已阅读5页,还剩22页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1,CHAPTER 6,2,Bond Stick On Ball(BSOB)/Bond Ball On Stitch(BBOS)/ Tail Break,3,1.0) BOND STICK ON BALL(BSOB),1.1) Description This bonding process is specially developed by ASM to handle multi-die(MCM) bonding application. In the conventional approach, if one is trying to connect the gold wire from one die to the another, a capillary mark of second bond will be evident on top of the die which may damage the die. The BSOB process will solve this problem by bonding a ball onto the dies surface first, followed by bonding another wire where the second bonds wedge will be landing on top of this bonded ball(figure 1).,4,Die 1,Die 2,Bond Ball,2nd Bond(wedge),Figure 1 : Bond Stick On Ball(BSOB),5,2.0) BOND BALL ON STITCH(BBOS)/ SECURITY BOND,2.1) Description This process is also known as security bond. It bonds a ball on top of the wedge of the normal connection wire.This process is mainly used to secure the second bond sticking capability.(Figure 2),Die 1,Lead,Bond Ball,2nd Bond (wedge),Figure 2 : Bond Ball On Stitch (BBOS),6,3.1) Free Air Ball (FAB 2)is aligned to the center of the bond pad on device 2.,FAB 2,3.0 STANDOFF BALL CONTROL BONDING SEQUENCE,7,3.2) Capillary descends and bonds ball to bond pad.,Device 1,Device 2,W/clamp open,Capillary,Application of 1st bond stand off ball parameter to form Ball Thickness and Ball Size,During Stand Off Bonding , SOB parameters are applied .,8,3.3) Capillary rises to loop base to clear ball.,Device 1,Device 2,W/clamp open,Capillary rises to set Loop Base,Loop Base,Contact Pt.,Loop base is the distance between the capillary tip and contact point.,Recommended setting = 2,9,3.4) Capillary move to programme ball offset. Ball offset can be programmed towards or away from the first bond. + ve towards 2nd bond - ve away 2nd bond,Device 1,Device 2,Actual Ball Offset = Setting x 10um If Ball Offset Setting = 22 Then Actual Loop Base =220um,Recommended Setting = - ve 35,10,3.5) Capillary descends and forms stitch bond on top of the ball.,Device 1,Device 2,*Ball Thickness,SOB Parameter (Stand Off Ball Parameter),Capillary descends to set Ball Thickness (Amt. Z movement above the ball height),Contact Pt.,* Ball Thickness is the distance between the capillary tip and contact point Recommended setting = 2,11,3.6) Capillary moves horizontally for a scrub distance to weaken the wire at ball neck.,Device 1,Device 2,Scrub one direction away from ball,Actual Scrub Distance = Setting x 0.8 um If Scrub Distance Setting = 10 Then Actual Scrub Distance = 8 um,Capillary move to set Scrub Distance One direction ONLY - Away from the ball,Recommended setting = 8,12,3.7) Capillary rises to tail height,Device 1,Device 2,W/clamp close,Capillary moves to set Tail Length (Amount Z movement above the bump before the wire clamp closes),Recommended setting = 35,13,3.8) Capillary rises and tears the wire, as BH ascend to Fire Level.,Device 1,Device 2,W/c close,14,15,3.10) After placing all standoff balls. The machine continue to bond wires.,2nd Bond(wedge),Device1,Device2,Device1,16,Bump ball formation for BSOB/BBOS,MOTION,BO,LB,BT,SC,Normal LB BO BT Scrub,Flat LB BO BT Scrub=0,CONE LB BO BT=LB Scrub=0,LB,BO,BT,LB,BO,The bump ball formation process is almost like bonding a normal wire, including 1st bond, looping and 2nd bond parameters.,17,4.0) PARAMETER DEFINITION IN STAND OFF BALL CONTROL MENU,4.1) Loop Base This parameter determines the loop level of the bondhead which should be sufficient to avoid the ball. Range: Loop Base 0 5 Setting : 2 4.2) Ball Offset This setting controls the distance of the table move in order to offset the capillary from the standoff ball. Negative value can be moved towards to the first bond. Positive value can be moved away from the first bond. Range: Ball Offset - 40 20 Setting : - ve 35,18,4.4) Scrub Distance This setting controls the capillary moves horizontally with a Scrub amplitude to weaken the wire at neck. It is always away from the first bond. Range: Scrub Dist 4 12 Setting : 8 4.5) Tail Length This setting controls the length of the tail where the bondhead rises to the preset height before the wire clamp is closed. Range : Tail Length 30 40 Setting : 35,4.3) Ball Thickness This parameter refer to the ball thickness which controls the level of the bondhead as it descends to the top of the ball Range: Ball Thickness 0 5 Setting : 2,19,4.6) Time Base 1/2 This setting controls the bond time applied to the standoff ball control only. Time 1 for the 1st bond and Time 2 for the 2nd bond. 4.7) Power Base 1/2 This setting controls the ultrasonic power applied to the standoff ball control only. Power 1 for the 1st bond and Time 2 for the 2nd bond. 4.8) Force Base 1/2 This setting controls the bonding force applied to the standoff ball control only. Force 1 for the 1st bond and Force 2 for the 2nd bond.,20,4.9) Standby Power 1/2 This setting controls the power activated when the bonding head reach the search level, to the moment the bond head contacts the bond surface. With the vibration, before contact take place. Bond head will clean up the pad surface and remove water vapor on the pad. This parameter used for the standoff ball control only. 4.10) Contact Time 1/2 Refer to the Contact time 1/2 definition in Bond Parameter menu. But this parameter will be affected on the Standoff ball control only.,21,4.11) Contact Power 1/2 Refer to the Contact Power 1/2 definition in Bond Parameter menu. But this parameter will be affected on the Standoff ball control only. 4.12) Contact Force 1/2 Refer to the Contact Force 1/2 definition in Bond Parameter menu. But this parameter will be affected on the Standoff ball control only.,22,Figure 4 : Standoff Ball Control Parameter Display(page 2),5.0 BSOB WIRE PARAMETERS,23,5.1) Wire Offset In -Menu This is the offset parameter that is required to ensure maximum contact area between the stitch bond and ball. It is always away from the first bond. Range: Wire Offset 10 30 Recommended setting = 25,5.2) Second Bond Search Speed This Parameter controls the impact for stitch on ball. Range: Search Speed 2 32 256 Recommended setting = 32,2nd Bond Wedge,Stand Off Ball,Capillary position during stitch bond,24,5.3) Time Base 1/2 This setting controls the bond time applied to the device. Time 1 for the 1st bond and Time 2 for the 2nd bond. 5.4) Power Base 1/2 This setting controls the ultrasonic power applied to the device. Power 1 for the 1st bond and Time 2 for the 2nd bond. 5.5) Force Base 1/2 This setting controls the bonding force applied to the device. Force 1 for
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 湖北省黄石市十校联考2026届初中物理毕业考试模拟冲刺卷含解析
- 广东省佛山禅城区七校联考2026届中考物理四模试卷含解析
- 山东省日照市岚山区2026届中考押题物理预测卷含解析
- 河北省故城县市级名校2026届中考适应性考试物理试题含解析
- 2026届安徽省南陵县联考中考猜题物理试卷含解析
- 前置胎盘孕妇饮食指导查房
- 中医护理病历的护理目标
- 中医护理便秘调养课件
- 护理质量月护理管理
- 2026年土木营建机械操作工实操题库
- 2025年山东省济南市初二学业水平地理生物会考考试试题及答案
- 2026人教版二年级数学下册期末模拟测试卷(三套含答案)可直接打印
- 2026天津大学附属小学教师招聘8人-天津大学事业编考试参考试题及答案解析
- 2026年浙江省公开遴选公务员笔试试题及答案解析(综合类)
- (2026版)《商事调解条例》课件
- 2026年事业单位考试国内核心时事政治考点梳理(附50题)
- 2026年中考语文标点符号专项训练模拟试卷(覆盖高频考点)
- 雨课堂学堂在线学堂云《人工智能时代的创新思维(北京理工)》单元测试考核答案
- 2025年07月渤海银行2025年招考审计部团队负责人笔试历年备考题库附带答案详解试卷2套
- 2026年剧本杀主持人控场题库含答案
- T/CBDA35-2019 建筑装饰装修工程施工组织设计标准
评论
0/150
提交评论