SifangManual for JFZ-30Q Switching Parallel Unit Manual BoxJFZ-30Q Switching parallel boxUnit ManualManual Compiled:Prepared by: Shi Wenhao Checked by: Bao Liyong StandardizedStandardization censor: Zhen Wei InspectedApproved by: Xu GangVersionPublishing number: V1.0Doc. CodeDocument code: 0SF.459.036(E)Issued DatePublishing date: Oct of 20052007.06Copyright owner: Beijing Sifang Automation Co., Ltd.Note: the company keeps the right to perfect the instruction. If products do not agree with the instruction at anywhere, please contact our company in time. We will provide you with corresponding service.Technical support Tel:Faxes:opyright owned by: Beijing Sifang Automation Co., LtdNote: This company reserves the right of the modification to the manual. If the product is not consistent to the manual, please contact us in time, and we will offer corresponding service to you. Technical support: phone:Fax:mportant noticepromptsThank you for using products of Beijing Sifang Automation Co., Ltd. In order to safely, correctly and efficiently use the equipment, please do pay attention to following important prompts: Thank you for using the products of the Beijing Sifang Automation Co., Ltd. In order to securely, correctly and efficiently use this unit, please notice the following important notice: 1) This instruction manual is only applicable to JFZ-30Q switching parallel boxunit. 2) Please read this manual carefully and adjust, test and operate as per the regulations in the manual. If the accompanying information is offered, please refer to the accompanying information. 3) To prevent the unit from damage, it is prohibited to hot plug various plug-inschip and contact the chips and parts component in the printing circuit board with the current. 4) Please use the qualified testing instrument and the device for test and detection. 5) If any abnormity happens to the equipment or maintenance is required, please contact service hot line of our company in time.If the unit operates abnormally or requires repair, please the contact the company by the hotline number.Table of contents1General111.1Key features of the product111.2Application scope111.3Shape dimension and installation dimension of the product222Technical condition332.1Rated parameter332.2Technical parameter332.3Environmental condition332.4Electrical insulation performance332.5Electromagnetic compatibility performance442.6Mechanical performance442.7Safety performance443JFZ-30Q switching parallel box553.1Power monitoring loop553.2Voltage switching circuit553.3General principle drawing, terminal drawing and plug-in layout drawing664Operation notice995Unpack for checking996Transfer and store997Instruction for order991 General 1.1 Key features of the productSifang switching parallel box is the suite product for the protection and control unit of the Beijing Sifang Automation Co., Ltd; meanwhile it is compatible to other protection control products and can be used as suite products at home and abroad.The requirement for integrating the voltage monitoring function is considered in the design scheme of Sifang switching parallel box, the switching parallel function is required; the voltage monitoring function is optional. 1.2 Application scopeThe naming method for Sifang series switching parallel box is as follows: JFZ 30 Q A (/*) (Region flag)Ano-voltage monitoring circuit Bwith voltage monitoring circuit Qswitching parallel box 30dual bus or single bus and single section, switching of basic type or parallel 31dual bus or single bus and single section, switching or parallel of the protection and computing voltage 32dual bus or single bus and single section, parallel and repeat of the protection and computing voltage 33single bus dual section, parallel and repeatr of the protection and computing voltage 34dual bus and four section, parallel and repeat of the protection and measuring voltage41dual bus or single bus and single section, switching or parallel of the protection, computing and measuring voltage 42dual bus or single bus and single section, parallel and repeat of the protection, computing and measuring voltage 43single bus and double section, parallel and repeat of the protection, computing and measuring voltage44dual bus and four section, parallel and repeat of the protection, computing and measuring voltageCode of Sifang relay assisted unit Sifang series switching parallel box is divided into the base switching/parallel box (JFZ-30Q), dual bus or single bus section switching/parallel box (JFZ-31Q/41Q), single bus and dual section parallel and repeat box (JFZ-32Q/42Q), single bus and double section parallel and repeat (JFZ-33Q/43Q) and double bus and four-section parallel and repeat box (JFZ-34Q/44Q). Wherein JFZ-30Q is used for the protection and measuring voltage switching of the dual bus connection line and is the basic configuration of the switching parallel box; JFZ-31Q is used for the protection and measuring voltage of the dual bus connection line, or is used for the protection and simple parallel of the measuring voltage of the single bus and single section connection line; JFZ-42Q JFZ-41Q is used for protection, measure and measured voltage switching of the dual bus connection line, or is used for the protection, computing and single parallel of the single bus and single section connection line; JFZ-32Q is used for the protection and parallel and repeat of the dual bus or single bus and single section; JFZ-42Q is used for the protection, computing and measure voltage parallel and repeat of the dual bus or single bus and single section connection line; JFZ-33Q is used for the protection, measure voltage parallel and repeat of the single bus and dual section connection line; JFZ-43Q is used for the protection, computing and measure voltage parallel and repeat of the single bus and dual section; JFZ-34Q is sued for the protection, measuring voltage parallel and repeat of the double bus and four section connection line; JFZ-44Q is used for the protection, computing, measure voltage parallel and repeat of the double bus and four section connection line. The switching/parallel box can offer the voltage-monitoring loop in the optional configuration manner and is used to monitor PT voltage; JFZ-30Q is the basic switching parallel box and does not offer the voltage monitoring function. The switching relays of all above types of switching parallel boxes can select hold or non-hold type, please mark it upon order. 1.3 Shape dimension and installation dimension of the product The enclosure adopts the new half-layer 19”/2 standard 4U enclosure and the whole back board adopts the front plug open panel. The light displays on the panel.For the installation hole drawing, refer to the hole dimension drawing of the 19”/2 standard enclosure. Hole drawingDimension drawingFigure 1 19”/2-4U standard enclosure shape and hole drawing2 Technical condition 2.1 Rated parameter1)Rated power and voltage: DC 220 V or 110 V2)Rated AC voltage: 100/V 2.2 Technical parameter 1) Allowed fluctuation range of the voltage: -20+152) Power consumption: normal state10W3) Capacity of the switching relay contact: 10A 250V AC;2500VA2.3 Environmental condition The unit can normally operate under the following environmental condition 1) Environmental temperature: -1055, the storage temperature: -2570, no excitation temperature is offered under the limit, the unit will not show the non-reversible change, after the temperature recovers, the unit should be able to normally operate. 2) Relative humidity: the maximum average relative humidity for the most humid month is 90%, the minimum average monthly temperature of this month is 25 and there is no condensation on the surface. 3) Atmosphere pressure: 80kPa110kPa (the elevation height 2km and lower)4) The risks such as fire, explosion and erosion, which threat the product safety and the actions such as shock, impact and collision beyond the regulations in the manual are prohibited at the operation site. 2.4 Electrical insulation performance 1) Media intensity The unit can resist the 2kV AC voltage (strong current loop) or 500V (weak current loop), 50Hz frequency, 1 min duration media intensity test regulated in the GB/T14598.3-1993 (eqv IEC60255-5) and no breakdown and flickering phenomena occurs. 2) Insulation resistance The testing instrument with the 500V open voltage can test the unit whose insulation value is not less than 100M and meets the regulations in the IEC60255-5:2000. 3) Impact voltage The unit can bear the impact voltage test for the standard thunder electric wave with the peak 5kV (strong current circuit) or 1kV (weak current circuit) regulated in the GB/T14598.3-1993 (eqv IEC60255-5). 2.5 Electromagnetic compatibility performance 1) Pulse group interference The unit can bear the 1MHz and 100kHz pulse group interference test regulated in the GB/T 14598.13(eqv IEC60255-22-1). (The first half-wave voltage amplitude common mode is 2.5kV, the differential mode is 1kV). 2) Static discharging interference: The product can bear the static discharge interference test (contact discharge is 6kV) regulated in the GB/T 14598.14(idt IEC60255-22-2). 3) Radiation electromagnetic interference: The unit can bear the (10V/m) radiation electromagnetic field interference test regulated in the GB/T 14598.9(idt IEC60255-22-3). 4) Fast instantaneous change interference The product can bear the IV (2kV for communication port, 4kV for other port) fast instantaneous change interference test regulated in the GB/T 14598.10(idt IEC60255-22-4). 5) Surge resistance The unit can bear the stringent grade under the 750kV environmental standard regulated by the IEC61000-4-5. 2.6 Mechanical performance1) Vibration The product can bear the I vibration response and shock resistance test regulated in the GB/T 11287(idt IEC60255-21-1). 2) Impact and collision The product can bear the I impact response and impact resistance test regulated in the GB/T 14537(idt IEC60255-21-2) and I collision test. 3) Mechanical lifecycle The non-interrupted arc of the output contact should reliably operate and can return for 105 times. 2.7 Safety performance The product meets at least IP 20 GB and class I safety 16836-shell prevention grade. 3 JFZ-30Q switching parallel box The configurations for different types of the JFZ-30Z switching parallel box are as follows: JFZ-30QNo measure voltageNo voltage monitoring:JFZ-30QA(No corresponding product)No measure voltage(No corresponding product)JFZ-30Q unit includes two groups of switching relays (1YQJ、2YQJ) and monitoring relays (1YQJF、2YQJF) and can not measure voltage switching and monitor PT voltage. Switching parallel boxFigure 2: Panel layout of JFZ-30QA switching parallel box3.1 Power monitoring loop The enclosure is connected into the power through the isolation knife switch (I bus4n0101, II bus4n0103 and KM4n0105), the corresponding bus operation indicator illuminates and the break contact of the power loss warning indicator is open. In addition, when two groups of the isolation switch assisted contact close simultaneously, the relay action is monitored, the make contact closes warning signals. The power-monitoring relay is non-hold relay and is not affected by the hold and non-hold state of the switching relay. 3.2 Voltage switching circuit The voltage switching relay is the default two groups dual-position relay, when the DC voltage disappears, the AC voltage switching relay holds, the protection voltage will not lose (if the user requires, the switching relay can be used as two groups of non-holding relay, when the DC voltage disappears, the AC voltage switching loop is open). When the product is normally used for the dual bus voltage switching, it is recommended to make the 4n0101(start 1YQJ) and 4n0104(return 2YQJ) short and connected to the isolation switch 1G assisted make contact, make the 4n0103(start 2YQJ) and 4n0102 (return 1YQJ) short and connected to the insulation switch 2G assisted make contact, connect 4n0105 to the switching negative power, the corresponding I bus of the panel operates, II bus operation indicator (green) illuminates. 1G and 2G insulation switch only uses one pair of assisted make contact. To improve the adaptability capability of the unit, the loop driver is designed by four-port input, besides the above dual bus voltage switching, it is also used for the voltage parallel function. The several recommended connection modes used for different switching/parallel condition is offered in the general principle drawing. The first group of PT secondary protection voltage is connected to 4n02014n0205, the measuring voltage is connected to 4n02064n0208; the second group of PT secondary protection voltage is connected to 4n02094n0213, the measuring voltage is connected to 4n02144n0216, the protection voltage is out from the 4n03014n0305 after switching, the measuring voltage is out from the 4n03064n0308. The switching relay should output the contact used for the bus differential protection, distance protection and failure protection, as well as the output contacts required for the status display and collection. 3.3 General principle drawing, terminal drawing and plug-in layout drawing (The following is only for reference; you can refer to the packing drawing for the actual unit) Connection illustration 4 small voltage bus grouping parallelConnection illustration 3 small voltage bus redundancy parallel edundancy parallelConnection illustration 2 dual-bus voltage switching and parallelConnection illustration I dual-bus voltage switchingsimultaneous actionSame circuit disconnection Power disappearII bus isolation knifeI bus isolation knifeII bus measureI bus measureII bus protection voltageI bus protection voltageInsulation knife locationFigure 3 general principle drawing of JFZ-30QA switching parallel boxJFZ-30Z switching paratactic box Figure 4 JFZ-30QA switching parallel box terminal drawingSwitchingExitJFZ-30Q switching paratactic boxFigure 5 JFZ-30QA switching parallel box plug-in layout drawing4 Operation notice 4.1 Check whether the rated DC

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论