湖南大学污水处理厂毕业设计全套计算书_第1页
湖南大学污水处理厂毕业设计全套计算书_第2页
湖南大学污水处理厂毕业设计全套计算书_第3页
湖南大学污水处理厂毕业设计全套计算书_第4页
湖南大学污水处理厂毕业设计全套计算书_第5页
已阅读5页,还剩15页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

well, with the effectiveness of services to defend the interests of the masses. Third, we should strive to do well. To achieve good practical results, the key is to know the law, to grasp the laws and using laws. Office of economic development, social progress, there are rules to follow. Only act according to the law, to overcome blindness and strengthening initiative, creative. Working in the Office, we should be good at analyzing the essence of things, to find regular thing, change from passive to active, to seek one. Investee 2. establishment of evaluation system. Evaluation system is essentially an incentive mechanism, the evaluation was objective and fair, reasonable, and can stimulate a persons energy, mobilizing peoples enthusiasm or be misleading, dampened the enthusiasm of people. At present, the concept of people-oriented people, but to establish and perfect evaluation system is still lagging behind. Work in this area should be seriously caught up. Three emphasis on to take advantage of. Is a focus on standards and scientific. A fundamental point of the evaluation criteria, is to keep contact, development, comprehensive eye evaluation of cadres. Office work, both record and potential performance; both subjective efforts, take another look at the objective condition; both pragmatic enough, take another look at the retreat level. Second, focus on participating the breadth of the subject. Evaluation of cadres must give full play to democracy, cadres and the masses handing over evaluation. Office work services leadership and service base, serve the people, then nominated the main object will contain a variety of services, so that assessment was accurate and to avoid one-sidedness. Third, pay attention to the seriousness of the conclusion. The use of evaluation findings is mainly embodied in his direction. Permitted to choose one, it would be tantamount to establishing a banner. Evaluation cant take care of the balance, otherwise it would undermine the offset the positive significance of evaluation. Office of the party committees at all levels should take the findings as on the cadres bonus-penalty, an important basis for future movements, incentive and restraint effect of making evaluations. 3. Prevention of understanding infidelity. People-centered development, concrete is dialectical,. In practice in the process, to prevent one-sided and still look, from actual people. One is to use dialectical point of view to understand. Humanist is the core of the scientific Outlook on development, remains the development of the scientific Outlook on development emphasizes, is still taking economic construction as the Center. Any departure from the development of thought and action, is a misinterpretation and misunderstanding of people-oriented. Adhere to people-oriented both to overcome one-sidedness of the old, but also to prevent one-sidedness, not accelerating the development of people and the opposition. Must be very clear, people oriented and speeding up development is not opposed, but consistent, we should never be湖南大学污水处理厂毕业设计全套(图纸计算书说明书)目 录一、城市污水雨水管网的设计计算 011.1、城市污水管网的设计计算011.1.1、确定城市污水的比流量011.1.2、各集中流量的确定011.2、城市雨水管网的设计计算01二、城市污水处理厂的设计计算 032.1、污水处理构筑物的设计计算032.1.1、中格栅032.1.2、细格栅042.1.3、污水提升泵房062.1.4、平流沉沙池092.1.5、厌氧池112.1.6、氧化沟122.1.7、二沉池172.1.8、接触池202.2、污泥处理构筑物的设计计算222.2.1、污泥浓缩池222.2.2、储泥池252.2.3、污泥脱水间25三、处理构筑物高程计算 253.1、水头损失计算253.2、高程确定27四、污水厂项目总投资,年总成本及经营成本估算 274.1、项目总投资估算274.1.1、单项构筑物工程造价计算274.1.2、第二部分费用284.1.3、第三部分费用284.1.4、工程项目总投资294.2、污水厂处理成本估算294.2.1、药剂费294.2.2、动力费(电费)294.2.3、工资福利费 304.2.4、折旧费 304.2.5、摊销费304.2.6、大修理基金提成率304.2.7、检修维护费314.2.8、利息支出314.2.9、其它费用314.2.10、工程项目年总成本 314.2.11、项目年经营成本 324.3、污水处理厂综合成本32第1章 城市污水雨水管网的设计计算1.1、城市污水管网的设计计算1.1.1 确定城市污水的比流量:由资料可知,XX市人口为41.3万(1987年末的统计数字),属于中小城市,居民生活用水定额(平均日)取150l/cap.d。而污水定额一般取生活污水定额的80-90%,因此,污水定额为150l/cap.d*80%=120 l/cap.d。则可计算出居住区的比流量为:q0=864*120/86400=1.20(l/s)1.1.2 各集中流量的确定:市柴油机厂 450*10*3.0=15.624(l/s)新酒厂取用9.69(l/s)市九中取用15.68 (l/s)火车站设计流量取用6.0(l/s) 总变化系数K=(Q为平均日平均时污水流量,l/s)。当Q5l/s时,K=2.3;当Q1000l/s时,K=1.3;其余见下表:Q5154070100200500K2.32.01.81.71.61.51.4对于城市居住区面积及街坊的划分可见蓝图所示,而对城市污水管段的计算由计算机计算,其结果可见后附城市污水管网设计计算表。1.2、城市雨水管网的设计计算:计算雨水管渠设计流量所用的设计暴雨强度公式及流量公式可写成: q=167A1(1+clgP)/(t1+mt2+b)n式中:q设计暴雨强度 (l/(sha) P设计重现期 (a) t1地面集水时间 (min) m折减系数 t2管渠内雨水流行时间 (min) A1b c n地方系数。首先,确定暴雨强度公式:由资料可计算径流系数 =5%*0.9+15%*0.9+5%*0.4+17%*0.3+13%*0.15 =0.68暴雨强度公式:参考长沙的暴雨强度公式: q=3920(1+0.68lgp)/(t+17)0.86重现期 p=1年,地面集水时间取t1=10 min,t=t+mt,折减系数取m=2.0, 所以 可以确定该地区的暴雨强度公式为:q0=*q=0.68*3920*(1+0.7lg1.0)/(27+2t2)0.86=2665.6/(27+2t2)0.86 对于城市雨水汇水面积及其划分可见蓝图所示, 而对城市雨水管段的计算由计算机计算,其结果可见后附的城市雨水管网设计计算表。特别说明:将雨湖设为一个雨水处理调节水池,雨湖的面积约为11000m3,根据雨湖两侧的地面标高差约为0.2m 则:设雨湖的有效调节水深为0.1m,所以调节水池的容积为 1100m2。 设调节水池24h排空一次 则:进入雨湖外排管段的集水井的调节水量为:/86400=12.73 (l/s) 第2章 城市污水处理厂的设计计算2.1、污水处理构筑物的设计计算2.1.1中格栅设计:为保证后续污水提升泵房的安全运行,隔除较大的漂浮物质及垃圾,在污水提升泵房前端设有中格栅。格栅的间距为e=40mm,栅前部分长度0.5m,中隔栅设2组,水量小时可只开一组,水量大时两组都开启。配置自动除渣设备。栅前流速取0.6m/s,栅前水深根据最优水力断面公B=2h=1.13m,则h=0.56m,过栅流速取v=0.7m/s,栅条间隙e=20mm,格栅的安装倾角为60,则栅条的间隙数为: n=Qmax*sin0.5/ehv =0.382*(sin60)0.5/(0.02*0.56*0.7) =45.3 n取46栅槽宽度:取栅条宽度为S=0.01 m B=S*(n-1)+e*n =0.01*(23-1)+0.02*23=0.68m,即每个槽宽为0.68m,则槽宽度B=2*0.68=1.36m(考虑了墙厚)。栅槽总长度: L=L+L+1.0+0.5+,L=(1.36-1.13)/(2*tg20)=0.32mL= L/2=0.16m H=h+h=0.56+0.3=0.86m则, L=L+L+1.0+0.5+=0.32+0.16+1.0+0.5+0.86/tg60=2.48m每日栅渣量:(单位栅渣量取W=0.05 m栅渣/10 m污水)W=Q*W=3*10*0.05/10=1.5m/d 0.2 m/d宜采用机械清渣方式。栅槽高度: 起点采用h=0.5m,则栅槽高度为H=0.56+0.5=1.06m。由于格栅在污水提泵前,栅渣清除需用吊车。为了便于操作,将栅槽增高0.8m,以便在工作平台上设置渣筐,栅渣直接从栅条落入栅筐,然后运走。2.1.2细格栅设计:设栅前水深h=0.56m,进水渠宽度B=2h=1.13。过栅流速取v=0.8m/s,栅条间隙e=10mm,格栅的安装倾角为60,则栅条的间隙数为:n=Qmaxsin0.5/ehv =0.382*(sin60)0.5/(0.01*0.56*0.8) =79.35 n取80栅槽宽度:取栅条宽度为S=0.01 m B=S*(n-1)+e*n =0.01*(80-1)+0.01*80 = 1.59m 取1.60m进水渠道渐宽部分长度: L= (B- B)/2tg=(1.59-1.13)/2tg20=0.65m进水渠展开角,B=B栅槽总宽,B进水渠宽度。栅槽与出水渠连接渠的渐宽长度:L= L/2=0.65/2=0.32m过栅水头损失:设栅条为矩形断面,h=k*v *sin /2gk系数,格栅受污物堵塞后,水头损失增大的倍数,取k=3;v过栅流速; 阻力系数,与栅条断面形状有关,=(s/e),当为矩形断面时,=2.42。代入数据得:h=3*2.42*(0.01/0.01)*0.8*sin60/(2*9.81) =0.21m为避免造成栅前涌水,故将栅后槽底下降h作为补偿。栅后槽总的高度:取栅前渠道超高为h2=0.3 (m),栅前槽高H1=h+h2=0.86 mH= h1+h+h2=0.21+0.56+0.3=1.07m栅槽总长度: L= l2+l1+0.5+1.0+ H1/tg60 =0.32+0.65+1.0+0.5+0.86/tg60 =2.97m每日栅渣量:取W1=0.1 m3/(103*m3)W=Qmax* W1*86400/(K总*1000) =0.382*0.1*86400/(1.4*1000)=2.4 m3/d 0.2 m3/d 宜采用机械清渣方式中格栅和细格栅均采用型号为JT的阶梯式格栅清污机,并选用285型长度为5m的无轴螺旋运送机两台。2.1.3污水提升泵站 设计参数: 平均秒流量Q=261.564(l/s) 最大秒流量Q=261.564*1.46=381.88(l/s) 进水管管底标高31.624m,管径D=900mm,充满h/d=0.3,水面标高31.957m,地面标高38.300m。 出水管提升后的水面标高38.800m经100m管长至污水处理构筑物。选择集水池与机器间合建式的圆型泵站,考虑3台水泵(其中1台备用)。设计内容:每台水泵的容量为Q/2=381.88/2=190.94(l/s),集水池容积相当于采用一台泵6min的容量:W=190.94*60*6/1000=68.74(m)。有效水深采用H=2.0m,则集水池面积为34.37m。 选泵前总扬程估算: 经过格栅的水头损失为0.1m,集水池最低工作水位与所需提升的最高水位之间的高差为:38.800-(31.624-0.9*0.37-0.1-2.0)=9.609(m)出水管管线水头损失:a)总出水管:Q=381.88l/s,选用管径500mm,v=1.94m/s,1000i=9.88。当一台水泵运转时,Q=190.94l/s,v=0.97m/s 0.7m/s。设总出水管管中心埋深1.0m,局部损失为沿程损失的30%,则泵站外管线水头损失为:320+(38.800-38.300+1.0)*9.88*1.3/1000=4.129mb)水泵总扬程:泵站内的管线水头损失假设为1.5m,考虑自由水头为1.0m,则水泵的总扬程为:H=1.5+4.129+9.609+1.0=16.239(m)c)选泵:选用250WD污水泵3台(其中1台备用),水泵参数如下:Q=180.5278l/s H=1217m 转数n=730转/分 轴功率N=3764KW 配电动机功率70KW 效率=69.573% 允许吸上真空高度H=4.25.2m 叶轮直径D=460mmd)泵站经平剖面布置后,对水泵总扬程进行核算:吸水管路水头损失计算:每根吸水管Q=190.94l/s,选用管径450mm,v=1.21m/s,1000i=4.41。根据图示,直管部分长度为1.2m,喇叭口(=0.1),D=450mm90弯头1个(=0.67),D=450mm闸门1个(=0.1),D=450d200mm渐缩管1个(=0.21)沿程损失:1.2*4.41/1000=0.0053m局部损失:(0.1+0.67+0.1)*1.21/2g+0.21*6.5/2g=0.518(m)则吸水管路水头总损失为:0.518+0.0053=0.523(m)出水管路水头损失计算:(计算图见泵房平剖面图)每根出水管Q=190.94l/s,选用管径400mm,v=1.53m/s,1000i=8.23。从最不利点A点起,沿A、B、C、D、E线顺序计算水头损失:AB段D200400mm渐放管1个(=0.30),D400mm单向阀1个(=1.40),D400mm90弯头1个(=0.60),D400mm阀门1个(=0.10)。局部损失:0.30*6.5/2g+(1.40+0.60+0.10)*1.53/2g=0.90(m)BC段选用D500mm管径,Q=190.94l/s,v=0.97m/s,1000i=2.60,直管部分长0.70m,XX字管1个(=1.5,转弯流)。沿程损失:0.70*2.60/1000=0.002(m)局部损失:1.5*1.53/2g=0.179(m)CD段选用D500mm管径,Q=381.88l/s,v=1.94m/s,1000i=9.88,直管部分长0.70m,XX字管1个(=0.10,直流)。沿程损失:0.70*9.88/1000=0.007(m)局部损失:0.10*1.94/2g=0.019(m)DE段直管部分长5.0m,XX字管1个(=0.10),D500mm90弯头2个(=0.64)。沿程损失:5.0*9.88/1000=0.049(m)局部损失:(0.10+2*0.64)1.94/2g=0.265(m)综上,出水管路总水头损失为:4.128+0.90+0.002+0.179+0.007+0.019+0.049+0.265=5.549(m)则水泵所需总扬程:H=0.523+5.549+9.609+1.0=16.688(m)故选用250WD型污水泵是合适的。2.1.4 平流沉砂池(设2组)长度:设平流沉砂池设计流速为v=0.25 m/s停留时间t=40s,则,沉砂池水流部分的长度(即沉砂池两闸板之间的长度): L =v*t=0.25*40=10m水流断面面积:A=Qmax/v=0.382/0.25=1.52m池总宽度 : 设n=2 格,每格宽b=1.2m,则, B=n*b=2*1.2=2.4m(未计隔离墙厚度,可取0.2m) 有效深度: h2=A/B =1.52/2.4=0.64m沉砂室所需的容积: V= Qmax*T*86400*X/(kz*10)V沉砂室容积,m;X城市污水沉砂量,取3 m砂量/10m污水;T排泥间隔天数,取2d;K流量总变化系数,为1.4。代入数据得:V=86400*0.382*2*3/(1.4*10)=1.41 m,则每个沉砂斗容积为V=V/(2*2)=1.41/(2*2)=0.35 m.沉砂斗的各部分尺寸:设斗底宽a1=0.5 m,斗壁与水平面的倾角为55,斗高h3=0.5m,则 沉砂斗上口宽:a=2 h3/tg55+a1 =2*0.5/1.428+0.5 =1.2m沉砂斗的容积:V0 = (h3/6)*(a2+ a* a1+ a12) =0.5/6*(1.22+ 1.2* 0.5+ 0.52) =0.35m3 = V这与实际所需的污泥斗的容积很接近,符合要求;沉砂室高度: 采用重力排砂,设池底坡度为0.06,坡向砂斗,L=(L-2*a)/2=(10-2*1.2)/2=3.8mh3 = h3+0.006 L=0.5+0.06*3.8=0.728m池总高度:设沉砂池的超高为h1=0.3m,则H= h1+h2+h3=0.3+0.64+0.728=1.67m进水渐宽及出水渐窄部分长度: 进水渐宽长度 L=(B-B)/2tg=(2.4-1.0)/(2*tg20)=1.92m 出水渐窄长度 L= L=1.92m校核最小流量时的流速:最小流量为Q=261.564/2=130.782l/s,则V= Q/A=0./0.76=0.172m/s 0.15m/s符合要求另外,需要说明的是沉砂池采用静水压力排砂,排出的砂子可运至污泥脱水间一起处理。2.1.5厌氧池设计参数进入厌氧池的最大流量为Qmax=0.382 m3/s,考虑到厌氧池和氧化沟可作为一个处理单元,总的水力停留时间超过了20h,所以设计水量按最大日平均时考虑:Q=Qmax/kz=0.382/1.46=0.26 m3/s。共设两座厌氧池,每座设计流量为0.13m3/s,水力停留时间:T=2.5h,污泥浓度:X=3g/l,污泥回流浓度为:XR=10g/l;设计计算a. 厌氧池容积: V=Q*T=130*10-3*2.5*3600=1170m3b. 厌氧池的尺寸 水深取h=5m,则厌氧池的面积为:A= V/h=1170/5=234m2厌氧池的直径为:D=(4A/3.14)1/2=(4*234/3.14)1/2 =17.26m,取D=18m考虑到0.3m的超高,所以池子的总高度为H=h+0.3=5.3mc. 污泥回流量的计算:回流比的计算:R=X/(Xe-X)=3/(10-3)=0.42污泥回流量:QR=R*Q=0.42*130*10-3*86400=4717.4m3/d=196.56m3/h选用型号为JBL800-2000型的螺旋浆式搅拌机,两台该种型号的搅拌机的技术参数如下;浆板直径:800-2000mm,转速:4-134 (r/min),功率:4.5-22KW,浆叶数:3 个。2.1.6氧化沟设计参数氧化沟设计为两组。氧化沟按照最大日平均时间流量设计,每个氧化沟的流量为130l/s,即11232m3/d。进水BOD5:So=200mg/l 出水BOD5:Se=20mg/l进水NH3-N: 40mg/l 出水NH3-N: 15mg/l总污泥龄;22d MLSS:4000mg/l f=MLVSS/MLSS=0.7曝气池:DO=2mg/l NOD=4.6mgO2/mgNH3-N氧化,可利用氧2.6 mgO2/mgNO-3-N还原 =0.9 =0.98其他参数:a=0.6 kgoss/kg BOD5, b=0.051/d脱氮效率:qdn=0.0312kgNO-3-N/(kgMLVSS*d)k1=0.231/d k02=1.3mg/l剩余碱度:100mg/l(保持PH7.2)所需要的碱度:7.1mg碱度/mgNH3-N氧化;产生碱度:3.0mg碱度/mgNO-3-N还原硝化安全系数:2.5, 脱硝温度修正系数:1.0设计计算a) 碱度平衡计算I. 由于设计的出水BOD5为20mg/l,则出水中溶解性BOD5为:20-0.7*20*1.42*(1-0.23*5)6.4mg/l II. 采用污泥龄22d,则日产泥量为:aQlr/1+btm 0.6*11232*(200-6.4)/1000(1+0.051*22)1304.71/2.122=614.85kg/ld 设其中有12.4%的为氮,近似等于TNK中用于合成部分为:12.4%*614.85=76.24kg/dTNK中有76.24*1000/11232=6.8mg/l需要用于氧化的NH3-N:40-6.8-5=28.2mg/l需要还原的NO-3-N:28.2-10=18.2mg/lIII. 碱度平衡计算已知产生0.1mg碱度/去除1mgBOD5,进水中碱度为280mg/l剩余碱度:280-7.1*28.2+3.0*18.2+0.1*(200-6.4) =280-200.22+51.6+19.36=150.74mg/l(caco3)此值可以保证PH7.2。计算硝化速度: n =0.47*0.098*(T-15)* 2/(2+100.05*15-1.158)* 2/(2+1.3) =0.204l/s(T=12)故泥龄为:tw=1/0.204=4.9d采用的安全系数为2.5,故设计污泥龄为:2.5*4.9=12.5d原来假定的污泥龄为22 d,则硝化速度为:n =1/22=0.045l/d单位基质利用率为: =n+b/a=0.045+0.05/0.6=0.158 kg BOD5/(kgMLVSS*d)而 MLVSS=0.7*4000=2800mg/l则,所需要的MLVSS的总量为 11232*194/(0.158*1000)=13791.2kg硝化容积:Vn=13791.2/2800*1000=4925.42m3水力停留时间为:tn=4925.42/11232*24=10.52hb) 反硝化区的容积:当温度为12时,反硝化速度为 qdn=0.03*(f/m)+0.029(T-20) 取1.08 =0.03*(200*24/4000*16)+0.0291.08(12-20) =0.03125*1.08-8 =0.017 kg NO-3-N/(kgMLVSS*d)还原NO-3-N的总量为:18.2/1000*11232=204.42kg脱氮所需要的MLSS:204.42/0.017=12024.85kg脱氮所需要的容积:Vdn=12024.85*1000/2800=4294.59m3水力停留时间:tdn=4294.59/11232*24=9.176h总的池容积为:V= Vn +Vdn=4925.42+4294.59=9220.01m3c) 氧化沟的尺寸:氧化沟采用改良式的carrousel六沟式的氧化沟。取池深为3 m,单沟宽为6m,则沟总的长度为:9220.01/(3*6)=512.22m,其中好氧段的长度为260.11m,缺氧段的长度为252.11m,弯道处的长度为5*3.14*6+12+2*3.14*6=143.88 m,则,单个直道长度为(512.22-143.88)/6=61.39m,则氧化沟的总沟长为:61.39+6+12=79.39m,总的池宽为:6*6=36md) 需氧量计算:采用以下的经验公式Q2(kg/d)=A*lr+B*MLSS+4.6*NR-2.6NO3经验系数为:A=0.5, B=0.1NR需要硝化的氧量为:28.2*11232*10-3=316.74kg/dR =0.5*11232*(0.2-0.0064)+0.1*2.8*4294.59+4.6*316.74-2.6*204.42=1087.258+1202.485+1457.004-531.492=3215.255kg/d=133.97kg/h当温度为20时,脱氧清水的充氧量为:取T=30,=0.8,=0.9,Cs(20)=9.17mg/l,Csb(30)=7.63则R0=R Cs(20)/* Csb(T)-C*1.024(T-20) =133.97*9.17/0.8*(0.9*1.0*7.63-2)*1.024(30-20) =248.9kg/he) 回流污泥量 X=MVLSS=4g/l Xr=10g/l则,R=4/(10-4)=0.67因为回流到厌氧池的污泥为11%,则回流到氧化沟的污泥总量为51.7%Qf) 剩余污泥量Qw=614.85/0.7+(200-180)/1000*11232=878.357+224.64=1102.997kg/d如果污泥由底部排除,且二沉池的排泥浓度为10g/l,则每个氧化沟的产泥量为1102.997/10=110.3m3/d设计采用的曝气机选用型号为DS325的可调速的倒伞型叶轮曝气机五台,该种机子的技术参数如下所示:叶轮的直径为3250 mm,电动机额定功率为55 kw,电动机转速:33 r/min,充气量:21-107 kg/h,设备重量:4400 kg曝气机所需要的台数为 n=488.56/100=4.9 取n=5 台因此,每组共设的曝气机为5 台,全部的机子都是变频调速的。为了保证氧化沟在缺氧状态下混合液不发生沉淀,还设有型号为SK4430的淹没式搅拌机13 台,即每个廊道设置2台,功率为4.0 KW。而为了保证氧化沟内部水流的循环形成,在进水处的下方设置了一台淹没式搅拌机,能起到推进水流流向的作用。2.1.7二沉池设计参数该污水处理厂采用周边进水周边出水的幅流式沉淀池,共设了两座;设计流量为:11232 m3/d(每组),表面负荷:qb=0.8 m3/(m2*h)固体负荷:Ng=2000 kg/(m2*d),堰负荷:2.2l/(s*m)设计计算:a) 沉淀池的面积:按照表面负荷计算:F1=11232/(24*0.8)=585m3b)二沉池的尺寸计算:I. 沉淀池的直径为:D=(4A/3.14)0.5=(4*585/3.14)0.5=28mII. 沉淀池的有效水深: 沉淀时间取2.5 h,则,沉淀池的有效水深为 h1= qb *t=0.8*2.5=2mIII. 存泥区的所需的容积为了保证污泥的浓度,存泥时间Tw不宜小于2.0 h,则,所需要的存泥容积为VW =2*T*(1+R)*Q*X/(X+Xr)=2*2*(1+0.67)*11232*4000*2/(4000+10000)*24=1786.423m3以下计算存泥区的高H2:每座二沉池的存泥区的容积为VW1=1786.423/2=893.211m3则存泥区的高度为:H2= VW1/A1=893.211/585=1.53mIV. 二沉池的总高度H:取缓冲层H3=0.4 VM ,超高H4=0.5 m则, H= H3+H4+H2+H1=0.4+0.5+1.53+2.0=4.43m设二沉池池底坡度为I=0.010,则池底的坡降为H5=(28-2.5)/2*0.010=0.13m池中心总深度为H= H+H5=4.43+0.13=4.56m池中心的污泥斗深度为H6=1m,则二沉池的总高度H7为: H7=H+H6=4.56+1=5.56m,取H7=5.6mV. 校核径深比:二沉池的直径与池边总水深之比为: D/(H3+H2+H1)=28/(0.4+1.53+2.0)=7.12 满足在区间(6,12),符合条件;校核堰负荷:Q/(3.14*D)=11232/(3.14*28)=127.75m3/(d*m)190 m3/(d*m)=2.2 l/(s*m)满足条件。C)进水配水渠的设计计算;采用环行平底配水渠,等距设置布水孔,孔径100mm,并加了直径是100mm长度是150mm的短管。配水槽底配水区设置挡水裙板,高0.8 m,以下的计算是以一个二沉池的数据计算的。配水槽配水流量Q=(1+R)Qh=(1+0.67)*11232=18757.44m3/d设配水槽宽1.0 m,水深为0.8 m,则配水槽内的流速为v1=Q/l*b=18757.44/(86400*1.0*0.8)=0.22/0.8*1.0=0.3m/s设直径为0.1m的配水孔孔距为S=1.10 m,则,配水孔数量为n=(D-1)/S=(28-1)*3.14/1.10=77.07 条,取 n=78条,则实际S=1.10 m,与题设一致,满足条件。配水孔眼流速为v2 v2=4Q/(n*3.14*d2)=0.87/(7

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论