




免费预览已结束,剩余1页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
此文档收集于网络,如有侵权,请联系网站删除Subscribe to this information POWER5 information Locations model 55x and OpenPower 720Use this information to help you map a location code to a position on the server for the 9133-55A, 9406-550, 9113-550, and OpenPower 720 models.Note: The known logical location codes for this unit are listed next to the corresponding physical location in the following information. If you are working with a logical location code for this unit and it is not listed in the following information, contact your next level of support.The following diagrams show field replaceable unit (FRU) layout in the system. Use these diagrams with the following tables.If you need address information, refer to Addresses model 55x and OpenPower 720.Figure 1. Front view of the systemFigure 2. Back view of the system with 2 RIO/HSL ports on the planar and 1 bus card slot. Bus card is installed, port 1 is C6-T1 (closest to board) and port 0 is C6-T2 (towards the top of the card).Figure 3. Back view of the stand-alone system with 2 RIO/HSL ports on the planar and 1 bus card slot. Bus card is installed, port 1 is C6-T1 (closest to board) and port 0 is C6-T2 (towards the top of the card).Figure 4. Back view of the system with no RIO/HSL ports on the planar, but has 2 bus card slots (C6 and C14). When bus card is installed port 1 is Cx-T1 (closest to board) and port 0 is Cx-T2 (towards the top of the card).Figure 5. Back view of the stand-alone system with no RIO/HSL ports on the planar, but has 2 bus card slots (C6 and C14). When bus card is installed port 1 is Cx-T1 (closest to board) and port 0 is Cx-T2 (towards the top of the card).Figure 6. Top view of the system (including service processor reset switch)Figure 7. Memory module locations on the processor cardThe following table provides location codes for parts that make up the server.Attention: After replacing any part on a server or expansion unit, perform Verifying the repair.Table 1. FRU locations and failing componentsFailing item nameSymbolic failing item namePhysical location codeIdentify LEDLink to part numberFailing item removal and replacement proceduresSystem unitUnFansPCI adapters fan 1Un-A1YesPart assembly diagramsFansPCI adapters fan 2Un-A2YesPart assembly diagramsFansProcessor fan 1Un-A3YesPart assembly diagramsFansProcessor fan 2Un-A4YesPart assembly diagramsFansPower suppliesPower supply 1PWRSPLYUn-E1Yes51BAPower supplyPower supply 2PWRSPLYUn-E2Yes51BAPower supplyBackplanesSystem backplane SPCN Card enclosure or backplane Multi- adapter bridge (all) Service processor RIO Hub/HSL NIC RIO/HSL I/O Bridge RIO/HSL link Ethernet controller USB controller (AIX or Linux only) IDE bridge (AIX or Linux only) SCSI controller Logic oscillator InfiniBand host channel adapterHCAHSL_LNKMA_BRDGMABRCFGMASBUSNODEPLPIOCARDPPCITWRPRI_PCISI_PHBSVCPROCSIIOADPSYSBKPLSTORIOA TWRBKPLTWRCARDUn-P1Yes28ECSystem backplaneSCSI controller 0Un-P1-T14SCSI controller 1Un-P1-T15IDE controllerUn-P1-T16Time-of-day batteryUn-P1-E1Power partsService processor time-of-day batteryDisk drive (1 - 4) backplane Un-P2 (logical location Un-P1-T14-L15-L0)Yes28F628F7292C292EDisk drive backplaneDisk drive (5 - 8) backplane Un-P3 (logical location Un-P1-T15-L15-L0)Yes28F628F7292C292EDisk drive backplanePassthru cardConnects to internal SCSI bussesMedia drive backplaneUn-P4Yes28D1291EMedia device enclosureSystem backplane portssystem port 1Un-P1-T1S1 system port (front of control panel)Un-P1-T1system port 2Un-P1-T2SPCN 0 (upper connector)Un-P1-T3SPCN 1 (lower connector)Un-P1-T4HMC 1 (upper connector)Un-P1-T5HMC 2 (lower connector)Un-P1-T6USB port 0 (upper connector)Un-P1-T7USB port 1 (lower connector)Un-P1-T8Ethernet port A (0)Un-P1-T9Ethernet port B (1)Un-P1-T10RIO/HSL Port 0, leftUn-P1-T11, not available on 9133-55ARIO/HSL Port 1, rightUn-P1-T12, not available on 9133-55ARack indicator Un-P1-T13Processor and processor regulatorProcessor card 1Un-P1-C9Yes26F026F152378312Processor card 2Un-P1-C8Yes26F026F152378312Voltage regulator 1.5 V on Processor card 2Un-P1-C8-C9YesPower partsVoltage regulator modulesVoltage regulator 2.5 V/1.8 V on Processor card 2Un-P1-C8-C10YesPower partsVoltage regulator modulesVoltage regulator 1.5 V on Processor card 1Un-P1-C9-C9YesPower partsVoltage regulator modulesVoltage regulator 2.5 V/1.8 V on Processor card 1Un-P1-C9-C10YesPower partsVoltage regulator modulesVoltage regulator 1.2 V for Processor card 2Un-P1-C11YesPower partsVoltage regulator modulesVoltage regulator 1.2 V for Processor card 1Un-P1-C12YesPower partsVoltage regulator modulesVPD cardUn-P1-C13System partsVPD cardAdaptersPCI adapter in slot 1PIOCARDMASBUSSLOTERRUn-P1-C1YesSystem partsPCI adapterPCI adapter in slot 2PIOCARDMASBUSSLOTERRUn-P1-C2YesSystem partsPCI adapterPCI adapter in slot 3PIOCARDMASBUSSLOTERRUn-P1-C3YesSystem partsPCI adapterPCI adapter in slot 4PIOCARDMASBUSSLOTERRUn-P1-C4YesSystem partsPCI adapterPCI adapter in slot 5PIOCARDMASBUSSLOTERRUn-P1-C5YesSystem partsPCI adapterGX adapter cardSIIOADPSIADPCDUn-P1-C6Yes18061807RIO/HSL adapter cardGX adapter card port 1 (bottom)Un-P1-C6-T1YesRIO/HSL cables concurrentGX adapter card port 0 (top)Un-P1-C6-T2YesRIO/HSL cables concurrentGX adapter cardSIIOADPSIADPCDUn-P1-C14Yes18061807RIO/HSL adapter cardGX adapter card port 1 (bottom)Un-P1-C14-T1YesRIO/HSL cables concurrentGX adapter card port 0 (top)Un-P1-C14-T2YesRIO/HSL cables concurrentRAID enablement cardUn-P1-C7Yes5709RAID enablement cardPCI bridge set 1BRDGSETBRDGST1Un-P1Un-P1-C1Un-P1-C2Replace the system backplane and cards using the removal and replacement procedures corresponding to the locations indicated.PCI bridge set 2BRDGSETBRDGST2Un-P1Un-P1-C4Un-P1-C5Replace the system backplane and cards using the removal and replacement procedures corresponding to the locations indicated.PCI bridge set 3BRDGSETBRDGST3Un-P1Un-P1-C3Memory modulesMemory module 1MEMDIMMUn-P1-C8-C1YesMemory partsMemory modulesMemory module 2MEMDIMMUn-P1-C8-C2YesMemory partsMemory modulesMemory module 3MEMDIMMUn-P1-C8-C3YesMemory partsMemory modulesMemory module 4MEMDIMMUn-P1-C8-C4YesMemory partsMemory modulesMemory module 5MEMDIMMUn-P1-C8-C5YesMemory partsMemory modulesMemory module 6MEMDIMMUn-P1-C8-C6YesMemory partsMemory modulesMemory module 7MEMDIMMUn-P1-C8-C7YesMemory partsMemory modulesMemory module 8MEMDIMMUn-P1-C8-C8YesMemory partsMemory modulesMemory module 1MEMDIMMUn-P1-C9-C1YesMemory partsMemory modulesMemory module 2MEMDIMMUn-P1-C9-C2YesMemory partsMemory modulesMemory module 3MEMDIMMUn-P1-C9-C3YesMemory partsMemory modulesMemory module 4MEMDIMMUn-P1-C9-C4YesMemory partsMemory modulesMemory module 5MEMDIMMUn-P1-C9-C5YesMemory partsMemory modulesMemory module 6MEMDIMMUn-P1-C9-C6YesMemory partsMemory modulesMemory module 7MEMDIMMUn-P1-C9-C7YesMemory partsMemory modulesMemory module 8MEMDIMMUn-P1-C9-C8YesMemory partsMemory modulesDevice physical locationsDisk drive 1Un-P2-D1 (logical location Un-P1-T14-L8-L0 or Un-P1-Cn-Tn-L8-L01 )YesDisk unit partsDisk driveDisk drive 2Un-P2-D2 (logical location Un-P1-T14-L5-L0 or Un-P1-Cn-Tn-L5-L01)YesDisk unit partsDisk driveDisk drive 3Un-P2-D3 (logical location Un-P1-T14-L4-L0 or Un-P1-Cn-Tn-L4-L01)YesDisk unit partsDisk driveDisk drive 4Un-P2-D4 (logical location Un-P1-T14-L3-L0 or Un-P1-Cn-Tn-L3-L01)YesDisk unit partsDisk driveDisk drive 5Un-P3-D1 (logical location Un-P1-T15-L8-L0)YesDisk unit partsDisk driveDisk drive 6Un-P3-D2 (logical location Un-P1-T15-L5-L0)YesDisk unit partsDisk driveDisk drive 7Un-P3-D3 (logical location Un-P1-T15-L4-L0)YesDisk unit partsDisk driveDisk drive 8Un-P3-D4 (logical location Un-P1-T15-L3-L0)YesDisk unit partsDisk driveSCSI deviceUn-P4-D1 (logical location Un-P1-T14-L0-L0 with RPA partition and Un-P1-T14-L7-L0 with System i partition)Removable media device partsMedia deviceIDE device 1Un-P4-D2 (logical location Un-P1-T14-L1-L0 with RPA partition and Un-P1-T14-L6-L0 with System i partition)Removable media device partsMedia deviceIDE device 2Un-P4-D3Removable media device partsMedia device1 A logical location code with the form of Un-P1-Cn-Tn-Ln-Ln indicates that the disk is attached to a disk controller on a PCI adapter. Cn identifies the card slot of the PCI adapter. Tn identifies the port on the PCI adapter. Control panelControl panelUn-D128E5, 250CControl panel and signal cableTemperature sensorUn-D128E5seemControl panel and signal cableInput/output adapter (IOA) assignment rules for i5/OSThe following table provides information ne
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 第四单元 多姿多彩的乐音世界 第3课时《红梅赞》教学设计-2025-2026学年湘艺版(2024)初中音乐八年级上册
- 船舶水性水线漆项目可行性研究报告
- 涂膜市场竞争态势分析报告
- 防汛救灾知识培训课件
- 防汛抢险基本知识培训课件
- 语文9哲学家的思考
- 医疗服务合同
- 建设项目全过程造价咨询服务合同4篇
- 家具买卖合同样本2篇
- 河北省秦皇岛市实验中学2025-2026学年高二上学期开学考试物理试卷
- 2024年湖南省高中学业水平合格考物理试卷真题(含答案详解)
- 水机空调安装合同范本
- 本校学生对学校食堂满意度调查问卷
- 典范英语7the king of football概括
- DL-T-710-2018水轮机运行规程
- 我和我的祖国歌词
- 2023版《思想道德与法治》(绪论-第一章)绪论 担当复兴大任 成就时代新人;第一章 领悟人生真谛 把握人生方向 第3讲 创造有意义的人生
- (2024年)发生输液反应时应急预案及处理流程
- 水域救援知识课件
- 军兵种知识教案课件
- 国际贸易理论与实务(陈岩 第四版) 课件全套 第0-16章 绪论、国际贸易理论、国际贸易政策-国际贸易方式
评论
0/150
提交评论