




已阅读5页,还剩42页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
持续脉搏轮廓分析及跨肺心输出量测定 Continuous Pulse Contour Analysis and Transpulmonary Cardiac Output,北京协和医院 MICU 翁利,“The basic task of the cardiorespiratory system is to distribute enough oxygen to the cells” Pflger 1872,组织灌注的决定因素,OPS image of a healthy volunteer,OPS image of unresponsive microcirculatory septic shock,Spronk PE, Ince C, Gardien MJ, et al. Nitroglycerin in septic shock after intravascular volume resuscitation. Lancet 2002;360:1395-1396,组织灌注的决定因素,血压 NBP或ABP 血流 心输出量( CO ),0,临床判断缺乏准确性: CO,0,4.5,7.0,预计CO (L/min),测定CO (L/min),Eisenberg PL, Jaffe AS, Schuster DP. Clinical evaluation compared to pulmonary artery catheterization in the hemodynamic assessment of critically ill patients. Crit Care Med 1984; 12(7): 549-553,4.5,7.0,CO的测定方法,The French Way,NiCO,CCO,LiDCO,PiCCO,Monitor,PAC,英格兰与威尔士ICU的CO监测技术,Esdaile B, Raobaikady R. Survey of cardiac output monitoring in intensive care units in England and Wales. Critical Care 2005; 9(Suppl 1): P68 (DOI 10.1186/cc3131),热稀释法CO-PAC,PAC增加患者病死率,Connors AF, Jr., Speroff T, Dawson NV, et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. Support investigators. JAMA 1996;276:889-897.,PAC为何不能改善预后,不恰当的适应症 PAC的副作用或并发症 获得数据的方法不正确 仪器定标错误, 或传感器位置错误 获得的数据不能反映血流动力学状态 错误使用数据(对数据的解读错误) 作出治疗决定前未考虑其他相关因素 CXR, 尿量, 血清白蛋白 采用的治疗措施无效或有害 无需血流动力学监测时未及时拔除PAC,Is There an Easy Alternative to This Dilemma?,PiCCO的技术原理,PiCCO技术由下列两种技术组成, 用于更有效地进行血流动力和容量治疗, 使大多数病人不必使用肺动脉导管:,Central venous catheter,Injectate temperature sensor housing PV4046,Arterial thermodilution catheter,Injectate temperature sensor cable PC80109,PULSION disposable pressure transducer PV8115,PCCI,AP,13.03 16.28 TB37.0,AP 140 117 92 (CVP) 5 SVRI 2762 PC CI 3.24 HR 78 SVI 42 SVV 5% dPmx 1140 (GEDI) 625,DPT Monitor cable PMK-206,Interface cable PC80150,Connection cable to bedside monitor PMK - XXX,AUX adapter cable PC81200,心输出量的测定: 经肺热稀释技术,热稀释法测定CO: TPTD vs. PAC,CO(PAC) vs CO(TPTD),Sakka SG, Reinhart K, Meier-Hellmann A. Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients. Intensive Care Med 1999;25:843-846.,Bland-Altman Mean Bias=0.68L/min SD=0.62L/min,+2SD,-2SD,Mean Bias,CO(PAC) vs CO(TPTD),Sakka SG, Reinhart K, Wegscheider K, et al. Is the placement of a pulmonary artery catheter still justified solely for the measurement of cardiac output? J Cardiothorac Vasc Anesth 2000;14:119-124.,“For the measurement of CO alone, a PAC seems no longer justified because CO can be obtained with comparable accuracy from transpulmonary thermodilution”,PiCCO的技术原理,PiCCO技术由下列两种技术组成, 用于更有效地进行血流动力和容量治疗, 使大多数病人不必使用肺动脉导管:,连续心输出量测定: PCCO,压力曲线下面积,压力曲线型状,动脉顺应性参数,心率,与病人有关的校正因子,t s,P mm Hg,PCCO is displayed as last 12s mean,PCCO与PAC比较,目的: 比较PiCCO的PCCO与PAC测定CO的相关性 方法: 心脏外科术后患者19名 同时放置PAC及PiCCO 观察3Hr 共228组数据,Zollner C, Haller M, Weis M, et al. Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery. J Cardiothorac Vasc Anesth 2000;14:125-129.,PCCO与PAC比较,Zollner C, Haller M, Weis M, et al. Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery. J Cardiothorac Vasc Anesth 2000;14:125-129.,PCCO与PAC比较,Zollner C, Haller M, Weis M, et al. Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery. J Cardiothorac Vasc Anesth 2000;14:125-129.,PCCO 可靠性-sepsis,目的: 评价在感染性休克的情况下PCCO的可靠性 方法: 17只感染性休克的猪,3只正常对照。 同时联接2台PiCCO 1台PiCCO定期校正(1次/小时),1台不校正。 比较2台PiCCO所测CO的差别。,Schuerholz T, Meyer MC, Friedrich L, et al. Reliability of continuous cardiac output determination by pulse-contour analysis in porcine septic shock. Acta Anaesthesiol Scand 2006;50:407-413.,PCCO 可靠性,(A)感染性休克前,(B)感染性休克3Hr后,Schuerholz T, Meyer MC, Friedrich L, et al. Reliability of continuous cardiac output determination by pulse-contour analysis in porcine septic shock. Acta Anaesthesiol Scand 2006;50:407-413.,PCCO 可靠性,(C)感染性休克5hr后,(D)感染性休克9hr后,Schuerholz T, Meyer MC, Friedrich L, et al. Reliability of continuous cardiac output determination by pulse-contour analysis in porcine septic shock. Acta Anaesthesiol Scand 2006;50:407-413.,PCCO 可靠性,“we demonstrated that continuous CO determination by pulse-contour analysis is a reliable method to assess CO up to 5 h without recalibration in porcine septic shock. ”,Schuerholz T, Meyer MC, Friedrich L, et al. Reliability of continuous cardiac output determination by pulse-contour analysis in porcine septic shock. Acta Anaesthesiol Scand 2006;50:407-413.,如何判断PCCO 可靠性?,Linton NW, Linton RA. Is comparison of changes in cardiac output, assessed by different methods, better than only comparing cardiac output to the reference method? Br J Anaesth 2002;89:336-337; author reply 337-339.,绝对值,改变值,如何判断PCCO 可靠性?,“PCO methods are designed to track changes in CO. Therefore only changes in CO should be pooled from different patients.”,Linton NW, Linton RA. Is comparison of changes in cardiac output, assessed by different methods, better than only comparing cardiac output to the reference method? Br J Anaesth 2002;89:336-337; author reply 337-339.,PCCO vs TPTD相关性及影响因素,目的:PiCCO持续监测心输出量(PCCO)与跨肺心输出量(TPTD)相关性及影响因素。 方法: 北京协和医院MICU 2006/12/102007/10/8 34名危重病患者(17男17女,平均7313岁) 261次测定, TPTD测定值=3次测量均值(10%) 平均每名患者7.76.5次 比较PCCO与TPTD,PCCO vs TPTD,方法:,TPTD1,TPTD2,PCCO,PCCO=(PCCO-TPTD1)/TPTD1 TPTD=(TPTD2-TPTD1)/TPTD1,time,PCCO vs TPTD,y = 0.2121 + 0.9380 x R2 =0.71 P0.0001,PCCO vs TPTD,热稀释法测定CO方法学误差,热稀释法测定CO的误差-方法学,Stetz CW, Miller RG, Kelly GE, et al. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis 1982;126:1001-1004.,SEM%=(Standard error of mean CO)/average CO,热稀释法测定CO的误差-方法学,评价CO测量的可重复性 2SEM (Standard error of mean CO) = 95% CI of CO (测定值) 综合考虑各种因素后,大于3SEM 则表示两次测定值之差有临床意义。 例如: 1次CO测定值=3次测量平均值 SEM=5, CO1=4.2L/min, CO2=3.8L/min 3SEM%=15%, CO(1+2)/24L/min CO1-CO2=0.4 15%CO(1+2)/20.6 CO2与CO1的差别无临床意义,Stetz CW, Miller RG, Kelly GE, et al. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis 1982;126:1001-1004.,热稀释法测定CO的误差-方法学,Stetz CW, Miller RG, Ke
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 黑龙江省鸡西市名校2026届九上化学期中学业质量监测模拟试题含解析
- 低保特困政策解读
- 公司文员年终工作总结
- 工程师转正工作总结
- 2026届吉林省吉林市第十区四校联考九年级化学第一学期期中复习检测试题含解析
- 2026届安徽省宿州市埇桥集团学校九年级化学第一学期期中经典试题含解析
- 江苏省苏州市区2026届九上化学期中考试试题含解析
- 2025年山东省日照市东港区北京路中学八年级中考三模生物试题(含答案)
- 2026届贵州省贵阳市白云区化学九上期中综合测试模拟试题含解析
- 2026届安徽省砀山县化学九年级第一学期期中达标检测模拟试题含解析
- 污水处理站运行记录台账范本
- 天坛建筑结构讲解
- 兼顾电网脆弱性与经济性的PMU配置策略深度剖析
- 新提拔科级干部廉政知识考试试题及答案(二)
- 律所分所管理办法
- GB/T 8165-2025不锈钢复合钢板和钢带
- 氧疗实施中的安全监测与护理
- 2024年江苏省连云港市辅警协警笔试笔试模拟考试(含答案)
- 2024年北京大兴区招聘社区工作者真题
- 清运合同协议书模板模板
- 企业知识管理培训课件
评论
0/150
提交评论