KMX-TYPE MAGNETIZING AND DEMAGNETIZING CONTROLLER FOR ELECTROMAGNETIC SUCKING DISC OF GRINDERINSTRUCTIONXIAN MINGSHI ELECTRO MECHANICAL DEVELOPMENT CO., LTD.1. OVERVIEW Magnetization and demagnetization have been bothering the surface grinder plants and users. The conventional magnetizing/demagnetizing method is through switch manual-control with transformation and rectification ,this method is not only low efficiency in operation but also the magnetizing /demagnetizing effect is not obviously. Especially for the alloy or the material which was being heat treated they have a lot of residual magnetism , which affects the machining accuracy and efficiency, limited the machining range of surface grinder, Conventional magnetizing/demagnetizing method is not unsatisfy the requirement of modern machine industry for the equipment. For resolving these problems, KMX series magnetizer/demagnetizer are be designed and produced by XIAN MINGSHI ELECTRO MECHANICAL DEVELOPMENT CO., LTD. meticulously. Its resolved above problem effectively. The basic functions of the products are below:1. Using integrated circuit control, output without contact, reliability is high. 2. The magnetizing current can be adjusted continually, it means magnetic force can adapt to different electromagnetic sucking disc of grinder for machining different workpieces.3. The demagnetizing process is automatically finished according to the demagnetizing curve, the effect of demagnetization is best.4 .The demagnetizing time is adjustable.5. Against over-voltage, over-current and short-circuit etc.6. The main controller and the electromagnetic disc can take effect interact against under current, this function can be against under magnetism, thus the safety of operator and equipments can be got.7. Small size, installation and testing is convenient.2. TYPE AND TECHNICAL PARAMETER TypeRated input voltage (V)Output voltage (V)Max. output current (A)DemagnetizingTime (s)NotesKMX-1.5/2LQAC220VDC0110V1.5A3-18SAdapt to M7130 and M7450 etc.KMX-03/2-1AC220VDC0110V3A3-18SAdapt to M7140 and M7460 etc.KMX-05/2-1AC220VDC0110V5A3-18SAdapt to M7160 and M7475 etc.KMX-10/2-1AC220VDC0110V10A3-18SAdapt to M74125 grinders etc.Note: 1. Product for special purpose can be supplied also.2. Be selected products of KMX series which maximum output current must be greater than the maximum rated current of electromagnet sucking disc.3. CONDITION FOR NORMAL USING 3.1 Ambient temperature: -10+403.2 Relative humidity: 90% (20) 3.3 Ambience: the place for using the controllers should be away from dust related to explosion and electricity and erosive gas.3.4 Permissible voltage range: within 10%3.5 Installation: vertical, with ventilation3.6 Maximum work current is greater than 10A. Its necessary to assembly an axial-flow fan into the magnetizer /demagnetizer in the designing of a new machine tool, the axial-flow fan can quick scatter the heat (especially in summer), prevent over-heat from damage.3.7 Forbid the iron powder. Dust get into the apparatus, they can result in short-circuit. Especially the grinder is under a dry grinding condition.4. INSTALLATION, ADJUSTMENT AND MAINTENANCE4.1 Requirement to electromagnetic sucking disc4.1.1 Electromagnetic sucking disc must be matched with the controler. The rated current of electromagnet sucking disc=110/interior resistance of electromagnet sucking disc.4.1.2 There is no short-circuit and open-circuit in the interior of coil.4.1.3 Insulation resistor between disc and ground (shell) must not be less than 1M, measured by 500V M multimeter.Suggestion: Its necessary to add an isolating transformer in new machine tools designing or old machine tool s renewing. Because the insulation of electromagnet sucking disc can not be maintenance for a long period, considering from the long period reliability of machine tools, users are better adopt to this suggestion. The method of addition the isolating transformer is: the primary coil of transformer connect with the 380v or 220v power, secondary coil connect with the KMX series magnetizer/demagnetizer column NO3 and 4.4.2Wiring (refer to diagram of outer wiring, terminal codes are printed on PCB).4.2.1DIAGRAM OF OUTER WIRING :3.3kLED23.3kLED1Interlocking contactorInputAC220V/127VOutputDC0110VMagnetizingDemagnetizingNote: LED1 LED2 both are lighting diode, indicated for outside connection (selectable)LED1Magnetizing indicatorLED2Demagnetizing indicator4.2.2AC input are connected to 3#, 4#.4.2.3 DC output are connected to 1#, 2#. 4.2.4 5#, 7#, 8# are used for operation mode. There are three operation modes: magnetizing, pause, demagnetizing. In pause mode 7#, 8# are not closed. A three-position switch is recommended here.4.2.5 5#, 9#, 10# are connected to variable resistor, 9# is sliding terminal (if variable resistor is not used, output voltage can be set by adjusting w2 inside the controller).4.2.6According to requirement to decide whether link outside connection status indicators.4.2.7 11#, 12# are relay contacts both of them are connected to electromagnetic disc, so interlocking between grinder head and electromagnetic disc is realized, in order to prevent damage from magnetism losing.Notice: After power is on, its necessary to check the interlocking contact carefully.4.2.8 The bolt connected to ground is on the right of controller.4.3 Adjustment: Open the top cover of apparatus, the variable resistors w2, w3 and terminals. Fuse can be seen. When adjusting a suitable cross screwdriver must be used. Turn off the power when replacing the fuse.4.3.1w2maximum output voltage adjustment Voltage is reduced clockwise and increases counter clockwise.4.3.2 W3demagnetizing oscillation period setting .the oscillation periods becomes clockwise and longer counter clockwise (generally, 2s is available)4.3.3 W4demagnetizing time settingThe time becomes shorter clockwise and longer counter clockwise (generally, its available between 8 to 10s).4.3.4 Interlocking upper/lower limit settingInterlocking upper/lower limit current can be set by using Thumbwheel switches:No 1, 2, 3, 4 switches of Thumbwheel switch of KMX-10/2 correspond to the limit line setting of 10A, 7 A, 5 A, 3 A. No 1, 2, 3, 4 switches of Thumbwheel switch of KMX-05/2-1 correspond to the limit line setting of 50A, 4 A, 3 A, 1.5A.No 1, 2, 3 switches of Thumbwheel switch of KMX-03/2-1 correspond to the limit line setting of 1A, 2 A, 3 A. Dial the switch to the position of ON, and then, the controller sets the interlocking upper/lower limit to 50%-40% of rated voltage automatically, if the actual value of disc is between the two limit line value of thumbwheel switch, choose the lower one as the setting value.(switch on two switches or more simultaneously is not allowed.) The upper limited current is reduced clockwise and increased count clockwise (generally, 70% of rated current of electromagnetic disc is available).3.5 Adjusting w3 and w4 properly. All kinds of demagnetizing curve can be obtained .So different electromagnetic disc and work piece can be demagnetized satisfactorily.Suggestions: For the alloy, heat-treated material or when the electromagnetic disc has larger inductance, w3 can be adjusted count clockwise until it isnt adjustable and w4 can be adjusted count clockwise slightly.4. Protection checking4.1 Over-voltage protection: when input voltage is too large. The over-voltage protection starts working. Voltage-sensitive element is broken down .The fuse is broken and input channel is cut off. At this time, maintenance should be taken to reduce voltage. After replacing the fuse, voltage-sensitive element and turn the power on again.4.2 Over-current and short-circuit protection: when the over-current or short-circuit appears, the zero output we can get from the controller. At this time, you should turn off the power and check the external connection and electromagnetic disc. If the failure is caused by connection of disc to ground. Its recommended that isolated transformer which matches the discs power can be added to input terminal of the controller.4.3Undercurrent protection:Its divided two types of under current protection: a: When the system starts, the current of electromagnetic disc is less than the interlocking upper limit current (e.g 50% of rated current).The contact of relay does not close, the power loop which link with it is with no reaction; if the current value of electromagnetic disc is greater than the interlocking upper limit of that, the contact of relay close and power loop starts.b: Under the working process of the system, if the working current reduce till the interlocking lower limit (e.g 40% of rated current). Protection relay contact open, the power loop link with it stop working .5. SHAPE, INSTALLATION, SIZE AND EXETERNAL WIRING DIAGRAM:5.1 Shape type: controller can be divided into two kinds by its shape5.1.1 Type Y1:5.1.2 Type Y2:5.2 Shape and installation size (mm)Types ShapeA/A1 B/B1 CinstallationabShape typeKMX-03/2-1182/156130110169114Y1KMX-05/2-1155229/20280140215Y2KMX-10/2-1(10/1-1)170239/215106155226Y26. GENERAL FAILURE IDENTIFICATION AND TREATMENT TroublesTrouble-Shooting1. fuse blows out when applying voltage1.1Check the external connection, turn the power off at first then.1.2Check the resistance between the electromagnetic disc and ground which is not less than 1M.1.3Check the electromagnetic disc, there must not be short-circuit in it.1.4 Check input voltage which should accord with the technique requirement.1.5 The specification of electromagnetic disc and controller must be matched.2. pressure sensitive is exploded when applying voltage, capacity is exploded 2.1 Check the external connection, turn the power off at first then.2.2 Check input voltage which should accord with the technique requirement.3. no output, over-current indictor lights on3.1 Affirm the 1.1 to 1.4 above is right.3.2 Adjust w2 on the middle position first if it on the maximum position initially. Then turn the power on, adjust the w2 on the suit position according to the requirement.3.3 Necessarily, a isolating transformer can be connected at the input position of the controller.4. state of output is not stabilized4.1 There is no output, examine whether the over-current indicator LED display, if its yes, check 3.1to 3.2 above.4.2 Turn the power off at first then check the connection of controller is firm or not.4.3 Check the connection of the electromagnetic disc is firm or not.4.4 Check the coil if the electromagnetic disc contact right or not.5. with output, but the grinder need can not rotate. 5.1 Check the interlocking contact which must be linked with the control loop of the grinder need properly.5.2 Refer to 3.3.4 to set Limit Line parameters properly.6. No output of magnetizing/demagnetizing under the normal condition of fuse and pressure-sensitivity resistance. 6.1 Check the external connection; turn the power off at first then.6.2 6.2 Adjusting the external variable resistor at the minimum limit position first, then adjust it at the middle position, finally turn the power on, adjusting the external variable resistor at a proper position.6.3 6.3 Adjusting variable resistor w2 at the minimum limit position first, then adjusting it at the middle position, uninstalling the external variab

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论