全文预览已结束
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Observations of Emission Spectra Primary Purpose: To determine Rydbergs constant. Secondary Purposes: Compare Helium spectrum with that of Hydrogen. Determine 2p level splitting in Helium. Determine wavelength of brightest lines in Mercury and Sodium spectra and determine which energy level transitions produced these lines. Observe various emission spectra.Warnings: Do not point fiber optics probe at very bright sources. Keep blue plastic cover on probe when not in use. Do not point fiber optics probe directly at laser. Spectrum tubes will be hot. Turn off power and use handkerchief or wash rag to hold tube when removing tube.Note to Instructor: This experiment requires a computer that has the Red Tide spectrometer software installed. If not already done, software must be installed before attaching hardware.Procedure Setup1. Connect the fiber optics cable to the Red Tide Spectrometer. Connect spectrometer to computer. Turn on computer and log in. If the computer is not on the Auburn domain use the Physics Lab User account. If you do not know the password for this account, see the lab administrator.2. Start the Spectra Suite software. A picture of the Red Tide spectrometer should be on the left side and a red line running across the graph area with probe cover off. Take Data3. Put a Hydrogen tube in the power supply clips. Put power supply vertically. Using a rod and clamps place the end of the fiber optic cable about 6 inches from the spectrum tube. You may want to turn off the room lights or place a box around the tube and fiber optic cable to limit room light. Some of the lines are weak. Turn on tube power supply and adjust probe position so highest peak is near top of graph area. Get the wavelengths of the tallest peaks by putting mouse on the peak and clicking. The wavelength in nanometers is in a box along the bottom of the display. Adjust the position of the probe so you have wavelengths for 4 strongest lines in the visible part of the spectrum. Print the spectrum. 4. If the Hydrogen tube is new there will be 2 lines in the infrared region between 700-900 nm. Record wavelengths and use Internet to identify. If the lines are not present skip this step.5. Turn off the power supply and replace the Hydrogen tube (tube will be hot) with a Helium tube. Observe and print the spectrum. Adjust the probe positions as needed to obtain wavelength of at least 10 lines between 400-800 nm.6. Turn off the power supply and replace the Helium tube (tube will be hot) with a Mercury tube. Obtain wavelength of blue, green and yellow lines. Print the spectrum. See if the yellow line can be split by using zoom feature. Try to determine the wavelength of a weak line between 490 & 500 nm. Observe spectrum of fluorescent light. Can the Mercury lines be detected in the newer low mercury type fluorescent lights? 7. Observe and print the Sodium spectrum. Use the Red Tide display magnification to see if you can separate the yellow line into two lines. 8. When finished turn off emission tube and sodium power supplies.9. As time permits obtain the following spectra.10. Obtain spectrum of clear light bulb. Estimate the temperature of the filament from the peak wavelength assuming it can be treated as a blackbody.11. Obtain the spectrum of a laser (green if available, if not use red). Shine the laser at a white piece of paper and point probe at reflection.12. If a blue-violet laser and an orange piece of paper are available see what happens when you shine blue laser beam on orange paper. Get spectrum of reflected light from orange paper and white paper. If a blue-violet laser is available but not orange paper just get spectrum of light reflected from white paper.13. Observe spectra produced by the Calibration Source LEDs one by one. Determine wavelengths. To save paper turn on all LEDs at the same time and print spectrum. 14. Which (step 10-13) produce continuous spectra, line spectra or a combination?15. When finished put cover on probe tip. Turn off computer when through for the day. Turn off and unplug lasers and spectrum tube power supply. When finished with experiment unplug Red Tide spectrometer from computer. Analysis of Hydrogen Spectrum16. Look up the index of refraction for air and convert wavelengths to vacuum values and in meters not nm.17. Use the formula below and some trial and error to find the value of the quantum number m for each wavelength. For visible light n=2. Determine the value of R. If you have the correct values of m the R values will be the same (within measurement uncertainty).18. Compute average R value and compare to “book value”. For the “book value” use the reduced mass value of R not the value that treats mass of nucleus as infinite.19. How much would the wavelength differ if you were looking at the Deuterium spectrum? Multiple the infinite mass value of R for Hydrogen by the reduced mass correction for Deuterium to get R for Deuterium. For one of the lines compute the wavelength the line would have in the Deuterium spectrum. Would the difference between the H and D lines be visible with device you are using? Analysis of Helium, Mercury & Sodium Spectra20. In the row of blanks at top put your measured values of H wavelengths starting with the longest. In the vertical blanks enter your wavelength for the 4 numbered lines on the graph attached starting with longest wavelength. Convert all the wavelengths in the table below to energy in ev. The energy of the transitions due to the outer (valence) electron will be close to that of the Hydrogen electron with the same quantum numbers due to the inner electron “cancelling” one of the positive charges in the nucleus. The 2p energy level will differ some between H and He. Fill in the blanks on the diagonal with the energy difference between the wavelengths. It should be close to the same number but may differ due to uncertainty of wavelength measurements. There is another energy split of the 2p level that is only -0.03 ev. Compute the energy difference between the two levels and compare to “book value” of the1s2p level splitting in He. To get “book value” obtain the energy for the two levels from NIS
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- GB/T 8151.5-2026锌精矿化学分析方法第5部分:铅、铜、镉、钴含量的测定火焰原子吸收光谱法
- 汕头大学医学院第二附属医院常年招聘高层次人才笔试备考题库与答案解析
- 2026年中国核工业二三建设有限公司招聘789人笔试备考题库与答案解析
- 2026广西防城港市融媒体中心招聘编外人员3人笔试备考题库与答案解析
- 2026年宣城经开区投资控股集团有限公司年公开招聘2名工作人员笔试备考题库与答案解析
- 2026烟台莱州湾区海洋投资有限公司所属子公司招聘笔试备考题库与答案解析
- 2026上海交通大学医学院附属瑞金医院医疗、科研、医技岗位招聘笔试备考题库与答案解析
- 2026年甘肃省天水市奋斗巷幼儿园招聘笔试备考题库与答案解析
- 2027国网上海市电力公司第一批招聘(335人)笔试模拟试题及答案解析
- 2026湖南岳阳市屈原管理区残疾人联合会编外人员招聘笔试模拟试题及答案解析
- 2026年教育原理模拟试卷(含答案)
- 慢性阻塞性肺疾病诊疗指南(2026版)
- 2026年大商所行政公司校园招聘考试参考试题及答案解析
- 2026中国新能源发电设备智能化运维市场机会与挑战报告
- 学校运动场改造项目初步设计
- 2026年消防宣传月消防知识竞赛题库(附答案)
- 儿童化妆课课件
- 2026年中卫市高新技术产业开发集团有限公司公开招聘工作人员笔试模拟试题及答案解析
- 2026年辐射安全与防护考试题库(附答案)
- 2026新教材苏教版科学五年级上册单元知识点
- 2026年广东省春季高考(学考)语文真题(含解析)
评论
0/150
提交评论