International Journal of Fatigue 23 2001 55 64 Fatigue analysis and life prediction of bridges with structural health monitoring data Part II application T H T Chan Z X Li J M Ko Department of Civil and Structural Engineering The Hong Kong Polytechnic University Kowloon Hong Kong Received 20 September 1999 received in revised form 4 April 2000 accepted 9 June 2000 Abstract This paper is a continuation of the paper titled FATIGUE ANALYSIS AND LIFE PREDICTION OF BRIDGES WITH STRUC TURAL HEALTH MONITORING DATA PART I METHODOLOGY AND STRATEGY with the emphasis on application of the developed method to the fatigue damage assessment of the Tsing Ma Bridge Based on the methodology and strategy of the fatigue analysis presented in Part I fatigue damage analysis and service life prediction of the bridge deck section of the Tsing Ma Bridge TMB are carried out by using the strain time history data measured by the structural health monitoring system of the bridge The stress spectrum of the representative block of cycles at the location of strain gauges in a typical longitudinal truss is obtained by rainfl ow counting of cycles of stress history and statistical analysis on daily samples of daily stress spectrum The effect of low stress cycles on the fatigue and service life is considered by modifying the stress range when it is less than a limit value of stress range Results of fatigue damage and service life are calculated respectively by the model developed in Part I and Miner s rule are compared The infl uence of updating on the calculation of fatigue damage and predicted service life is numerically investigated The result shows that the magnitude of the stress range of the bridge deck section considered on TBM is in the region of greatest concern of bridge fatigue and values of fatigue damage and predicted service life as an estimation of the state of fatigue for the bridge are found to be reasonable 2001 Elsevier Science Ltd All rights reserved Keywords Structural health monitoring Fatigue damage Life prediction Bridge deck section Statistical analysis Rain fl ow counting Stress spectrum 1 Introduction A bridge health monitoring system called Wind and Structural Health Monitoring System WASHMS 1 2 has been devised to monitor the structural health and performance of the three cable supported bridges built for the development of the new airport in Hong Kong namely the Tsing Ma Bridge the Kap Shui Mun Bridge and the Ting Kau Bridge As an important part of struc tural health the durability of the bridge structure is mainly dominated by fatigue behavior of the critical elements of the bridges An accurate estimation of the actual situation in fatigue and remaining life of these bridges is an important task of the bridge health monitor ing system which is necessary for the bridge adminis Corresponding author Southeast University College of Civil Engineering 2 Si Pai Lou Nanjing 210018 People s Republic of China Tel 86 25 379 3384 fax 86 25 771 2719 E mail address zhxli Z X Li 0142 1123 01 see front matter 2001 Elsevier Science Ltd All rights reserved PII S0142 1123 00 00069 4 tration to make cost effective decisions regarding inspec tion maintenance and repair In recent years the fatigue response of steel bridge members under variable amplitude long life loading has been studied by Moses 3 Schilling 4 5 Fisher 6 9 and others 10 13 in which a lot of experimental investigation was done and particular emphasis was paid to the fatigue behavior of welded attachments Since steel bridges are manufactured with many components joined by welding special attention must be given to these connections because they are frequently the critical locations for fatigue damage and failure The knowledge in weld construction welded structures and relative experiments 14 19 is also very useful for fatigue dam age assessment of welded structures However still not enough information is available on mathematical analy ses of welded joints because such joints tend to be com plicated in form and non standard It is necessary to make use either of fi nite element methods or of experi mental techniques such as photo elasticity for associate stress analysis 56T H T Chan et al International Journal of Fatigue 23 2001 55 64 Miner s law is recommended for fatigue analysis in almost all codes for fatigue design and evaluation of steel bridges It gives a linear estimation of cumulative fatigue damage However fatigue damage at a variable amplitude stress spectrum has been shown to be a pro cess of nonlinear cumulative damage In order to obtain an accurate estimation of fatigue damage and remaining life it is necessary to apply a new approach for fatigue damage assessment to the Tsing Ma Bridge This paper is a continuation study of Part I of the paper with the same title 17 on how to apply the proposed method to the Tsing Ma Bridge Based on the methodology and strategy of the fatigue analysis presented in that paper fatigue damage assessment and life prediction of the bridge deck section of the Tsing Ma Bridge is carried out by using the strain time history data measured by the health monitoring system for the bridge It is a sig nifi cant work since it is the fi rst time the fatigue damage has been assessed and the service life of such a large suspended bridge with the most heavily instrumented online monitoring system in the world predicted It is also signifi cant to apply the fatigue damage model based on the continuum damage mechanics CDM to the fatigue damage analysis of a large suspended bridge It will be seen that some problems have to be dealt with in this application such as counting of variable amplitude stress cycles statistical analysis of the representative block of cycles the treatment of low stress cycles and so on After solving these problems some useful results Fig 1 Location of strain gauges in the cross frame of TMB 26 a the cross frame of TMB b details of the location of SSTLN 1 and SRTLN 01 on fatigue damage assessment and prediction of service life can be obtained 2 The structural health monitoring system and measured strain time history The Tsing Ma Bridge with a 2 2 km total span and a main span of 1377 m is the longest suspension bridge in the world carrying both highway and railway traffi c As the main part of the Lantau Link a combined high way and railway transport connection between Tsing Yi Island and Lantau Island it forms an essential part of the transport network for the new airport of Hong Kong The Bridge was commissioned on May 22 1997 In order to ensure user comfort and bridge safety a structural surveillance system or simply the bridge moni toring system has been devised by the Highways Depart ment of the Hong Kong SAR Government to monitor the integrity durability and reliability of the bridge This monitoring system for the Tsing Ma Bridge comprises a total of approximately 265 sensors including acceler ometers strain gauges displacement transducers level sensors anemometers temperature sensors and weigh in motion sensors permanently installed on the bridge and the data acquisition and processing system The strain gauges were installed to measure strains at bridge deck sections shown in Fig 2 of Part I of this paper The locations of strain gauges installed in the Tsing Ma 57T H T Chan et al International Journal of Fatigue 23 2001 55 64 Table 1 Details of the location of strain gauges in the cross frame Gauge No DetailGauge No DetailGauge No DetailGauge No DetailGauge No Detail SSTLN 01ASSTLS 01BSSTLS 10MSPTLN 05ASPTLS 09G 02E 02P 11HSPTLS 01B 10K 03A 03R 12H 02B 11L 04F 04J 13H 03B 12B 05F 05J 14H 04N 13M 06F 06JSPTLN 01A 05N 14H 07K 02A 06P 15H SRTLN 01C 08L 03A 07R 16H SRTLS 01D 09B 04E 08G 17H Bridge include the rail track sections bridge deck trough section and the deck at the tower and rocker bear ing links In this paper the strain time histories measured by strain gauges at the rail track section are used to show how the fatigue damage assessment is carried out for the welded connection near a gauge Fig 1 shows the locations of strain gauges including two sets of rosette strain gauges and 42 linear strain gauges in the section The location of each strain gauge in the section can be better found from Table 1 together with Fig 4 The strain gauge numbered by SSTLN nn and SSTLS nn represent the linear strain gauge set at the north and south of the cross frame respectively and SPTLN nn and SPTLS nn a pair of linear strain gauges set at the north and south of the cross frame respectively While SRTLN 01 and SRTLS 01 are two sets of rosette strain gauges in the north and south respectively Fig 1 b shows details of the location of a linear strain gauge numbered SSTLN 01 and a set of rosette strain gauges SRTLN 01A SRTLN 01B and SRTLN 01C The strain gauge SSTLN 01 is on the top chord of the outer longitudinal truss and the rosette strain gauge SRTLN 01 is located on the web of top chord outside the outer longitudinal truss Typical daily strain time his tories measured by strain gauges SSTLN 01 have been shown in Fig 5 of the companion paper 20 Further observation of the strain time history is shown in Fig 2 in which the strain time curves at May 15 1999 for a 5 minutes and b an hour are given respect ively The following observations can be obtained from examining these fi gures O Daily strain time curves are similar from day to day There are some common characteristics in curve shape and magnitude of cycles For example there are almost no strain pulses from 01 30 to 05 30 since the airport railway stops its service at this time period every day and also few vehicles are on the road of the bridge O The strain time curve in one hour can be considered to be composed of many small pulses of strain and Fig 2 Strain time histories at May 15 1999 for a fi ve minutes and b an hour some higher pulses at the rate of approximately one high pulse per two minutes O Each pulse in the strain time curve corresponds to a stress cycle generating accumulative fatigue damage Many small pulses in the strain time curve as shown in Fig 2 b should be neglected in the fatigue calcu lation since the magnitude of related stress cycles is less than the threshold value for fatigue damage Therefore the fi rst step in strain data reduction for fatigue analysis is to determine the sequence of peaks and valleys in strain time history in which a hysteresis threshold or dead band is employed to eliminate small peaks and valleys while retaining the overall sequence of strain Then the stress time history at location of the strain gauge is simply obtained by Young s law since the strain is elastic 58T H T Chan et al International Journal of Fatigue 23 2001 55 64 3 The stress spectrum of the representative block 3 1 Rainfl ow counted cycles The daily cyclic stress time history is composed of complicated variable amplitude cycles with signifi cant variation in the value of the mean stress It is necessary to apply a proper counting scheme developed by Dow ling 21 in which the mean stress of each cycle can be determined for the fatigue failure prediction of compli cated stress history with fl uctuating mean stress In this work the rain fl ow counting procedure developed by Downing 22 is used to count closed stress strain hys teresis loops as cycles at different levels of stress range and mean stress in a daily block of cycles The results of rain fl ow counting for a daily block of cycles are given in Fig 3 which shows stress cycles in the block of cycles on May 17 1999 at the location of the strain gauge SS TLN 01 The stress cycles are distributed in the stress range from 2 MPa to 16 MPa and the mean stress varies from 28 MPa to 24 MPa 3 2 Statistical analysis According to the fatigue analysis approach proposed in Part I a standard block defi ned as the representative block of cycles should be obtained by statistically ana lyzing many samples of daily block at the same location of the strain gauge To show the accuracy of the statisti cal analysis a parameter called Mean Absolute Percent age Error MAPE is calculated MAPE as an average accuracy to measure how the results of the statistical analysis close to the daily samples to be analyzed is defi ned as follows Fig 3 Rainfl ow counted cycles distribution with respect to stress range and mean stress MAPE r m 5O n i51 Ci r m C0 r m n 1 where n is the number of samples of daily stress spec trum to be analyzed Ci r m denote the value of cycle counts at r m a given region of stress range and mean stress for the ith sample to be analyzed C0 r m denotes the value of cycle counts at r m for the result of the statistical analysis which is the value of cycle counts for the standard or representative block 3 3 Hot spot stress at the toe of considered weld With the nominal stress at the location of the strain gauge the hot spot stress at toe of the weld near the strain gauge can be obtained provided the following information is given 1 the local stress distribution in the effected region sur rounding the strain gauge and its nearest welded con nection 2 Stress Concentration Factor SCF in the vicinity of the weld due to geometric discontinuities 3 Residual stress and defect at toe of the weld due to welding Suppose the above information affecting the hot spot stress at the toe of the weld can be expressed by related factors the hot spot stress at the toe of the weld near the strain gauge can be given by following equation sH5KwKdKgS 2 where S is the nominal stress at the location of the strain 59T H T Chan et al International Journal of Fatigue 23 2001 55 64 gauge Kgis a SCF in the vicinity of the weld due to geometric discontinuities Kdis the factor for the distri bution of stress at the toe of the weld and Kwis the factor that expresses the infl uence of residual stress and defect at the toe of the weld due to welding The factor Kdcan be obtained by local stress analysis by the fi nite element and the structural model proposed in 20 and the SCF of Kgmay be obtained from the handbook on stress concentration factors 23 or by fi nite element calculation However it is diffi cult to get the factor Kwfrom any handbook As mentioned in the Intro duction welded structural members have complex geometry and metallurgy in the vicinity of the weld and they may contain defects generated due to welding As a result design codes that cover welded structural mem bers usually employ component S N curves based on extensive testing of actual welded members Besides there are some works to provide the SCF for some kind of welds obtained in photoelastic studies 14 In this work the SCF factor Kwwill be estimated for the con sidered weld according to the results of tests on weld and referenced values of SCF in the references 14 16 As an example of determining the hot spot stress the welded connection nearest to the linear strain gauge SSTLN 01 shown in Fig 4 as detail I of Fig 1 is analyzed here The weld A A is a double bevel butt with superimposed fi llet weld SCF due to geometric disconti nuity Kg 1 is obtained since there is no evident change in shape or geometric discontinuities in the vicinity of the weld Kdis estimated as an approximate value of 1 14 according to the result of local stress analysis The factor Kwis estimated as an approximate value of 2 06 according to referenced test results 14 16 4 Treatment of low stress cycles It can be seen from the stress spectrum of the rep resentative block of cycles that the TMB is subjected to a very large number of relatively small stress cycles This is a common situation for existing bridges How Fig 4 Detail I the connection near to SSTLN 01 27 ever stress cycles at the stress range below the stress limit to fatigue have no contribution to accumulative fatigue damage in the model developed in Part I The model should be improved for considering the effect of low stress cycles on the fatigue damage of existing bridges When Miner s rule is used to evaluate the fatigue damage the treatment of low stress cycles is simply done as that in the design code 25 The number of repetitions of each stress range less than a limit of stress range should be reduced in a proportion that is the accumulative fatigue damage due to the ith stress range is reduced as ni Nfi5 niDsm 2 i K2Ds2 0 When Dsi Ds0 3 where K2and m have values given in the code 25 for different detail classes niis the number of repetitions of the ith stress range Dsi N fi is the number of cycles to failure at the ith stress range and Ds0is the limit value of stress range given by the following equation for N fi 107 Nfi5K2Ds m i 4 The above equation implies that the contribution of low stress cycles to fatigue damage is reduced in the proportionSDsi Ds0D 2 m This modifi cation corresponds to the extension of the S N curves to the low stress range instead of the constant amplitude fatigue limit Using the same treatment of low stress cycles in the CDM fatigue damage model the fatigue equation developed in Part I should be modifi ed by replacing the stress range with the equivalent stress range Ds e i when the stress range is less than Ds0 Therefore CDM fatigue damage model given in Equation 14 of the companion paper Part I 20 is now rewritten as D 1 H1 a 1 Nbl B b 3 O mrb i51 Ds e i 2smi Ds e i b 3 2J 1 a 1 Ds e i Dsiwhen Dsi Ds0 Ds e i DsiSDsi Ds0D 2 m when Dsi Ds0 6 where Dsiis a variable amplitude stress range It should be noticed that Equation 14 in Part I is expressed by the stress amplitude sai and the relation between these two variables is as follows sai 1 2Dsi Here the stress ranges are employed in Eq 6 in order to follow the usual engineering expression Other symbols in Eq 6 are all defi ned in Part I 20 60T H T Chan et al International Journal of Fatigue 23 2001 55 64 5 Analysis of calculated results Based on the above analysis about the stress spectrum for the representative block of cycles and the detail of connection near the strain gauge fatigue analysis for the bridge deck section of Tsing

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论