



免费预览已结束,剩余1页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
.Database of the supervisor(S.W. CODE EPSTDECZUA v. 1.4 25/10/99The variables reported below will be transmitted between pCO and supervisor only if all the following conditions will be met:- the serial card is inserted into the proper connector that is found on the interface- the supervisory function is enabled;- the address of the unit is properly select with reference to the supervisory network;- the equipments have been correctly connected to the network (supervisor and pCO).1.1. Digital variables数字变量AddressDescriptionTypeCommunication type1Compressor 1 general alarm digital inputDigitalReading2Compressor 2 general alarm digital inputDigitalReading3Pressure controller 1 low pressure circuit digital inputDigitalReading4Pressure controller 2 low pressure circuit alarm digital inputDigitalReading5Air filter alarm digital inputDigitalReading6Fan thermal alarm digital inputDigitalReading7Air flow controller alarm digital inputDigitalReading8ON/OFF remoteDigitalReading9Resistance 1 thermal alarm digital inputDigitalReading10Resistance 2 thermal alarm digital inputDigitalReading11fire / smoke alarm digital inputDigitalReading12DehumidificationDigitalReading13ON /OFF unitDigitalReading14Energy savingDigitalReading15Humidification / Humidification power contactDigitalReading16Compressor 1 capacity control / Integrated humidifier loadingDigitalReading17Compressor 2 capacity control / Integrated humidifier unloadingDigitalReading183p cold valve opening contactDigitalReading193p cold valve closing contactDigitalReading203p warm valve opening contactDigitalReading213p warm valve closing contactDigitalReading22General alarmDigitalReading23Compressor 1 general alarmDigitalReading24Compressor 2 general alarmDigitalReading25Circuit 1 low pressure pressure-controller alarmDigitalReading26Circuit 2 low pressure pressure-controller alarmDigitalReading27Air flow controller alarmDigitalReading28Fan thermal alarmDigitalReading29Resistance 1 thermal alarmDigitalReading30Resistance 2 thermal alarmDigitalReading31Fire / smoke alarmDigitalReading32Air filter alarmDigitalReading33Ambient high temperature alarmDigitalReading34Ambient low temperature alarmDigitalReading35Ambient high humidity alarmDigitalReading36Ambient low humidity alarmDigitalReading37Compressor 1 operating time alarmDigitalReading38Compressor 2 operating time alarmDigitalReading40Fan operating time alarmDigitalReading43Outlet water high temperature alarmDigitalReading44Outlet water low temperature alarmDigitalReading45Ambient temperature probe failure alarmDigitalReading46Air supply temperature probe failure alarmDigitalReading47Outlet water temperature probe failure alarmDigitalReading48External air temperature probe disconnection alarmDigitalReading49Humidity probe failure alarm DigitalReading51EPROM failure alarmDigitalReading53Temperature regulation type DigitalWriting / Reading55Humidity probe enablingDigitalWriting / Reading56Outlet water probe enabling DigitalWriting / Reading58Inlet water probe enablingDigitalWriting / Reading59Supply air probe enabling DigitalWriting / Reading60Binary combination resistance enablingDigitalReading61Cold modulating valve 0/10V enablingDigitalWriting / Reading62Energy saving enablingDigitalWriting / Reading63Enabling of simultaneous operation of compressors with 0/10V valve DigitalWriting / Reading64Warm 0/10V modulating valve enablingDigitalWriting / Reading65Capacity control enablingDigitalWriting / Reading66Compressor rotation enablingDigitalWriting / Reading67Compressor 1dehumidification enablingDigitalReading68Compressor 2 dehumidification enablingDigitalReading71Temperature time band enablingDigitalWriting / Reading73ON/OFF from supervisor enablingDigitalWriting / Reading743p cold valve enablingDigitalReading753p warm valve enablingDigitalReading76Manual procedure enablingDigitalReading77Alarm-stopped machine alarmDigitalReading78Humidity time band enabling DigitalWriting / Reading80High current in the humidifier alarmDigitalReading82Water absence in the humidifier alarmDigitalReading83No current in the humidifier alarmDigitalReading1.2. Whole variables 整数变量AddressDescriptionTypeCommunication type 10Cold 0/10V valve ramp startWholeWriting / Reading11Cold 0/10V valve ramp endWholeWriting / Reading12Warm 0/10V valve ramp startWholeWriting / Reading 13Warm 0/10V valve ramp endWholeWriting / Reading16Compressor 1 step without energy savingWholeWriting / Reading17Compressor 1 hysteresis without energy savingWholeWriting / Reading18Compressor 2 step without energy savingWholeWriting / Reading19Compressor 2 hysteresis without energy savingWholeWriting / Reading22Compressor 1 step with energy savingWholeWriting / Reading23Compressor 1 hysteresis with energy savingWholeWriting / Reading24Compressor 2 step with energy savingWholeWriting / Reading25Compressor 2 hysteresis with energy savingWholeWriting / Reading26Time interval between same compressor switching onWholeWriting / Reading28Low pressure delay alarmWholeWriting / Reading29Stop minimum timeWholeWriting / Reading30Time interval between different compressor switching onWholeWriting / Reading31Resistance no.WholeWriting / Reading32Compressor no.WholeWriting / Reading33High / low temperature / humidity alarm delayWholeWriting / Reading34Resistance switching on time intervalWholeWriting / Reading38Capacity control 1 step without energy savingWholeWriting / Reading39Capacity control 1 hysteresis without energy savingWholeWriting / Reading40Capacity control 2 step without energy savingWholeWriting / Reading41Capacity control 2 hysteresis without energy energy savingWholeWriting / Reading44Capacity control 1 step savingWholeWriting / Reading45Capacity control 1 hysteresis with energy savingWholeWriting / Reading46Capacity control 2 step with energy savingWholeWriting / Reading47Capacity control 2 hysteresis with energy savingWholeWriting / Reading48Integration timeWholeWriting / Reading50Fan operation time limit WholeWriting / Reading51Compressor 1 operation time limitWholeWriting / Reading52Compressor 2 operation time limitWholeWriting / Reading54Cold 3p valve ramp start WholeWriting / Reading55Cold 3p valve ramp end WholeWriting / Reading56Warm 3p valve start rampWholeWriting / Reading57Warm 3p valve end rampWholeWriting / Reading583p valve complete opening time WholeWriting / Reading59Fan switching on delayWholeWriting / Reading61Cold valve ramp limitWholeReading62Warm valve ramp limitWholeReading63Fan operating-hour carried out high partWholeReading65Compressor 1 operating-hour carried out high part WholeReading66Compressor 2 operating-hour carried out high partWholeReading67Fan operating-hour low partWholeReading68Compressor 1 operating-hour carried out low part WholeReading69Compressor 2 operating-hour carried out low partWholeReading1.3. Analog variables 模拟变量AddressDesc
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 工商银行包头市白云鄂博矿区2025秋招笔试英语阅读理解题专练30题及答案
- 工商银行阿拉善盟阿拉善左旗2025秋招笔试金融学专练及答案
- 邮储银行蚌埠市淮上区2025秋招笔试法律专练及答案
- 邮储银行凉山彝族自治州西昌市2025秋招笔试数量关系题专练及答案
- 干部培训内涵建设
- 中国银行唐山市开平区2025秋招笔试经济学专练及答案
- 中国银行南京市鼓楼区2025秋招笔试英语阅读理解题专练30题及答案
- 邮储银行那曲市索县2025秋招笔试英语完形填空题专练30题及答案
- 中国银行扬州市高邮市2025秋招笔试英语阅读选词题专练30题及答案
- GJB9001c质量知识培训方
- 压力管道特性表
- 高级会计师评审个人业绩报告(精选9篇)
- 血管活性药物(ICU)课件
- “手电筒”模型-高考数学解题方法
- 储能型虚拟电厂的建设与思考分析报告
- 楼地面装饰构造(史上最全面)
- GB∕T 2980-2018 工程机械轮胎规格、尺寸、气压与负荷
- 海关AEO管理体系高级认证企业名录
- TTAF 068-2020 移动智能终端及应用软件用户个人信息保护实施指南 第8部分:隐私政策
- DB32∕T 4065-2021 建筑幕墙工程技术标准
- 《国家自然科学基金申请经验交流》PPT共30页课件
评论
0/150
提交评论