




免费预览已结束,剩余11页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
STANDARDS FOR VAPOUR EMISSION CONTROL SYSTEMS 1 The Maritime Safety Committee, at its sixtieth session, recognized the necessity of the international standards for vapour emission control systems and approved the standards developed by the BCH Sub-Committee at its twenty-first session for use by Administrations, as contained in the annex.2 Member Governments are invited to note this development.1 GENERAL1.1 These standards have been developed for the design, construction, and operation of vapour collection systems on tankers and vapour emission control systems at terminals. The standards are intended to apply to vapour emission control systems which collect vapours of flammable cargoes from tanker cargo tanks during cargo loading or ballasting operations. Vapour emission control systems which collect vapour of cargoes having characteristics which may pose hazards in addition to or other than flammability should be subject to special consideration by the Administration. These standards are not intended to require the use of vapour emission control systems but rather to recommend safety standards when such systems are utilized. The requirement to collect vapours will stem from a port Administration or terminal regulation. These standards are intended to promote the safety of terminals, tankers, and their personnel, recognizing the unique design features and characteristics of these systems.1.2 Definitions1.2.1 Diluted: the condition in which the concentration of a flammable gas in a flammable gas/air mixture is less than 50% of the lower explosive limit of the gas.低浓度燃气1.2.2 Enriched: the condition in which the concentration of a flammable gas in a flammable gas/air mixture is not less than 150% of the upper explosive limit of the gas. When flammable gases are mixed to achieve an enriched condition, the upper explosive limit of the flammable gas mixture shall be used.高浓度燃气1.2.3 Flammable cargoes means cargoes of crude oil, petroleum products, and chemicals having a flashpoint not exceeding 60 degrees C (closed cup test), as determined by an approved flashpoint apparatus, and a Reid vapour pressure which is below atmospheric pressure and other liquid products having a similar fire hazard.可燃货物1.2.4 Inerted: the condition in which the oxygen content in a flammable gas/air mixture is 8% or less by volume.惰性1.2.5 Independent as applied to two systems means that one system will operate with a failure of any part of the other system except power sources and electrical feeder panels.备用1.2.6 Maximum allowable transfer rate means the maximum volumetric rate at which a tanker may receive cargo or ballast.最大驳运速度1.2.7 Tanker vapour connection means the point in a tankers fixed vapour collection system where it connects to a vapour collection hose or arm.油船蒸汽收集连接端1.2.8 Terminal vapour connection means the point in a terminals vapour collection system where it connects to a vapour collection hose or a vapour collection arm.岸站蒸汽收集连接端1.2.9 Vapour balancing means the transfer of vapour displaced by incoming cargo from the tank of a tanker receiving cargo into a tank of a facility delivering cargo via a vapour collection system.舱室蒸汽平衡1.2.10 Vapour collection system means an arrangement of piping and hoses used to collect vapour emitted from a tankers cargo tanks and transport the vapour to a vapour processing unit.蒸汽收集管系1.2.11 Vapour destruction unit means a vapour processing unit that destroys cargo vapour by a means such as incineration.蒸汽销毁单元1.2.12 Vapour dispersion system means a vapour processing unit which releases cargo vapour to the atmosphere through a venting system not located on the tanker being loaded or ballasted.蒸汽疏散系统1.2.13 Vapour emission control system means an arrangement of piping and hoses used to control vapour emissions collected from a tanker, and includes the vapour collection system and the vapour processing unit.蒸汽排放控制系统1.2.14 Vapour processing unit means the components of a vapour control system that recovers, destroys, or disperses vapour collected from a tanker.蒸汽处理单元1.2.15 Vapour recovery unit means a vapour processing unit that recovers cargo vapour by a non-destructive means such as lean oil absorption, carbon bed adsorption, or refrigeration.蒸汽回收单元2 TANKERS油船2.1 Tanker vapour processing unit油船蒸汽处理单元2.1.1 In addition to the requirements of this section, each tanker which has a vapour processing unit located onboard should, to the satisfaction of the Administration, meet the vapour collection and processing design requirements for a shoreside terminal contained in section 3.配有蒸汽处理单元的油船除满足本节要求外,还应满足第3节对岸站蒸汽收集和处理的设计要求,以使主管机关满意2.2 General一般要求2.2.1 Each chemical, product or crude carrier should have vapour collection piping which is permanently installed with a tanker vapour connection located as close as practical to the loading manifold. In lieu of permanent piping, Administrations may permit chemical tankers to have a permanent vapour connection at each cargo tank for connection to a vapour hose which should be kept as short as practicable.每艘化学品船、成品油或原油油船应装设蒸汽收集管路,该管路和油船永久相连的蒸汽排放接头尽可能位于货物装载集成管路附近。在固定管系位置,主管机关允许化学品船每一货舱室可以有一个永久的蒸汽排放接头以连接到尽可能短的蒸汽软管上;2.2.2 If a tanker simultaneously collects vapours from cargoes which react in a hazardous manner with other cargoes, it should keep these incompatible vapours separate throughout the entire vapour collection system.如果一艘油船同时收集不同货物蒸汽,且货物之间会发生反应并危及安全,应该设计成完全独立的蒸汽收集系统以分离不相容的蒸汽。2.2.3 A means should be provided to eliminate liquid condensate which may collect in the system, such as draining and collecting liquid from each low point in the line.应该采取措施消除在系统中可能收集的液体冷凝物,诸如能够从管系中最低点收集和排泄液体冷凝物。2.2.4 Vapour collection piping should be electrically bonded to the hull and should be electrically continuous.蒸汽连接管系应连接于船体,并具有电气连续性2.2.5 When inert gas distribution piping is used for vapour collection piping, means to isolate the inert gas supply from the vapour collection system should be provided. The inert gas main isolation valve required by SOLAS 74, as amended, chapter II-2, regulation 62.10.8 may be used to satisfy this requirement.如果惰性气体总管兼用于蒸气收集管路时,应有惰性气体供应管与蒸气收集管系隔离的装置,惰性气体主隔离阀应满足SOLAS 74修正案第II-2章第62.10.8有关要求。2.2.6 The vapour collection system should not interfere with the proper operation of the cargo tank venting system.蒸汽收集系统不应干扰货舱透气系统的正常操作。2.3 Vapour line connections蒸汽管路的连接2.3.1 An isolation valve capable of manual operation should be provided at each tanker vapour connection. The operating position of this valve should be readily determined visually.在每一个油船蒸汽排放连接端应设置一个可手动操作的隔离阀,该阀的操作位置应能容易发现。2.3.2 The end of each vapour collection pipe or vapour collection hose should be readily identifiable to prevent misconnection.每一个蒸汽接管或软管的末端都应容易辨认以防止误连。2.3.3 In order to prevent the possible misconnection of the vapour manifold to a shoreside terminal liquid loading line, each tanker vapour connection flange should conform to the applicable industry standard.* This provision is applicable regardless of the size of the vessel.为了防止蒸汽总管与岸上液体装载管线的误连,每一个油船蒸汽排放接头法兰应该符合适用的工业标准(OCIMF油舱总管和相关设备建议 第4版 1991,A部分5.2.2.)。该规定适用于所有尺寸的船舶。* OCIMF Recommendations for Oil Tanker Manifolds and Associated Equipment, Fourth Edition 1991, section A.5.2.2.OCIMF油舱总管和关联设备建议 第4版 1991,A部分5.2.2.2.3.4 Each vapour collection hose should meet the following:.1 be suitable for the service;.2 be electrically continuous and.3 have an extra hole in each flange in accordance with the applicable industry standard.* Ibid. Section A.5.2.4每一蒸汽软管应该满足如下要求:.1 适宜的用途.2 电气连续性.3 每一法兰孔满足适用的工业标准(Ibid. A部分.5.2.4)Footnotes:脚注2.4 Cargo gauging equipment货物测量设备2.4.1 Each cargo tank of a tanker that is connected to a vapour collection system should be equipped with a cargo gauging device which:连接到蒸汽收集系统的每一个油舱都应配备一套货物测量设备,并满足如下要求:.1 provides a closed gauging arrangement that does not require opening the tank to the atmosphere during cargo transfer;提供一个封闭测量布置,该布置要求在货物驳运期间不能打开货物舱室.2 allows the operator to determine the liquid level in the tank for the full range of liquid levels in the tank;货舱液位的显示应能实现全程范围显示.3 indicates at the location where cargo transfer is controlled, the liquid level in the tank; and各货舱的液位应在货控室集中显示.4 if portable, is installed on the tank during the entire transfer operation.如测量装置为可携式,在整个装卸作业过程中应将其安装在舱内2.5 Liquid overfill protection货物溢流保护2.5.1 Each cargo tank of a tanker should be equipped with an overflow control system.每一液货舱应配备一个溢流控制系统2.5.2 The overflow control system required by paragraph 2.5.1 should:2.5.1.条所述的溢流控制系统要求如下:.1 be independent of the cargo gauging system;独立于货物测量系统.2 come into operation when the normal tank loading procedures fail to stop the tank liquid level exceeding the normal full condition;当正常装载过程中舱室液位超过正常满载状态而继续装载时,溢流控制系统启动.3 give a visual and audible tank overflow alarm to the ships operator;发出溢流声光报警.4 provide an agreed signal for sequential shutdown of onshore pumps or valves or both and of the ships valves. The signal as well as the pump and valve shutdown may be dependent on operators intervention. The use of shipboard automatic closing valves should be permitted only when specific approval has been obtained from the Administration and the Port Administration concerned;为岸泵或阀或岸泵、阀以及船阀提供一个顺序切断的指定信号。关闭泵阀的信号可以由操作者提供。仅仅当获得有关主管机关或港口行政部门特殊批准时,船舶自闭阀可允许被使用.5 have alarms fitted in the cargo control room, where provided, but in each case in such a position that they are immediately received by responsible members of the crew;尽可能在货控室装设报警点,且在该位置的每次报警都能被值班船员立即接收到。.6 alarm in the event of loss of power to the alarm system or failure of the electrical circuitry to the tank level sensor; and报警系统失电或液位传感器电路故障时报警.7 be able to be checked at the tank for proper operation prior to each transfer or contain an electronic self-testing feature which monitors the condition of the alarm circuitry and sensor.在每次驳运前,能够对舱室进行检测以确保能够正常操作,或具有能够监测报警电路和传感器的电子自检功能2.6 Vapour overpressure and vacuum protection蒸汽压力过高或真空保护2.6.1 Each cargo tank should have a controlled pressure venting system which is designed on the basis of the maximum designed loading rate multiplied by a factor of at least 1.25 to take account of gas evolution, in order to prevent the pressure in the tank from exceeding the design pressure.每一货舱室应有一个可控压力释放系统,其系统的气体排放速度设计为最大设计装载速度的1.25倍以防止舱内压力超过设计压力。2.6.2 Each cargo tank should have a controlled vacuum venting system which is capable of preventing a vacuum in the cargo tank vapour space, whether generated by withdrawal of cargo or vapour at maximum rates, that exceeds the maximum design vacuum for the tank.每一货舱室应有一个可控真空释放系统,其设计能够在最大货物回收速度或最大蒸汽回收速度下,防止舱内蒸汽空间产生的真空度超过最大设计值。2.6.3 A prototype of each pressure or vacuum or pressure/vacuum venting device should be bench tested for venting capacity by a test method acceptable to the Administration.每一种压力释放设备或真空释放设备或压力/真空释放设备的原型装置应使用一种主管机关可以接受的试验方法进行试验以验证其释放能力。2.6.4 Each tanker equipped with a vapour collection system that is common to two or more tanks should be fitted with a pressure sensing device that senses the pressure in the main vapour collection line for those tanks, and which:对于两个或更多货舱公用一个蒸汽收集系统的油船,应装设一套能够感应蒸汽收集主管路上压力的压力传感设备,并应满足:.1 has a high pressure alarm that alarms at a pressure of not more than the lowest pressure relief valve setting in the cargo tank venting system; and高压报警的设定值不高于货舱透气系统中压力释放阀的最低设定压力.2 has a low pressure alarm that alarms at a pressure of not less than atmospheric pressure for an inerted tanker, or the lowest vacuum relief valve setting (i.e. that setting nearest to atmospheric pressure) in the cargo tank venting system for a non-inerted tank vessel.低压报警的设定值:对惰化舱应不低于大气压,对非惰化舱不低于货舱透气系统中真空释放阀的最低设定压力。2.7 Operational procedures操作手册2.7.1 The procedures set forth in relevant IMO guidance and established industry guidelines should be observed, as applicable, with regard to preparation for transfer, and transfer of cargo and of ballast into cargo tanks.*应该遵守IMO指南和适用的工业指南对有关货物驳运的准备、驳运货物和驳运压载物到货舱等方面的程序要求。MSC/Circ.299ICS 油轮安全指南(化学品)* ISGOTTMSC/Circ.299ICS Tanker Safety Guide (Chemical)Footnote :2.7.2 The rate of cargo transfer should not exceed the maximum allowable transfer rate as determined by the lesser of the following:货物驳运速度应不超过最大允许驳运速度,下述取其小者。.1 the venting capacity of the pressure relief valves in the cargo tank venting system divided by a factor of at least 1.25.货舱透气系统上的压力释放阀的透气能力的0.8倍.2 the vacuum relieving capacity of the vacuum relief valves in the cargo tank venting system; and货舱透气系统上的真空释放阀的真空释放能力.3 The rate based on pressure drop calculations for a given pressure at the facility vapour connection, such that the pressure in any cargo tank connected to the vapour collection system does not exceed 80% of the opening set pressure of any pressure relief valve in the cargo tank venting system.设备蒸汽排放连接端给定的压力通过压力降计算所得的速度,比如连接到蒸汽收集系统的任何货舱内的压力不超过货舱透气系统压力释放阀的设定开启压力的80%。2.7.3 A cargo tank should not be filled higher than the level at which the overflow alarm required by paragraph 2.5.1 is set.货舱液位不能超过2.5.1条设定的溢流报警液位2.7.4 A cargo tank should not be opened to the atmosphere for gauging or sampling while the tanker is connected to a vapour emission control system unless loading to the tank is stopped, the tank is isolated from any other tank which is in the process of being loaded, and precautions are taken to reduce any pressure in the cargo tank vapour space and prevent an electrostatic spark from occurring.当油船被连接到蒸汽排放控制系统上时,不应为了测量和取样而把货舱盖打开,除非停止对该货舱室进行装载,该舱室应与正在进行装载作业的其他舱室隔离,同时,采取预防措施防止减少货舱蒸汽空间的压力,防止静电火花的产生。2.7.5 If the tanker is equipped with an inert gas system the isolation valve required by paragraph 2.2.5 should remain closed during vapour transfer.如果油船配备惰气系统,那么在蒸汽装运期间2.2.5条要求的隔离阀应保持关闭。2.7.6 Unless equipped with an automatic self-test and circuit monitoring feature, each tank overflow control system alarm required by paragraph 2.5.1, on a cargo tank being loaded, should be tested at the tank for proper operation prior to the start of cargo transfer.除非装载自动自检和电路监测装置,否则,在货物装载前,应按照2.5.1条的要求进行舱室溢流控制系统报警试验以确保能够正常操作2.8 Training培训2.8.1 Each person in charge of a transfer operation utilizing a vapour emission control system should have completed a training programme covering the particular system installed on the tanker. The training should encompass the purpose and principles of operation of the vapour emission control system and provide an understanding of the equipment involved and associated hazards. In addition the training should provide an understanding of operating procedures including testing and inspection of equipment, pre-transfer procedures, piping connection sequence, start-up procedures, normal operations and emergency procedures. Training should also include an understanding of the shoreside terminal equipment and operating procedures.每一个使用蒸汽排放控制系统的进行驳运作业的操作人都应接受一次对安装在油船上的一套独立系统课程培训。该培训应包括蒸汽控制系统的作用和原理以及对涉及危险的设备的认识。另外,培训应该包括对有关设备的试验和检查、预驳运程序、管路连接顺序、启动程序、正常作业和应急程序等方面的操作程序的理解。培训还包括有关岸站设备设备和操作程序的了解。2.9 Transfer procedures驳运程序2.9.1 Tanker transfer procedures should contain information on the tankers vapour collection system including:油船驳运程序应包括油舱蒸汽收集系统相关信息,具体如下:.1 a line diagram of the tankers vapour collection piping indicating the locations and purpose of all control and safety devices;指示所有控制和安全装置位置和用途的油船蒸汽收集管系的管路示意图.2 the maximum allowable transfer rate as limited by the venting capacity of the pressure or vacuum relief valves, or any other factor which would limit the transfer rate;受压力真空释放阀透气能力限制或其他因素限制的最大允许驳运速度.3 the maximum pressure drop in the vessels vapour collection system for various transfer rates;船舶蒸汽收集系统在不同驳运速度下的最大压降.4 the relief settings of each pressure and vacuum relief valve;压力真空释放阀设定释放压力.5 pre-transfer procedures; and预驳运程序.6 procedures to be followed in the event of a fault during vapour collection operations.蒸汽收集作业故障程序3 SHORESIDE TERMINALS岸站3.1 General一般要求3.1.1 A vapour emission control system design and installation should eliminate potential tanker overfill hazards, tanker overpressure and vacuum hazards, and sources of ignition to the maximum practical extent, in accordance with good design and engineering practice. Each remaining hazard source which is not eliminated should be specifically addressed in the protection system design and operational requirements.一套蒸汽排放控制系统的设计和安装应该消除潜在的溢流、超压及负压和燃烧等危险情况,每一个残存的而不能消除的危险源在保护系统的设计和操作要求上都应特别强调。3.1.2 A hazards analysis should be conducted on the design and operation which demonstrates the following:有关设计和操作的危险分析如下:.1 the vapour emission control system is designed to permit the system to continuously operate safely when receiving cargo vapour from tankers over the full range of transfer rates expected at the terminal,当接收来自油船上的货物蒸汽超过岸站上预期的传送速度时,蒸汽排放控制系统允许该系统能够安全而连续地操作。.2 the vapour emission control system is provided with the proper alarms and automatic control systems to prevent unsafe operation;蒸汽排放控制系统设有适宜的报警点和自动控制系统以防止不安全操作。.3 the vapour emission control system is equipped with sufficient safety systems to minimize damage to personnel, property, and the environment if an accident were to occur, and蒸汽排放控制系统设有可靠的安全系统,在发生事故时以尽量减少人员、财产和环境损失。.4 the operating procedures minimize the potential for improper or unsafe operation by personnel.操作程序尽量避免潜在的不适当的或不安全的人为操作3.1.3 Vapour collection system piping, fittings and equipment should be suitable for the intended service. Material generally should be of steel or equivalent.蒸汽收集系统管路、配件及设备应适合预定的用途,材料一般应为钢制或等效材料3.1.4 Electrical installations in hazardous locations should be to the satisfaction of the national authority for
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 木材与纳米多相结构的环境友好性研究-洞察阐释
- 教育信息化与未来学校建设
- 自动化运维的实时监控与告警机制研究-洞察阐释
- 2025年中国床尾单行业市场发展前景及发展趋势与投资战略研究报告
- 2024-2030全球含水率分析仪行业调研及趋势分析报告
- 解热止痛散药企与医院的经济合作影响分析-洞察阐释
- 2025-2030年中国液晶DVD一体机行业深度研究分析报告
- 社交媒体网络的操纵行为特征分析-第1篇-洞察阐释
- 瘦肉精residues在厌氧发酵过程中的毒理学研究-洞察阐释
- 中国舞蹈袜行业市场发展前景及发展趋势与投资战略研究报告(2024-2030)
- 2024年江苏宁海中学提前自主招生数学试卷真题(含答案详解)
- 儿童友好医院建设指南
- 蒙医学气功功法的介绍与实践
- 安全生产企业培训课件
- 【MOOC】西方园林历史与艺术-北京林业大学 中国大学慕课MOOC答案
- 第四届全国仪器仪表行业职业技能竞赛-无人机装调检修工(仪器仪表检测)理论考试题库(含答案)
- 2024版《53天天练单元归类复习》3年级语文下册(统编RJ)附参考答案
- 灭鼠行业营销策略方案
- 心脏瓣膜病患者的护理
- Unit2HealthylifestyleProjectDoahealthsurvey教学设计高中英语人教版选择性
- 经尿道前列腺电切术后膀胱冲洗的护理-课件
评论
0/150
提交评论