




免费预览已结束,剩余36页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
ZXME-MMSC 多媒体消息中心-EMC存储安装配置使用手册ZXME-MMSC 多媒体消息中心-EMC存储安装配置使用手册目 录1 硬件安装实施01.1设备上架01.2设置DAE的地址01.3连接设备电源线以及LCC CABLE01.4设备加电11.5交换机的安装11.6连接光纤21.7将CX300连接到客户网络中,并配置CX300 SPA&SPB的IP地址21.8存储初始化21.9存储flarecode 升级51.10存储内存设置81.11Enabling Access Control91.12创建RAID组91.13Bind Luns102 软件安装实施102.1检查主机系统环境102.1.1Solaris112.2安装HBA卡122.2.1Windows122.2.2Linux142.2.3Solaris182.3安装PowerPath192.3.1Windows下PowerPath的安装202.3.2Linux下PowerPath的安装与配置202.3.3Solaris下PowerPath的安装与配置212.4安装Navisphere Agent232.4.1Windows下Host Agent和Navisphere CLI的安装与配置231.13.1Linux下Host Agent和Navisphere CLI的安装与配置262.4.2Solaris下Host Agent和Navisphere CLI的安装与配置272.5光纤连接292.5.1Direct attach292.5.2Cable HBAs to switch ports292.5.3Zone configure302.6Register the HBA(s) with the array312.6.1Make target SPs available312.6.2Register the HBA(s) with the array322.6.3Set failover settings for PowerPath332.7Create LUNs on RAID groups with Navisphere Manager332.8Create storage groups and connect hosts332.9Allow server to see target LUNs352.9.1Windows352.9.2Solaris352.9.3Linux362.10测试PowerPath362.11收集系统环境配置信息37第37页1 硬件安装实施1.1 设备上架EMC设备机柜为其他厂商制造,故此处的上架安装参见机柜的硬件安装指导(P/N 014003029) 1.2 设置DAE的地址为所有DAE2 磁盘设置封装地址. 参见手册。 第一块 DAE 设置为 EA 1. 第二块 DAE 应为 EA 2 第三块为 EA 3. EMC推荐安装最新的EMCApproved HBA Firmware、Fcode/BIOS、Driver。1.3 连接设备电源线以及LCC CABLE如图连接LCC CABLE:如图连接电源线及SPS cable:1.4 设备加电1.5 交换机的安装关于BOROCADE 交换机安装请查考以下手册:l Departmental Switch Model DS-16B Hardware Reference Manual (P/N 014-002999)l Departmental Switch Model DS-8B Hardware Reference Manual (P/N 014002998)l Connectrix B Series DS-8B3 and DS-16B3 Version 4.2 Hardware Reference Manual (P/N 300-001-703)l Connectrix B Series DS-4100B Version 4.4 Hardware Reference Manual (P/N 300-002-191)1.6 连接光纤l 如果客户使用直连,用光纤连接SP的端口和主机HBA卡端口。l 如果客户使用光纤交换机,连接SP端口和交换机,连接主机HBA卡到交换机1.7 将CX300连接到客户网络中,并配置CX300 SPA&SPB的IP地址1.8 存储初始化1. 使用NULL modem线连接笔记本电脑串口(COM 1) 及存储SP的串口l Windows 2000 环境下1) 打开笔记本电脑,点击开始 设置 拨号和网络连接. 设置拨号网络时输入连接名2) 在连接对话框, 输入用户名 clariion 密码clariion!3) 点击 连接-完成l Windows NT 环境下1) 打开电脑,选择我的电脑 拨号网络. 设置拨号网络时输入连接名2) 点击 拨号3) 输入用户名 clariion密码 clariion!. 忽略 Domain.4) 点击 完成.2. 打开浏览器,输入 /setup.存储处理器网络配置,参见下图 .3. SP A配置:l IP 地址l 主机名l 掩码l SP A网关地址l SP B Peer IP地址 l 如希望确保安全, 设置管理端口号为 2162/2163.所有步骤结束后,对SPB重复以上步骤。1.9 存储flarecode 升级使用IE 登陆到存储上:右键点击存储,选择SOFTWARE OPERATIONS SOFTWARE INSTALLATION WIZARD升级结束后,需要commit新的版本,如上图所示.1.10 存储内存设置设置SP CACHE,如下图所示:1.11 Enabling Access Control1.12 创建RAID组根据CCPF 创建 raid 组,划分lun, 创建存储组, 分配 luns 给主机. 1.13 Bind Luns2 软件安装实施以下描述了在Solaris、SuSE Linux和windows操作系统上安装NaviAgent、powerpath软件的方法和步骤,以及在Solaris和Windows操作系统下连接EMC CX300的方法和步骤。2.1检查主机系统环境在安装之前,需要按照EMC Support Matrix 检查host environment,需要检查的内容有:l OS Version & Patch l OS configurationl HBA Firmware、Fcode/BIOS、Driver version对于不满足EMC Support Matrix的地方,需要主机工程师安装或升级到相应的版本。具体要求请查看文件:Support Matrix-ZTEr-2007-07-29.pdf。2.1.1Solaris1 操作系统版本及补丁通过cat /etc/release来查看Solaris的版本号;showrev p|grep patch id 来检查系统补丁。EMC 需要的solaris 10 下的SUN补丁:l 118833-36 SunOS 5.10: Kernel patchl 125100-09 SunOS 5.10: Kernel patchl 119130-33 SunOS 5.10: Sun Fibre Channel Device Drivers (only necessary for Leadville Stack driver)l 125184-03 SunOS 5.10: Sun Fibre Channel Device Drivers.l 120222-20 SunOS 5.10: Emulex-Sun LightPulse fibre channel adapter driver v2.20j (only requred for Emulex HBAs running Leadville)l 125166-02 SunOS 5.10: Qlogic ISP fibre channel device driver v2.19 (only required for Qlogic HBAs running Leadville)l 122640-05 SunOS 5.10: zfs genesis patch (require for zfs)l 120473-11 SunOS 5.10: lib nss ldap PAM zfs patch (require for zfs)l 119090-24 SunOS 5.10: iSCSI device driver and utilitiesEMC需要的solaris 9 下的SUN补丁:l 112233-12 SunOS 5.9: kernel patchl 117171-17 SunOS 5.9: kernel patchl 118558-39 SunOS 5.9: kernel patchl 122300-08 SunOS 5.9: Kernel patchl 112834-06 SunOS 5.9: patch SCSIl 113277-52 SunOS 5.9: sd and ssd patch2 HBA Firmware、Fcode/BIOS、Driver version本系统采用的SGXPCI1FCQL2为SUN-branded qlogic HBA,建议采用SUN SFS based driver,在SFS based driver下,HBA的firmware是在加载driver的时候一起加载的,不是 user serviceable,所以只需要检查HBA Driver version即可。对于solaris9,SFS 需要单独安装,EMC支持的版本有:l SAN 4.4.1024,l SAN 4.4.1124,l SAN 4.4.1224,如果还没有安装SFS,请参见下一节对于Solaris 10,SFS已经集成到操作系统,只需要打上前面提到的补丁即可。2.2安装HBA卡EMC推荐安装最新的EMCApproved HBA Firmware、Fcode/BIOS、Driver。2.2.1Windows相关驱动下载对于本系统采用的QLE2460(如果不是该型号的HBA卡,请下载对应的文件!) HBA卡,可以在Qlogic的网站上下载最新的HBA Firmware、Fcode/BIOS、Driver:l EMC CLARiiON and EMC Symmetrix approved common Flash Image:/boot_code/55013/qle2460cf1.56risc4.00.26.zipl EMC CLARiiON and EMC Symmetrix approved common WIN 2003 STORPort 32-bit (x86) driver:/drivers/54852/e2xxxw32Storv91415.zipl SANsurfer Install Wizard for Windows/drivers/56991/qlflzip_1_4_31_B1.exel SANsurfer FC HBA Manager for Window/drivers/55191/emc_sansurfer5.0.0b17_windows_install.exe要下载Qlogic其他型号HBA的EMCApproved Driver:1 打开 .2 选择页面左边的Downloads连接.出现 Driver Downloads / Manuals页面。3 选择 OEM MODELS下的EMC;出现EMC Approved Software页面。4 选择EMC SYMMETRIX, CLARiiON & CELERRA supported software.5 在页面下方选择你需要的HBA 型号,例如: QLA2462-E, 下载 SANsurfer Install Wizard for Windows。安装 HBA driver and software utilities对于windows2003,EMC推荐使用STORPort drivers。在安装STORPort drivers之前,需要安装Microsoft QFE hotfix Q932755(注意Q932755需要windows 2003 SP1 或者 Windows 2003 R2,如果是non-SP1 servers and CLARiiON Storage Arrays,请安装 Microsoft STORPort hotfix Q908980);下载地址请参见:/default.aspx?scid=kb;LN;93275Driver installation/ upgrade在qlogic网站下载最新的SANsurfer Install Wizard for Windows(当前最新版本为1.4.31 Build 1,包含0 SCSI miniport, 5 IA32 STOR minport, and 5 X64 STOR drivers),运行SANsurfer Install Wizard for Windows,根据向导提示完成Driver installation/upgrade。SANsurfer FC HBA Manager在qlogic网站下载最新的SANsurfer FC HBA Manager(当前最新版本为5.0.0b17)并安装,可以通过该软件对HBA卡进行管理和配置EMC powerpath要求连接同一LUN/Volume的HBA的型号、firmware和配置要一致,请通过SANsurfer FC HBA Manager或者在主机重启的时候查看HBA卡的BIOS version:如果连接同一LUN/Volume的HBA的firmware不一致,请通过SANsurfer FC HBA Manager升级firmware到同一版本。2.2.2Linux相关驱动下载对于本系统采用的QLE2460 HBA卡(如果不是该型号的HBA卡,请下载对应的文件!),可以在Qlogic的网站上下载最新的HBA Firmware、Fcode/BIOS、Driver:l EMC CLARiiON and EMC Symmetrix approved common Flash Image:/boot_code/55013/qle2460cf1.56risc4.00.26.zipl SANsurfer CLI for Linux (I386 platforms):/drivers/58375/scli-1.7.0-13.i386.rpm.gzl SANsurfer FC HBA Manager for Linux/drivers/58377/emc_sansurfer5.0.0b19_linux_install.bin.gz要下载Qlogic其他型号HBA的EMCApproved Driver:6 打开 .7 选择页面左边的Downloads连接.出现 Driver Downloads / Manuals页面。8 选择 OEM MODELS下的EMC;出现EMC Approved Software页面。9 选择EMC SYMMETRIX, CLARiiON & CELERRA supported software.10 在页面下方选择你需要的HBA 型号,例如: QLA2462-E, 下载 对应的驱动。安装HBA 驱动与应用软件对于SLES 9 SP3,操作系统已经包含了EMC 推荐的驱动版本8.01.02-sles;SLES10操作系统已经包含了EMC 推荐的驱动版本8.01.04-k;SLES10 SP1操作系统已经包含了EMC 推荐的驱动版本8.01.04-k;所以不需要再单独安装Qlogic的driver。注:PowerPath5.0.0最低要求安装SLES9 SP3,所以请升级操作系统至该版本。安装SANsurfer FC HBA Manager在qlogic网站下载最新的SANsurfer FC HBA Manager(当前最新版本为5.0.0b19)并安装,可以通过该软件对HBA卡进行管理和配置EMC powerpath要求连接同一LUN/Volume的HBA的型号、firmware和配置要一致,请通过SANsurfer FC HBA Manager或者在主机重启的时候查看HBA卡的BIOS version(以QLA2340为例):如果连接同一LUN/Volume的HBA的firmware不一致,请通过SANsurfer FC HBA Manager升级firmware到同一版本。注:EMC建议将QLE2460的BIOS升级到1.24。如果不满主以上条件,请选择一下方法之一升级BIOS:升级 QLogic HBA BIOS (if necessary):升级HBA BIOS的方法有以下几种: QLogic SANsurfer QLogic SANsurferCLI NVRAM file on a DOS-bootable diskette使用QLogic SANsurfer: SANsurfer GUI 可以从的 EMC-approved 部分 下载. 点击屏幕左边Downloads.OEM Models模式下点击EMC连接. 进入下一页, 选择 EMC SYMMETRIX, CLARiiON, & CELERRA supported software. 在 Product 表格项选择HBA模板. 再下一个表格里, 查找正确的SANsurfer 文件点击关联的 Download 链接.使用SANsurfer升级BIOS,参照 QLogic 在其网站提供的细节文档。使用GUI向导, 在终端窗口运行以下命令:/opt/QLogic_Corporation/SANsurfer/SANsurfer &注意: 当QLogic 4 GB HBAs 升级 BIOS, QLogic SANsurfer GUI的最低版本是2.0.30b52.使用QLogic SANsurferCLI:SANsurferCLI (scli) 通过安装包或者从官方网站下载。 使用SANsurferCLI方式升级BIOS, 参见QLogic 在其公司网站提供的细节指导文档。运行以下命令:/opt/QLogic_Corporation/SANsurferCLI/scli注意: 当QLogic 4 GB HBAs升级BIOS, QLogic SANsurfer CLI 所需要的最低版本为1.06.16 build 23.使用NVRAM file on a DOS-bootable diskette: a. 获取BIOS的最新版从 . 点击屏幕左边的Downloads .在OEM 模板下点击EMC连接. 下一页,选取EMC SYMMETRIX, CLARiiON, & CELERRA supported software. 在 Product 表格选择 HBA model. 进入下一页, 找到正确的BIOS 文件点击关联的 Download链接.b. 文件类型为zip自解压,运行在 Windows 9x 操作系统机器下. 打开DOS窗口运行入下命令format /s a:载DOS下, 将解压缩文件拷入软盘.c. 确认 QLogic HBA(s) 已经在主机安装.d. 将BIOS升级软盘插入电脑.e. Reboot the host.f. 重启主机以后, a DOS prompt appears. Type flasutil /L /F and press Enter.NOTE: HBA BIOS 升级需要几分钟时间。g. 升级结束,取出软盘重启主机. 启动时, QLogic banner 应当显示所需 BIOS版本信息.EMC recommended NVRAM settings for Linux请按照Using the NVRAM file on a DOS-bootable diskette中提到的方法制作Qlogic BIOS升级软盘,在第f步的时候运行: eqle2460.bat即可。Configure Driver parameters编辑/etc/modprobe.conf.local:vi /etc/modprobe.conf.local加入以下内容:options qla2xxx ConfigRequired=0 ql2xfailover=0编辑/etc/sysconfig/kernel, vi /etc/sysconfig/kernel在INITRD_MODULES行上加入qla2xxx:INITRD_MODULES=reiserfs qla2xxx_conf qla2xxx重新生成ramdisk文件,使配置生效:cd /bootmkinitrd -k vmlinuz-$1 -i initrd-$1where $1 is the v2.6.x kernel version currently running.you can get it use uname -aExample:cd /bootmkinitrd -k vmlinuz- 2.6.5-7.244-smp -i initrd-2.6.5-7.244-smp2.2.3Solaris在solaris主机下安装新的 QLogic HBA 驱动本系统采用的SGXPCI1FCQL2为SUN-branded qlogic HBA,建议采用SUN SFS based driver。 SFS已经集成到Solaris10,Solaris9 需要从SUN网站下载单独安装:1 Go to /download/index.jsp?tab=2, scroll down and click on StorageTek SAN 4.4.2 Log in with your user name and password, and accept the license agreement.3 Select and download Install_It Script SAN 4.4.x, English.4 Select and download Install_it Script SAN 4.4.x Readme, English, and follow its instructions.Configure the QLogic HBA driver for failover support for Solaris1 在编辑当前 qc.conf 配置文件之前, 使用以下命令备份:cp /kernel/drv/qlc.conf /kernel/drv/qlc.conf.bak2 配置文件 (qlc.conf)在安装SFS driver的时候自动创建. 请根据下表调整配置。VariableDefault ValueRecommended Settings for CLARiiONhba0-max-frame-length1024 bytes2048 byteshba0-execution-throttle1620hba0-login-retry-count88hba0-enable-adapter-hard-loop-ID0 (disable) FC-AL: 1 (enable) FC-SW: N/Ahba0-adapter-hard-loop-ID0 FC-AL: 125 (see note A below) FC-SW: N/Ahba0-enable-LIP-reset0 (disable)0 (disable)hba0-enable-LIP-full-login1 (enable)1 (enable)hba0-enable-target-reset0 (disable)0 (disable)hba0-reset-delay5 (sec)5 (sec)hba0-port-down-retry-count88hba0-maximum-luns-per-target8N/Ahba0-connetion-options2 FC-AL: 0 FC-SW: 1hba0-fc-tape1 (enable)0 (disable)hba0-pci-latency-timer0x400x40hba0-link-down-error1 (enable)1 (enable)hba0-link-down-timeout60 (sec)60 (sec)hba0-fast-error-reporting01 (enable)hba0-extended-logging00 (disable)hba0-queue-full-retry-count1616hba0-queue-full-retry-delay22hba0-FDMI-support00NOTE A: In a hub environment, the hard loop ID for each HBA must be unique.编辑 Solaris /etc/system 文件1 备份当前/etc/system文件,在/etc/system文件后面增加如下内容:forceload: drv/ssd set fcp:ssfcp_enable_auto_configuration=1 set ssd:ssd_max_throttle=20 set ssd:ssd_io_time=0x3c2 保存修改,重启主机reboot - -r注:对/etc/system的修改在操作系统重启才会生效。2.3安装PowerPathWindows安装powerpath 5.0.0,Solaris还需要安装PowerPath Patch Version 5.0.1 for Solaris。请从powerlink下载或者向EMC工程师索取。2.3.1Windows下PowerPath的安装1 插入PowerPathCD,如果自动运行开启,则会自动运行安装程序,如果自动运行未开启,则手动运行安装程序,进入安装界面。2 在运行界面,选择或输入PowerPath安装程序名然后点击OK。3 在语言选择界面,在下拉框中选择安装的语言,点击OK。4 在自动安装程序进入界面,点击Next。5 在CLARiiON AX-series界面,如果主机只同CLARiiON AX-series连接,直接点击Next,否则点击No然后点击Next。6 在用户信息界面中输入您的姓名、机构然后点击Next。7 在用户启动界面上配置PowerPath对Invista设备和第三方阵列的支持,并设置PowerPath的安装目录(EMC建议将PowerPath安装在默认路径)。8 如果您希望PowerPath支持Invista设备,没有第三方阵列,PowerPath安装在默认路径(推荐),直接点击Next。9 PowerPath默认启动支持Invista设备,如果主机没有与Invista系统连接,在下拉菜单中选择“This feature will not be available”。10 如果您希望在第三方阵列上使用PowerPath,在下拉菜单中选择“This feature will be installed on local hard drive”您可以选择多种阵列类型。11 如果您需要将PowerPath安装在不同的目录,点击“Change”,选择您要安装的目录,点击OK。12 在准备安装界面,点击Install。13 如果您没有注册过license,将会弹出EMC Licensing Tool对话框。输入您的24位注册码,点击Add,然后点击OK。14 点击Finish完成安装。15 重新启动服务器。2.3.2Linux下PowerPath的安装与配置1. 用root账号登录,在CD-ROM中插入PowerPath安装CD。2. 输入以下命令创建/cdrom目录作为mount point mkdir /cdrom 将CD mount到 /cdrom,输入: mount /dev/cdrom /cdrom3. 进入LINUX目录,输入 cd /cdrom/LINUX4. 安装PowerPath,输入rpm -i EMCpower.LINUX-5.0.0-.rpm 其中,build代表PowerPath版本号, 代表:Package Name Descriptionsles.x86_64 PowerPath 5.0.x on SLES 9 x86_64 platforms.sles10.x86_4 PowerPath 5.0.x on SLES 10 x86_64 platforms.sles.ia64 PowerPath 5.0.x on SLES 9 IA64 platforms.sles10.ia64 PowerPath 5.0.x on SLES 10 IA64 platforms.sles.i386 PowerPath 5.0.x on SLES 9 386 platforms.sles10.i386 PowerPath 5.0.x on SLES 10 386 platforms.rhel.x86_64 PowerPath 5.0.x on RHEL and Asianux x86_64 platforms.rhel.ia64 PowerPath 5.0.x on RHEL IA64 platforms.rhel.i386 PowerPath 5.0.x on RHEL and Asianux i386 platforms.例如SLES 9(32bit)请安装:EMCpower.LINUX-5.0.0-157.sles.i386.rpm5. 安装完毕后,输入以下命令来输入License Key:/etc/emcpreg install单击“y”输入License Key6. 重新启动PowerPath:7. 在RedHat环境,输入 /etc/init.d/PowerPath start 在SuSE环境,输入 /etc/ PowerPath start2.3.3Solaris下PowerPath的安装与配置l 安装powerpath5.0.01. 插入PowerPathCD,输入下面命令来mount cd-rom:mount -F hsfs -r /dev/dsk/cxtydzs0 /cdrom/cdrom0其中,x,y,z代表主机的CD-ROM驱动2. 在SPARC主机中,输入cd /cdrom/cdrom0/UNIX/SOLARIS3. 在Opteron主机中,输入cd /cdrom/cdrom0/UNIX/SOLARIS_i3864. 输入/usr/sbin/pkgadd d开始安装。5. 安装完毕后,输入以下命令来输入License Key:/etc/emcpreg install单击“y”输入License Key6. 通过pkginfo -1 EMCpower 命令可以检测PowerPath是否安装完成。l 安装powerpath 5.0.1注:在安装powerpath 5.0.1,需要先安装PowerPath 5.0.0 (a full package)1. upload EMCPower.SOLARIS.5.0.1.Patch.b025.tar.gz2. Uncompress 安装包:gunzip EMCPower.SOLARIS.5.0.1.Patch.b025.tar.gz3. Untar 安装包:tar -xvf EMCPower.SOLARIS.5.0.1.Patch.b025.tar4. Install 安装包:patchadd . Note: If you use the patchadd -d command, you cannot back out the patch later. Output similar to the following displays information about the installation, ending with: Checking installed patches. Verifying sufficient filesystem capacity (dry run method). Installing patch packages. Oct 19 13:18:29 host1 root: ID 702911 user.alert Patch installation complete. REBOOT not required Patch 500-010 has been successfully installed. See /var/sadm/patch/500-010/log for details Patch packages installed: EMCpower The PowerPath Patch is now installed on the host.5. 根据输出提示,如果要求reboot主机,请reboot6. 通过pkginfo -1 EMCpower 命令可以检测PowerPath 5.0.1是否安装完成。2.4安装Navisphere Agent安装Navisphere Agent .0。2.4.1Windows下Host Agent和Navisphere CLI的安装与配置l 安装Host Agent1. 以系统管理员身份登陆系统。2. 双击安装文件进行Navisphere Host Agent的安装。3. 在Navisphere Agent Setup安装界面, 在欢迎界面点击Next。4. 在License Agreement页面,阅读license agreement,并点击Yes确定。5. 在Customer Information页面,输入客户信息并点击Next。6. 在Choose Destination Location 页面,点击 Next 选择默认安装地址。7. 如果你的系统中使用了iSCSI接口,请在弹出的询问框中选择Yes。8. 系统的安装目录依据操作系统的不同而有所区别: 在Windows Server 2003 (32-bit) 或 Windows 2000 操作系统中:drive:Program FilesEMCNavisphere Agent 在Windows Server 2003 (64-bit) 操作系统中:drive:Program Files (x86)EMCNavisphere Agent安装程序会拷贝程序到目标目录,安装成功后会显示如下信息:Navisphere Agent Service installed successfully。9. 在 Navisphere Agent Installer 对话框,点击 OK。Initialize Privileged User List 弹出,您可以添加安全用户到新的或已有的Host Agent 配置文件中。 如果一个文件不出现在 Config File中,Host Agent 配置文件就不存在服务器中,进入10步Create/Overwrite File选项。如果Host Agent 配置文件存在服务器中,进入 12 步使用Use Existing File 选项。10. 创建与改写配置文件,依照如下步骤:a 点击 Create/Overwrite File。b 在Config File中输入路径名称。c 跳到第 13步继续安装。11. 使用已有的配置文件,依照如下步骤:a 点击Use Existing File,路径和文件名会出现在 Config File中。b 如果你希望使用新的文件, 输入新的完整路径或者选择Browse查找文件。12. 确保 Privileged User List 包含所有有权配置存储系统的用户名称。添加用户到Privileged User List中:a 点击 Add。 Add Privileged User 对话框打开。b 在User Name选项中, 输入用户名称。c 在System Name选项中, 输入运行Manager的服务器名称。d 点击OK。从Privileged User List中删除用户:a 选择 privileged user 名称。b 点击 Remove。13. 点击OK保存新的privileged user list和新的配置文件。14. 在 Navisphere Agent Setup 对话框,点击 Finish。此时一个命令行窗口打开表明Host Agent服务正在启动。15. 安装完成后重新启动系统。l 启动Host Agent服务如果系统启动时,Host Agent服务没有启动,进行如下操作:1. 右击 My Computer,选择 Manage Services and Applications Services。2在Services 界面,右击 Navisphere Agent 选择 Start。3如果希望Host Agent自动启动,如下进行操作:a. 右击Navisphere Agent,选择Properties。b. 选择General页面。c. 在Startup Type中,选择 Automatic。l 停止Host Agent服务如要停止Host Agent服务,如下进行操作(在安装PowerPath时建议停止Host Agent服务,安装完毕后将其重新启动):1右击 My Computer,选择 Manage Services and Applications Services。2在Services界面,右击 Navisphere Agent 选择 Stop。l 安装Navisphere CLI1以系统管理员身份登陆系统。2双击安装文件进行Navisphere Host CLI的安装。3在Navisphere CLI Setup安装界面, 在欢迎界面点击Next。4在License Agreement页面,阅读license agreement,并点击Ye
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 民爆安全员培训心得课件
- 民法总论梁慧星课件
- 厨师考试题简答题及答案
- 农业新质生产力的发展机遇
- 保洁年度工作方案
- 保险业新质生产力报告
- 民族课件教学课件
- 企业打造新质生产力的路径
- 银行新质生产力监督路径
- 民族的大团结课件
- 《工程勘察设计收费标准》(2002年修订本)
- 围手术期疼痛管理专家共识
- 电视专题节目授权协议
- 麦尔兹窑工艺培训
- 钻探合同范本
- 福建省漳州市2025届高三上学期第一次质量检测化学试卷+
- 垃圾渗滤液处理站运维及渗滤液处理投标方案(技术方案)
- 高职建筑设计专业《建筑构造与识图》说课课件
- 人教版九年级物理上册《第十三章内能》单元检测卷(带答案解析)
- 中小学五项管理-作业-睡眠-手机-读物-体质五项管理-课件-(26张课件)
- 2024年苏州历史文化名城建设集团有限公司招聘笔试冲刺题(带答案解析)
评论
0/150
提交评论