全球主要“LC-MS”生产厂商及其产品比较一览.doc_第1页
全球主要“LC-MS”生产厂商及其产品比较一览.doc_第2页
全球主要“LC-MS”生产厂商及其产品比较一览.doc_第3页
全球主要“LC-MS”生产厂商及其产品比较一览.doc_第4页
全球主要“LC-MS”生产厂商及其产品比较一览.doc_第5页
已阅读5页,还剩5页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

全球主要“LC-MS”生产厂商及其产品比较一览SupplierSystemType mass-analyserMass (m/z)-rangeLC-MS interfacesData-acquisition and processing softwareCompatibility in control of LC-systemsRemarksAgilent TechnologiesAgilent-1100 LC-MSD VL en SLSingle-quadrupole50-3000ESI, nano-ESI, APCI, APPILC/MSD, integrated with Agilent-3D LC ChemStationAgilent 1100 and CE systemAgilent TechnologiesAgilent-1100 LC-MSD-Trap VL en SLIon-trap50-2200 (tot 4000 met extended mass range)ESI, nano-ESI, APCI, APPI, AP-MALDILC/MSD trap, integrated with Agilent-3D LC ChemStationAgilent 1100 and CE systemAmersham BiosciencesEttan (micro)LC-MSTOF20 - 20.000ESIone software platform for controlling, acquisition, evaluating data obtained by MS and LC.MW 150.000 d (from small peptides to large megadalton complexes); integrated column switching for on-line sample cleanup, desalting, and concentration. 10E4 linear dynamic rangeApplied BiosystemsAPI-150EX TM LC/MS Systemsingle-quadrupole3000(Micro- and Turbo-) IonsprayTM source, APCI TM source, nanosprayANALYST TM Software (WindowsNT), Add on tools: IDA (Information Dependent Acquisition). Automaton, Metabolite IDPE Series 200, Agilent Series1100 and CapLC, Shimadzu LC-10A and LC-8A, Gilson Autosamplers,CTC Pal autosampler, Harvard Syringe pump, Spark Endurance autosampler, LC Packings UltimateAlso available as complete Discovery and Prep Workstation with required softwareApplied BiosystemsAPI-2000TM , API-3000TM and API-4000TM LC/MS/MS Systemtriple-quadrupole1800 (API-2000); 3000 (API-3000 and API-4000)(Micro- and Turbo-) Ionspray, APCI, nanospray for API-2000 and API 3000, Turbo V source, Ionspray, APCI for API-4000ANALYST (WindowsNT), Add on tools: IDA (Information Dependent Acquisition). Automaton, Metabolite IDMS-MS with LINAC collision cell, API-3000 and 4000 with additional sensitivityApplied BiosystemsQSTAR Pulsar i TM LC/MS/MS Systemquadrupole-time-of-flight hybrid12000(Micro- and Turbo-) Ionspray, APCI, nanospray, PhotoSprayANALYST (WindowsNT), Add on tools: IDA (Information Dependent Acquisition). Automaton, Metabolite ID, BioAnalyst, Pro-ID, Pro-ICATMS-MS with high resolution in MS2. With LINAC (PULSAR) collision cell. Mass accuracy 5 ppm, differential expression studies. Also MALDI-source available.Applied BiosystemsQTRAP TM LC-MS/MS Systemquadrupole-linear ion trap hybrid1800(Micro- and Turbo-) Ionspray, APCI, nanosprayANALYST (WindowsNT), Add on tools: IDA (Information Dependent Acquisition). Automaton.With LINAC collision celll. Qualitative- and quantitative analysis on an instrument with extended Scan functionality: Enhanced MS (EMS), MS3, Enhanced Resolution (ER), Enhanced Product Ion (EPI), Enhanced Multiply Chrg.(EMC), Timed Delayed FragmentationSpecial Metabolite-ID and Proteomics systems availableBruker DaltonikEsquire 2000Ion-trap2200ESI, APCIWindows 2000 based ESQUIRE-NT 5.0, HYSTAR LC control, Agilent ChemStation integrated for 1100 series HPLC and 3D CE control, data-dependent acquisition with ActiveExclusion, SmartFrag, SelectFrag, AutoMaxRes Mode; Windows post-processing modules QuantAnalysis, LibrarySearch, ACD (Structure Editor), MetaboliteTools (Metabolite identification)Agilent 1100MSn (n=3), Auto-MS/MS2, mono-isotopic isolation for m/z 2200, benchtop with small footprint, separate rough pump in noise dampled cabinet; patented orthogonal sprayer,on- and off-line Nano-ESIGrounded needle (CE/MS),On-line nanospray, AP MALDIBruker DaltonikEsquire 3000plusIon-trap6000;up to 3000 with variable scan speed and resolutionUltrasensitive ESI, APCI, on- and off-line Nano-ESI, APPIAgilent 1100, Waters, LC Packings UltimateMSn(n=11), Auto-MS/MS3, fast polarity switching ( 300 ms), mono-isotopic isolation for m/z 10,000 m/zESI, APCI,HyStar LC control; X-MASS-NT 4.0/ win2000 (acquisition, processing, plotting and analysis) Biotools (proteins) MASCOT (database search)Agilent 1100, Waters, LC Packings UltimateMass accuracy 20000; Dual-spray for calibration. Compass multipass-reflectron, AP-MALDI source. Upgradeable to Bio-TOF QNano-ESIBruker DaltonikBio-TOF QQuadrupole-time-of-flight (ESI-Q-q-TOF with Multipass reflectron) 10,000 m/zESI, APCI,HyStar LC control; X-MASS-NT 4.0/ win2000 (acquisition, processing, plotting and analysis) Biotools (proteins) MASCOT (database search)Agilent 1100, Waters, LC Packings UltimateQuadrupole ptrecursor mass selector to m/z 4000, Mass accuracy 20000; Dual-electrospray for calibration. Compass multipass-reflectron, AP-MALDI sourceNano-ESIBruker DaltonikAPEX IVFourier Transform Ion-cyclotron Resonance 15,000 m/zESI, APCI, Nano-ESI, EI, CI, SIMS, and MALDIHyStar LC control; X-MASS-NT 4.0/ win2000 (acquisition, processing, plotting and analysis) Biotools (proteins) MASCOT (database search)Agilent 1100, Waters, LC Packings UltimateInfinity Cell, Mass accuracy 2.000.000, MSn (n10000APCI, ESI, Frit-FAB, nanoflowJeol software (Windows)Agilent-1090 en 11005000 Resolution, Benchtop Model, Full Automatic Probe Analysis, MS/MS Linked scanJEOL (EUROPE) B.V.Mstation JMS-700magnetic sector, double focusing25000APCI, ESI, Frit-FAB, nanoflowJeol softwareAgilent-1090 en 110060000 resolutionJEOL (EUROPE) B.V.AccuTOFTOF10000ESI,APCI, Nano Flow, Corona ESIJeol software (Windows)Agilent-1090 en 1100High Dynamic Range, High Resolution, High SensitivityMicromassLCTtime-of-flightExceeding 20000Z-spray; ESI, APcI, Nanoflow Picospray and CE-MS interfaces, LockSpray; Multiplexed Electrospray 2,4 or 8 channel MUX option, with Lockmass.MassLynx 4.0 (Windows XP, NT or Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated couplings to: pd-quest, ACD, nugenesisMicomass CapLC, Waters CapLC,Waters Alliance,Waters 600, Waters Breeze, Agilent 1050, 1090, 1100, JASCO, Gilson, Shimadzu and specific injectors like CTC PAL.Bench-top Mass accuracy: 5 ppm over m/z 150-900. 5000 resolution.MicromassQuattro-Microtriple-quadrupool1800Z-spray; ESI, APcI Nanoflow Picospray en CE-MS interfaces, LockSpray; 4 kanaals MUX optie beschikbaarMassLynx 4.0 (Windows XP, NT or Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated couplings to: pd-quest, ACD, nugenesisMicomass CapLC, Waters CapLC,Waters Alliance,Waters 600, Waters Breeze, Agilent 1050, 1090, 1100, JASCO, Gilson, Shimadzu and specific injectors like CTC PAL.Bechtop MS/MSMicromassQuattro-Ultima-Pttriple-quadrupool4000Z-spray; ESI, APcI Nanoflow Picospray en CE-MS interfaces, LockSpray; 4 kanaals MUX optie beschikbaarMassLynx 4.0 (Windows XP, NT or Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated couplings to: pd-quest, ACD, nugenesisMicomass CapLC, Waters CapLC,Waters Alliance,Waters 600, Waters Breeze, Agilent 1050, 1090, 1100, JASCO, Gilson, Shimadzu and specific injectors like CTC PAL.Bechtop MS/MS, iontunnel collision cellMicromassQ-TOF-Microquadrupool-vluchtijd hybrideExceeding 20000Z-spray; ESI, APcI Nanoflow Picospray en CE-MS interfaces, LockSpray; 4 kanaals MUX optie beschikbaarMassLynx 4.0 (Windows XP, NT or Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated couplings to: pd-quest, ACD, nugenesisMicomass CapLC, Waters CapLC,Waters Alliance,Waters 600, Waters Breeze, Agilent 1050, 1090, 1100, JASCO, Gilson, Shimadzu and specific injectors like CTC PAL.Bench-top Hybrid MS-MS. Mass accuracy: 5 ppm over m/z 150-900. 5000 resolution.MicromassQ-TOF-Ultima APIquadrupool-vluchtijd hybrideExceeding 20000Z-spray; ESI, APcI Nanoflow Picospray en CE-MS interfaces, LockSpray; 4 kanaals MUX optie beschikbaarMassLynx 4.0 (Windows XP, NT or Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated couplings to: pd-quest, ACD, nugenesisMicomass CapLC, Waters CapLC,Waters Alliance,Waters 600, Waters Breeze, Agilent 1050, 1090, 1100, JASCO, Gilson, Shimadzu and specific injectors like CTC PAL.Hybrid MS-MS. Mass accuracy: 5 ppm over m/z 150-900. In V-mode 10000 resolution; in W mode 20000 .MicromassQ-TOF-Ultima GLOBALquadrupool-vluchtijd hybrideExceeding 20000Z-spray; ESI, APcI Nanoflow Picospray en CE-MS interfaces, LockSprayMassLynx 4.0 (Windows XP, NT or Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated couplings to: pd-quest, ACD, nugenesisMicomass CapLC, Waters CapLC,Waters Alliance,Waters 600, Waters Breeze, Agilent 1050, 1090, 1100, JASCO, Gilson, Shimadzu and specific injectors like CTC PAL.Hybrid MS-MS. Mass accuracy: 5 ppm over m/z 150-900. In V-mode 10000 resolution; in W mode 17500 . Maldi-optionMicromassAutoSpecSectorvanaf 3000ESI, APCIMassLynx 4.0 (Windows XP, NT or Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated couplings to: pd-quest, ACD, nugenesisMicomass CapLC, Waters CapLC,Waters Alliance,Waters 600, Waters Breeze, Agilent 1050, 1090, 1100, JASCO, Gilson, Shimadzu and specific injectors like CTC PAL.Resolution 60000 (20% valley)ShimadzuQP-8000 alphasingle-quadrupole1500-2000ESI, APCILCMS solutions (windows NT, 2000) Shimadzu LC-10Avp, integrated systemVery robust system for routine analyses.ShimadzuLCMS2010 prepSTARsingle-quadrupole with Q-array technology2000ESI, APCILCMS solutions (windows NT, 2000) & Psiport MS datamanagement Shimadzu LC-8A, integrated system with optional Gilson 215 controlFlow rates: 0,1 to 150 ml/min, Mass Triggered fraction collector with sample tracking and PsiShimadzuLCMS 2010single-quadrupole with Q-array technology2000ESI, APCILCMS solutions (windows NT, 2000) & Psi port MS datamanagement Shimadzu LC-10Avp, integrated system with SILHT high throughput autosamplerpatented optical design; QoQ= Q-array (Tapered triple quadruplate), optical lens, Quadrupole.Thermo FinniganMSQSingle-quadrupole2000ESI, APCI (aQa-bron)Xcalibur (Windows 2000)TSP, Agilent and Waters (also LC-Packings, Spark, Gilson en CTC)Thermo FinniganLCQ Advantage and DecaXPIon-trap2000 (Advantage); 4000 (DecaXP)ESI, APCI, APPI, MALDI, Nano-ESIXcalibur (Windows 2000)TSP, Agilent and Waters (also LC-Packings, Spark, Gilson en CTC)MS-MS or optinal MS-MSn (Advantage) or MS-MSn (DecaXP)Thermo FinniganTSQTriple- quadrupole (TSQ)4000ESI, APCI, Nano-ESIXcalibur (Windows 2000)TSP, Agilent and Waters (also LC-Packings, Spark, Gilson en CTC)Also GC-MS, Solids-probe option and FAB; MS-MSThermo FinniganTSQ-QuantumTriple- quadrupole (TSQ)1500ESI, APCIXcalibur (Windows 2000)TSP, Agilent and Waters (also LC-Packings, Spark, Gilson en CTC)high resolution at Q1 and Q3, accurate mass optionThermo FinniganMAT95 XP LC-MSMagnetic sector (BE)At maximum acceleration: 3500 DaESI, APCI, Nano-ESIXcalibur (Windows 2000)TSP, Agilent and Waters (also LC-Packings, Spark, Gilson en CTC)Options:GC-MS, DIP and DCI probe, FAB, FD/FI, EI/CI, Ion-Trap for MS/MS (LCQ Deca XP)Thermo FinniganMAT900 XL LC-MSMagnetic sector (EB)Ar maximum acceleration: 5000 DaESI, APCI, Nano-ESIXcalibur (Windows 2000)TSP, Agilent and Waters (also LC-Packings, Spark, Gilson en CTC)Options:GC-MS, DIP and DCI probe, FAB, FD/FI, EI/CI, Ion-Trap for MS/MS (LCQ Deca XP) and Patric detectorThermo FinniganFTMS ( FT-IC

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论