免费预览已结束,剩余7页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
大连交通大学2009届本科生毕业设计外文翻译 Controlling the Furnace Process in Coal-Fired BoilersThe unstable trends that exist in the market of fuel supplied to thermal power plants and the situations in which the parameters of their operation need to be changed (or preserved), as well as the tendency toward the economical and environmental requirements placed on them becoming more stringent, are factors that make the problem of controlling the combustion and heat transfer processes in furnace devices very urgent. The solution to this problem has two aspects. The first involves development of a combustion technology and,accordingly, the design of a furnace device when new installations are designed. The second involves modernization of already existing equipment. In both cases,the technical solutions being adopted must be properly substantiated with the use of both experimental and calculationstudies.The experience Central Boiler-Turbine Institute Research and Production Association (TsKTI) and ZiO specialists gained from operation of boilers and experimental investigations they carried out on models allowed them to propose several new designs of multifuel and maneuverablein other words, controllablefurnace devices that had been put in operation at power stations for several years. Along with this, an approximate zero-one-dimensional, zonewise calculation model of the furnace process in boilers had been developed at the TsKTI, which allowed TsKTI specialists to carry out engineering calculations of the main parameters of this process and calculate studies of furnaces employing different technologies of firing and combustion modes .Naturally, furnace process adjustment methods like changing the air excess factor, stack gas recirculation fraction, and distribution of fuel and air among the tiers of burners, as well as other operations written in the boiler operational chart, are used during boiler operation.However, the effect they have on the process is limited in nature. On the other hand, control of the furnace process in a boiler implies the possibility of making substantial changes in the conditions under which the combustion and heat transfer proceed in order to considerably expand the range of loads, minimize heat losses, reduce the extent to which the furnace is contaminated with slag, decrease the emissions of harmful substances, and shift to another fuel. Such a control can be obtained by making use of the following three main factors:(i) the flows of oxidizer and gases being set to move in the flame in a desired aerodynamic manner;(ii) the method used to supply fuel into the furnace and the place at which it is admitted thereto;(iii) the fineness to which the fuel is milled.The latter case implies that a flame-bed method is used along with the flame method for combusting fuel.The bed combustion method can be implemented in three design versions: mechanical grates with a dense bed, fluidized-bed furnaces, and spouted-bed furnaces.As will be shown below, the first factor can be made to work by setting up bulky vortices transferring large volumes of air and combustion products across and along the furnace device. If fuel is fired in a flame, the optimal method of feeding it to the furnace is to admit it to the zones near the centers of circulating vortices, a situation especially typical of highly intense furnace devices. The combustion process in these zones features a low air excess factor ( 1) and a long local time for which the components dwell in them, factors that help make the combustion process more stable and reduce the emission of nitrogen oxides .Also important for the control of a furnace process when solid fuel is fired is the fineness to which it is milled; if we wish to minimize incomplete combustion, the degree to which fuel is milled should be harmonized with the location at which the fuel is admitted into the furnace and the method for supplying it there, for the occurrence of unburned carbon may be due not only to incomplete combustion of large-size fuel fractions, but also due to fine ones failing to ignite (especially when the content of volatiles Vdaf 20%).Owing to the possibility of pictorially demonstrating the motion of flows, furnace aerodynamics is attracting a great deal of attention of researchers and designers who develop and improve furnace devices. At the same time, furnace aerodynamics lies at the heart of mixing (mass transfer), a process the quantitative parameters of which can be estimated only indirectly or by special measurements. The quality with which components are mixed in the furnace chamber proper depends on the number, layout, and momenta of the jets flowing out from individual burners or nozzles, as well as on their interaction with the flow of flue gases, with one another, or with the wall.It was suggested that the gas-jet throw distance be used as a parameter determining the degree to which fuel is mixed with air in the gas burner channel. Such an approach to estimating how efficient the mixing is may to a certain degree be used in analyzing the furnace as a mixing apparatus. Obviously, the greater the jet length (and its momentum), the longer the time during which the velocity gradient it creates in the furnace will persist there, a parameter that determines how completely the flows are mixed in it. Note that the higher the degree to which a jet is turbulized at the outlet from a nozzle or burner, the shorter the distance which it covers, and, accordingly, the less completely the components are mixed in the furnace volume. Once through burners have advantages over swirl ones in this respect.It is was proposed that the extent to which once through jets are mixed as they penetrate with velocity w2 and density 2 into a transverse (drift) flow moving with velocity w1 and having density 1 be correlated with the relative jet throw distance in the following wayWhere ks is a proportionality factor that depends on the “pitch” between the jet axes (ks= 1.51.8).The results of an experimental investigation inwhich the mixing of gas with air in a burner and then in a furnace was studied using the incompleteness of mixing as a parameter are reported in 5.A round once through jet is intensively mixed with the surrounding medium in a furnace within its initial section, where the flow velocity at the jet axis is still equal to the velocity w2 at the nozzle orifice of radius r0.The velocity of the jet blown into the furnace drops very rapidly beyond the confines of the initial section, and the axis it has in the case of wall-mounted burners bends toward the outlet from the furnace.One may consider that there are three theoretical models for analyzing the mixing of jets with flowrate G2 that enter into a stream with flowrate G1. The first model is for the case when jets flow into a “free” space (G1= 0),the second model is for the case when jets flow into a transverse (drift) current with flowrate G1G2,and the third model is for the case when jets flow into a drift stream with flowrate G1G2. The second model represents mixing in the channel of a gas burner, and the third model represents mixing in a furnace chamber. We assume that the mixing pattern we have in a furnace is closer to the first model than it is to the second one, since 0 G1/G2 1, and we will assume that the throw distance h of the jet being drifted is equal to the length S0 of the “free” jets initial section. The ejection ability of the jet being drifted then remains the same as that of the “free” jet, and the length of the initial section can be determined using the well-known empirical formula of G.N. Abramovich 6 :S0= 0.67r0/a, (2)where a is the jet structure factor and r0 is the nozzle radius.At a = 0.07, the length of the round jets initial section is equal to 10 r0 and the radius the jet has at the transition section (at the end of the initial section) is equal to 3.3 r0. The mass flowrate in the jet is doubled in this case. The corresponding minimum furnace cross-sectional area Ff for a round once through burner with the outlet cross-sectional area Fb will then be equal to and the ratio Ff/Fb20. This value is close to the actual values found in furnaces equipped with once through burners. In furnaces equipped with swirl burners, a= 0.14 and Ff/Fb10. In both cases, the interval between the burners is equal to the jet diameter in the transition section d tr , which differs little from the value that has been established in practice and recommended in 7.The method traditionally used to control the furnace process in large boilers consists of equipping them with a large number of burners arranged in several tiers. Obviously, if the distance between the tiers is relatively small, operations on disconnecting or connecting them affect the entire process only slightly. A furnace design employing large flat-flame burners equipped with means for controlling the flame core position using the aerodynamic principle is a step forward. Additional possibilities for controlling the process in TPE-214 and TPE-215 boilers with a steam output of 670 t/h were obtained through the use of flat-flame burners arranged in two tiers with a large distance between the tiers; this made it possible not only to raise or lower the flame, but also to concentrate or disperse the release of heat in it 1. A very tangible effect was obtained from installing multifuel (operating on coal and open-hearth, coke, and natural gases) flat-flame burners in the boilers of cogeneration stations at metallurgical plants in Ukraine and Russia.Unfortunately, we have to state that, even at present, those in charge of selecting the type, quantity, and layout of burners in a furnace sometimes adopt technical solutions that are far from being optimal. This problem should therefore be considered in more detail. If we increase the number of burners nb in a furnace while retaining their total cross-sectional area (Fb=idem) and the total flowrate of air through them, their equivalent diameters deq will become smaller, as willthe jet momentums Gbwb, resulting in a corresponding decrease in the jet throw distance hb and the mass they eject. The space with high velocity gradients also becomes smaller, resulting in poorer mixing in the furnace as a whole. This factor becomes especially important when the emissions of NOx and CO are suppressed right inside the furnace using staged combustion (at b 1) under the conditions of a fortiori nonuniform distribution of fuel among the burners.In 1, a quantitative relationship was established between the parameters characterizing the quality with which once through jets mix with one another as they flow into a limited space with the geometrical parameter of concentration = with nb = idem and Gb = idem. By decreasing this parameter we improve the mass transfer in the furnace; however, this entails an increase in the flow velocity and the expenditure of energy (pressure drop) in the burners with the same Fb. At the same time, we know from experience and calculations that good mixing in a furnace can be obtained without increasing the head loss if we resort to large long-range jets. This allows a much less stringent requirement to be placed on the degree of uniformity with which fuel must be distributed among the burners. Moreover, fuel may in this case be fed to the furnace location where it is required from process control considerations.For illustration purposes, we will estimate the effect the number of burners has on the mixing in a furnace at = = idem. schematically shows the plan views of two furnace chambers differing in the number of once through round nozzles (two and four) placed in a tier (on one side of the furnace). The furnaces have the same total outlet cross-sectional areas of the nozzles (Fb) and the same jet velocities related to these areas (wb). The well-known swirl furnace of the TsKTI has a design close to the furnace arrangement under consideration. According to the data of 1, the air fraction air that characterizes the mixing and enters through once through burners into the furnace volume beneath them can be estimated using the formula air = 1 (3) which has been verified in the range = 0.030.06 for a furnace chamber equipped with two frontal once through burners. Obviously, if we increase the number of burners by a factor of 2, their equivalent diameter, the length of the initial section of jets S0 and the area they “serve” will reduce by a factor of Then, for example, at = 0.05, the fraction air will decrease from 0.75 to 0.65. Thus, Eq. (3) may be written in the following form for approximately assessing the effect of once through burners on the quality of mixing in a furnace:air = 1 3.5f nb ,where is the number of burners (or air nozzles) on one wall when they are arranged in one tier both in onesided and opposite manners.The number of burners may be tentatively related to the furnace depth af (at the same = idem) using the expression (5)It should be noted that the axes of two large opposite air nozzles ( = 1)an arrangement implemented in an inverted furnacehad to be inclined downward by more than 50 8.One well-known example of a furnace device in which once through jets are used to create a large vortex covering a considerable part of its volume is a furnace with tangentially arranged burners. Such furnaces have received especially wide use in combination with pulverizing fans. However, burners with channels having a small equivalent diameter are frequently used for firing low-calorific brown coals with high content of moisture. As a result, the jets of air-dust mixture and secondary air that go out from their channels at different velocities(w2/w1 = 23) become turbulized and lose the ability to be thrown a long distance; as a consequence, the flame comes closer to the waterwalls and the latter are contaminated with slag. One method by which the tangential combustion scheme can be improved consists of organizing the so-called concentric admission of large jets of air-dust mixture and secondary air with the fuel and air nozzles spaced apart from one another over the furnace perimeter, accompanied by intensifying the ventilation of mills 9, 10. Despite the fact that thetemperature level in the flame decreases, the combustion does not become less stable because the fuel mixes with air in a stepwise manner in a horizontal plane.Vortex furnace designs with large vortices the rotation axes of which are arranged transversely with respect to the main direction of gas flow have wide possibilities in terms of controlling the furnace process. In 1, four furnace schemes with a controllable flame are described, which employ the principle of large jets colliding with one another; three of these schemes have been implemented. A boiler with a steam capacity of 230 t/h has been retrofitted in accordance with one of these schemes (with an inverted furnace) . Tests of this boiler, during which air-dust mixture was fed at a velocity of 2530 m/s from the boiler front using a highconcentration dust system, showed that the temperature of gases at the outlet from the furnace had a fairly uniform distribution both along the furnace width and depth . A simple method of shifting the flame core over the furnace height was checked during the operation of this boiler, which consisted of changing the ratio of air flowrates through the front and rear nozzles;this allowed a shift to be made from running the furnace in a dry-bottom mode to a slag-tap mode and vice versa. A bottom-blast furnace scheme has received rather wide use in boilers equipped with different types of burners and mills. Boilers with steam capacities ranging from 50 to 1650 t/h with such an aerodynamic scheme of furnaces manufactured by ZiO and Sibenergomash have been installed at a few power stations in Russia and abroad . We have to point out that, so far as the efficiency of furnace process control is concerned, a combination of the following two aerodynamic schemes is of special interest: the inverted scheme and the bottom-blast one. The flow pattern and a calculation analysis of the furnace process in such a furnace during the combustion of lean coal are presented in 13.Below, two other techniques for controlling the furnace process are considered. Boilers with flamestoker furnaces have gained acceptance in industrial power engineering, devices that can be regarded to certain degree as controllable ones owing to the presence of two zones in them . Very different kinds of fuel can be jointly combusted in these furnaces rather easily. An example of calculating such a furnace device is given in 2. As for boilers of larger capacity, work on developing controllable two-zone furnaces is progressing slowly . The development of a furnace device using the so-called VIR technology (the transliterated abbreviation of the Russian introduction, innovation, and retrofitting) can be considered as holding promise in this respect. Those involved in bringing this technology to the state of industry standard encountered difficulties of an operational nature (the control of the process also presented certain difficulties). In our opinion, these difficulties are due to the fact that the distribution of fuel over fractions can be optimized to a limited extent and that the flow in the main furnace volume has a rather sluggish aerodynamic structure. It should also be noted that the device for firing the coarsest fractions of solid fuel in a spouting bed under the cold funnel is far from being technically perfect.Centrifugal dust concentrators have received acceptance for firing high-reactive coals in schemes employing pulverizing fans to optimize the distribution of fuel as to its flowrate and fractions. The design of one such device is s
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026年第十四师昆玉市南园二街消防救援站第三批次招聘编制外政府专职消防员(1人)笔试参考题库及答案详解
- 2026年江西省职工保障互助会秘书处招聘工作人员4人告笔试模拟试题及答案详解
- 2026中交一公局(海南)建设有限公司招聘2人笔试备考题库及答案详解
- 2026年乾安县事业单位专项招聘普通高校毕业生笔试参考题库及答案详解
- 2026年河南省三门峡市招聘乡村振兴村级协理员280人笔试参考题库及答案详解
- 2026广西河池市环江毛南族自治县洛阳镇人民政府招聘专职禁毒社工1人笔试备考试题及答案详解
- 2026福建福州城市客运场站运营有限公司(第一批)招聘1人笔试模拟试题及答案详解
- 2026陕西特岗教师招聘(计划招录383人)笔试模拟试题及答案详解
- 2026四川成都市龙泉驿区青台山幼儿园招聘笔试备考试题及答案详解
- 2026安徽皖信人力资源管理有限公司招聘机场安检辅检员(劳务派遣)笔试备考题库及答案详解
- 2026年传播与策划考试试题及答案答案
- 小学劝返复学工作制度
- 2026年部编版五年级语文下册金句仿写
- 2025陕煤电力略阳有限公司高校毕业生招聘10人笔试历年典型考点题库附带答案详解
- 藏医外冶室工作制度
- 2025年铜仁市辅警考试公安基础知识考试真题库及参考答案
- 日本本田奖惩制度
- 2025年湖南省高中学业水平合格性考试英语卷试题(含答案)
- 紧固件模具维护调试技师岗位招聘考试试卷及答案
- 2026年安全生产月公开课:人人讲安全 个个会应急查找身边安全隐患
- 院前急救与院内救治应急演练方案(绕急诊)
评论
0/150
提交评论