电力用高频开关电源模块技术手册(英文).doc_第1页
电力用高频开关电源模块技术手册(英文).doc_第2页
电力用高频开关电源模块技术手册(英文).doc_第3页
电力用高频开关电源模块技术手册(英文).doc_第4页
电力用高频开关电源模块技术手册(英文).doc_第5页
已阅读5页,还剩10页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

High-frequency switch power supply moduleProfessional achievement of excellenceHF Switching DC Power Supply System2 attachment:High-frequency switch power supply module technical manualSI CHUAN AHAIFA ELECTRIC CO.,LTD.OF CHINAIndexChapter 1 Overview.21.1 Perface21.2 Characteristic of the system.21.3 Main characteristic of the module21.4 Type nomination.41.5 Technical characteristics.5Chapter 2Operating Condition.6Chapter 3 module configuration.63.1 Operating diagram of the charging module.63.2 Dimension73.3 Installation of module.8Chapter 4 Operation Introduction94.1 Digital display panel.94.2 Indication light94.3 Buttons for displaying switch.104.4 Manual adjusting voltage button.104.5 Dial switching.10 4.5.1 Control options code.10 4.5.2 Broadcast address identification code.11 4.5.3 Address setting dial.114.6 Fault Display.124.7 Communication Function.12Appendix.13Chapter 1 Overview1.1 PerfaceThe company is greatly supported by the national science and technology department. On the base of advanced high-frequency switch power supply technology, the company invented TH series high-frequency switch power supply module which can fully satisfy the requirements of modern electric system. The product has been widely used in the DC system and relative equipments of power plant, transformer substation etc. of various voltage degree. The TH series high-frequency switch power supply module, has been applicated in many fields,such as computer、avigation ,instrument,especially in comunication.In the 1990s , The high-frequency switch power supply has been equipped in many country.1.2 Characteristic of the systeml Modularization design, realize N+1 backup;l The friendly man-machine interface. Large screen to show, realize man-machine dialogue operate really.l RS-485 inrerface, realize “4 remote” function with monitor machine.1.3 Main characteristic of the modulel High efficiency, Nearly 94%;l Lightly, 16kg;l Little volumel After the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor0.94;l Function against reverse pour: each module has been added diode against reverse pour at output terminal.l LED digital screen, digital calibrate, stable current ,fault alarml Output overvoltage protection To prevent the disastrous accident caused by outputting overvoltage to electric consumers, there is overvoltage protection circuit in the module. After output overvoltage occurs, the module locks up automatically, the relative module fault indication light is on, the faulty module quits work automatically and doesnt affect the normal operation of the entire system. The overvoltage protection point is set when ex-factory, 182V5V is set for rated output 110V machine type.l Output current limiting protect The output current cannot increase infinitely. The maximum value of the output current of each module is limited to the rated output current 105%, in this range, the output current value of the module is continuously adjustable. If the load output of the module, the module will play down the output voltagel Output short-circuit protectionWhen output short circuit, the module draws the output voltage to 0 immediately, limit the short circuit current below 15%limit current point to protect the module. The module will not be damaged under short circuit state for a long time, and can go back to work automatically after debugging. Fig.1-1 Output Characteristicl Module parallel protectionThere is parallel protection circuit in each module to ensure when the faulty module quits the system, the normal work of other modules and the system is not affected. Fig.1-2 output of module parallell Over-temperature protectionOver-temperature protection is mainly for protecting large power converters, under normal operating circumstance, the module design leaves enough margin, under special circumstance, when the module detects that the temperature of the radiator is over 85, it will shut down automatically to protect itself. When the temperature reduces below 75, the module will start up automatically.l Output over-current protectionBecause of the limit of the module output power, the output current cannot increase infinitely. In the range, the output current value of the module is continuously adjustable. If overloaded, the module can reduce output voltage automatically to make it not surplus the rated output limit point in order to protect the power components. The overcurrent protection can be resumed automatically.1.4 Type nominationTH Series number 3: Casts the kneading boardZZ:natural cooling module;rated output current: 40Amodule:D is electric power modulerang of the output voltage110 for 110V electric power module 公司名称: 通合 1.5 Technical characteristicsThe TH110D40ZZ-3-AHF of the module technical index moduleproject TH110D40ZZ-3rated output current(A)40power(KW)6weight(kg)16cooling methodnatural coolingheat sink temperature rise30rang of input AC(VAC)min353Typical value415max477rang of the output voltage(VDC)min93Typical value110max175stable voltage accuracy:0.5%stable current accuracy:1%PFC0.93Efficiency94%noise(dB)50Storage temperature()min-40Typical value25max60working temperature()min-10Typical value25max40And machine uneven fluidity3%time delay of start-up(s)38Wave factor0.2%Load100% rated output currentstepless current limiting techonolyThe output current cannot increase infinitely. The maximum value of the output current of each module is limited to the rated output currentOutput overvoltage protection functionAfter output overvoltage occurs(1825VDC), the module locks up automaticallyoutput short circuit protection When output short circuit, the module draws the output voltage to 0 immediatelyNote:The constant voltage precision does not contain the built-in isolating diodes influence。Chapter 2 Operating Condition1、 Altitude 2000m;2、 Storage temperature: -40+60;surrounding temperature: 10C 40C;3、 Relative humidity: 96(operating temperature 25C);4、 No conductive and explosive dust, no caustic gas;5、 Used in room;6、 If in does not conform to the above condition special environment to use, Users should be made in order To ensure that the products work reliably.Chapter 3 Module Configuration3.1 Operating diagram of the charging module415VAC inputInput protectionFull bridge rectifier circuitreactivefilteringHigh frequency TransformerHigh frequency Rectifier circuitOutput protectionDC outputSoft switch resonance loopOver-voltageshort-circuitover-currentOver-temperaturemodule parallelFeedback samplingMicroprocessorRS 485LEDFunctional block diagram 3.2 DimensionTH110D40ZZ-3-AHF natural cooling module dimension sketch map:sketch map of the front panel of the module sketch map of the back of the moduleoutline drawing of the module3.3 Installation of moduleTH110D40ZZ-3-AHF of the definitions of the plug socket(JMD29T) of live line inserting and pulling out are as followsportstandarddefinefunction 1、312#DC+DC output+2、412#DC-DC output-2612#GEARTH2712#AInput 415V2812#BInput 415V2912#CInput 415VNote:No define port is emptyThe module top, bottom, left and right request has the good natural ventilation environmentBetween the module even streamline defers to “flows +” and “flows -” the direct company to be possible to realize the module together independently to flowBetween the module RS485 line A and B link separately in the same place, with main monitorings lower position machine RS485 A, the B connection then realizes the main monitoring to the module automatic control.Chapter 4 Operation IntroductionFigure 4-1 Front panel4.1 Digital display panelThe Digital display panel shows the information of voltage, current, alarm, shutdown. Switching button for display shows the output voltage and current switching. There are 3 digitals can be displayed, the accuracy of voltage is 0.5V, the accuracy of current is 0.2A. When the module alarms, the fault code can be displayed by pushing the switching button. When the module shut down, the shut down code can be displayed by pushing the switching button .4.2 Indication lightThere are three indication lights on the module panel,table 4-1 shows the function of them.table 4-1Marking instructionsNormal State Abnormality State Abnormality ReasonsPower indicator light (green)onoffNo input voltage resulted in the internal auxiliary power supply module does not work overtemperature light (red)offonModule internal overheatingFault light (red)offonModule internal fault 4.3 Buttons for displaying switchThe Switching button is used to switch what LED displays. If the LED are displaying the output voltage, then you push the button, there will be display output current, if you push the button again, then it will also display the output voltage. 4.4 Manual adjusting voltage buttonTwo buttons embedded in the panel are used to adjust the output voltage in the manual state. The output voltage will at the lower of 1V,when the left button is pushed; also the output voltage will arise 0.5V when you push the right button. You must pay attention to that this button is working only in manual state.4.5 Dial switchingDial switching are used to select the control module and mailing address. Definition is shown in Figure 4-2Figure 4-24.5.1 Control options codeThe dial switching of the farest left is dial-control options, selecting the automatic control or manual control. Control methods for allocation allocated under manual control, as shown in Figure 4-2. In automatic control mode, the modules output voltage limiting, switching planes are monitored by module control,artificial can not intervene it . If modules for rechargeable batteries to switch on the bus, the general approach should be set up for control. In manual control mode, the output voltage can be adjusted by the manually button. Module output voltage limiter point and switch control module from machine control, etc. However, the operating parameters can be reported to the Control Module.If connected to the control bus module, the module will need a single output voltage stability. At this time should be set up for manual module state, the module output voltage surge by manual adjustment buttons, limiting points are all relaxed, about 105%.Note:Surge button manual recharging module will reach a maximum output voltage 175V. Do not adjust the normal system in the random button. Since different users have different choices and the number of battery, for the sake of safety, Charging module output in the whole factory has been set at the Floating 117V voltage values.4.5.2 Broadcast address identification code The left side of Switching dial-second is broadcast address identification code allocated,used to identify the broadcast data packets. Appropriated for the top, a module of Group 1, the broadcast data packet with 255 of 253; appropriated the bottom, a module of the second group, the broadcast data packet with 254 and 255.4.5.3 Address setting dial Four of dial switching with the right allocation of broadcast address identification code addresses communications module installed together constitute dial, The mailing address for the module. Module installed in the mailing address in binary, every allocation of representatives allocated upward binary code 0 appropriated to represent binary 1. One addresses the right to set up most of dial-lowest, the most left one of the highest places. TH110D40ZZ-3-AHF charging module addresses set up for dial-five. Therefore module addresses the range of 031, that is the control module with a serial port to connect the largest number is 32. Module addresses is the only identification signals that charging control module identify others. the same system can not be installed at the same module. To the same modules, control modules to be installed mailing address, which should be the same with communication modules. Control module installed in the module addresses a number of the metric system, 4-2 with the conversion table.table 4-2Binary0000000001

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论