




免费预览已结束,剩余16页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
河南理工大学本科毕业设计 Abstract摘要本设计是对焦作市某办公楼的空调系统设计,设计中, 我们根据当地的实际情况,结合自己的实践经验,综合考虑分析,最终确定:夏季,我们采用空调制冷,对于一层大厅用组合式空调器;其余各房间统一用制冷机组制冷,风机盘管加新风的供给方式。冬季,我们通过板式换热器,引用市政外网供暖。焦作市属于夏热冬冷地区,对于一层大厅的组合式空调器,其传热介质为空气,要注意冬季的除霜、防冻问题。 风机盘管要接冷凝水管,对冷凝水进行处理。关键词:空调制冷;板式换热器;风机盘管;冷凝水VIAbsractthe design is the air conditioningsystem designof an office building, in JiaozuoCity,the design, we haveaccording to the localactual situation, combined with their own practical experience, considering the analysis, and finally determined: the summer, we use air conditioning and refrigeration, for the lobby with a combination of air conditioner; the rest of the room uniform cooling with refrigeration unit, fan coil plus fresh air supply means. Winter, we through the plate heat exchanger, refer to the external network of municipal heating. Jiaozuo is hot in summer and cold winter zone, the lobby of the combined air conditioner, the heat transfer medium is air, pay attention to defrost the winter, antifreeze problem. Condensate pipe fan coil to take on the condensation of water for processing.Keyword:refrigeration; plate heat exchanger; fan coil; condensationof water河南理工大学本科毕业设计 目录目录第1章 绪 论11.1 办公楼宇用电现状11.2 办公楼宇用电症状分析1第2章 原始资料及设计参数42.1 题目42.2 建设地点42.3 工程概况42.3.1 结构形式:42.3.2 建筑装饰:42.3.3 建筑做法及用料说明:52.3.4 门窗明细表:62.4 气象资料62.5 室内设计参数72.6 其他要求7第3章 设计冷、热、湿负荷的计算83.1 冷负荷理论根据83.1.1 房间冷负荷的构成83.1.2 房间湿负荷的构成83.1.3 冷负荷的计算方法与主要计算公式83.2 建筑物一层冷负荷(以所取一层的大办公室为例)103.2.1 通过围护结构传入室内的热量形成的冷负荷103.2.2 通过外窗进入的太阳辐射热153.2.3 由人体、照明、设备散热形成的冷负荷153.3 建筑物制冷系统总冷负荷193.4 建筑物一层湿负荷(以所取一层大办公室为例)193.4.1 人体散湿量193.4.2 敞开水表面蒸发散湿量193.5 建筑物一层热负荷(以所取一层大办公室为例)203.5.1 基本耗热量203.5.2 通过门、窗缝的冷风渗透耗热量223.5.3 冷风侵入耗热量233.5.4 建筑物采暖热负荷汇总243.6 建筑物其他房间冷、热、湿负荷243.6.1 房间负荷统计表见附表3-2243.6.2 楼层负荷统计表见附表3-324第4章 系统方案的确定254.1 空调系统的对比性分析254.2 空调系统选用规范与要求274.3 此设计系统方案的确定28第5章 设备的计算选型295.1 空调冷热源方案的选择295.2 机组设备选型305.2.1 选型依据305.3 空气处理过程345.3.1 风机盘管加新风系统的空气处理过程345.3.2 全空气的空气处理过程365.4 风机盘管的选型计算375.4.1 风机风管处理风量计算(以一层大办公室为例)375.4.2 根据计算进行风机盘管的选择37第6章 空调风系统的设计及水力计算416.1 送回风形式的确定416.1.1 送风口风速要求416.1.2 气流组织的基本要求426.1.3 房间送回风形式426.2 气流组织的设计计算436.2.1 计算方法436.2.2 气流组织的计算计校核446.3 风管系统的设计及计算。456.3.1 计算方法456.3.2 建筑物二风系统水力计算506.3.3 建筑物三至五层风系统水利计算51第7章 空调水系统的设计和水力计算547.1 空调水系统的设计547.1.1 冷冻水系统的设计547.1.2 冷却水系统的设计557.2 计算方法567.3 建筑物水系统水力计算56第8章 制冷机房的布置及相关设备的选型658.1 系统定压设计658.2 冷冻水泵计算选型658.3 冷却水泵678.4 补给水泵设计688.5 冷却塔的设计选型688.6 冷却水处理设计698.7 换热器的设计计算69第9章 管道的保温与系统的消声减震设计719.1 管道保温719.1.1 保温材料的种类及选择719.1.2 保温层的结构组成719.2 消声隔振措施72致谢词73河南理工大学本科毕业设计 第一章 绪 论第1章 绪 论当前,我国正在全国范围内开展节能减排大行动,建筑楼宇节能日益排在突出位置,在积极探索节电节能新途径中,借助专业节电技术节能降耗日益成为众多建筑楼宇企业实现节电目标的“终南捷径”。1.1 办公楼宇用电现状 一组来自国家有关部门的调查数字显示: 我国办公楼宇年电力消耗总量占全国总消耗量的10%,能源费用超过800亿元,主要包括政府机关、企事业单位、商业写字楼等办公楼宇,大部分办公楼宇的全年用电量在100KWH以上,其中空调用电在45-50%;用户室内用电35-40%;公用电费支出10-15%。目前,国内楼宇大多采用低成本的节能措施,主要是通过简单的更换低耗电设备或是行政管理手段进行,例如“更换灯的类型”、“随手关灯”、“降低空调温度” 等等,这些被动式的节能手段要么节能不节钱,要么收效甚微,节能效率不超过10%,并没有从根本上解决系统电能的损失,若投资进行技术性改造,采用不同技术手段进行组合,以综合降低系统不同形式的电能损失,则可以达到15%以上的综合节能效果。1.2 办公楼宇用电症状分析 (1)供电系统效率低1)变压器效率低:办公楼宇变压器使用效率不高,特别是晚上变压器几乎空载运行,造成变压器自身损耗大,电压变化率高;2)供电线路损耗大:因办公楼宇用电设备多,供电线路分支多、长,视在功率大,存在较大的集肤效应损耗及热阻线损,导致末端电压降大,电能使用效率明显下降,并存在一定的安全隐患;(2)用电设备能耗利用率不高1)空调设备用电(柜式或中央空调):首先,办公楼宇空调系统在设计选型时,大多预计留了20%左右的余量,但正常运行时很少完全运行在满负荷状态;其次,空调水循环系统实际运行时处于最大设计固定流量下工作,不随负荷变化而变化,无法达到主机、辅机和末端舒适温度三者达到合理的动态自动调节,导致电能利用率低,电能浪费严重。2)照明及其它设备用电:办公楼宇照明用电和其它用电设备大多是感性负载,功率因数多在0.5-0.8之间,存在大量的无功损耗,且用电设备多为单相220V供电,线路中都存在着严重的三相不平衡,造成零序电流过大,造成电耗的损失增加,也大大降低了系统的电能使用效率。(3)用电设备复杂,电力品质差办公楼宇内的用电设备数量与种类众多,主要用电设备有:照明(节能灯、日光灯等),空调(柜式和中央空调)、办公设备、电脑、三相电机(风机和水泵)、电加热负载和其它混合负载等。其中大量电力电子装置(如电脑、办公设备、通信设备)等非线性负载的使用,导致负荷严重非线形,产生电压陷波、电压突变、浪涌、瞬变、谐波(其中以3次谐波为主)等。同时消耗大量的无功功率,导致功率因数较低,使供电电压波形发生畸变,电力污染严重,用电品质差,大大降低了电能的使用效率,也影响用电设备的使用寿命和使用安全。办公楼宇电费成本控制解决方案多年来通过一体化节能管理方式,为国内众多办公楼宇成功有效的提升了电能使用效率,降低了电费开支。办公楼宇电费成本控制解决方案的实施步骤1)节能信息咨询;节能项目经理及技术工程师免费为办公楼宇用户单位提供节能信息咨询服务,例如如何建立节能管理机制、办公楼宇节能技术改造经济分析、节能相关技术的咨询及培训等。2)能源效率审计;节能技术工程师为办公楼宇用电状况进行全程监测,对供电系统中的变压器、线路、设备、电网质量、能效管理方式等进行全面测试或了解,对用户单位能源使用效率进行综合评审和计算。3)节能改造方案设计;工程师经过技术交流和数据分析后,针对办公楼宇的整体用电状况,量身设计出科学、高效、经济的节能改造方案,包括系统能效状况、节能空间测算、有效节能措施、节能产品组合选择、工程实施计划、节能效益分析及投资回报率等。4)制定投资方案;根据具体情况,制订多种节能工程项目实施计划供用户选择(例如是一次性全面改造,还是分期分批实施改造),并由此确定节能项目投资方案。5)设备组合采购;有着丰富的节能系列产品,针对办公楼宇的基本用电特点,我们将选用不同类型产品进行组合安装使用,以整体提升系统电能使用效率,达到全面降低电费开支的目的。6)施工方案设计;先进的节能技术和产品,对施工安装有着更严格的要求,项目组在节能项目施工前,将对用户单位现场进行详细了解和测算,并设计出科学、严谨的节能项目施工方案,内容包括施工时间、施工进度、项目分工、安装位置、安装工艺、防护要求、辅材规格等等,以保障节能项目实施达到最佳效果。7)施工安装及调试;严格按照节能项目施工方案要求进行现场施工,并在施工完毕后进行系统调试和试运行。8)节能及效益评估;节能项目实施后,选择科学合理的方式,进行数据收集和整理,对节能项目的综合效益进行评估,计算出包括节约的电费、节省的设备维护和更换费用等综合收益。74河南理工大学本科毕业设计 第2章 原始资料及设计参数第2章 原始资料及设计参数2.1 题目焦作市某综合楼空调工程设计2.2 建设地点焦作市高新区世纪大道路旁2.3 工程概况本建筑为一综合办公楼。总建筑面积为2982.36(以建筑定位轴线为起算边界。余同),共5层。首层层高4.2m,其余各层层高为3.3m。本办公楼设标准办公室40间,每间面积为21.6;大办公室4间,每间面积为36.00;套间办公室4间,每间面积为40.41;小会议室4间,每间面积为39.60;大会议室1间,面积为84.60。另外,底层设档案资料图书室及其阅览室、接待室、值班室、收发室,备用贮藏间等。二至五层各设备用房间3间,面积为19.8及21.6不等。该工程为多层钢筋混凝土框架建筑,建筑分类为丙类,设计使用年限50年。2.3.1 结构形式:钢筋混凝土框架结构,预应力空心板楼盖及屋盖,外墙为370粘土空心砖(底层为标砖),内墙为240粘土空心砖,独立柱基础。工程抗震设防烈度为7级。本建筑建设地段位于寒冷气候分区地区,外墙为370空心砖填满,外窗为塑钢双层5厚普通白玻璃,外门为彩钢板保温型自闭地弹簧门。2.3.2 建筑装饰:普通建筑装饰。外墙面砖,局部底层为挂贴花岗岩;内墙、平顶粉白,走廊局部及厕所卫生间平顶为轻钢龙骨铝合金板条吊顶;厕所卫生间内墙面为内墙面砖饰面。楼地面为铺地砖楼地面,内外门厅及内廊为抛光花岗岩楼地面。门窗:双层玻璃塑钢窗,内普通蜂窝板木门,外彩钢板保温外门,普通日关灯灯饰,内廊及门厅为吸顶灯灯饰。室内上下水管道为pvc工程塑料管,卫生洁具为中档陶瓷洁具。2.3.3 建筑做法及用料说明:表2-1 建筑物作法及用料说明表名称适用范围作法备注类别编号墙身全部详见结施砖墙墙身防潮层全部防水水泥沙浆防潮层潮1防水全部混凝土散3宽900室外台阶全部花岗岩台阶台9-A外墙饰面4.2米标高以下挂贴花岗岩墙面外30、31(A)分格、品种、色彩见文面其余全部外墙面砖外13颜色见立面,100100外墙面砖内墙饰面卫生间彩印瓷片内35200300,高2500其余全部乳胶漆内17白色窗台全部同相应的内墙内17墙脚全部厕所在地面水泥墙脚墙2高150地面铺地砖地面地29规格、品种特定楼梯间 门厅 内廊花岗岩地面地4规格、品种特定楼面全部铺地砖地面楼41规格、品种特定楼梯间,门厅花岗岩楼3规格、品种特定顶棚内廊及门厅铝合金条板吊顶棚31白色搭接式其余全部板底乳胶漆顶棚棚6白色屋面全部预制混凝土块保护层屋面屋12屋面防水层全部SBS次性沥青防水卷材级防水屋面保温层全部挤塑性聚苯乙烯保护层60厚,做法见说明书油漆木门、扶手油漆油3木本色外露金属管道及金属件银粉漆油242.3.4 门窗明细表:表2-2 建筑物门窗明细表类别门窗名称型号洞口尺寸门窗数量备注1层2至4层5层屋面合计塑钢窗C1CST60-78-BS180018502022324110C2CST60-18-B3060180023219总宽增加60,两侧均分C3CST60-12-B1200120022C4CST6013-B1000120011窗台高200彩色钢板门M1DM-391800300022内门乳白色,外门茶色M2DM-783900300011M3DM-281800270022M4DM-1718502400443521M5DM-202400240011315M6PM4-511500230011蜂窝木门M7M1-09219002100161731885中等调和漆,乳白色M8M3-0821800210011342.4 气象资料 图2-1 焦作市(取郑州市)气象参数表2.5 室内设计参数根据全国民用建筑工程设计技术措施-暖通空调.动力中对室内空调计算参数有具体的规定,对于民用建筑,室内设计参数如下(出于建筑节能和人体舒适性的考虑):夏季:室内温度为26,相对湿度65%,气流平均速度0.3m/s;冬季:卧室和起居室温度为18,浴室、走廊和楼梯温度取16,相对湿度不作要求(可以忽略),气流平均速度0.2m/s。2.6 其他要求要充分根据当地的实际情况,优先考虑利用新能源,以及建筑节能。焦作市属于西气东输工程二段,近两年,新引入西气东输工程供气,在设计中,可以优先考虑夏季空调,冬季燃气供热。河南理工大学本科毕业设计 第3章 设计冷、热、湿负荷计算第3章 设计冷、热、湿负荷的计算3.1 冷负荷理论根据 3.1.1 房间冷负荷的构成(1)通过围护结构传入室内的热量形成的冷负荷;(2)外窗瞬变传热和日射得热形成的冷负荷;(3)人体散热量形成的冷负荷;(4)照明散热量形成的冷负荷;(5)设备散热量形成的冷负荷;(本设计不考虑)(6)其它室内散热量形成的冷负荷。3.1.2 房间湿负荷的构成(1)人体散湿量; (2)其它室内散湿量。3.1.3 冷负荷的计算方法与主要计算公式冷负荷系数法,当计算某建筑物空调冷负荷时,则可按照条件查出相应的冷负荷温度与冷负荷系数,用稳定传热公式形式即可算出经围护结构传入热量所形成的冷负荷和日射得热形成的冷负荷。(1)人体冷负荷:由显热散热造成的冷负荷 = 群集系数 计算时刻空调房间的总人数 一名成年男子小时的显热散热量 人体显热散热量的冷负荷系数由潜热散热造成的冷负荷 = 群集系数 计算时刻空调房间的总人数 一名成年男子小时的潜热散热量 人体潜热散热量的冷负荷系数(2)人体湿负荷:湿负荷 = 0.001 群集系数 空调房间人数 一名成年男子小时散湿量(3)灯光冷负荷:灯光:灯具类型:暗装荧光灯,灯罩无通风孔;照明时间:8:00am6:00pm。每平方米照明安装功率指标:办公室40W/ m2,小会议室40W/ m2,大会议室40W/ m2左右,内廊及门庭顶层25W/ m2左右。(4)外墙冷负荷:冷负荷 Q = KFt- (3.1)其中: F - 外墙或屋面的面积; K 外墙或屋面的传热系数; t-作用时刻下,围护结构的冷负荷计算温差; -温度波的作用时间,级温度波作用于围护结构内表面的时间,h; 计算时间,h; 围护结构表面受到周期24小时谐性温度波作用内温度波传到内表面的时间延迟,h。(5)外窗冷负荷:该冷负荷可分为了两部分: 窗户瞬变传热得热形成的冷负荷和窗户日射得热形成的冷负荷窗户瞬变传热得热形成的冷负荷Qc, = Ft (3.2) 其中: t 计算时刻的负荷温差,F窗口面积,窗户日射得热形成的冷负荷 Qc, =XgXdXz FJn. (3.3)Xg 窗的有效面积系数;Xd 地点修正系数; Xz 窗的内遮阳系数;Jn. 计算时刻时,透过单位窗口面积的太阳总辐射形成的冷负荷。3.2 建筑物一层冷负荷(以所取一层的大办公室为例)3.2.1 通过围护结构传入室内的热量形成的冷负荷(1)墙体冷负荷冷负荷 Q = KFt- (3.4)表3-1 外墙为370黏土空心砖参数表 类型砖墙33-370-4传热系数材质名称(外-内)厚度导热修正系数夏季外传热系数0.48抹面胶浆61冬季外传热系数0.48聚苯板601内传热系数0.47砖墙3701传热衰减0.05水泥砂浆151传热延迟(h)14.2t-作用时刻下,围护结构的内外墙冷负荷计算温差。见附表3-1。表3-2 北墙外墙体逐时冷负荷时间面积F传热系数K传热延迟h衰减系数-逐时温差t-冷负荷Q1218.540.4814.20.0512980.0928418.540.4814.20.0514980.0928618.540.4814.20.0516980.0928818.540.4814.20.0518980.09281018.540.4814.20.0520871.19361218.540.4814.20.0522762.29441418.540.4814.20.0524762.29441618.540.4814.20.052653.39521818.540.4814.20.054653.39522018.540.4814.20.056762.29442218.540.4814.20.058762.29442418.540.4814.20.0510871.1936表3-3 东墙外墙体逐时冷负荷时间面积F传热系数K传热延迟h衰减系数-逐时温差t-冷负荷Q1225.20.4814.20.051213157.248425.20.4814.20.051412145.152625.20.4814.20.051612145.152825.20.4814.20.051811133.0561025.20.4814.20.052010120.961225.20.4814.20.05229108.8641425.20.4814.20.0524896.7681625.20.4814.20.0529108.8641825.20.4814.20.0549108.8642025.20.4814.20.05611133.0562225.20.4814.20.05812145.1522425.20.4814.20.051012145.152(2)外窗冷负荷窗取双层玻璃塑钢窗,其参数如下表3-4 所选窗户的参数表围护结构参数传热系数材质名称(外-内)厚度(mm)导热系数夏季外传热系数2.61平板玻璃51冬季外传热系数2.69热流水平120.72内传热系数2.25平板玻璃51传热衰减系数1透明色玻璃纸51传热延迟0.4此房间内墙放热衰减度2.0,,属于重型房间;楼板或地面上满铺织物地毯,属于轻型;综合考虑,此房间视为中性。根据逐时温差求得外窗逐时冷负荷:表3-5 北墙外窗逐时冷负荷时间面积F传热系数K室内设计温度tn衰减系数逐时温差t-冷负荷Q366.662.612611.424.3356486.662.612612.746.93302106.662.612614.985.17474126.662.612617.0121.6782146.662.612618.3144.27558166.662.612618.8152.96688186.662.612618.1140.79906206.662.612616.5112.9869226.662.612614.985.17474246.662.612613.560.8391(3)内墙、内门、楼板、地面冷负荷计算方法内墙,楼板,顶棚和地面形成的冷负荷,可概略按下式计算:Q = KF(twp+tjtN) (3.5)式中 twp-夏季空气调节室外计算日平均温度,;tN-室内空调计算温度,;tj-考虑太阳辐射热等因素的附加空气温升,可按附表3-3选取。1)房间南内墙冷负荷内墙为240黏土空心砖,F=23.31。表3-6 南内墙参数表砖墙(001001)传热系数材质名称(外-内)厚度(mm)导热系数夏季外传热系数1.97水泥砂浆201冬季外传热系数2.02砖墙2401内传热系数1.76水泥砂浆201传热衰减系数0.35外粉刷51传热延迟8.5Q4=23.311.97(30.8+2-26)=312.26076 W2)建筑物内门冷负荷建筑物内门为普通蜂窝板木门,其参数如下表3-7 内门参数表木(塑料)框夹板门和蜂窝夹板门传热系数材质名称(外-内)厚度(mm)导热系数夏季外传热系数2.5橡木枫树热流200.51冬季外传热系数2.57内传热系数2.17传热衰减系数0.99传热延迟0.8Q5=1.892.5(30.8+2-26)=32.13 W3)地面冷负荷楼梯间、门厅、内廊地面采用花岗岩地面;其余地面采用铺地砖地面。传热系数取值参考下表表3-8 几种典型地面不同地带的当量传热系数k地带 地面1: 地面2: 地面3: 地面4:水泥砂浆地面水泥砂浆地面聚苯板保湿地面普通聚苯板保温地面地带10.870.860.480.46地带20.470.470.350.34地带30.350.350.290.28地带40.290.290.250.25地带50.230.230.210.21地带60.200.200.180.18周边2m内的平均值0.500.490.350.33我们取地面3。则:Q6=(26+24)0.35(30.8+16-26)=145.6 W4)其他围护结构负荷在这里,我们认为相邻空调房间温度相同,即不考虑临室传热;一层、二层,二层、三层之间,也不考虑传热。5)围护结构负荷汇总表表3-9 围护结构负荷汇总表时间北墙外墙体Q1东墙外墙体Q2北外窗Q3内墙Q4内门Q4地面Q5冷负荷Q6680.0928145.15224.33564312.260732.13145.6739.5711880.0928133.05646.93302312.260732.13145.6750.07251071.1936120.9685.17474312.260732.13145.6767.3191262.2944108.864121.6782312.260732.13145.6782.82731462.294496.768144.27558312.260732.13145.6793.32871653.3952108.864152.96688312.260732.13145.6805.21681853.3952108.864140.79906312.260732.13145.6793.0492062.2944133.056112.9869312.260732.13145.6798.3282262.2944145.15285.17474312.260732.13145.6782.61183.2.2 通过外窗进入的太阳辐射热外窗太阳辐射热形成的逐时冷负荷可按下式计算:Qc, =XgXdXz FJn. (3.6)相关参数分别表3-10、3-11、3-12。取钢框双层5mm厚普通玻璃,内遮阳材料为灰白色活动铝百叶帘。则:外窗太阳辐射热形成的逐时冷负荷Q7:表3-13 外窗太阳辐射热形成的逐时冷负荷Q7时间面积F计算时刻辐射强度Jn.构造修正Xg内遮阳修正Xz地点修正Xd冷负荷Q763.33390.690.60.9148.927283.33510.690.60.9163.9818103.33750.690.60.9194.0908123.33900.690.60.91112.9090143.33900.690.60.91112.9090163.33730.690.60.9191.5817183.33700.690.60.9187.8181203.33240.690.60.9130.1091223.33160.690.60.9120.07273.2.3 由人体、照明、设备散热形成的冷负荷(1)人体散热形成的冷负荷1)由显热散热造成的冷负荷人体显热散热形成的冷负荷,可按下式计算: Q=nnq1X-T W (3.7)式中 n室内总人数;根据表3-14确定; n群集系数,见表3-15; q1不同室温和劳动性质时成年男子散热量,W,见表3-16; -T人员进入房间时到计算时刻的时间,h; X-T时间人体显热散热量的冷负荷系数,见表3-17;则:有显热散热造成的冷负荷Q8见下表表3-18 由显热散热造成的冷负荷Q8工作后小时数-Tnnq1X-T冷负荷Q8280.96610.70327.9360480.96610.80374.7840680.96610.1674.9568880.96610.2198.38081080.96610.23107.75042)由潜热散热造成的冷负荷,同理可得:表3-19 由潜热散热造成的冷负荷Q9工作后小时数-Tnnq1X-T冷负荷Q9280.96730.70392.4480480.96730.80448.5120680.96730.1689.7024880.96730.21117.73441080.96730.23128.9472(2)灯光照明散热形成的冷负荷照明散热形成的冷负荷可按下式计算:(本建筑物的灯光统一使用荧光灯)Q=n1n2NX-T W (3.8) 式中 N照明灯具所需功率W n1镇流器消耗功率系数,当明装荧光灯的镇流器装在空调房间时,取n1=1.2;当暗装荧光灯镇流器装设在顶棚内时,可取n1=1.0; n2灯罩隔热系数,当荧光灯上部穿有小孔,可利用自然通风散热于顶棚内时,取n2=0.50.6;而荧光灯罩无通风孔时,则视顶棚内无通风情况,取n2=0.60.8;T开灯时刻,h-T从开灯时刻到计算时刻的时间,h;X-T-T时间照明散热的冷负荷系数;则:灯光照明散热形成的冷负荷Q10为表3-20 由灯光散热造成的冷负荷Q11工作后小时数-Tn1n2NX-T冷负荷Q10210.51272.40.61388.0820410.51272.40.74470.7880610.51272.40.21133.6020810.51272.40.26165.41201010.51272.40.30190.8600(3) 设备散热形成的冷负荷设备散热形成的冷负荷可按下式计算:Q=QX-T W (3.9)式中 Q设备的实际散热量,W; T设备投入使用的时间,h; -T从设备投入使用的时刻到计算时刻的时间,h;X-T-T时间设备散热的冷负荷系数,见附表12。电热和电动设备实际散热量的计算方法如下:当工艺设备在室内,而电动机不在室内时,Q=1000n1n2n3N W (3.10)式中 N设备的总安装功率W; n1利用系数(安装系数),即电动机最大实耗功率与安装功率之比,一般为0.70.9; n2同时使用系数,即同时使用的安装功率与总安装功率之比,一般为0.50.8; n3负荷系数,反映平均负荷达到设计负荷的程度,一般为0.5;则:设备散热形成的冷负荷Q11为表3-21 由设备、器具散热造成的冷负荷Q11使用后小时数-Tn1n2n3NX-T冷负荷Q1120.80.60.5636.20.75114.516040.80.60.5636.20.83126.731060.80.60.5636.20.1319.849480.80.60.5636.20.1624.4301100.80.60.5636.20.1929.0107(4)总冷负荷汇总表表3-22 人体、照明、设备负荷汇总表工作后小时数-T人体照明设备冷负荷Q7显热负荷潜热负荷2327.936392.448388.082114.5161222.9824374.784448.512470.788126.7311420.815674.956889.7024133.60219.8494318.1106898.3808117.7344165.41224.4301405.957310107.7504128.9472190.8629.0107456.56833.3 建筑物制冷系统总冷负荷建筑物制冷系统总冷负荷应包括:(1)根据各房间不同使用时间、空调系统的不同类型和调节方式,按照各表3-23 房间逐时冷负荷计算得到的综合最大值围护结构负荷汇总外窗辐射负荷汇总人体、照明、设备负荷汇总冷负荷Q7负荷综合最大值805.2168152.96691420.8152378.98873.4 建筑物一层湿负荷(以所取一层大办公室为例)空调房间内的散湿量有人体散热量、敞开水面蒸发散湿量等,可从工艺提供的资料进行计算。3.4.1 人体散湿量W=0.001nng kg/h (3.11)式中 g成年男子的小时散湿量;见附表9 n室内总人数 n群集系数则:人体散湿量 W1=0.00180.96109=0.8371 kg/h3.4.2 敞开水表面蒸发散湿量W=F kg/h (3.12)式中 单位水面蒸发量;见附表14 F蒸发表面积;(按办公室每人一杯水,杯子面积取0.031)则:敞开水面蒸发散湿量 W2=0.02580.031=0.0062 kg/h建筑物总湿负荷汇总表3-24 总湿负荷汇总人体散湿量kg/h敞开水表面蒸发散失量kg/h总湿负荷kg/h湿负荷综合最大值0.83710.00620.84333.5 建筑物一层热负荷(以所取一层大办公室为例)本建筑物采用市政燃气供暖,计算方法如下采暖热负荷的内容包括基本耗热量、冷风渗透耗热量与附加耗热量,基本耗热量是按照显热负荷计算的。3.5.1 基本耗热量建筑围护结构的基本耗热量主要包括墙、门、窗、屋面和地面传热。计算公式如下:Qj=KF(ti-to) (3.13)式中 Qj建筑围护结构的基本耗热量,W; F围护结构的面积,; K围护结构的传热系数,W/(); ti冬季室内空气计算温度,; to冬季室外空气设计计算温度,; a围护结构的温差修正系数。由气象资料和室内设计参数可知,ti=18,to=-5。注:1.围护结构两侧温差大于5时,应计算维护结构的传热量。2.在围护结构的耗热量的基础上进行修正和附加。1)朝向修正率:北、东北、西北、,取010%;东西,取-5%;东南、西南-105-15%;南,取-15%-30%。2)风力附加率:建筑物在不避风的高地、河边等旷野地点,其垂直的外围护结构上应附5%10%。3)外门附加:一般开启的外门,一道门附加65n%,有门帘的两道门附加80n%,其中n为外门所在层的层数;对频繁开启的外门(如办公室、商店等),应乘以1.52.0的系数,但附加率最大不大于500%。4)高度附加:当房间高度大于4m时(楼梯间除外),按房间总耗热量,每超过1m附加2%但附加率最大不大于15%。5)间歇采暖附加:上述计算方法计算出的热负荷是针对连续供热条件下进行的,房间温度全日保证规定的温度。但对间歇采暖的建筑,热负荷将附加,一方面室内温度在全天内不均匀,部分采暖时间内室内空气温度高于设计值;另一方面房间需尽快达到正常使用温度。间歇采暖的负荷附加量是与采暖时间及围护结构的蓄热特性有关。由以上综合考虑,没有风力附加和间歇采暖附加。则:由公式和有关参数可得,采暖办公室围护结构的基本耗热量为表3-25 一层把大办公室围护结构基本耗热量KFtitoti-toQj朝向修正朝向附加外门附加修正外门附加Qz北外墙0.4818.5418-523204.710%20.500225.152北外窗2.696.6618-523412.110%41.200453.264东外墙0.4825.218-523278.2-5%-1400264.298内门2.571.8918-523111.70065%72.6184.323地面第一地带0.482018-523220.80000220.8第二地带0.351618-523128.80000128.8第二地带0.291218-52380.04000080.43.5.2 通过门、窗缝的冷风渗透耗热量冷风渗透耗热量为:Qi=0.287aLcp(ti-to) (3.14)式中 Qi冷风渗透耗热量,W; a室外计算温度下空气的密度,kg/m; L冷风渗透空气流量,m/h; Cp干空气的定压比热,kJ/(kg)。我国采暖通风与空气调节设计规范(GB500192003)规定了三种计算方法:缝隙法、换气次数法、百分比法。对多层建筑,可通过计算不同朝向的门、缝长度以及从每米长缝隙渗入的冷空气量,确定其冷风渗透耗热量,这种方法成为缝隙法。对不同类型的门、窗,在不同风速下每米缝隙渗入的空气量L,可采用附表13的实验数据。用缝隙法计算冷风渗透耗热量时,以前方法是只计算朝冬季主导风向的门窗缝隙长度,朝主导风向背向风面的门窗缝隙不必计入。实际上,冬季中的风向是变化的,不位于主导风向
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 锅炉(承压)设备焊工协同作业考核试卷及答案
- 厨具产品的营销方案设计
- 店铺促销活动宣传方案策划
- 增加客户粘性活动方案策划
- 实体门店帮扶咨询方案
- 建筑方案设计怎么评职称
- 制作手机壳活动策划方案
- 坝体护坡施工方案设计
- 心理咨询设置方案
- 职业规划书汽车营销方案
- 收割芦苇施工方案
- 环境风险评价(共84张)课件
- 函数极限说课
- 农业经济学ppt全套教学课件
- 果蔬贮藏保鲜概论:第五章 采收与采后商品化处理(第2节 分级 Sorting)
- 弱电桥架安装及电缆敷设施工方案(PPT)
- FQFNew8.0+供应商自审表格使用手册
- 合同评审管理制度管理办法
- 人教版部编三年级上册道德与法治一课一练(含答案)
- (高清版)《建筑施工作业劳动防护用品配备及使用标准》JGJ184-2009
- 全国BIM大赛一等奖获奖项目参赛PPT(76页)
评论
0/150
提交评论