UDC GB National Standard of the Peoples Republic of China P GB 50151- 92 低倍数泡沫灭火系统设计规范低倍数泡沫灭火系统设计规范 Code of Design for Low Expansion Foam Extinguishing System Issued on: Jan. 10, 1992 Implemented as of: July 01, 1992 Jointly Issued by: State Bureau of Technological Supervision Ministry of Construction of PRC National Standard of the Peoples Republic of China Code of Design for Low Expansion Foam Extinguishing System GB 50151- 92 Compiled and Prepared by: Ministry of Public Security of PRC Approved by: Ministry of Construction of PRC Implemented as of: July 01, 1992 Notice on the issuance of the national standard “Code of Design for Low Expansion Foam Extinguishing System” JB 1992 No.30 In compliance with the requests of Document No. 2630 Jizong 1986 of State Planning Commission, the “Code of Design for Low Expansion Foam Extinguishing System” jointly compiled and prepared by the Ministry of Public Security and other departments concerned has been checked up jointly by the departments concerned. It is approved that GB 50151- 92 “Code of Design for Low Expansion Foam Extinguishing System” be a national standard and take effect as of July 1, 1992. The Code is controlled by the Ministry of Public Security, interpreted by Tianjin Fire Fighting Scientific Research Institute of the Ministry of Public Security and published and distributed by the Standard Quota Research Institute of the Ministry of Construction. Ministry of Construction of PRC Jan. 10, 1992 Explanatory Notes to Compilation and Preparation The Code is prepared jointly by Tianjin Fire Fighting Scientific Research Institute of the Ministry of Public Security and the following units SINOPEC Beijing Design Institute, Luoyang Petrochemical Engineering Corporation, Daqing Petroleum Exploration Design and Research Institute of China Petroleum Natural Gas Corporation and Fire Brigade of Tianjin Public Security Bureau in compliance with Document No. 2630 Jizhong 1986 of the State Planning commission. During compilation and preparation, the draftsmen of the Code made extensive investigations and studies on the current status of the scientific research, design and application of low expansion foam extinguishing system in our country in accordance with relevant national policies and the policy of “Putting Prevention First and Combining Prevention with Fighting” regarding fire fighting work, tested and verified the supply strength of foam solution taking into consideration all previous major tests carried out in China and Sino- Japan Petroleum Fire Fighting Test, especially the availability of ring- pump type proportioning process under self- dumping condition. The Code is checked up and finalized by the departments concerned assimilating the current results of scientific research and engineering practices, referring to the code and information on the design, installation and acceptance of low expansion foam extinguishing system from the US, Japan, Germany, Russian and ISO and soliciting the opinions from scientific and research institutes, design institutes and higher education colleges and universities subordinated to some provinces and cities, departments and commissions concerned as well as large- sized petrochemical enterprises and public security supervision authorities for fire fighting. The Code is divided into four chapters and two appendices, which mainly consist of General Principle, Selection of Foam Liquid and Sizing of the System, System Design, System Assembly, etc. Since the Code is compiled and prepared for the first time, all units are requested to pay attention to the collection of information and summing- up of experience during the execution. If something is found to be modified and supplemented, please mail your comments and relevant materials to Tianjin Fire Fighting Scientific and Research Institute of the Ministry of Public Security (Address: Liqizhuang, Tianjin, Zip Code: 300381) for future reference and modification. Ministry of Public Security of PRC October, 1991 CONTANT Chapter I General Provisions .6 Chapter II Selection of Foam Liquid and Sizing of the System.6 Section I Selection, Storage and Formulation of Foam Solution.6 Section II Sizing of the System6 Chapter III System Design.7 Section I General Provisions of Design for Foam Extinguishing System for Tank Farm7 Section II Design for Injection Foam Extinguishing System for Tank Farm.7 Section III Design for Submerged Injection Foam Extinguishing System for Tank Farm.10 Section IV Foam Spraying System12 Section V Foam Pump Station .12 Chapter IV System Assembly 13 Section I General Provisions13 Section II Foam Pump and Foam Proportioner13 Section III Foam Liquid Storage Vessel.14 Section IV Foam Generator14 Section V Valve and Fitting14 Appendix I Terminology15 Appendix II Notes of Wording16 Additional Explanatory Notes:17 Chapter I General Provisions Article 1.0.1 The Code is prepared to design properly the low expansion air foam extinguishing system (hereinafter referred as foam extinguishing system), minimize fire losses and guarantee the safety of personnel and property. Article 1.0.2 The design for foam extinguishing system shall comply with the relevant national principles and policies, be safe and reliable, advanced in technology, rational in economy and easy in management. Article 1.0.3 The Code is applicable to the design for foam extinguishing system for the process, storage , handling and application of Class A (except liquefied hydrocarbons), B and C liquids. The Code is not applicable to the design for foam extinguishing system for ships and offshore oil platforms. Article. 1.0.4 In addition to the specifications of the Code, the design for foam extinguishing system shall conform to the relevant standards and codes in force in the country. Chapter II Selection of Foam Liquid and Sizing of the System Section I Selection, Storage and Formulation of Foam Solution Article 2.1.1 For non- aqueous liquids of Class A, B and C, it is recommended that protein foam liquid, fluoro- protein foam liquid or aqueous film- forming foam liquid shall be selected if injection foam extinguishing system is used while fluoro- protein foam liquid or aqueous film- forming liquid shall be selected if submerged injection foam extinguishing system is used. Article 2.1.2 Alcohol- resistant foam liquid shall be used for aqueous liquids of Class A, B and C. Article 2.1.3 Foam liquids shall be stored at a temperature of 0- 40 0C and in a well- ventilated dry room or shed. Article 2.1.4 The formulation of foam liquid into foam solution shall meet the following requirements: 1. Fresh water or sea water may be used to formulate protein, fluoro- protein and alcohol- resistant fluoro- protein foam liquid into foam solution; 2. Fresh water shall be used to formulate gel- type and metallic soap type foam liquid into foam solution. 3. Water that has an impact on the extinguishing performance of the foam is forbidden to be used to formulate all kinds of foam liquid into foam solution. 4. It is recommended that the temperature of the water used to formulate foam liquid into foam solution be 4- 35 0C. Section II Sizing of the System Article 2.2.1 The system shall be sized according to the compound factors such as the scale of the protected object, fire hazard, general arrangement, difficulty of fire suppression and set up of fire station. Article 2.2.2 It is recommended that fixed foam extinguishing system be selected for one of the following applications 1. Independent tank farm of non- aqueous liquids of Class A, B and C with a total storage capacity 500 m3; 2. Vertical tank farm of aqueous liquids of Class A, B and C with a total storage capacity 200 m3; 3. Tank farm of non- aqueous liquids of Class A, B and C, which is affiliated to enterprises with inadequate mechanical fire fighting facilities. Article 2.2.3 It is recommended that semi- fixed foam extinguishing system be used for one of the following applications: 1. Tank farm of liquids of Class A, B and C affiliated to enterprises with strong mechanical fire fighting facilities; 2. Applications with potential of fire hazard in petrochemical production area. Article 2.2.4 It is recommended that portable foam extinguishing system be used for one of the following applications: 1. Ground vertical tank of non- aqueous liquids of Class A, B and C with a total storage capacity 500 m3, single tank capacity 200 m3 and the height of tank wall 7m; 2. Ground vertical tank of aqueous liquids of Class A, B and C with a total storage capacity 200 m3, single tank capacity 100 m3 and the height of tank wall 5m; 3. Horizontal tanks; 4. The areas easy to leak in the loading place of Class A, B and C liquids. Chapter III System Design Section I General provisionsof Design for Foam Extinguishing system for Tank Farm Article 3.1.1 The design for foam extinguishing system for tank farm and the foam solution quantity shall meet the requirements of the sum of solution consumption necessary for suppressing the fire of single tank with maximum solution consumption and solution consumption necessary for the auxiliary foam nozzles used to suppress the spreading fire of the tank. Article 3.1.2 The amount necessary to fill up the pipes shall be included in the total storage quantity of foam liquid for tank farm in addition to the quantity calculated with the specified supply strength, number of nozzles and continuous supply duration. Article 3.1.3 If fixed foam extinguishing system is used, portable foam extinguishing devices such as foam hook pipe, foam nozzle and foam fire vehicle shall be provided in addition to fixed foam extinguishing devices. Article 3.1.4 The number of foam nozzles necessary for suppressing the spreading fire of liquids of Class A, B and C shall be determined with the diameter of the tank with maximum consumption of foam solution, the number and continuous supply duration shall not be less than the specifications in Table 3.1.4. Number of foam nozzles and continuous supply duration Table 3.1.4 Diameter of Tank (m) Number of PQ8 Nozzles Provided (piece) Continuous Supply Duration (min) 33 3 30 Section II Design for Injection Foam Extinguishing System for Tank Farm Article 3.2.1 The firing area of injection foam extinguishing system for fixed roof tank shall be calculated with the cross section area of tank. The supply strength and continuous supply duration of foam solution shall conform to the following specifications: I. For non- aqueous liquids of Class A, B and C, the strength and duration shall not be less than those in Table 3.2.1- 1. Supply Strength and Continuous Supply Duration Table 3.2.1- 1 Supply Strength (L/min.m2) Class of liquid Fixed and semi- fixed type Portable type Continuous supply duration (min) Class A II. The distance from foam weir plate to the tank wall shall be 1.0m. If mechanical seal is used, the height of the weir plate shall be 0.25m; If soft seal is used, the height of the weir plate shall be 0.9m. Water discharge holes shall be provided at the lowest part of the weir plate, the opening area shall be calculated based on the assumption that two 12mm x 8mm rectangular openings are provided for every square meter of annular area. Supply Strength of Foam Solution, Protection Perimeter of Foam Generator and Continuous Supply Duration Table 3.2.2 Foam Generator Supply Strength Protection Perimeter Continuous Duration Type Flow of Solution (L/min) (L/min.m2) (m) (min) PC4 240 12.5 18 30 PC8 480 12.5 36 30 Article 3.2.3 The design for foam extinguishing system for inner floating roof tank shall conform to the following specifications: I. For shallow- pan type inner floating roof tanks and the inner floating roof tanks with the floating pan made of fusible material, the firing area, supply strength and continuous supply duration shall conform to the specifications in Article 3.2.1 of the Code. III. For single- and double- pan type inner floating roof tanks, the firing area, supply strength and continuous supply duration of foam solution shall conform to the specifications of item 1 of Article 3.2.2 of the Code, the distance from foam weir plate to tank wall shall be 0.55m, and the height of the plate shall be 0.5m. Article 3.2.4 The foam generator for injection foam extinguishing system shall be provided according to the following specifications: I. For fixed roof tank, inner floating roof tank of shallow- pan type and with the floating roof made of fusible material, the type and number of foam generator shall be determined by the flow of foam solution calculated, and the number provided shall not be less than those specified in Table 3.2.4. Number of Foam Generator Provided Table 3.2.4 Diameter of Tank (m) Number of Foam Generator Provided (set) 10 1 10- 20 2 21- 25 3 26- 35 4 II. For outer floating roof tanks and inner floating roof tanks of single and double disc type, the type and number of foam generator shall be determined according to the specification in Article 3.2.2; III. The inlet pressure of foam generator shall be 0.30.6 Mpa, the corresponding flow of foam solution shall be calculated with the following equation: Where qFlow of foam solution (L/s); K1Flow characteristic coefficient of foam generator; p - - Inlet pressure of foam generator (Mpa). Article 3.2.5 The routing of foam solution pipe on the tank shall conform to the following specifications: I. For fixed roof tank, inner floating roof tank of shallow- pan type or with the floating pan made of fusible material, each foam generator shall be routed out of the fire- proof embankment with separate solution pipe. II. For outer floating roof tank and inner floating roof tank of single and double disc type, every two generator shall be routed with one common pipe at the bottom of the vertical pipe of foam solution out of the fire- proof embankment. When three or more generators share one pipe at the bottom end of the vertical pipe of foam solution being routed out of the fire- proof embankment, control valve shall be provided in each vertical pipe of foam solution. The solution flow necessary for each foam solution pipe of fixed foam extinguishing being routed out of the fire- proof embankment shall not be greater than the supply amount of one fire vehicle. III. The vertical pipe of foam solution connecting foam generators shall be fixed with clips on the tank wall, with a clearance 3m. Rust cleaner shall be provided at the bottom end of the vertical pipe of foam solution. The vertical pipe of foam solution shall be connected to the horizontal pipe with metal hose. It is allowed that outer floating roof tank be not provided with metal hose; IV. The ladder and platform for outer floating roof tank shall be provided the pipe connection with cover, )4 . 2 . 3( 1 pkq = the connection is routed along the tank wall to 0.7m above the ground or out of the fire- proof embankment, and corresponding connections shall be provided. Article 3.2.6 The routing of foam solution pipe within the fire proof embankment shall conform to the following specifications: I. The horizontal pipe of foam solution shall be routed on pipe stand or support, however not fixed with them. II. The pipe of foam solution shall be inclined with 30% slope to the fire- proof embankment. Article 3.2.7 The routing of foam solution pipe out of fire- proof embankment shall conform to the following specifications: I. It is recommended that hydrants be provided in the foam solution pipe, the number shall be determined according to the number of nozzles and the radius of protection specified in Article 3.1.4 of the Code; II. The foam solution pipe shall be inclined with 2% slope to vent valve, the control valve in the pipe shall be located out of the fire- proof embankment and be provided with clear mark; III. High vents shall be provided in foam solution pipe. Article 3.2.8 The design flow for foam solution pipe shall be 3m/s, the hydraulic calculations shall be done based on the national standard in force “Design Code of Auto Spraying fire extinguishing system “. Section III Design for Submerged Injection Foam Extinguishing System for Tank Farm Article 3.3.1 The submerged injection foam extinguishing system shall not be adopted for tanks of aqueous liquids of Class A, B and C, neither should it be used for outer floating and inner floating roof tanks. Article 3.3.2 For ground fixed roof tanks, when submerged injection foam extinguishing system and fluoro- protein foam liquid is used, the following specifications shall be satisfied: I. The supply strength of foam solution shall 6L/min.m2, foam expansion of 3 shall be used; If the storage temperature exceeds 50 0C or the viscosity is greater than 40mm2/s, the supply strength of foam solution shall be determined by tests; II. The continuous supply duration of foam solution shall be 30 min; III. The speed of foam entering into oil shall be 3m/s; IV. The injection nozzle shall be inclined upward with an inclined angle of 450, the length of injection pipe intruding into the tank shall be 10 times the diameter of injection pipe. If only one injection nozzle is available, it shall be located at the center of the tank; if more than one nozzle is provided, they shall be located evenly with an approximate equal flow for each injection nozzle; V. Foam injection nozzle shall be installed above the water layer of the tank. The number of injection nozzle provided shall not be less than that specified in Table 3.3.2. Number of injection nozzle provided Table 3.3.2 Diameter of Tank (m) Number of Injection Nozzle (piece) 33 3 Article 3.3.3 The high back- pressure foam generator for submerged injection foam extinguishing syste
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年事业单位工勤技能-河北-河北医技工一级(高级技师)历年参考题库含答案解析
- 2025年事业单位工勤技能-江苏-江苏不动产测绘员四级(中级工)历年参考题库含答案解析(5套)
- 2025年事业单位工勤技能-广西-广西收银员四级(中级工)历年参考题库典型考点含答案解析
- 2025年事业单位工勤技能-广西-广西图书资料员五级(初级工)历年参考题库典型考点含答案解析
- 2025年事业单位工勤技能-广东-广东铸造工二级(技师)历年参考题库含答案解析
- 2025年事业单位工勤技能-广东-广东汽车修理工(技师/高级技师)历年参考题库典型考点含答案解析
- 2025年事业单位工勤技能-广东-广东土建施工人员一级(高级技师)历年参考题库含答案解析
- 2020-2025年证券从业之金融市场基础知识自测模拟预测题库(名校卷)
- 2025年职业技能鉴定-铁路职业技能鉴定-铁路职业技能鉴定(铁路车站值班员)高级历年参考题库含答案解析(5套)
- 2025年职业技能鉴定-邮政储汇业务员-邮政储汇业务员高级历年参考题库含答案解析(5套)
- 2025年贵州贵阳市水务环境集团有限公司招聘27人笔试参考题库附带答案详解(10套)
- 2025届中国南方航空“明珠优才管培生”全球招聘30人笔试参考题库附带答案详解(10套)
- 原发性系统性淀粉样变性的护理措施课件
- 《阿房宫赋》课件 统编版高中语文必修下册
- DB54T 0498.3-2025 生态系统碳汇计量与监测体系建设技术规范 第3部分:湿地碳汇计量与监测方法
- 桥小脑角肿瘤护理查房
- 2025小学教师招聘考试试题及答案
- 2025年纪律作风测试题及答案
- 2025江苏苏州昆山国创投资集团有限公司第一期招聘17人笔试参考题库附带答案详解版
- 新疆的历史文化课件
- 安全生产网格化管理工作实施方案
评论
0/150
提交评论