快速卷帘门安装及调试 英文说明书.doc_第1页
快速卷帘门安装及调试 英文说明书.doc_第2页
快速卷帘门安装及调试 英文说明书.doc_第3页
快速卷帘门安装及调试 英文说明书.doc_第4页
快速卷帘门安装及调试 英文说明书.doc_第5页
已阅读5页,还剩3页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Rapid rolling door Installation instructions I.The tools for installation workImpact drill (with 14 mm, 12 mm, 6 mm drilling bit), hand drill (with self tapping screw, drilling bit, etc.), polishing machine, pneumatic hand riveter, electric welding machine (optional), 14/17, 12/22 wrench toolII.Installa Door1. lay the doorcase on the ground flat,fixed the rail on the doorcase(with 10mmX20 screw,nut,8 pc screws),erect the the doorcase with machine or human force, and then with 14mm impact drill drilled the hole after fix the doorcase installation position.use expansion screws fix doorcase,install the rail on the groun or wall.2. Fix the motor on the motor plate(8mm X 20 size screw,4 pcs),insert the latch into keyway,and then put the motor on the axis of the door shaft.(with 12mmX70 screw fix motor plate on the side plate of the doorcase,set the encouder on the small axis(beside motor),encoder outside fix on the motor,inside rotate part fix on the small axis(fasten the Hexagon screws,and fix the stainless plate which one the encoder).III.High Speed door debugging illustrationThe wiring column displayed as follows: :U V W L02 N01 X0 X1 24V 0V X2 X3 X4 X5 X6 X7 X7 24V 0V COM 24V 0V Connection details:Power supply: live wire is L,L,L, null line is NMotor: the motor, U, V, W line connected to the terminal, U, V, W line respectively (matched each other), If reversal,adjust two of three line U,V,W random,and the other two line connect to LO2,NO1.Encoder: green, yellow, brown, white, connect to XO, X1, 24V, 0V respectively ( if the door not working after limited is ok,interchange the X0 and X1 line).Infrared connection : blue and white connect to 0V, brown connect to 24V, black connect to X7. another 24V brown, blue 0V。Magnetic connection: 1, 2 connect to 220 v power supply(L,N); 3, 4 connect to X7, COM respectively; 7, 8 connect to coil respectively.Manual button: green button 24 connect to terminal X2, red button 24 connect to terminal X3, emergency stop button 4 connect to terminal X4. red button 23 connect to terminal COM, the red button 23, green button 23 and emergency stop button 3 short circuit(note: when the debug, terminal X6 and terminal COM short circuit,until the top and bottom limited is finished,then remove the line.adjust top limited first and then adjust bottom limited.)Remote connection: two black line is 220V, white and yellow to X2, X3, red connect to COM.radar connection: red connect to 24V,red-white connect to 0 v, white connect to X7.radar connection: brown connect to 24v, yellow-green to 0V, white to X7.Interlock connection: 1 # doors Y0 connect to 2 # doors X4 , 1 # doors COM1 connect to 2 # doors COM; 2 # doors Y0 connect to 1 # gate X4 , 2 # doors COM1 connect to 1 # gate COM。 Airbag wiring.: red-black connect to 220V, green connect to X2, yellow connect to 0V.IV. frequency converter operation instruction.1. Operation process.Electricity - display - the rdyPress MODE - display - rEFClockwise rotation button - display - the Set -Press Rotate button - display - ACC, press the spin button - display - 3, counterclockwise spin - instead of - 1, the press rotating button,confirmation, press the ESC exit - display - ACCClockwise rotation button - display - dEC, press the spin button - display - 3, counterclockwise spin - instead of - 1, press rotating button, confirmmation,press the ESC exit - display - dECPress ESC to exit - display - the Set,Clockwise rotation button - - I - O -Press the rotate button - display - tCC, clockwise rotation button - found - r1, press the rotate button - display - PLT, clockwise rotation button - to - rUn, press ESC to exit - display - I - O -Clockwise rotation button - found - FUn -Press rotate button - display - rPC -,clockwise the button- found - PSS - rotation, press rotate button - display - the PS2,Clockwise rotation button - found - PS8,press rotate button - display - nO , clockwise rotation button - to - LI5, press rotating button and confirm, press ESC to exit - display - PS8,Clockwise rotation button - found - SP4, press rotate button - display - 20 , press clockwise button- to - 40, press rotate button and confirm, press the ESC exit - display- PS4Clockwise rotation button - found - SP5, press rotate button - display - 25 , counterclockwise rotation button - to - 20, press rotating button and confirm, press ESC to exit - display -PS5 Clockwise rotation button - found - SP6, press rotate button - display - 30 ,clockwise rotate button - to - 40, press rotating button and confirm, press the ESC exit - display - PS6Press ESC to exit - to - rdyThe End2. Parameter illustration.(1)P5: closed the door low speed frequency 20(2)P6: opened the door lowspeed frequency 25(3)P7: acceleration time 0.5(4)P8: deceleration time 0.5 (5)P25: open the door high speed frequency 38 (6)P26: closed the door high speed frequency 35(7)P1:192 0Geomagnetic Installation:Cut a 0.9m X 1.5m square shape on the ground with cutting machine,this square shape should be about 1.5m-2m before door.the groove depth should be 4cm,width 4cm.twine 5 circle around groove with 0.75 square meters wire,and connect two side of the wire into control box.Magnetic connection (DZ1 type) : power null line (1), power live line (2), X2 (3), COM (4), wire loop,2 pc wires (7, 8), dial code switch 2 (ON), 7 (ON), and other OFF)Magnetic connection (DZ2 type) : power null line (1), power live wire (2), X2 (5), (6) - 24 v, wire loop,2 pc wires (7, 8), dial code switch (7 (OFF), the other ON)Magnetic connection (DZ3 type) : +24 connect to equipment +, -24V connect to equipment-, -24 connect to the upper right the first receiver, X2 connect to upper right the second receiver of equipment. Wire loop 2 wires connect to equipment wire loop position, two set dial code switch are all 1,2(ON),the other OFFDebugging limited:Note: before debugging limit must put motor (U, V, W, L02, N01), the encoder (24 V, 0 V, X0, X1)Connect the power to the circuit breaker(220V have two wires,live line and null line,380V have 4 lines,3 live line and 1 null line),open the air switch in the control box,check frequency,whether the PLC indicator lamp is ok,if all ok,pls debugging limited as below.(NOTE: short circuit the X6 and COM during debugging,until upper and lower limited ok,and remove the wire).1. upper limited confirmationchange to debugging status(short circuit the line X6 and COM, IN6 light on),change manual/automatic button into manual status,press up button,confirm upper limited.after upper limited confirmed,press stop button(X4 light on),press up button 5 seconds at the same time,then upper limited is ok.2. lower limited confirmation.change to debugging status(short circuit the line X6 and COM, IN6 light on),change manual/automatic button into manual status,press down button,confirm lower limited.after lower limited confirmed,press stop button(X4 light on),press down button 5 seconds at the same time,then lower limited is ok.3. automatic close door time adjust.Change to debugging status(IN6 light on),press stop button(IN4 light on),the automatic close door time will decrease one second after press down button one time. The automatic close door time will increase one second after press up button one time.(NOTE: short circuit the X6 and COM during debugging,until upper and lower limited ok,and remove the wire).V、The control box circuit fault1, Fault phenomenon: limited not accurate or does not work, elimination method:check whether encoder installation firmly,re-set limted,if still not accurate,change encoder or change break.2, Fault phenomenon:the break does not work, elimination method,check whether have break signal output(the PLC left side 1# light on when door running,the PLC left side 1# light off when door stop),if signal ok, check the line LO2 and NO2 voltage whether is 220V, Normally,it have 220V when door runing,it is no voltage when door stop, if not,pls contect factory.3,Fault phenomenon:door can not close automatic,check PLC output 7 light always on, if light on,check photo sensor,rador and other external equipment whether can supply signal constant,if yes,check one by one,if the problem also can not solved.contact factory.4,Fault phenomenon:photo senor(airbag) invalid,check PLC output,if block,photo sensor right side 7# light off(or pinch the bottom of airbag),change photo sensor switch(airbag),if right side 7# light on,contact factory.5,Fault phenomenon:rador invalid, elimination method:check control box whether on automatic status,only on automatic status,can rador be valid.if indeed on automatic status,whether green light on(in normal status,rador is red light on) when rador scan human or object.if green light not on,change rador,if green light on,check PLC output,PLC right side 7# light whether is on,7# light not on,it means the line from rador to control box have problem,check and change line,if 7# light on,contact factory.6.Fault phenomenon: geomagnetism is invalid,elimination method:check control box whether on automatic status,only on automatic status,can geomagnetism be valid,if indeed on automatic status,when truck pass through geomagnetism loop,check PLC output,whether right side 7# on,if not on,check whether geomagnetism line is ok,if 7# light on,contact factory.7.Fault phenomenon:the door does not work.elimination method:cut of the power supply and re-supply poew,check whether PLC input and output are ok(which indicte light flash on the left side,and which indicate light flash on the right side),write down input and output status,and contact factory.8,Frequency fault:Frequency alarm(frequency display screen have fault information),contact factory.VI、High speed door description.Configuration:Schneider programmable frequency system,24V DC power,limited,over load protect,switch.Door fram structure: BAO steel galvanized steel plate,anti-corrsion treatment,250 degree power treatment,polish surface,grey or grey-white color,steel plate thickness 2.0mm.there is safty airbag at the bottom of door slat,it is can close to all kinds of uneven ground, brush in the guide track.Curtain material:0.9mm thickness high tension PVC curtain from France,double side coated,blue,yeally and grey color for option, the PVC visiable window in the middle,aluminum rib to anti-wind.Control system: PLC control system, inbuilt complexor control mode,high torgue frequency(150% IHZ),PLC 2 in 1,system accurate,safe,it can compatible with all kinds of protection equipment.Power performance:SEJ famous brand system,1.5kw/200v voltage,1350RPM,brake,low noise,Safty performance:the product itself do not have anti-guard function,it can add other industrial product it realize anti-guard protect,the program adopt figure program,sensor system(it can avoid any fault or accident due to long term high speed rotate).Manual device:motor system contain manual operate device when power failer or other emergency accident,it can use manual rocker to oper the door(optional)Fault recovery: branded high speed door can realized faulty revovery function,turn of power 10 seconds,and re-power supply,the system will be automatic recovery.Anti-wind performance:door have anti-wind device and anti-wind rib.Working speed:open 0.6-1.3m/s,close:0.6-1.0m/s,high frequency open,1100-1550time/day,open and close speed can be adjusted according to requirement.Seal performacne:there is anti-dust brush in the guide track,bottom rubber can match all kinds of uneven ground,it can anti-dust,anti-pest,anti-wind.anti-noise.keep war

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论