本装置能量测4组个别电压输入.doc_第1页
本装置能量测4组个别电压输入.doc_第2页
本装置能量测4组个别电压输入.doc_第3页
本装置能量测4组个别电压输入.doc_第4页
本装置能量测4组个别电压输入.doc_第5页
已阅读5页,还剩6页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Voltage measurement kit for personal computer Oct-20-2001 a kit can measure four individual voltage inputs and the associated program can record the data into the file report.txt in Windows. the kit has two digital outputs for the pass-or-fail out, one is the AND function for the measurement 1 and 2 ,the other is the AND function for the measurement 3 and 4. In addition, the kit has two digital inputs for the data recording management, one is to save the file continuously while the input is low, the other is to save the file only when the input is transiting from high to low. the sub-VI (option 00B) is available for LabView programmer, also the advanced software dll file (option 00C) is provided, then user can use those files to control the kit with other program platforms which are preferred.本裝置能量測4組個別電壓輸入,且透過其程式將量測資料記錄於檔案report.txt於Windows系統下. 此裝置有兩組判別pass-or-fail的數位輸出,其中一組是針對量測電壓1及2的AND結果值, 另外一組是針對量測電壓3及4的AND結果值. 這裝置還有兩組數位輸入,一組當輸入是low時量測資料會連續記錄入檔案,另一組則只當輸入從high變 low才記錄該量測資料. Option 00B 提供sub-VI 程式給LabView 程式開發者, option 00C 提供.dll程式給任何其他程式平臺開發者來控制此裝置.Install procedure:1. copy the files vmk.exe and lkut.txt into c:vmk 2. connect RS232 cable to the kit.3. run the program vmk.exeif you have any questions about the program and kit, please contact us (). 安裝程序:1. 拷貝vmk.exe 和 lkut.txt 到路徑 c:vmk2. 連接RS232線到電腦.3. 執行vmk.exe程式. 假如有任何問題請寫 E-mail至Fig1. When the program starts, it searches for the kit automatically by the RS232, If it cant find the kit, it will show the warning message.Fig1. 當程式執行,它會透過RS232尋找控制裝置,如果找不到會顯現警告訊息.Fig2. First you can switch on or off of each measurement by pushing the enable buttons. There are four individual measurements ( F1 to F4 ) for four inputs. In each measurement you can set the high and low limits for the output. if the measurement passes then the indicator at the left side of the enable button turn green, otherwise red.Fig2. 首先你能按enable鈕打開或關閉各項量測.共4項量測針對4個輸入,每項 量測都可設定high 及low判斷界線,假如通過則enable左邊燈號亮綠色, 否則為紅色.Fig3. Pull down the AVE factor selector to select the average factor.Fig3. 拉下AVE factor鈕可選擇平均值設定.Fig4. Pull down the function selector to select the calculation functions for the outputs.Fig4. 拉下功能選擇鈕可選擇對輸出對輸入的計算功能.Fig5. in measurement 3,4 there has an additional calibration factor, it helps match the real input voltages with the outputs shown. But in measurement 1,2 they are calibrated from the look up table in the file lkut.txt, the advantage of that is able to transfer the real inputs into any nonlinear data as you like, because the look up table of the lkut.txt file can be defined by user. Fig5. 量測3及4有額外的校正參數可設定,此可助調整顯示的輸出與輸入實質 的吻合.但量測1及2是以查表法來校正, 查表檔案為lkut.txt, 內容可由使 用者自行設定,其優點是可轉換輸入值成任何非線性關係之輸出值.Fig6. Here shows the four A/D converters status.the bar lines should vary within the range during measuring to indicate the data is not saturation or cut off.Fig6. 有4條長線顯示A/D轉換器的狀態, 量測時線長會隨輸入變化,但須在此 頭尾區間內,才表示量測未超出A/D轉換的截止或飽和界限.A/D and digital I/O interface external power supply RS 232 interfaceA/D轉換和數位輸出入界面 外部電源輸入口 RS 232界面Fig7. The voltage measurement kit. (a). external power supply (Vs) : 39V, notice the center pin is “-“ .(b). A/D and digital I/O interface : there are 4 A/D converters which input voltage range is from 0 to Vs if external power is applied, or from 0 to the voltage of the RS232 (from PC) if external power is not applied. 2 digital inputs and 2 digital outputs are TTL with the logic voltage from 0 to Vs or RS232s voltage. (c). RS 232 interface : should be connected to PC. Fig7. (a)外部電源供應Vs由3到9V,注意中心pin為負極. (b)A/D及數位輸出入的電壓範圍是由0到Vs, 若外部無電源供應,範圍則 從0到電腦給RS232的電壓. (c) RS232須接至電腦.The connection of I/O interface :Top view from fig.7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1. NC2. NC3. GND4. GND5. GND6. NC7. NC8. NC9. GND10. AD1 input11. AD2 input12. AD3 input13. AD4 input14. digital O/P 1 ( measurement 1 AND measurement 2 )15. digital O/P 2 ( measurement 3 AND measurement 4 )16. digital I/P 1 (the file saving function , once at each transition from high to low ) 17. digital I/P 2 (the continuously file saving function, active low )18. GND electrical characters :AD input impedance 47 k ohmdigital input impedance 10 k ohmdigital output current 10 mAThe file contain for the Look up table :A0=x0, B0=y0,A1=x1, B1=y1,A2=x2, B2=y2,A3=x3, B3=y

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论