
已阅读5页,还剩32页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Altivar®61

User'smanual

Retainforfutureuse

APOGEE®FLNP1card

VW3A3314

Contents

1.ImportantInformation_______________________________________________________________________________________4

2.Beforeyoubegin___________________________________________________________________________________________5

3.Introduction_______________________________________________________________________________________________7

4.Documentationstructure_____________________________________________________________________________________8

5.Notation_________________________________________________________________________________________________9

6.Quickstart_______________________________________________________________________________________________10

7.Hardwaresetup__________________________________________________________________________________________117.1.Receipt____________________________________________________________________________________________117.2.Hardwaredescription_________________________________________________________________________________117.3.Busvoltagemeasurementprocedure_____________________________________________________________________127.4.Installingthecardinthedrive___________________________________________________________________________12

8.Connectingtothebus______________________________________________________________________________________138.1.Cableroutingpractices________________________________________________________________________________138.2.Networkconfiguration_________________________________________________________________________________148.3.Cardconnectorpinout________________________________________________________________________________14

9.Configuration____________________________________________________________________________________________159.1.Communicationparameters____________________________________________________________________________159.2.Control____________________________________________________________________________________________169.3.Communicationconfiguration___________________________________________________________________________239.4.Monitoredparameters_________________________________________________________________________________24

10.Diagnostics_____________________________________________________________________________________________2510.1.Checkingtheaddress________________________________________________________________________________2510.2.Checkingthecommunication__________________________________________________________________________2510.3.LEDs_____________________________________________________________________________________________2510.4.Control-Command_________________________________________________________________________________2610.5.Communicationinterruptions__________________________________________________________________________2710.6.Optioncardhardwareconditions_______________________________________________________________________27

11.Networkobjects_________________________________________________________________________________________2811.1.LogicalAnalogInput(LAI)Summary____________________________________________________________________2811.2.LogicalAnalogOutput(LAO)Summary__________________________________________________________________3011.3.LogicalDigitalInput(LDI)Summary_____________________________________________________________________3111.4.LogicalDigitalOutput(LDO)Summary__________________________________________________________________33

12.Messageboxfunctionpoints_______________________________________________________________________________3512.1.ATV61Parameteraccesspointtable____________________________________________________________________3512.2.FLNP1StatusCode_________________________________________________________________________________35

13.Reports________________________________________________________________________________________________36

Whileeveryprecautionhasbeentakeninthepreparationofthisdocument,SchneiderElectricSAassumesnoliabilityforanyomissionsorerrorsitmaycontain,norforanydamagesresultingfromtheapplicationoruseoftheinformationherein.

Theproductsdescribedinthisdocumentmaybechangedormodifiedatanytime,eitherfromatechnicalpointofvieworinthewaytheyareoperated.Theirdescriptioncaninnowaybeconsideredcontractual.

3

1.ImportantInformation

NOTICE

Readtheseinstructionscarefully,andlookattheequipmenttobecomefamiliarwiththedevicebeforetryingtoinstall,operate,ormaintainit.Thefollowingspecialmessagesmayappearthroughoutthisdocumentationorontheequipmenttowarnofpotentialhazardsortocallattentiontoinformationthatclarifiesorsimplifiesaprocedure.

TheadditionofthissymboltoaDangerorWarningsafetylabelindicatesthatanelectricalhazardexists,whichwillresultinpersonnaliftheinstructionarenotfollowed.

Thisisthesafetyalertsymbol.Itisusedtoalertyoutopotentialpersonalinjuryhazards.Obeyallsafetymessagesthatfollowthissymboltoavoidpossibleinjuryordeath.

DANGER

DANGERindicatesanimminentlyhazardoussituation,which,ifnotavoided,willresultindeathorseriousinjury.

WARNING

Warningindicatesapotentiallyhazardoussituation,which,ifnotavoided,canresultindeath,seriousinjury,orequipmentdamage.

CAUTION

CAUTIONindicatesapotentiallyhazardoussituation,which,ifnotavoided,canresultininjuryorequipmentdamage.

PLEASENOTE

Theword"drive"asitisusedinthismanualreferstothecontrollerportionoftheadjustablespeeddriveasdefinedbyNEC.

Electricalequipmentshouldbeinstalled,operated,serviced,andmaintainedonlybyqualifiedpersonnel.NoresponsibilityisassumedbySchneiderElectricforanyconsequencesarisingoutoftheuseofthismaterial.

©2008SchneiderElectricAllRightsReservedReserved.

4

2.Beforeyoubegin

Readandunderstandtheseinstructionsbeforeperforminganyprocedurewiththisdrive.

DANGERHAZARDOFELECTRICSHOCK,EXPLOSION,ORARCFLASH

•ReadandunderstandthismanualbeforeinstallingoroperatingtheAltivar61drive.Installation,adjustment,repair,andmaintenancemustbeperformedbyqualifiedpersonnel.

•Theuserisresponsibleforcompliancewithallinternationalandnationalelectricalcoderequirementswithrespecttogroundingofallequipment.

•Manypartsofthisdrive,includingtheprintedcircuitboards,operateatthelinevoltage.DONOTTOUCH.Useonlyelectricallyinsulatedtools.

•DONOTtouchunshieldedcomponentsorterminalstripscrewconnectionswithvoltagepresent.

•DONOTshortacrossterminalsPA/+andPC/–oracrosstheDCbuscapacitors.

•Beforeservicingthedrive:

-Disconnectallpower,includingexternalcontrolpowerthatmaybepresent.-Placea“DONOTTURNON”labelonallpowerdisconnects.

-Lockallpowerdisconnectsintheopenposition.

-WAIT15MINUTEStoallowtheDCbuscapacitorstodischarge.Thenfollowthe“BusVoltageMeasurementProcedure”page12toverifythattheDCvoltageislessthan42V.ThedriveLEDsarenotindicatorsoftheabsenceofDCbusvoltage.

•Installandcloseallcoversbeforeapplyingpowerorstartingandstoppingthedrive.

Failuretofollowtheseinstructionswillresultindeathorseriousinjury.

DANGERUNINTENDEDEQUIPMENTOPERATION

•Testandensurethatanychangesmadetotheparametersettingsdonotpresentanydangertopersonnelandequipmentduringdriveoperation.

•DonotusethisAPOGEE®FLNP1optioncardwithATV61drivefirmwareearlierthanVersionV1.6IE18.Theseversionswillnotdetectaninoperativecard.

Failuretofollowtheseinstructionswillresultindeathorseriousinjury.

WARNINGDAMAGEDDRIVEEQUIPMENT

Donotoperateorinstallanydriveordriveaccessorythatappearsdamaged.

Failuretofollowtheseinstructionscanresultindeath,seriousinjuryoradditionalequipmentdamage.

5

2.Beforeyoubegin

WARNINGLOSSOFCONTROL

•Thedesignerofanycontrolschememustconsiderthepotentialfailuremodesofcontrolpathsand,forcertaincriticalcontrolfunctions,provideameanstoachieveasafestateduringandafterapathfailure.Examplesofcriticalcontrolfunctionsareemergencystopandovertravelstop.

•Separateorredundantcontrolpathsmustbeprovidedforcriticalcontrolfunctions.

•Systemcontrolpathsmayincludecommunicationlinks.Considerationmustbegiventotheimplicationsofunanticipatedtransmissiondelaysorfailuresofthelink.a

•EachimplementationofanATV61APOGEE®FLNP1optioncardmustbeindividuallyandthoroughlytestedforproperoperationbeforebeingplacedintoservice.

Failuretofollowtheseinstructionscanresultindeath,seriousinjury,oradditionalequipmentdamage.

a.Foradditionalinformation,refertoNEMAICS1.1(latestedition),“SafetyGuidelinesfortheApplication,Installation,andMaintenanceofSolidStateControl”andtoNEMAICS7.1(latestedition),“SafetyStandardsforConstructionandGuideforSelection,InstallationandOperationofAdjustable-SpeedDriveSystems.”

6

3.Introduction

ThankyouforpurchasingtheAPOGEE®FLNP1optioncard(VW3A3314)forAltivar61drive.

IMPORTANT:thiscommunicationoptioncardisfullysupportedwiththeversionV1.6IE18oftheAltivar61firmware.

ByInstallingthisboardintotheAltivar61,datacommunicationcanbemadewithahostcomputerorotherdeviceviaAPOGEE®FLNP1network.

Thecommunicationcardhasa4poleopenstyleconnectorforconnectiontothenetwork:A,B,GND,SCR.

DataexchangesgiveaccesstotheseAltivar61functions:•Control(start,stop,reset,setpoint),

•Monitoring(status,current,voltage,thermalstate...),•Diagnostics(alarms).

Thegraphicdisplayterminalortheintegrateddisplayterminalcanbeusedtoaccessnumerousfunctionsforcommunicationconfigurationanddiagnostics.

7

4.Documentationstructure

bAPOGEE®FLNP1manual

ThepresentAPOGEE®FLNP1usermanualdescribes:•connectiontoAPOGEE®FLNP1,

•configurationofthecommunication-specificparametersviatheintegratedHMIorthegraphicHMI,•diagnostics,

•networksvariables.

YouwillalsofindimportantinformationinotherAltivar61technicaldocuments.TheyareavailableontheWebsite

HYPERLINK

www.schneider-

HYPERLINK

andontheCDROMdeliveredwitheachdrive.

bInstallationmanual

Theinstallationmanualdescribes:

•howtoassemblethedrive(particularlyhowtomounttheAPOGEE®FLNP1card),•howtoconnectthedrive.

bProgrammingmanual

Theprogrammingmanualdescribes:

•thefunctionsandparametersofthedrive,

•howtousethedriveHMI(integratedHMIandgraphicHMI).

bCommunicationparametersmanual

TheCommunicationparametersmanualdescribes:

•theoperatingmodesspecifictocommunication(CiA402statechart),

•theinteractionbetweencommunicationandlocalcontrol(HMIandterminals),

•thedriveparameterswithspecificinformationforuseviaacommunicationnetwork(addresses,formats,etc).

WhenusingtheAPOGEE®FLNP1card,somesectionsoftheCommunicationparametersmanualarenotrelevant:-profiles,

-I/Oprofile

-CiA402profile.

ThedescriptionofdriveparametersisusefulonlyifyouusetheparametersaccessfunctionoftheAPOGEE®FLNP1(MBOXREAD,MBOXWRITE,MBOXPARAM,MBOXDATA).

8

5.Notation

bDriveterminaldisplays

Thegraphicdisplayterminalmenusareshowninsquarebrackets.Example:[1.9COMMUNICATION].

Theintegrated7-segmentdisplayterminalmenusareshowninroundbracketswitha"-"attheend.Example:(COM-).

Parameternamesdisplayedonthegraphicdisplayterminalarewritteninsquarebrackets.Example:[Fallbackspeed]

Parametercodesdisplayedontheintegrated7-segmentdisplayterminalarewritteninroundbrackets.Example:(LFF).

bFormats

Hexadecimalvaluesarewrittenasfollows:16#or0xBinaryvaluesarewrittenasfollows:2#

bAbbreviations

O=OptionalM=Mandatory

9

6.Quickstart

Theintegrated7-segmentdisplayterminalmenusarenotshowninthistable.

Operation Referto

A Howtoresetthedrivetothefactorysettings:[1DRIVEMENU]

[1.12FACTORYSETTINGS]

•Select[Config.Source]:Macro-conf,

•Select[PARAMETERGROUPLIST]:All•Select[GotoFACTORYSETTINGS]

B HowtoconfigurethemainAPOGEE®FLNP1communicationparameters:Inthemenu:

[1DRIVEMENU]

[1.9COMMUNICATION][P1]

•Check[Address]tothedesiredAPOGEE®FLNP1address

C HowtoconfigurethedrivesothatcontrolcomesfromtheAPOGEE®FLNP1networkInthemenu:

[1DRIVEMENU][1.6COMMAND]

•Change[Ref.1channel]from"AI1"to"Com.card"

Programmingmanual

[1.12FACTORYSETTINGS](FCS-)

“Communicationparameters”,

page15

“Control”,page16

D MonitorandControlthedrivethroughtheAPOGEEFLNP1network 11.Networkobjectspage28•Controlstart/stopbythebinaryvalueCMDSTP.STRT,

•ControlthevelocitysetpointbytheanalogvalueINPUTREF1,

•ControldirectionofrotationbythebinaryvalueCMDFWD.REV,

•Monitorifthedriveiscontrolledvialocalorremote(APOGEE®FLNP1)bythebinaryvalueFLNLOCCTLACT,

•Monitortherunning/stoppedstatebythebinaryvalueSTOP.RUN,

•MonitortheactualdirectionofrotationbythebinaryvalueFWD.REV,

•MonitortheactualspeedorfrequencybytheanalogvalueSPEEDorPCTOUTPUT.

Detectedfaultmanagement:

•MonitortheoperatingstatebythebinaryvalueOK.FAULT,•MonitorthedetailbytheanalogvalueERRORSTATUS,

•RemoteresetthecommunicationcardbythebinaryvalueRESETFAULT.

E Switchlocal/remotebythedriveHMI

PressF4key(markedTK)toswitchalternatelyfrombetweenAPOGEE®FLNP1andHMI.

Therightoftheupperdisplayline:

-REM:controlbyAPOGEE®FLNP1,-LOC:controlbyHMI.

F MonitoranddiagnosethestatusoftheAPOGEEFLNP1networkcommunicationbythedriveHMII

Inthemenu:

[1DRIVEMENU][1.2-MONITORING]

[COMMUNICATIONMAP][DIAGNETWORK]

G DiagnoseAPOGEE®FLNP1communicationbythedriveHMIInthemenu:

[1DRIVEMENU][1.2-MONITORING]

[COMMUNICATIONMAP]

•CheckthattheCommandChannelisCom.card,•CheckthatActiveref.channelisCom.card.

H DisablenetworkfaultdetectionfortestingInthemenu:

[1DRIVEMENU]

[1.8FAULTMANAGEMENT](FLt-)

Configure[COM.FAULTMANAGEMENT]to[Ignore].

ProgrammingmanualGraphicdisplayterminal

Descriptionofthegraphicscreen

“Checkingthecommunication”,

page25

“Checkingthecommunication”,

page25

Programmingmanual

[1.8FAULTMANAGEMENT](FLt-)

10

7.Hardwaresetup

7.1.Receipt

•Checkthatthecardreferenceprintedonthelabelisthesameasthatonthedeliverynotecorrespondingtothepurchaseorder.•Removetheoptioncardfromitspackagingandcheckthatithasnotbeendamagedintransit.

ElectrostaticPrecautions

CAUTIONSTATICSENSITIVECOMPONENTS

TheAPOGEE®FLNP1optioncardcanbedamagedbystaticelectricity.Observetheelectrostaticprecautionsbelowwhenhandlingcircuitboardsortestingcomponents.

Failuretofollowtheseinstructionscanresultininjuryorequipmentdamage.

Observethefollowingprecautionsforhandlingstatic-sensitivecomponents:

•Keepstatic-producingmaterialsuchasplastic,upholstery,andcarpetingoutoftheimmediateworkarea.•StoretheAPOGEE®FLNP1cardinitsprotectivepackagingwhenitisnotinstalledinthedrive.

•WhenhandlingtheAPOGEE®FLNP1card,wearaconductivewriststrapconnectedtothecardthroughaminimumof1megohmresistance.

•Avoidtouchingexposedconductorsandcomponentleadswithskinorclothing.

7.2.Hardwaredescription

Connectortothedrive

ReservedforSchneiderinternaluse

APOGEE®FLNP1LEDindicator

Panelmountingtabs

ReservedforSchneiderinternaluse

GroundPlate

TerminationresistorSW(SW102)

APOGEE®FLNP1Connector

11

7.Hardwaresetup

7.3.Busvoltagemeasurementprocedure

Beforeworkingonthedrive,removeallpowerandwait15minutestoallowtheDCbustodischarge.ThenmeasuretheDCbusvoltagebetweenthePA/+andPC/–terminals.

DANGERHAZARDOFELECTRICSHOCK,EXPLOSION,ORARCFLASH

Readandunderstandtheprecautionsin“Beforeyoubegin”onpage5beforeperformingthisprocedure.

Failuretofollowtheseinstructionswillresultindeathorseriousinjury.

TheDCbusvoltagecanexceed1,000Vdc.Useaproperlyratedvoltage-sensingdevicewhenperformingthisprocedure.TomeasuretheDCbusvoltage:

1Disconnectallpower.

2Wait15minutestoallowtheDCbustodischarge.

3MeasurethevoltageoftheDCbusbetweenthePA/+andPC/–terminalstoensurethatthevoltageislessthan42Vdc.

4IftheDCbuscapacitorsdonotdischargecompletely,contactyourlocalSchneiderElectricrepresentative.Donotrepairoroperatethedrive.

7.4.InstallingthecardinthedriveRefertotheInstallationmanual.

12

8.Connectingtothebus

8.1.Cableroutingpractices

WARNINGIMPROPERWIRINGPRACTICES

•FollowthewiringpracticesdescribedinthisdocumentinadditiontothosealreadyrequiredbytheNationalElectricalCodeandlocalelectricalcodes.

•Checkthepowerconnectionsbeforeenergizingthedrive.

•Ifreplacinganotherdrive,verifythatallwiringconnectionstotheATV61drivecomplywithallwiringinstructionsinthismanual.

Failuretofollowtheseinstructionscanresultindeath,seriousinjury,orequipmentdamage.

WhenwiringAltivar61drivestoaAPOGEE®FLNP1network,followallwiringpracticesrequiredbynationalandlocalelectricalcodes.Alsoobservethefollowingguidelines:

•Avoidareasofhightemperature,moisture,vibration,orothermechanicalstress.

•Securethecablewherenecessarytopreventitsweightandtheweightofothercablesfrompullingortwistingthecable.

•Usecableducts,raceways,orotherstructurestoprotectthecable.Usethesestructuresforsignalwiringpaths.Theymustnotcontainpowerwiring.

•Avoidsourcesofelectricalinterferencethatcaninducenoiseintothecable.Usethemaximumpracticableseparationfromsuchsources.

Whenplanningcableroutingwithinabuilding,followtheseguidelines:

•Maintainaminimumseparationof1m(3.3ft)fromthefollowingequipment:-airconditionersandlargeblowers,

-elevatorsandescalators,-radiosandtelevisions,

-intercomandsecuritysystems,

-fluorescent,incandescent,andneonlightingfixtures.

•Maintainaminimumseparationof3m(9.8ft)fromthefollowingequipment:-lineandmotorpowerwiring,

-transformers,-generators,

-alternators.

Whenwiringinelectricalequipmentroomsorlargeelectricalequipmentline-ups,observethefollowingguidelinesforcablesegregationandseparationofcircuits:

•Usemetallicconduitfordrivewiring.Donotruncontrolnetworkandpowerwiringinthesameconduit.

•Separatenon-metallicconduitsorcabletraysusedtocarrypowerwiringfrommetallicconduitcarryinglow-levelcontrolnetworkwiringbyatleast300mm(12in).

•Separatemetallicconduitscarryingpowerwiringorlow-levelcontrolnetworkwiringbyatleast80mm(3in).

•Crossthemetallicconduitsandnon-metallicconduitsatrightangleswheneverpowerandcontrolnetworkwiringcross.

•Attenuateconductedemissionsfromthedrivetothelineinsomeinstallationstohelppreventinterferencewithtelecommunication,radio,andsensitiveelectronicequipment.Suchinstancesmayrequireattenuatingfilters.ConsulttheAltivarcatalogforselectionandapplicationofthesefilters.

Maximumlengthofbus

Maximumnumberofstations

1000m(3280ft)at19,200bps(9600bpsmax.withAPOGEE®FLNP1)

32stations,i.e,31slaves(withoutrepeater)

13

8.Connectingtothebus

8.2.Networkconfiguration

Makeupthenetworkasfollows:

-Transmit/receivesignals(A,B)

Connectalltransmit/receivedatalinestoensureproperdatatransmission.-Signalcommon(GND)

GNDisthesignalcommon.

-Groundingtheshieldofthenetworkcable(SCR)

Connecttheshieldlinesofnetworkcable.Onlygroundtheshieldatonepointtohelppreventnoisecurrentsfrombeingcreatedandinterferingwithnetworkcommunications.

-Terminationresistor

Aterminationresistanceof120ohms+/-5%shouldbeconnectedateachofthetwoendsofthenetworksegment.TheATV61P1optioncardhasabuiltinterminatingresistor.Tousethisresistor,refertosection7.2.Hardwaredescription.

Atleastoneset,andnomorethantwosets,ofnetworkbiasresistorsshallexistforeachsegment.Thisoptionhaslocalbiasresistors.

*ItisrecommendedthattheSiemensBuildingAutomationFLNTrunkTerminator(PN:538-664)beusedandthatthenetworkterminationswitchontheAPOGEE®FLNP1card,SW102,besettoOFF.

N.B.:DonotconnecttheSCRterminaltothepowergroundofdrivesorotherunits.

Keepthenetworkcables20cmormoreseparatefromthepowercablestohelppreventfrommalfunctioningduetoelectromagneticnoise.

8.3.Cardconnectorpinout

ContactSignalB+A-

GNDGNDSCRShield

•Thecablesheathshouldbestrippedoffbyabout10mm(0.4in).

•Forwiringtheterminals,useaslottedscrewdriverwitha0.6mm(0.02in)thickand3.5mm(0.14in)widthblade.•Tighteningtorquefortheterminalblockis0.5to0.6N·m(0.37-0.44ft·lb).

14

9.Configuration

9.1.Communicationparameters

Configurethefollowingparametersinthe[1.9-COMMUNICATION](COM-)menu,[P1](P1-)submenu.Theseparameterscanonlybemodifiedwhenthemotorisstopped.

Parameter

[Address](AdrC)

[Baudrate](1)(Bdr)

[Networktimeout](tLP)

Possiblevalues

0to99

0,99:disabled.

[4800Bd](4-8)[9600Bd](9_6)[19200Bd](19_2)[38400Bd](38_4)[57600Bd](57_6)[76800Bd](76_8)

2.0to60.0seconds

TerminalDisplay[99](99)

[4800Bd](4-8)[9600Bd](9_6)[19200Bd](19_2)[38400Bd](38_4)[57600Bd](57_6)[76800Bd](76_8)

[2](2)

Defaultvalue99

9600

10.0

(1)Modificationswillonlybetakenintoaccountbythedriveafterpowercycled.

15

9.Configuration

9.2.Control

Numerousconfigurationsarepossible.Formoreinformation,refertotheProgrammingmanualandtheCommunicationparametersmanual.

Thefollowingconfigurationsarejustsomeofthepossibilitiesavailable.

bAllowedconfigurations

IfthedriveisonlymonitoredbyAPOGEE®FLNP1:Thereisnoconfigurationconstraint.

IfthedriveiscontrolledbyAPOGEE®FLNP1:

Theparameter[Profile](CHCF)mustbeconfiguredto[Notsepar.](SIM)or[Separate](SEP).[Notsepar.](SIM)isthedefaultvalue.Itisnotallowedtoconfiguretheparameter[Profile](CHCF)tothevalue[8serie](SE8)or[I/Oprofile](IO).

Ifanunallowedconfigurationisset,thedrivewilltripon[Externalfaultcom.](EPF2).

However,iftheI/Oprofileisconfiguredandnocommandchannelsareassignedtothecommunicationcard,thedrivewillnottrip.

bControlviaAPOGEE®FLNP1

ThecommandandthesetpointcomefromAPOGEE®FLNP1.

APOGEE®FLNP1

APOGEE®FLNP1

Configurethefollowingparameters:

ParameterProfile

Setpoint1andcommandconfiguration

Value

Notseparate

Networkcard

Comment

Boththestart/stopcommandandspeedreferencecomefromthesamechannelsetin[Ref.1chan].Therunstart/stopcommandfollowstheCiA402profile.

ThesetpointandcommandcomefromAPOGEE®FLNP1.

Configurationviathegraphicdisplayterminalortheintegrateddisplayterminal:

Menu

[1.6-COMMAND](CtL-)

Parameter[Profile](CHCF)

[Ref.1chan](Fr1)

Value

[Notsepar.](SIM):defaultvalue

[Com.card](nEt)

16

9.Configuration

bControlviaAPOGEE®FLNP1orviatheterminals

ThecommandandthesetpointbothcomefromAPOGEE®FLNP1ortheterminals.Dependingontheconfiguration,theapplicationfunctionsareorarenotused.

TwodifferentcasesaredescribedbelowshowinghowthesetpointisswitchedfromAPOGEE®FLNP1totheterminals.Inthefirstcase,theapplicationfunctionsapplybutnotinthesecondone.

APOGEE®FLNP1

APOGEE®FLNP1

Analternatesolutioncanalsobeused:thesetpointandthecommandcanbeswitchedseparatelyfromthenetwork.TwoLogicalDigitalOut(LDO)arededicatedtothisfunction:LDO#68andLDO#69.These2pointscommandC312andC313respectively.

APOGEE®FLNP1

LDO#68(bitC312)FLN.LOC.CTL

LDO#69(C313)APOGEE®FLNP1 FLN.LOC.REF

Note:

Whenusingthepreviousoperatingmode,itisimportantthattheP1mastercontrollermonitorsthedrivestate(bypollingsignificantpoints).Thereforewhenthecontroland/orthesetpointareswitchedbacktoAPOGEE®FLNP1,thecontrollerwillreactproperly(whentheDriveisswitchedtolocalmode,alloverriddencommandsarereleased).

Important:Inthiscase,acommunicationinterruptionmessagecanappeariftheconnectionisinterrupted.

17

9.Configuration

SwitchingofcontrolandsetpointfromAPOGEE®FLNP1totheterminalswithapplicationfunction

Inthisexample,logicinputLI5isusedtoswitchthecontrolandthesetpointbetweenAPOGEE®FLNP1andtheterminals.Whenswitchedtotheterminals,theapplicationfunctions(summing…)remainactive.

APOGEE®FLNP1

Configurethefollowingparameters:

ParameterProfile

Setpoint1configuration

Value

Separateprofile

Networkcard

Comment

Thecommandandthesetpointcancomefromdifferentchannels.

Setpoint1comesfromAPOGEE®FLNP1.

Setpoint1BconfigurationAnaloginput1ontheterminalsSetpoint1BcomesfrominputAI1ontheterminals.

Setpointswitching InputLI5 InputLI5switchesthesetpoint(1↔1B).C312(LDO#68)canalsobeconfiguredforthecommandswitching

Command1configurationNetworkcard

Command2configurationTerminals

Command1comesfromAPOGEE®FLNP1.

Command2comesfromtheterminals.

Commandswitching InputLI5 InputLI5switchesthecommand.C313(LDO#69)canalsobeconfiguredforthesetpoint

Setpoint1Bisdirectlyconnectedtothefunctionsofthedrive.IfthereferenceisswitchedtotheterminalsusingSetpoint1B,thefunctionsthataffectthereference(summing,PID,etc)areactive.

Configurationviathegraphicdisplayterminalortheintegrateddisplayterminal:

Menu

[1.6-COMMAND](CtL-)

[1.7-APPLICATIONFUNCT.](FUn-)[REFERENCESWITCH]

Parameter[Profile](CHCF)

[Ref.1channel](Fr1)[Cmdchannel1](cd1)[Cmdchannel2](cd2)[Cmdswitching](CCS)[Ref.1Bchannel](Fr1b)

[Ref.1Bswitching](rCb)

Value

[Separate](SEP)[Com.card](nEt)[Com.c

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论